Implementation of Resistor based Protection Scheme for the Fault Conditions and Closed Loop Operation of a Three-Level DC-DC Converter

Similar documents
Protection Schemes for Various Fault Conditions of Three Level Dc -Dc Converters Jasirah.K.B 1, Atrhira.P.C 2

Comparison and Simulation of Full Bridge and LCL-T Buck DC-DC Converter Systems

Soft Switching with Cascaded Transformers to Drive the PMDC Motor

Implementation of an Interleaved High-Step-Up Dc-Dc Converter with A Common Active Clamp

FIVE LEVEL DC-DC CONVERTER WITH ASYMMETRICAL CONTROL STRATEGY FOR HIGH POWER APPLICATIONS

K.Vijaya Bhaskar. Dept of EEE, SVPCET. AP , India. S.P.Narasimha Prasad. Dept of EEE, SVPCET. AP , India.

Simulation and Analysis of Zero Voltage Switching PWM Full Bridge Converter

A HIGHLY EFFICIENT ISOLATED DC-DC BOOST CONVERTER

Soft-Switching Two-Switch Resonant Ac-Dc Converter

Voltage Balancing Control of Improved ZVS FBTL Converter for WECS

Soft switching of multioutput flyback converter with active clamp circuit

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

A New Phase Shifted Converter using Soft Switching Feature for Low Power Applications

A Component-Reduced Zero-Voltage Switching Three-Level DC-DC Converter Qin, Zian; Pang, Ying; Wang, Huai; Blaabjerg, Frede

IN THE high power isolated dc/dc applications, full bridge

Linear Transformer based Sepic Converter with Ripple Free Output for Wide Input Range Applications

High Frequency Soft Switching Of PWM Boost Converter Using Auxiliary Resonant Circuit

One-Cycle Control of Interleaved Buck Converter with Improved Step- Down Conversion Ratio

A LLC RESONANT CONVERTER WITH ZERO CROSSING NOISE FILTER

Comparison of Simulation and Experimental Results of Class - D Inverter Fed Induction Heater

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

Implementation of Single Stage Three Level Power Factor Correction AC-DC Converter with Phase Shift Modulation

Analysis and Design of Soft Switched DC-DC Converters for Battery Charging Application

Narasimharaju. Balaraju *1, B.Venkateswarlu *2

TYPICALLY, a two-stage microinverter includes (a) the

ZCS-PWM Converter for Reducing Switching Losses

A NOVEL SOFT-SWITCHING BUCK CONVERTER WITH COUPLED INDUCTOR

Page 1026

ISSN Vol.05,Issue.08, August-2017, Pages:

Improved Step down Conversion in Interleaved Buck Converter and Low Switching Losses

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

Implementation of Voltage Multiplier Module in Interleaved High Step-up Converter with Higher Efficiency for PV System

A Novel Soft Switching Lcl-T Buck Dc Dc Converter System

Simulation of Soft Switched Pwm Zvs Full Bridge Converter

Performance Enhancement of a Novel Interleaved Boost Converter by using a Soft-Switching Technique

CHOICE OF HIGH FREQUENCY INVERTERS AND SEMICONDUCTOR SWITCHES

Modular Multilevel Dc/Dc Converters with Phase-Shift Control Scheme for High-Voltage Dc-Based Systems

Resonant Inverter. Fig. 1. Different architecture of pv inverters.

A Double ZVS-PWM Active-Clamping Forward Converter: Analysis, Design, and Experimentation

1 Introduction

3SSC AND 5VMC BASED DC-DC CONVERTER FOR NON ISOLATED HIGH VOLTAGE GAIN

CHAPTER 3 MODIFIED FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER

Figure.1. Block of PV power conversion system JCHPS Special Issue 8: June Page 89

새로운무손실다이오드클램프회로를채택한두개의트랜스포머를갖는영전압스위칭풀브릿지컨버터

A Novel Technique to Reduce the Switching Losses in a Synchronous Buck Converter

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

A Novel Bidirectional DC-DC Converter with Battery Protection

A HIGH STEP UP RESONANT BOOST CONVERTER USING ZCS WITH PUSH-PULL TOPOLOGY

A New Interleaved Three-Phase Single-Stage PFC AC-DC Converter with Flying Capacitor

