DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Similar documents
Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

(1,5 modules per pole)

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

RX 3 ->CATALOG PAGES INSIDE. the global specialist

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

OptiLine 45 Floor boxes

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Single phase meter with direct connection and pulse or Modbus RS485 output

Raised Floor system LIMOGES Cedex. Phone : Fax :

RX 3 ->CATALOG PAGES INSIDE. the global specialist

Door Hinges Drill-in Hinges

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Empty enclosures AKL / AKi ITC - AKL / AKi Enclosures

Flush Floor system LIMOGES Cedex. Phone : Fax :

DLP-S Trunking LIMOGES Cedex. Phone : Fax :

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

3-phase meter with direct connection and pulse or Modbus RS485 output

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

Wiring ducts Easily allows for organization, pulling and separation of cables

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

Customer Premise. Solutions for. Solutions for Customer Premise include products ranging from wall distribution to system distribution boxes.

DISCONNECT SWITCHES. UL Listed CSA Certified

Technical features table for miniature circuit-breakers SH 200 Series

Current / residual current and voltage transformers. Current / residual current and voltage transformers

ALPHA DIN Wall-Mounted. Distribution Boards

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

SRS IT cabinets. Installation height numbering as a standard

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

Atlantic. ip40-ip65 Metal distribution switchboard. Certifications. Technical features. Electrical properties

Cable Management Solutions with DLP TM

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

19-in. Mini-Rack Cabinet, Type 1

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

Accessories for cable trunking

Safety switches with slotted hole lever

DATA SHEET Selectable AC transducer TAS-311DG

Junction boxes. Surface mounting - IP44 - IP55 - IP56 TECHNICAL CHARACTERISTICS

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

DLPlus. Dado and Skirting trunking LIMOGES Cedex. Phone : Fax :

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Operator Heads: ø 22mm

Complete units: Push-buttons ø 22mm

Executive furniture. Moka

Local control stations for Zone 1 and Zone 21. Features. Description

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

Distribution Blocks, Power Blocks, Power Terminals

Control Stations ø 22

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Complete units: Selector switches ø 22mm

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

Measuring current transformers of the W, W series

HOSTESS TROLLEY U.K.

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

Components for low voltage panel boards

General catalogue Export SMOUTS ARCHITECTEN

Complete units: Mushroom heads ø 22mm

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Accessories. Accessories

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Inner Width (w1) mm

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

DISTRIBUTION BLOCKS POWER BLOCKS POWER TERMINALS

Ultra-efficient installation solutions

48 Series - Relay interface modules A. Features

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Standardised distribution boxes Product overview: Polyester enclosure

Bar supports. Bar supports

INSTALLATION INSTRUCTIONS

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

1.4 Section LAMPHOLDERS AND INLINE SWITCHES. Design. Scame by VLM

EAO Product Information. Series 84

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

DATA SHEET. Switchboard instruments,

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

ASSEMBLY INSTRUCTIONS FOR SL500A AND SL500AL

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

WALL SHELVING SYSTEM 250/750

Operator Heads: ø 22mm

Differential pressure sensors

Snap-on Aluminium trunking. Number(s) : /13/17/19/22/24/28/30/34/36/40/42,

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

Motor starters. TeSys E. Designed for the essential

Relay interface modules A

Actuators Series 8602/3

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

NEW CIRCUIT PROTECTIONRANGE

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

Transcription:

87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2 5. Compliance and Approvals....2 6. Equipment supplied....3 7. Installation accessories.....3-4-5-6 1. DESCRIPTION, USE Cabinets with rows of 13 or 18 modules compliant with regulations governing public buildings and high-rise buildings in accordance with standard EN 60695-2-11. Conform to IEC 60670-24 and IEC 62 208. For the production of assemblies certified according to IEC 61 439-3. Can be mounted on housing service ducts or wall-mounted. Adjustable and removable rails. Space under rails: 40 mm Distance between rails: 125 mm 2. RANGE, CAT. NO. EQUIVALENCE TABLE DRIVIA Number of rows Number of modules Ekinoxe 4 013 63 3 39 0 013 63 4 013 64 4 52 0 013 64 0 930 20 1 13 0 927 17 0 930 21 2 26 0 927 18 0 930 22 3 39 0 927 19 0 930 23 4 52 0 927 30 3. DIMENSIONS 13/18-module cabinets DRIVIA Number of Number of Ekinoxe rows modules 4 012 11 1 13 0 012 11 4 012 12 2 26 0 012 12 4 012 13 3 39 0 012 13 4 012 14 4 52 0 012 14 4 012 16 1 13 0 012 16 4 012 17 2 26 0 012 17 4 012 18 3 39 0 012 18 4 012 19 4 52 0 012 19 4 012 21 1 18-4 012 22 2 36-4 012 23 3 54-4 012 24 4 72-4 013 11 1 13 0 013 11 4 013 12 2 26 0 013 12 4 013 13 3 39 0 013 13 4 013 14 4 52 0 013 14 4 013 21 1 13 0 013 21 4 013 22 2 26 0 013 22 4 013 23 3 39 0 013 23 4 013 24 4 52 0 013 24 4 013 61 1 13 0 013 61 4 013 62 2 26 0 013 62 13 M 18 M Dimensions (mm) A B C D 4 012 11/16-0 930 20 4 013 11/21/61 4 012 12/17-0 930 21 4 013 12/22/62 4 012 13/18-0 930 22 4 013 13/23/63 4 012 14/19-0 930 23 4 013 14/24/64 250 113 250 217 250 238 375 217 250 363 500 217 250 488 625 217 4 012 21 355 113 250 322 4 012 22 355 238 375 322 4 012 23 355 363 500 322 4 012 24 355 488 625 322 Technical data sheet: F01504EN/04 Updated: 18/11/2015 Created: 14/05/2012 1 / 6

