Construction Manual of Merlin spectrometer

Similar documents
Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

OPTICAL BENCH - simple type

Optical Spectrometer using a Linear CCD image sensor

PRINCIPLE PROCEDURE ACTIVITY. AIM To observe diffraction of light due to a thin slit.

Build Spectroscope. This activity is suitable for Middle School or High School Students. State Standards Met

Name:.. KSU ID:. Date:././201..

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

University of Wisconsin Chemistry 524 Spectroscopic Components *

Make Your Own Digital Spectrometer With Diffraction Grating

The Shoebox spectrograph construction and lab investigations. By Timothy Grove

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

Improving the Collection Efficiency of Raman Scattering

Circuit Board Assembly Instructions

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

LITTLE NERD v1.1 Assembly Guide

Unit 8: Light and Optics

Miniature Spectrometer Technical specifications

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

LEOK-3 Optics Experiment kit

Physics 2306 Fall 1999 Final December 15, 1999

PhysicsAndMathsTutor.com 1

Patton Robotics, LLC.

PH 481/581 Physical Optics Winter 2013

MP573 Assembly guide. Soldering. MP573 Assembly guide PCB split PCB split. Document revision 2.2 Last modification : 22/08/17

PHYS 241 FINAL EXAM December 11, 2006

LOS 1 LASER OPTICS SET

Exam 3--PHYS 2021M-Spring 2009

Never power this piano with anything other than a standard 9V battery!

PH 481/581 Physical Optics Winter 2014

Introduction to the operating principles of the HyperFine spectrometer

Supplementary Materials

Be aware that there is no universal notation for the various quantities.

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

3. Assembly manual ANALYZING THE PCB'S LCD PCB. Component side: Solder side:

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

Instructions for the Experiment

Dumpster Optics THE COLORS OF LIGHT

User s Guide Optical Isolator Alignment Procedure

YOUNGS MODULUS BY UNIFORM & NON UNIFORM BENDING OF A BEAM

Physics 248 Spring 2009 Lab 1: Interference and Diffraction

Physics review Practice problems

3B SCIENTIFIC PHYSICS

TekBot Remote Control Receiver Board Construction

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Final Reg Optics Review SHORT ANSWER. Write the word or phrase that best completes each statement or answers the question.

Onwards and Upwards, Your near space guide

PHYS General Physics II Lab Diffraction Grating

kitsch-bent > el_dmg ver. 1 3/25/2012 kitsch-bent.com

No Brain Too Small PHYSICS

CECS LAB 4 Prototyping Series and Parallel Resistors

UNIVERSITY OF HAWAII Institute for Astronomy. f/31 High Angular Resolution Imaging Spectrograph HARIS USER MANUAL update June 10, 1997

S.No Description/Specifications Qty 01. Post office box Trainer.

Measuring with Interference and Diffraction

Build your own boombox

Dual Band Filter Assembly Manual

3B SCIENTIFIC PHYSICS

Exercise 8: Interference and diffraction

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

How-to guide. Working with a pre-assembled THz system

OpenROV. Guide 3 - Electronics. We will now move to the assembly of the electronics that will control the ROV. Written By: OpenROV

SS-A5 SERIES SH SERIES

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Spatial Light Modulator (SLM) Workshop, BFY 2012 Conference Douglas Martin and Shannon O Leary Lawrence University and Lewis & Clark College

SPECTROCLICK KIT EXPLORE THE INTERACTION OF LIGHT AND MATTER THE SCIENCE OF SPECTROSCOPY. 101 W. Tomaras Ave. Bldg.

Chapter 34 The Wave Nature of Light; Interference. Copyright 2009 Pearson Education, Inc.

Practice Problems for Chapter 25-26

Unit 5: Designing with Data (Safer Buildings) Contents

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

STEM Society Meeting, April 10, 2012

Durst HL 2506 AF. Durst HL 2506 AF

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

Raman Microscope Attachment

Assembly Instructions: Kit #5

Part 5-1: Lithography

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS

D.I.Y L.E.D CUBE 4X4X4. Level: Intermediate

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Chapter 36: diffraction

Mini-spectrometer from a DVD and folded paper

IBIL setup operation manual for SynerJY software version

4ms SCM Breakout. Kit Builder's Guide for PCB v2.1 4mspedals.com

Circuit Board Assembly Instructions for Babuinobot 1.0

HT-1A Dual Band CW QRP Transceiver. Kit Building Instructions

Tek-Bot Remote Control Transmitter Board Construction

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

DC Motor. Controller. User Guide V0210

Chapter 4: Fourier Optics

Figure 1. CheapBot Line Follower

Mirrors and Lenses. Images can be formed by reflection from mirrors. Images can be formed by refraction through lenses.