Improvements of LLC Resonant Converter

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Half bridge converter with LCL filter for battery charging application using DC-DC converter topology

Full Bridge DC-DC Step-Up Converter With ZVZCS PWM Control Scheme

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP ( 81

EMBEDDED CONTROLLED ZVS DC-DC CONVERTER FOR ELECTROLYZER APPLICATION

The Parallel Loaded Resonant Converter for the Application of DC to DC Energy Conversions

PSIM Simulation of a Buck Boost DC-DC Converter with Wide Conversion Range

Anfis Based Soft Switched Dc-Dc Buck Converter with Coupled Inductor

A Bidirectional Series-Resonant Converter For Energy Storage System in DC Microgrids

AN EFFICIENT CLOSED LOOP CONTROLLED BRIDGELESS CUK RECTIFIER FOR PFC APPLICATIONS

Hybrid Transformer Based High Boost Ratio DC-DC Converter for Photovoltaic Applications

Design of Series Connected Forward Fly Back Step up Dc-Dc Converter

A New Full Bridge DC/DC Converter Topology with ZVZCS Features

Matlab /Simlink based closed Loop Control of Bi-Directional DC - DC Converter

Simulation and Performance Evaluation of Closed Loop Pi and Pid Controlled Sepic Converter Systems

Single Phase AC Converters for Induction Heating Application

Webpage: Volume 3, Issue IV, April 2015 ISSN

Resonant Converter Forreduction of Voltage Imbalance in a PMDC Motor

NOVEL TRANSFORMER LESS ADAPTABLE VOLTAGE QUADRUPLER DC CONVERTER WITH CLOSED LOOP CONTROL. Tamilnadu, India.

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

DUAL BRIDGE LLC RESONANT CONVERTER WITH FREQUENCY ADAPTIVE PHASE-SHIFT MODULATION CONTROL FOR WIDE VOLTAGE GAIN RANGE

Integration of Two Flyback Converters at Input PFC Stage for Lighting Applications

A NEW SOFT-SWITCHING ACTIVE CLAMP SCHEME FOR FULL-BRIDGE ISOLATED CURRENT FED DC-DC CONVERTER FED DRIVES

GENERALLY, a single-inductor, single-switch boost

Proceedings of the 7th WSEAS International Conference on CIRCUITS, SYSTEMS, ELECTRONICS, CONTROL and SIGNAL PROCESSING (CSECS'08)

The Feedback PI controller for Buck-Boost converter combining KY and Buck converter

Novel Zero-Current-Switching (ZCS) PWM Switch Cell Minimizing Additional Conduction Loss

Closed Loop Controlled Low Noise SMPS System Using Forward Converter

Non-isolated DC-DC Converter with Soft-Switching Technique for Non-linear System K.Balakrishnanet al.,

Hybrid Full-Bridge Half-Bridge Converter with Stability Network and Dual Outputs in Series

Asymmetrical Half Bridge Double Input DC/DC Converter Adopting More Than One Renewable Energy Sources

Novel Soft-Switching DC DC Converter with Full ZVS-Range and Reduced Filter Requirement Part I: Regulated-Output Applications

Student Department of EEE (M.E-PED), 2 Assitant Professor of EEE Selvam College of Technology Namakkal, India

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

Analysis and Design of a Bidirectional Isolated buck-boost DC-DC Converter with duel coupled inductors

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

A Single Switch High Gain Coupled Inductor Boost Converter

A LC PARALLEL RESONANT CONVERTER FOR GRID-CONNECTED RENEWABLE ENERGY SOURCES

ZVS IMPLEMENTATION IN INTERLEAVED BOOST RECTIFIER

A NEW HIGH EFFICIENCY HIGH POWER FACTOR INTERLEAVED THREE-PHASE SINGLE-STAGE AC DC CONVERTER WITH FLYING CAPACITOR

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: 2-4 July, 2015

A Merged Interleaved Flyback PFC Converter with Active Clamp and ZVZCS

Modified Buck-Boost Converter with High Step-up and Step-Down Voltage Ratio

Design and Hardware implementation of Two Phase Coupled InductorInterleaved Boost Converter with Low Ripple Circuit