+ DRIVIA cabinets 4. GENERAL CHARACTERISTICS 4.1 Technical characteristics. Cover colour: White RAL 9003. Door colour: White RAL 9003 or transparent. Protection index: IP30 IK05 without door IP40 IK07 with door. Self-extinguishing: 750 C (public buildings). Insulated backplate for Cat. Nos. 4 012 16/17/18/19 4 013 21/22/23/24. Double insulation possible with insulated backplate (other Cat. Nos.). Rated operating voltage: 400V AC 50/60 Hz. Rated insulation voltage: 400V AC 50/60 Hz. Rated impulse withstand voltage: Uimp = 6kV. Short-circuit current: 10 ka. Storage and installation temperature: -20 C to + 70 C. Operating temperature: -10 C to + 40 C. Max. permissible current: 4 012 11/16-0 930 20 : 60A 4 013 11/21/61 : 60A 4 012 12/13/14/17/18/19/21/22/23/24 : 90A 0 930 21/22/23 : 90A 4 013 12/13/14/22/23/24/62/63/64 : 90A. Permissible loads : 40N per row. Power dissipation:. Cover plastic screws service torque : 2Nm 4.2 Materials 13 modules 18 modules 1 row 27 W 28 W 2 rows 35 W 45 W 3 rows 52 W 67 W 4 rows 57 W 91 W. Cover, frame: high impact polystyrene. Door: polycarbonate. Handle: ABS + chrome. Labelling strip: polycarbonate. Rail supports: glass fibre filled polycarbonate. Cover screws: glass fibre filled polycarbonate. Rails: galvanised steel. Door release: polyamide. Hinge: polypropylene. Joining kit: glass fibre filled polycarbonate. Document holder: high impact polystyrene 4.3 Terminal block capacity Earth terminal block Cage terminals Automatic terminals 1.5-4 Ph + N terminal block Screw terminals 10-35 4 012 11 0 930 20 5 9 - - 4 012 12 0 930 21 5 18 1 5 4 012 13 0 930 22 5 27 1 5 4 012 14 0 930 23 5 27 1 5 4 012 21 5 27 - - 4 012 22 5 27 1 5 4 012 23 5 36 1 5 4 012 24 5 45 1 5 4 012 16 5 9 - - 4 012 17 5 18 - - 4 012 18 5 27 - - 4 012 19 5 27 - - Earth terminal block Screw terminals 1.5-16 Neutral terminal block Screw terminals 1.5-16 4 013 11 1 12 - - 4 013 12 1 21 - - 4 013 13/14 1 26 - - 4 013 21 1 12 1 12 4 013 22 1 16 1 16 4 013 23 1 21 1 21 4 013 24 1 26 1 26 4 013 61 1 12 1 12 4 013 62 1 21 1 21 4 013 63/64 1 26 1 26 Additional terminal blocks (see section 7.3, page 4) 4.4 Number of blanking plates 5 modules 13 modules 4 012 11/16/21 0 930 20 1-4 012 12/17/22 0 930 21 2-4 012 13/18/23 0 930 22 1 1 4 012 14/19/24 0 930 23 2 1 4 013 11/21/61 1-4 013 12/22/62 2-4 013 13/23/63 2 1 4 013 14/24/64 2 1 2 / 6

