EC Declaration of Conformity

Similar documents
EC Declaration of Conformity

50000 Counts Dual Display Digital Multimeter

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR

CIRCUIT-TEST ELECTRONICS

Dual Display Digital Multimeter

Synthesized Function Generator

Arbitrary Function Generator

FUNCTION GENERATOR OPERATION MANUAL

8120 FUNCTION GENERATOR Operation Manual

8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Arbitrary Function Generator

Arbitrary Function Generator

30MHz Dual Trace Oscilloscope

BENNING. CM7 Electrical Tester. Service Information

Model 4007DDS. 7 MHz Sweep Function Generator

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Sweep Function Generator with External Frequency Counter Instruction Manual

AC/DC CLAMP METER USER S MANUAL

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

DDS Function Generator

TT-SI MHz Active Differential Probe

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

TT-SI MHz Active Differential Probe

Arbitrary/Function Waveform Generators 4075B Series

MULT SWP X1K K VERN START FREQ DURATION AMPLITUDE 0 TTL OUT RAMP

The specifications apply when the function generator is powered on for at least 30 minutes under 18 C~28 C.

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Model and

DM-45 Digital Multimeter

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

SAFETY PRECAUTIONS: Before use, read the following safety precautions

FG-7002C. Sweep Function Generator Operation Manual

MODEL 3810/2 Line Impedance Stabilization Network

TT-SI 9001 / TT-SI MHz Active Differential Probes

Electrical Safety Tester

INSTRUCTION MANUAL MODEL 4010A. 2 MHz FUNCTION GENERATOR MANUAL DE INSTRUCCIONES MODELO 4010A. 2MHz GENERADOR DE FUNCIONES

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

ET-3888 True RMS Clamp Meter. User Manual

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Appendix A: Specifications

79/26 Series III Multimeter

HAWK5000 Operators Manual

EPA152/252/502. User Manual.

User s Manual Current Probe. IM E 2nd Edition IM E

TT-SI MHz DIFFERENTIAL PROBE

Pen-type DIGITAL MULTITESTER

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

TMP40. User Manual.

(ES) Equipements Scientifiques SA - Département Tests & Mesures rue de Buzenval BP Garches Tél Fax.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

This DDS function generator is designed for use in such applications as communication equipment and electronic components production.

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

8PK-ST1520 Digital Earth Resistance Tester

Publication Number ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR. User s Guide

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

TG550 AIM & THURLBY THANDAR INSTRUMENTS. 5MHz function generator with sweep

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Model : OPERATING MANUAL Table of Contents (1)

Multi-output DC Power Supply

Digital Function Generator

FUNCTION GENERATOR FG 8210

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Digital Clamp Meter Model: &

EPA104/254. User Manual.

INSTRUCTION MANUAL. Model 4012A. 5 MHz SWEEP FUNCTION GENERATOR. with DIGITAL DISPLAY

USER'S MANUAL DMR-6700

Model MHz Arbitrary Waveform Generator Specifications

3B SCIENTIFIC PHYSICS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

AFG-2100/2000 Series Arbitrary Function Generator. New Product Announcement

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

EARTH RESISTANCE TESTER

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

400 MHz Passive High-Voltage Probe R&S RT-ZH

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

AMM-1022 Digital Multimeter USER`S MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

MD 200A High voltage differential probe

Power supply CP-E 24/2.5

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Power supply CP-E 24/20.0

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Transcription:

EC Declaration of Conformity TABLE OF CONTENTS 1. SAFETY SUMMARY.. 1 2. INTRODUCTION 5 3. SPECIFICATION 7 EN 61326-1: Electrical equipment for measurement, control and laboratory use EMC requirements (1997+A1: 1998) Conducted and Radiated Emissions Electrostatic Discharge EN 55011 Group I class A: 1991 EN 61000-4-2: 1994 Current Harmonic Radiated Immunity EN 61000-3-2: 1995 ENV 50140: 1993 Voltage Fluctuation Electrical Fast Transients EN 61000-3-3: 1995 EN 61000-4-4: 1995 Surge Immunity EN 61000-4-5: 1995 Conducted Susceptibility EN 61000-4-6: 1996 Power Frequency Magnetic field EN 61000-4-8: 1993 Voltage Dips/ Interrupts EN 61000-4-11: 1994 4. FUNCTION DESCRIPTION.. 11 5. USAGE DESCRIPTION. 14 6. MAINTENANCE. 19 Low Voltage Equipment Directive 73/23/EEC & amended by 93/68/EEC Safety Requirements EN 61010-1: 1990+A1: 1992+A2: 1995; IEC 61010-1: 1990+A1: 1992+A2: 1995 i www.tenma.com ii