INSULATED gate bipolar transistors (IGBT s) are widely

DC-DC Resonant converters with APWM control

Soft-Switching Active-Clamp Flyback Microinverter for PV Applications

Bridgeless Cuk Power Factor Corrector with Regulated Output Voltage

ISSN Vol.07,Issue.06, July-2015, Pages:

CLOSED LOOP CONTROL OF THE Z SOURCE RESONANT CONVERTER FOR THE ELECTRIC VEHICLE WIRELESS CHARGER Shwetha K B 1, Shubha Kulkarni 2 1

Transcription:

Research Article International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347-5161 2014 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Implementation of Resistor based Protection Scheme for the Fault Conditions and Closed Loop Operation of a Three-Level DC-DC Converter Sandra M Ȧ* and Venkatesh R Ȧ Ȧ Department of EEE, SNS College of Engineering, Coimbatore, India Accepted 20 April 2014, Available online 30 April 2014, Vol.4, No.2 (April 2014) Abstract Abnormal conditions or faults may occur in the circuit due to inherent problem of the devices connected to the circuit or may due to some external factors. Hence there is a chance for the occurrence of fault even in carefully designed circuits. The implementation of protection scheme is always desirable for any power converter. In this paper, the conditions which can create abnormal voltage stresses in the circuit are initially investigated and analyzed, there after a resistor based protection scheme is implemented for each faulty condition. Closed loop operation of parallel resonant converter is also designed. Design, simulation development and study were accomplished using MATLAB Simulink tool box. Keywords: Input capacitors, flying capacitors, fault (abnormal conditions), protection, three-level dc-dc converter, parallel resonant converter 1. Introduction 1 Power electronic systems always demand for reliable, improved quality, small, lightweight and highly efficient power supplies. For low power applications linear regulators can provide output of better quality. Electronic devices in linear regulators operate in their active modes, meanwhile the higher power levels uses switching regulators. Switching regulators use power electronic semiconductor switches in ON and OFF states. Normally during ON state, there will be low voltage across a switch and in the OFF state no current flow will occur through switch. High energy conversion efficiency can be achieved by using switching regulators. Operating frequency and size of components are dependent on each other. Higher the operating frequency, smaller the transformer, inductors and capacitors. Therefore to achieve faster dynamic response to rapid change in load current and input voltage, high operating frequency are preferred. Power electronic often operate from utility mains and hence they are exposed to the disturbances associated with it. Owing to the disturbances, several protection scheme must be implemented for the protection of converters. It is necessary to protect the main terminals and the control terminals. Some of these techniques are common for all devices and converters. However difference in essential features of devices call for special protection scheme ( H.S. Choi and D.Y.Huh et al, 2004 ), ( E. R. da Silva,W. S. Lima, A. S. de Oliveira, C. B. Jacobina, and H. Razik et al, 2006). In this paper, parallel resonant converter is taken as an example the conditions which can create abnormal *Corresponding author Sandra M is a PG Scholar and Venkatesh R is working as Asst Prof voltage stresses in the three-level parallel resonant converter circuit are initially investigated and analyzed, there after a resistor based protection scheme is implemented for each faulty condition. Fig.1. shows the topology of parallel resonant converter. Furthermore, it is possible to protect the system from various faults by the protection scheme through the monitoring of flying capacitor voltage. Fig.1.Topology of a three-level parallel resonant converter One of the advantage of three-level DC-DC converter is that lower voltage rating switches with better performance can be used owing to the withstanding capability of input capacitor to half of the supply voltage. To ensure proper operation there should be balanced voltage across the input capacitors. A flying capacitor is added to achieve true ZVS (F. Canales, P. Barbosa, and F. C. Lee et al, 2002), (F. Canales, P. M. Barbosa, and F. C. Lee et al, 2000), (J. A. Carr, B. Rowden, and J. C. Balda et al, 2009) under phase shift control. The flying capacitor can help to 1129 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)