IR add-on module circuit board assembly - Jeffrey La Favre January 27, 2015

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Option G 4:Diffraction

1/8 m GRATING MONOCHROMATOR

Transcription:

Construction Manual of Merlin spectrometer The first generation of our Merlin Spectrometer is based on the ramanpi Spectrometer. The Project was developed open source with a detailed construction documentation. In the link below you will find some details. https://hackaday.io/project/1279-ramanpi-raman-spectrometer/log/9583-how-to-build-aspectrometer In the working progress we optimized Merlin for our challenges, added some features for calibration, sample handling and other adjustments. In the following part list you will find everything you need for your very own Merlin spectrometer. Furthermore you need access to a 3D-printer to print your spectrometer casing and other components. 1

Step by step preparations and assembly Attention! The diffraction grating and the mirrors should be handled carfully. We recommend disposable gloves and hexagon socket screws to prevent scratches and fingerprints. Be careful when preparing the gap. When working with the shaving blades and the magnet you can easily cut yourself. First step - download and get started with the 3D-prints Download every print-file on our website for your own spectrometer and print Merlins spectrometer casing. After printing remove all unnecessary support structures and free every srcew hole. Before all components are installed, it is recommended to put all screws into the housing. Furthermore you need to print the two mirror holders, the diffraction grating mount, and the frame for the CCD modul. Second Step - fixing optical components to the corresponding holders Fix the optical components to the corresponding sockets with double-sided adhesive tape. The fixation is secured with a little glue. The diffraction grating frame is secured in the lower area between the frame and the case with a round thin latex strip. The rubber ring is removed from a disposable glove and ensures the security and rotation for later calibration. Third Step - Prepare slit or small hole For a narrow gap, two razor blades (7mm * 15mm) are cut out of a razor blade with scissors covering the hole of the magnet to create a fine gap with the desired gap width. The gap is fixed with scotch film without sticking over the gap. For a small square hole, work is done equivalently with four cut razor blades. Optimize the gap width for your requirements and note that as the gap size decreases, the spectral resolution increases and the intensity decreases. 2

Fourth step - CCD modul Complete the TCD1304 Linear CCD module following the instructions of Esben Rossel. His detailed instructions can be found in the following link: https://hackaday.io/tvaettbjoern We used a Otter T1304 PCB board, which has the same port constellation as Esben Rossel s second SMD-Version. For the PCB board you will need resistors, capacitors, ports; IC, Transistors with following specifications (table 1).To make the depths of the CCD sensor adjustable, we inserted two layers of the socket strips. We recommend to provide the six jumper cables with markings for the connections. Table1 specifications fort he CCD modul R1; R2 150Ω SMD 1206 R3 2,2 kω SMD 1206 C1; C3 0,1 μf SMD 1206 C2 10 μf SMD 1206 T1 2SA1015-Y IC1 TC74HC04 SMD 1206 CCD TCD1304 Socket strips1 (ST1) 4x 11 Female headers BLY 1 Socket strips2 (ST2) 2x 5 Female headers BLY 1 PCB board The Otter TCD1304 board 6 jumper cables Figure1: Interior view of the PCB board within Merlin on which the ccd sensor is placed on a two-layer socket strips1 (ST1). In the link below you can find more details about the PCB board: http://dirtypcbs.com/store/details/863/the-otter-tcd1304-board 3

Table2 How to connect the CCD modul with the nucleo 1 fm connects to PB0 (A3) 2 SH connects to PA1 (A1) 3 ICG connects to PA0 (A0) 4 OUTPUT (OS) connects to PC0 (A5) 5 +5V connects to +5V 6 GND connects to GND Figure 2: The corresponding external view of the PCB board within Merlin to which the IC1, C1, C2, C3, R1, R2, R3, T1 and the socket strips2 (ST2) are soldered. Fifth step - final assembly Upon completion of all preparations, all items can now be located at their intended location in the lower part of the spectrometer housing, as shown in figure 3. Figure 3: lower half of the Merlin spectrometer with built-in components. 4

Sixth step - calibration For coarse calibration, a laser with a defined wavelength is recommended. We used a laser with a wavelength of 650 nm and a power of 0.4 mw, which represents only a low risk for the eyesight. When calibrating with the slit and the above-mentioned laser, it is urgent for a good spectral resolution that the distance from the slit opening to the first small spherical mirror correspond exactly to the focal length of 8 cm so that the reflected light beam is collimated to the diffraction gratingthe distance between the large concave mirror and CCD sensor must also be adjusted with great care to the focal length of 10 cm. After appropriate adjustment of the distances and angles, a vertical narrow red stripe is imaged on the CCD sensor, which is located relatively far to the right of the sensor. A mercury lamp is excellently suited for calibration with its wide discrete light spectrum and provides information on which wavelength range is imaged on the CCD sensor. Each light source with known and constant light spectrum in the visible range is suitable for calibration of the Merlin spectrometer. When evaluating the measured values, it should be noted that the spectral response of the CCD sensor is not constant and drops significantly as of a wavelength of 700 nm. You can find more details in the link below: https://www.coptonix.com/html/laith_i_ccd.html Figure 4: Completed Merlin spectrometer with outer case, nucleo, Raspberry Pi and LCD display. 5

Figure 5: Ready-to-use Merlin spectrometer after fine calibration. After careful alignment and verification of the spectral resolution. Can the measurement signals be evaluated via a laptop or the Raspberry PI. Note, intensity peaks are inverted by the CCD sensor as valleys. Have fun and success with your Merlin spectrometer! 6