1. SAFETY TERMS AND SYMBOLS DANGER High Voltage Please take a moment to review these safety terms and symbols, which may appear in this manual or on Equipment to prevent damage to the Function Generator. ATTENTION refer to Manual WARNING. Warning statements identify condition or practices that could result in injury or loss of life. Protective Conductor Terminal CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property. (Ground) Earth Terminal Frame or Chassis Terminal www.tenma.com 1 www.tenma.com 2

FOR UNITED KINGDOM ONLY NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code: Green/ Yellow: Earth Blue: Neutral Brown: Live (Phase) As the colours of the wires in main leads may not correspond with the colours marking identified in your plug/appliance, proceed as follows: The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with the letter E or by the earth symbol or coloured Green or Green & Yellow. The wire which is coloured Blue must be connected to the www.tenma.com 3

terminal, which is, marked with the letter N or coloured Blue or Black. The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red. If in doubt, consult the instructions provided with the equipment or contact the supplier. This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to the rating information on the equipment and/or user instructions for details. As a guide, cable of 0.75mm² should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A types, depending on the connection method used. Any moulded mains connector that requires removal /replacement must be destroyed by removal of any fuse & fuse carrier and disposed of immediately, as a plug with bared wires is hazardous if a engaged in live socket. Any re-wiring must be carried out in accordance with the information detailed on this label. 2. INTRODUCTION The 72-7710 Function Generator is a stable low distortion instrument, which generate signals in the frequency range up to 3MHz. Typical applications include a wide range of audio response testing applications, vibration testing, servo system evaluation, ultra sound applications, and etc. MAIN FEATURES 1. Low distortion waveforms (sine, triangular and square) and ramp signal. 2. Signal output in seven-decade stages, 0.3Hz to 3MHz 3. Duty cycle control with signal inversion capability. 4. External Voltage controlled Frequency (VCF). 5. Built in Frequency counter. 6. A second output for TTL or adjustable CMOS pulses. 7. 50 ohm main signal output with DC offset adjustment and 20dB attenuation capability. 8. Supplied with two BNC test leads and AC power cord set. www.tenma.com 4 www.tenma.com 5

FEATURES: FEATURE COUNTER TTL/CMOS VCF Duty Cycle Control MODEL 72-7710 ˇ ˇ ˇ ˇ 3. SPECIFICATION 1.Main Frequency Range Amplitude Impedance Attenuator DC Offset Duty Control Display 2.Sine Wave Distortion Flatness 3.Triangle Wave 0.3Hz~3MHz(7 Range) 10Vpp(into 50Ωload) 50Ω±10% -20dB±1dB 2 <-5V~>5V (into 50Ωload) 80%:20%:80% to 1MHz Continued variable 6 digits LED display 1%,0.3Hz~200kHz <0.3dB,0.3Hz~300kHz, <0.5dB,300kHz~3MHz Linear 98%,0.3Hz~100kHz, 95%,100kHz~3MHz 4.Square Wave Symmetry Rise or Fall Time 5.CMOS Output Level Rise or Fall Time 6.TTL Output Level Fan Out Rise or Fall Time 7.VCF Input voltage Input Impedance ±2%,0.3Hz~100kHz 100ns at maximum output (into 50Ωload) 4Vpp±1Vpp~14.5Vpp ±0.5Vpp adjustable 120ns 3Vpp 20 TTL load 25ns 0V~10V±1V(100:1) 10kΩ±10% 8.Frequency Counter Int./Ext. Switch selector Range 0.3Hz~3MHz, (5Hz~150MHz EXT) www.tenma.com 6 www.tenma.com 7

Accuracy Time base Resolution Input Impedance time base accuracy±1count ±20ppm(23 ±5 ) after 30 minutes warm up The maximum resolution is 10nHz for 1Hz and 0.1Hz for 100MHz. 1MΩ/150pF Sensitivity 35mVrms(5Hz~100MHz), 45mVrms(100MHz~150MHz) 9.General Power Source AC115V, 230V±15%.50/60Hz Indoor use, altitude up to 2000m. Ambient Temperature 0 to 40. Operation Environment Relative Humidity 80%(Maximum). Installation category II Pollution Degree 2 Storage temperature -10 to 70. & Humidity 70% (Maximum). Accessories GTL-101 2, Instruction manual 1 Dimension 251(W) 91(H) 291(D) m/m Weigh Approx. 2.1kgs Fig 4.1 FRONT PANEL WARNING : To avoid electrical shock, the power cord protective grounding conductor must be connected to ground. CAUTION:To avoid damaging the instrument, do not use it In a place where ambient temperature exceeds 40. CAUTION:To avoid damaging the instrument, do not input more than DC15V to V.C.F.(V.C.G.). CAUTION:To avoid damaging the instrument, do not input more than AC150V to Frequency Counter www.tenma.com 8 www.tenma.com 9