decouple the switching transition between outer two switches (S 1 and S 4 ) and the inner two switches (S 2 and S 3 ). Turning OFF of outer switch causes the charging of parallel capacitor to it and at the same time, there occur discharging in the capacitor which is connected in parallel to the other outer switch. This is the way the Zero Voltage Switching (ZVS) ( K. Jin and X. Ruan et al, 2007), (X. Ruan, D. Xu, L. Zhou, B. Li, and Q. Chen et al, 2002), (X. Ruan, Z. Chen, and W. Chen et al,2005) is achieved. For inner switches the flying capacitor will act as a snubber capacitor during the normal operating period, voltage across the flying capacitor, Vcss will be half of the input voltage. The basis for the fault identification is the variation the flying capacitor voltage from its balanced condition. Earlier neutral point protection method is used for the fault diagnosis. The disadvantage of neutral point protection is its less sensitivity. The proposed protection method is based on the detection of voltage across flying capacitor, Vcss. The advantages of this protection scheme include: Since there is no need of any additional components the converter operation will remain unaffected Sensitivity to unbalanced switch voltages and the ability to detect multiple faults. Fast response time that is very critical in short-circuit and shoot-through protection. Low cost and easy implementation. Can replace under/over input voltage lockout 2. Categorization of unbalanced voltage stresses There after the flying capacitor will become parallel to that particular input capacitor this has more voltage stress. Flying capacitor helps to alleviate the voltage unbalance of the input capacitors. The flying capacitor voltage will be charged to the peak voltage of the input capacitor inspite of neutral point voltage, which may be higher or lower than Vin/2 or which input capacitor has high voltage. Unbalanced input capacitor voltages will results in abnormal flying capacitor voltages. Unequal capacitances of input capacitors, unbalanced duty cycles, mismatched switching timings etc bring abnormality in the circuit. Moreover, even if the voltages across the input capacitors are balanced, the Vcss still can be influenced by the voltage ripple on the input capacitor. According to the earlier analysis, the peak voltage on the input capacitor will pump energy to the flying capacitor. Fig.2. Charging loop when the voltage of Cin1 is higher than half of the input voltage. Good knowledge about the converter operation and faults in the circuits are necessary to design the protection scheme. Mainly the abnormal conditions are categorized into three, it includes: 2.1 Abnormal Input Capacitor Voltages Due to Input Voltage In order to split the input voltage equivalently and the neutral point, Point b in Fig.1, which has a voltage of half the input voltage, two input capacitors (Cin1 and Cin2) are needed. So the neutral point voltage and the voltage across flying capacitor, Vcss depends on the input voltage. Hence by monitoring the flying capacitor voltage, Vcss it is possible to analyze the over/under input voltage variation under abnormal input voltage conditions. Fig.3. Charging loop when the voltage of Cin2 is higher than half of the input voltage. 2.2 Abnormal Input Capacitor Voltages Due to Unbalanced Neutral Point Voltage Unbalanced voltage is another problem, which will bring abnormality in the input capacitor voltages. Charging of flying capacitor takes place through clamping diodes (Dc1 and Dc2). Flying capacitor will get charged through down clamping diode, Dc2 when the voltage across Cin1 is higher than half the input voltage, Vin/2, shown in Fig.2. Likewise, through the upper clamping diode, Dc1 the flying capacitor will get charged when Cin2 voltage is higher than half the input voltage, Vin/2, shown in Fig.3. Fig.4.Charging loop for wrong operation mode of ZCS instead of ZVS. 1130 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)