5. COMPLIANCE AND APPROVALS IEC 60670-24 IEC 62 208 NF C61-910 IEC 60695-2-11 RoHS WEEE REACH PEP sheet NF 6.3 Adhesive document holder Cat. Nos. - 0 930 20/21/22/23 6. EQUIPMENT SUPPLIED Cat. Nos. - 0 930 20/21/22/23 6.1 Joining 1 joining kit supplied per cabinet - Vertical and horizontal joining 6.2 Fixing - Fixing on any type of wall (adjustment of drilling error) 7. INSTALLATION ACCESSORIES 7.1 White or transparent doors White doors Transparent doors 1R 13M 4 013 31 4 013 41 2R 13M 4 013 32 4 013 42 3R 13M 4 013 33 4 013 43 4R 13M 4 013 34 4 013 44 1R 18M 4 012 31 4 012 41 2R 18M 4 012 32 4 012 42 3R 18M 4 012 33 4 012 43 4R 18M 4 012 34 4 012 44 1R 13M DIY* 0 93 030-2R 13M DIY 0 93 031-3R 13M DIY* 0 93 032-4R 13M DIY* 0 93 033 - * DIY: Do-It-Yourself Distribution Door thickness: 37 mm - Fixing on service duct with spacer 3 / 6

7. INSTALLATION ACCESSORIES (continued) 7.4 Spacers (depth 50 mm) 7.2 Key lock 4 013 91 Spacer for 13-module cabinets 4 013 71 4 013 72 4 013 73 4 013 74 a 236 236 236 236 b 126 126 126 126 c 201 326 451 576 7.3 Additional terminal blocks IP 2X automatic connection earth terminal block for 13-module cabinet: 4 050 55 (capacity: 5x6 for 25 mm² + 27x1.5 for 4 mm²) IP 2X automatic connection earth terminal block for 18-module cabinet: 4 050 57 (capacity: 5x6 for 25 mm² + 45x1.5 for 4 mm²) IP 2X screw earth terminal block for 13-module cabinet: 4 048 39 (capacity: 1x6 for 25 mm² + 26x1.5 for 16 mm²) IP 2X 3-pole + neutral insulated terminal block for 13-module cabinet: 4 048 14 (1 neutral 1x4 for 25 mm² + 12x1.5 for 16 mm²) + (3 phases 4x1.5 for 16 mm²) Support for additional terminal block for 13-module cabinet: 4 048 18 28-hole empty support for unprotected screw terminal blocks and for IP2 terminal blocks. d 204 329 454 579 Spacer for 18-module cabinets 4 012 71 4 012 72 4 012 73 4 012 74 a 341 341 341 341 b 231 231 231 231 c 201 326 451 576 d 204 329 454 579 Spacer for 13-module cabinets + mounting plate Réf. 4 013 81 4 013 82 4 013 83 4 013 84 a 233 233 233 233 b 126 126 126 126 c 426 551 676 801 d 429 554 679 804 4 / 6

7. INSTALLATION ACCESSORIES (continued) 7.5 Backplates supplied with caps to ensure double insulation 7.8 Finishing kit for cabinets mounted on housing service duct 4 013 94 For 13 and 18-module cabinets and service ducts 13M 18M Cabinet 4 012 11/16 4 013 11/61-0 930 20 4 012 12/17 4 013 12/62-0 930 21 4 012 13/18 4 013 13/63-0 930 22 4 012 14/19 4 013 14/64-0 930 23 Backplate 4 013 51 4 013 52 4 013 53 4 013 54 4 012 21 4 012 51 4 012 22 4 012 52 4 012 23 4 012 53 4 012 24 4 012 54 7.9 Locking clip Locking clip for fixing cable ties to a rail: Cat. No 0 319 78 7.6 Mounting plates for subscriber headline MCCB Conforming to NF C 61-910 Functional earth connection 7.10 Covers for consumer unit (depth 126 mm) For circuit-breaker only: Cat. No 4 011 91 For circuit-breaker and 3-phase electronic meter: 4 011 83 Compliant with HN 62-S-80 specifications For circuit-breaker and single-phase electronic meter: 4 011 81 Compliant with ERDF-CPT-M&S Spe-10015A specifications 7.7 White RAL 9003 blanking plates Can be separated for each module or half-module 5 modules: 0 016 60 13 modules: 0 016 62 18 modules: 0 016 64 A B 4 013 85 526 502 4 013 86 651 627 4 013 87 776 752 5 / 6

7. INSTALLATION ACCESSORIES (continued) - Rail supports kit 9 803 77 7.11 Adhesive document holder 4 013 89 7.12 Spare parts - Hinge and door release kit 9 803 74 - Pack of 20 cover screws 9 803 75 - Fixing kit 9 803 76 6 / 6