Fig.4-2 REAR PANEL 4. FUNCTION DESCRIPTION 1. Power Switch Connect the AC power, then press power switch. 2. Gate Time Indicator 2a. Gate Time Selector Press the power switch; Gate time indicator will start to flash (the gate time of the internal counter is 0.01 second). Press this key to change the gate time when used in the external counter mode. The change order is according to 0.01s, 0.1s, 1s, 10s cycle by pressing these keys. 3. Over Indicator In the external counter mode, the indicator is illuminated when the output frequency is greater than the range selected. 4. Counter Display Shows the external frequency by 6 0.3" green display, and shows the internal frequency by 5 0.3" green display. 5. Frequency Indicator 6. Gate Time Indicator 7. Frequency Range Selector Indicate the current frequency value. Indicate the current gate time (external. counter mode use only). To select the required frequency range by pressing the relevant push button on the panel as shown in Table 1 www.tenma.com 10 www.tenma.com 11

Table 1 Push bottom 1 10 100 1k 10k 100k 1M 0.3Hz 3Hz 30Hz 300Hz 3kHz 30kHz 300kHz Frequency Range 3Hz 30Hz 300Hz 3kHz 30kHz 300kHz 3MHz 8. Function Selector Press one of the three push buttons to select the desired output waveform. 9. Duty Function Pull out and rotate the knob to adjust the duty cycle of the waveform. 10. TTL/CMOS Selector When the knob is pushed in, the BNC terminal of 16 will output a TTL compatible waveform. If pulled out and rotated the knob can adjust the CMOS compatible output (5-15Vpp) from the output BNC 16. 11. DC Offset Control Pull out the knob to select a variable DC level between ±10V, turn clockwise to set a positive DC level waveform and anticlockwise for a negative DC level waveform. 12. Output Amplitude Control with Attenuation Operation Turn clockwise for MAX. output and invert for a 20dB output. Pull the knob out for additional 20dB output attenuation. 12a. 20dB Attenuation Press the knob to adjust a 20dB output. 13 Frequency Adjustment 14. INT/EXT Counter Selector 15. EXT. Counter Input Terminal 16. TTL/CMOS Output Terminal 17. VCF/MOD Input Terminal 18. Main Output Terminal Press and turn clockwise the knob for MAX frequency and invert for MIN frequency. (Keep the pointer within the scale range on the panel.). Select internal counter mode (count the frequency of model) or select EXT counter mode for an independent counter (input signal from BNC 15 ). Accepts external signals for measurement. TTL/CMOS compatible signal output Used to connect the input voltage required to perform the voltage control frequency operation or the EXT modulation operation. Main signal output. 19. Power Switch 115V and 230V selectable. www.tenma.com 12 www.tenma.com 13

5. USAGE DESCRIPTION The 72-7710 function generator can provide versatile waveforms of high efficiency. Familiarizing yourself with all of the functions of the 72-7710 thoroughly through both this operation manual and in practice will enable you to master the performance of this Tenma Function generator. One of the best ways to observe waveforms is by connecting the instruments to an oscilloscope and watching the effect of different controls and waveforms through the oscilloscope. 5-1.First-step check: (1) Ensure that the voltage of the main supply is compatible with this instrument. The label on the rear panel will indicate the required AC voltage. (2) Connect the instrument to the main supply using the power cord supplied. (3) Press PWR switch 1 and ensure all the rotary controls are pushed in, then rotate AMPL 12 knob to make the indication point up forward. (4) Rotate the FREQ 13 control fully anticlockwise. 5-2.Triangle, square and sine wave (1) First select Function 8, and select Range 7, rotate FREQ 13, to set the required frequency. (read out from display window). (2) Then, connect the Output 18, to an oscilloscope to observe the output signal, or connect to the circuit under test. (3) Rotate the AMPL 12 again to control waveform amplitude. (4) If an attenuation output signal is required, pull out AMPL 12 knob to obtain 20dB attenuation or press (12a) knob for additional 20dB attenuation.. (5) The phase-relationship of the output waveform is shown in Figure 1 as below: Figure 1. www.tenma.com 14 www.tenma.com 15