2.3 Losing Discharging Path Even With Normal Input Capacitor Voltages The flying capacitor is charged is through clamping diodes Dc1 (or S1) and Dc2 (or S4) under normal operation. The only possible path of discharging for flying capacitors is through S2 or S3. In some abnormal conditions the flying capacitor will get charged through S2 or S3 instead of discharging, thus the flying capacitor voltage will increase and crosses the safe range of operation. When the ZVS operation is desired, the commutation of the phase shift provides a discharge loop for flying capacitors. The flying capacitor will get charged instead of being discharging when the converter loses ZVS(such as light load or when S2 is turned OFF before S1 or S3 is turned OFF before S4).In all these cases, the voltage across flying capacitor will increased nearly to input voltage. Fig.4 shows accidental ZCS operation mode instead of ZVS. At light load conditions, ZVS operations for both lagging and leading switch losses and mechanism becomes as same as the ZCS condition. ZVS has to be ensured even in light load to heavy load condition. Fig.5 shows a case of reverse switching timing. Turning OFF of S2 before S1 makes the upper side of the flying capacitor connected to the input voltage through s1 and lower side of the flying capacitor is connected to the ground through the body diode of S4. Hence a voltage equal to the input voltage will appear across the flying capacitor. In order to overcome this issue a proper and correct switching sequence has to be assured. 3. Multiple faults in the three-level converter In this section, the variation of voltage across flying capacitor, Vcss in response to various abnormal condition is explained. The most common faults associated with the active devices and load, includes open- short circuit of inner and outer switches, open - short circuit of clamping diodes, open-short circuit of antiparallel diodes D1 and D2, open- short circuit of rectifier diode Dr1 and finally, open-short circuit of load. When the main switch is MOSFET, its body diode is commonly used as antiparallel diode instead of the external diode. Any failure to the body diode will affect the functioning of main switch. Fig.6. shows the most common faults associated with three-level parallel resonant converter. 3.1 Outer Switch Open Circuit Consider the case with outer switch s1 open circuited and the switches s3 and s4 in ON state. Since the inductive current loop in the circuit is remaining as undisturbed, there will occur continuous energy flow to the load from bottom capacitor, Cin2. But once S2 is turned ON along with that S3 and S4 are turned OFF, the upper input capacitor will get isolated, this is due to the short circuit loop for the inductor current by the upper clamping diode (Dc1).It is illustrated in Fig.7, this will create unbalanced voltage across the flying capacitor. Owing to the negative biased dc voltage stress, the transformer will get saturated. Fig.6. Possible faults on the three-level parallel resonant converter. 3.2 Outer Switch Short Circuit Consider the case outer switch short circuited with switches S3 and S4 ON. If S1 is short circuited, the voltage across the flying capacitor becomes equal to the input voltage due to the direct connection of flying capacitor to the input power source. This fault is independent of the neutral point voltage. Fig.5.Charging loop due to reverse switching timing. Fig.7. S1 has an open circuit when S3 and S4 are OFF. 3.3 Inner Switch Open Circuit In case of occurrence of open circuit of inner switch(say S2) input voltage,as a whole will appear across the flying capacitor through the outer switch,s1 and the body diodes of S3 and S4,shown in Fig.8. Open circuit of S2 violate the rule that s1 has to turn OFF before S2 turns OFF. Due to this fault no power is delivered to the load. 1131 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)

3.4 Inner Switch Short Circuit Consider the inner switch (say S2) short circuit with S3 and S4 ON. Owing to this condition flying capacitor and bottom input capacitor (Cin2) will get shorted. The flying capacitor will get shorted through switches S2 and S3, and bottom input capacitor will get shorted through the upper clamping diode and switches S2, S3 and S4, shown in the Fig.9. When S3 and S4 turn OFF, flying capacitor and bottom input capacitor will get charged to half of the input voltage with a frequency equal to the switching frequency. Faults caused due to this condition do not affect the converter operation. Positive biased voltage causes transformer saturation. practically lose the advantages of the three-level structure. The fault can be analyzed by monitoring the voltage across the flying capacitor as long as the unbalanced switch voltage stresses persists. 3.7 Clamping Diode Short Circuit When there occur short circuit in the clamping diode with switch S1 ON, the neutral point voltage will be connected with the positive polarity of the input voltage and charged to full input voltage. Under this fault condition, when S1 is ON it will suffers huge current, or then S2 suffers overvoltage when it is OFF. Either one could fail before the neutral point voltage or the voltage across the flying capacitor, Vcss will become equal to the input voltage. The transformer suffers a negative dc bias voltage owing to this. Fig.8. S2 has an open circuit when S1 is ON. Fig.10. D1 has an open circuit when S4 starts to turn OFF while S3 is still ON Fig.9. S2 has a short circuit when S2 and S4 are ON. 3.5 Outer Switch Body Diode Open Circuit Consider the case with open circuit occurred to the body diode,d1 of outer switch S1. Fig.10 shows when S4 turns OFF and S3 is still ON, the inductor current will go through the bottom clamping diode back to the resonant tank instead of D1 after the S4 s switch capacitor is charged to half of the input voltage and S1 s switching is discharged to ZERO. The outer switch S1 s body diode D1 will never conduct. The circuit operation remains unaffected by this fault. Detecting this fault by monitoring flying capacitor is not easy task. 3.6 Clamping Diode Open Circuit If the clamping diode Dc1 fails due to open circuit, the operation of converter will remain unaffected shown in Fig.11. But without the clamping diode the converter will Fig.11. D2 has an open circuit when S3 and S4 turn OFF. 3.8 Rectifier Diode Open circuit When the rectifier diode Dr1 fails due to open circuit, energy transferred to the load under positive resonant capacitor voltage will cease. But the converter keeps transferring the energy to the load when the resonant capacitor is negative. This unbalanced energy transfer will result in a positive dc biased voltage stress to the transformer. Finally the neutral point voltage will drops to zero while the voltage across flying capacitor, Vcss increases to the full input voltage. If the rectifier diode in opposite bridge is open circuit the neutral point voltage will increase and also the flying capacitor voltage, Vcss. 1132 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)

Transformer primary open circuit Occurrence of primary winding of transformer open circuit may due to mechanical and thermal stresses in the transformer winding, finally it affect the insulation of transformer cooling system. The fault results in the unbalanced voltage across the flying capacitor,vcss. 3.9 Transformer primary short circuit This fault may occur due to bushing flash over and also due to faults in tap changer equipments. Thus the transformer must be isolated instantly during fault, otherwise electrical failure will occur to the system, Finally increase the flying capacitor voltage,vcss. 3.10 Transformer secondary open circuit Whenever the secondary windings experience stresses due to some external or internal factors, there may occur secondary side open circuit. This will results in deviation of flying capacitor voltage, Vcss from its balanced condition. 3.11Transformer secondary short circuit Arcing ground if neutral point is isolated or switching operation of different electrical equipments may results in surge voltage, it causes breakdown in the insulation between turns adjacent to the line terminal which may create short circuit between turns of secondary windings. This fault results in increased current in the circuit, obviously the flying capacitor voltage increases. The transformer suffers a positive bias voltage due to this fault. 4. Closed loop operation of a parallel resonant converter flying capacitor will perform the following functions: Decoupling the switching transition between inner and outer switches. Maintaining balanced voltage across the input capacitors. For inner switches it can act as a snubber capacitor Vcss can be calculated with the following: ( 1 K) Vcss V in (1) 2 Where V in is the input voltage,and k is the allowed voltage ripple percentage for input capacitors, which usually determined by (2). This can explain why the Vcss increases slightly even in a normal operation 2 * IO k.100% (2) C * f * V * V * in s 6. Simulation results in in A three-level parallel resonant converter was simulated using MATLAB software with 600V dc input voltage and 200 khz switching frequency. 600V voltage rating MOSFET modules are used as main switches. Table 1 parallel resonant converter circuit key parameters Parameters Values Input DC source voltage 600V Input capacitors(v Cin1 & V Cin2 ) 10µF Flying capacitor(css) 2µF Resonant capacitor(cp) 1.24nF Resonant inductor(lr) 3.63µH Transformer turn ratio 1:11 Fig.12. shows the closed loop circuit for parallel resonant converter. The closed loop system includes comparator and PI controller. The output voltage is sensed and it is compared with the the reference voltage. The error signal is applied to the PI controller. The output of PI controller is given to the MOSFET. The steady state error can be reduced by properly tuning of the PI controller. Figure.13. shows the response of closed loop system. 5. Design of proposed circuit For three-level structures, balance resistors are needed for the capacitors voltage balance. The value of the potential resistor must be less than the circuit resistivity. Resistor based protection circuit is implemented with resistors of 0.018. 5.1 Flying Capacitor Design Though the flying capacitor design is not directly related with the protection circuit design, the proposed protection method has to be based on the flying capacitor. In the conventional three level converter with phase-shift control, Fig.12. closed loop circuit for parallel resonant converter The abnormal conditions which cause failures in the circuit was successfully protected by the proposed protection scheme. The fault conditions are generated by a timer and a fault signal. Based on previous analysis, the flying capacitor voltage is also abnormally increased. 1133 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)