5-3.Pulse wave generation (1) First press the key ( ) Function 8 ; then select Range 7, and rotate FREQ 13, to set the required frequency range. (2) Connect the output-terminal 18 to an oscilloscope to observe the output signal. (3) Pull out and rotate the Duty knob 9 to adjust the width of pulse waveform. (5) Adjust the AMPL 12 knob to control the pulse amplitude. (6) Pull out the AMPL 12 knob to get 20dB attenuation of output. 5-4.Ramp wave generation (1) First press the key ( ) Function 8, then select Range 7, and rotate the FEEQ 13 knob to set required frequency range. (2) Connect the output-terminal 18 to an oscilloscope to observe the output signal. (3) Pull out and rotate the DUTY9 to adjust the slope of the ramp waveform. (4) Adjust AMPL 12 knob to control the output amplitude of the ramp waveform. (5) Pull out AMPL 12 knob to obtain 20dB attenuation of output. 5-5.TTL/CMOS signal output (1) First select Range 7, rotate the FREQ 13 knob to set required frequency range. (2) Connect the BNC connector of TTL/CMOS 16 to an oscilloscope or to the circuit under test. (3) The output is a square waveform set to TTL level; (for general TTL integrated circuit.) (4) If the square waveform set to a CMOS level is required, you can pull out CMOS 10 knob to adjust voltage level. 5-6.Variation of external voltage-controlled frequency This mode of operation allows the user to adjust the frequency of the function generator with an external DC control Voltage. It also provides an easy way to make adjustments. (1) Select Function 8 first, then select the Range 7, and rotate FREQ 13 to set the required frequency range. (2) Connect an external control voltage (0 ~ 10V) to the VCF 17 connector via a suitable lead, the generated signal is on Output 18. (3) Other adjustments, such as AMPL 12 can be made by adjusting the AMPL 12 knob for attenuation; adjust Offset 11 for DC level; rotate the Duty 9 knob to change the output signal of the pulse or ramp waveform etc.. 5-7. Precaution item (1) Adjusting the DC OFFSET, will provide a change to the voltage of ±10V (no load) or ±5V (50Ω load). However, if a signal is added the DC level, is still limited to ±20V (no load) or ± 10V (50Ω load). In case of over-voltage, the waveform will be clipped and appear as shown in Figure 2. (2) Output connector label 50 Ω, indicated that the signal source impedance is 50Ω. To avoid oscillation, the connecting line should be as short as possible. (3) When adjusting the Duty knob anticlockwise, the ratio of positive state to negative state, expands to not less than 80:20. It can expand the square wave to pulse wave, the triangle wave to ramp wave and sine wave to unsymmetrical sine wave. As shown in Figure 3 the adjustment of the Duty control to obtain required waveform. www.tenma.com 16 www.tenma.com 17

Figure 2. 6. MAINTENANCE The following instructions should be used by a qualified person only. To avoid electrical shock, do not perform any service other than that contained in the operation instructions unless you are qualified to do so. 6-1.Fuse Rating and type If the fuse blows, the TENMA 72-7710 FUNCTION GENERATOR will not operate. Try to determine and correct the cause of the blown fuse, then replace the fuse with correct rating and type shown as below: Figure 3. FUSE Rating and Type Rating Input 115V 230V Watts VA T 0.315A 250V T 0.16A 250V 25 32 WARNING: For continued protection against fire, replace only with 250V fuse of the specified type and rating, and disconnect the power cord before proceeding fuse replacement. www.tenma.com 18 www.tenma.com 19

6-2.Fuse Replacement Procedure If you wish to replace the fuse, the upper cover must be removed according to the following steps: 2). Pull apart the handle from the Function Generator. Please turn the handle left and right side slightly; this will make it easier to pull off the handle. 1). The handle must be turned downward 90 degrees first. 3). There are two washers inside of the two holes (the joints of handle and case) respectively. Use a screwdriver to pry open these washers. www.tenma.com 20 www.tenma.com 21

4). Use a screwdriver to open the screw located at upper side of rear panel. Therefore, the upper cover can pull toward the backside. In the meantime, the upper cover is moved. Note: To replace the upper cover, please reverse above steps. 7-3. Cleaning To keep the instrument clean, wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. www.tenma.com 22