Therefore, the proposed protection is triggered and successfully protects the converter against the system failure. Fig.12 below shows the Simulink model of the parallel resonant circuit. Fig.13. Response of closed loop parallel resonant converter Fig.17.Simulation output with inner switch short circuit Fig.14. Simulink model of three-parallel resonant converter Fig.18. Simulation output of protection circuit with inner switch short circuit Conclusion Fig.15 Simulation output under transformer primary open circuit A protection scheme based on flying capacitor voltage detection and closed loop operation of parallel resonant converter is presented in this paper. The proposed protection scheme helps to implement a resistor based protection method for three-level parallel resonant converter by monitoring flying capacitor voltage. It is simple, can be implemented easily with fast response time and also cost efficient. Since there is no addition on the power stage, converter performance and operation will remain unaffected. The protection method can effectively avoid the device failure caused by unbalanced voltage stresses on switches in the three-level structure, and will protect the system even if abnormal condition persists. Closed loop operation is determined for getting desired output even in varying input conditions. The theoretical analysis and simulation results are verified by experimental results. References Fig.16. Simulation output of protection circuit with transformer primary open circuit F. Canales, P. Barbosa, and F. C. Lee (2002), A zero voltage and zero current switching three level DC/DC converter, IEEE Trans. Power Electron., vol. 17, no. 6, pp. 898 904 F. Canales, P. M. Barbosa, and F. C. Lee (2000), A zero-voltage and zero-current- switching three level dc/dc converter, in Proc. IEEE Appl. Power Electron. Conf., pp. 173 178. J. A. Carr, B. Rowden, and J. C. Balda (2009), A three-level fullbridge zero-voltage zero-current switching converter with a 1134 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)

simplified switching scheme, IEEE Trans. Power Electron., vol. 24, no. 2, pp. 329 338. H.S. Choi and D.Y.Huh (2004), Protection schemes for various fault conditions for off-line flyback converters, in Proc. IEEE Power Electron. Spec. Conf., vol. 6, pp. 4355 4359. E. R. da Silva,W. S. Lima, A. S. de Oliveira, C. B. Jacobina, and H. Razik (2006), Detection and compensation of switch faults in a three level inverter, in Proc. IEEE Power Electron. Spec. Conf., pp.1 7. P. Hao and D. Maksimovic (2006), Overload protection in digitally controlled DC-DC converters, in Proc. IEEE Power Electron. Spec. Conf., pp. 16. Y. Jang and M. M. Jovanovic (2005), A new three-level softswitched converter, IEEE Trans. Power Electron., vol. 20, no. 1, pp. 75 81. K. Jin and X. Ruan (2007), Zero-voltage-switching multi resonant three-level converters, IEEE Trans. Ind. Electron., vol. 54, no. 3, pp. 1705 1715. J. R. Pinherio and I. Barbi (1992), The three-level ZVS PWM converter A new concept in high-voltage dc-to-dc conversion, in Proc. IEEE IECON Conf., pp. 173 178. X. Ruan, D. Xu, L. Zhou, B. Li, and Q. Chen (2002), Zerovoltage-switching PWM three-level converter with two clamping diode, IEEE Trans. Power Electron., vol. 49, no. 4, pp. 790 799. X. Ruan, Z. Chen, and W. Chen (2005), Zero-voltage-switching PWM hybrid full-bridge three-level converter, IEEE Trans. Power Electron.,vol. 20,no. 2, pp. 395 404. 1135 International Journal of Current Engineering and Technology, Vol.4, No.2 (April 2014)