HTA125A/250A. Power Amplifiers. Installation & Use Manual

Similar documents
Classic Series Public Address Amplifiers C10 & C20 Models

Classic Series Public Address Amplifiers C10 & C20 Models

Model CC4041. CC Series Amplifier. Installation and Use Manual

Model CC4052. CC Series Amplifier. Installation and Use Manual

Classic Series Amplifiers C35, C60, & C100 Models

A Channel Amplifier

Black Max Amplifier X300, X450, & X600 Models

2BSST POWER AMPLIFIER OWNER S MANUAL

SPECIAL 6. 6-Watt Vacuum Tube Guitar Amplifier. User Manual

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

REVAMP4100 Instruction manual

REVAMP4120T Instruction manual

KLASIK NEAR FIELD ACTIVE STUDIO MONITOR

CLASS D STEREO AMPLIFIER 60 WPC. Model: APA102 User Manual

DPA-1.2. Instruction Manual. 2 Channel Amplifier with Auto A/B Selector DPA-1.2 DPA-1.2 POWER SERIAL # LINE INPUT SENSING SPEAKER B OUT

AV30MX-2 Operation Manual

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Power Vector Amplifiers V35, V60, V100, V150, & V250 Models

plifier D-501 otion Am Tactile M

M-300 Mono power amplifier User s guide

INSTALLATION MANUAL ECA-70VMINI-60W ECA-70VMINI-60W L VOLUME SPEAKER OUTPUTS 12VDC IN + L+ L- GND R+ R- S GND GND Tx Rx

MCP35A. Master Control Panel. Installation & Use Manual

AC-TX Volt/100 Volt Transformer Panel for VR61 and VR62 Loudspeakers and the CLA37 Column Loudspeaker AC-TX128

User Manual LMS-325 Line Monitor Speaker

PAM 1270 MULTI-ZONE AMPLIFIER OWNER S MANUAL WARRANTY & REPAIR

Carmen Ghia. Manual. Model: ZA-07.

AV25-2 User Manual. 1 Important safety instructions

EPA152/252/502. User Manual.

CR31. Companion. Instruction Manual

SVS SoundPath Wireless Audio Adapter Owner s Manual

Important Safety Information

IMPORTANT SAFETY INSTRUCTIONS

Big Bang. B B O w n e r s M a n u a l. Power Amplifiers. SpeakerCraft BB2125 POWER ACTIVE PROTECTION L

REVAMP2250 Instruction manual

EQ-AMP60 60W Mixer Amplifier

EPA104/254. User Manual.

INTEGRATED HYBRID TUBE AMPLIFIER VT Model HYBRID TUBE AMPLIFIER

A-16D A-Net Distributor

10 WATT GUITAR COMBO

Cover for IPA 75/150T II

875HT OWNER S MANUAL

3400 Watt Stereo Power Amplifier

Opus 21 s80 Integrated Amplifier Owner's Manual

MODEL A1. PackLite TM POWER AMPLIFIER

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

DA216S DISTRIBUTION AMPLIFIER

Q44/Q66 PROFESSIONAL AMPLIFIER OWNER S MANUAL

Mini-Z. Manual. Model: ZA-21.

R850MC. 4-Zone, 8-Channel Power Amplifier Installation Manual

1695T Black Magick. User Manual

Power Intercom Systems Models PI35A & SI35A

ENGLISH THANK YOU! DARK TERROR. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

MXA Series Mixer/Amplifiers

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

ENGLISH THANK YOU! OR15. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

CANARY AUDIO. EL34 Stereo Power Amplifier. Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA

IMPORTANT SAFETY INSTRUCTIONS

3BSST 4BSST POWER AMPLIFIER OWNER S MANUAL UPDATED

Dual Terror Owners Manual

MIXER POWER AMPLIFIER BG-130

3.Avoid spilling liquids or allowing materials to enter the cabinet

Primare A33.2 Amplifier User Guide

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

OWNER S MANUAL A

ENGLISH THANK YOU! TH100. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual

ENGLISH TERROR BASS 500/1000

HARMONY SINGER 2. Battery-Powered Vocal Effects Stompbox with Guitar-Controlled Harmony, Reverb and Tone. User Manual

AQ-SWA8-1BT - ACTIVE SUBWOOFER USER / INSTALLATION MANUAL. with Bluetooth & Full Range Speaker Outputs

OWNER S MANUAL CPS 3 / CPS 4 CONTRACTOR PRECISION SERIES

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

By: 500 Series Inductor EQ. Serial #: Operations Manual

The ART SLA-2 Studio Linear Amplifier

KeyPre KP6 - Electronic Instrument Preamplifier

w i t h T A B L E O F C O N T E N T S Safety Information 2 Certifications/Standards 3

Z-LUX. Manual. Model: ZA-38.

AT5XXNC CLASS D 2 TO 8-CHANNEL POWER AMPLIFIER OWNER S GUIDE

IMPORTANT SAFETY INSTRUCTIONS

Important Safety Information

Antidote. Manual. Model: ZA-35.

CR711. The AutoRama with Radio. Instruction Manual

Lanen True Diversity UHF Systems For electric and bass guitars: GB21 For Series 21 mics: UHF21. User Manual GB21 receiver/uhf21 transmitter

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

User Guide. Wideband 4-channel Auto Gain-Control Antenna Divider

ENGLISH MICRO TERROR

MC58 Eight Channel Power Amplifier

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

S-V16P. 16 Channel Video and Power Rack Balun

User Manual. ia480x Power amplifier

OWNER S MANUAL DANGER

DL102 Counter Loop Amplifier

GX POWER AMPLIFIER SERIES. User Manual GX3 300 watts per channel at 8 ohms GX5 500 watts per channel at 8 ohms TD REV.

OWNER S MANUAL EVOLUTION SERIES POWERED SUBWOOFER

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

MAZ 18/MAZ 38. Manual. Model: ZA-8 / ZA-5.

Transcription:

HTA125A/250A Power Amplifiers Installation & Use Manual Specifications subject to change without notice. 2010 Bogen Communications, Inc. All rights reserved. 54-5832-04B 1011

NOTICE: Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. However, information is subject to change. WARNING: To reduce the risk of Fire or Electric Shock, Do Not Expose this apparatus to rain or moisture. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus. WARNING: Only connect unit to AC mains outlet providing protective earthing connection. NOTE: Mains plug is used as disconnect device from the mains and shall remain readily accessible and operable. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. CAUTION: DO NOT INSTALL OR PLACE THIS UNIT IN A BOOKCASE, BUILT-IN CABINET, OR IN ANOTHER CONFINED SPACE. ENSURE THE UNIT IS WELL VENTILATED. TO PREVENT THE RISK OF SHOCK OR FIRE HAZARD DUE TO OVERHEATING, ENSURE THAT CURTAINS AND ANY OTHER MATERIALS DO NOT OBSTRUCT THE VENTILATION VENTS. Always follow these basic safety precautions when installing and using the unit: IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean unit with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Unplug this apparatus during lightning storms or when not used for long periods of time. 13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE ANY FRONT/BACK COVERS OR PANELS. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions.

Panel Diagrams FRONT PANEL HTA125A/250A 1 2 1. Overload Shut Down Indicator 2. ON/OFF Power Switch REAR PANELS HTA125A 4 6 3 1 2 5 7 1. Power Cord: Ground Pin Connected to Chassis 2. 120V AC Outlet (Not Switched) 3. AC Line Fuses 4. Output Connections 5. Balanced Input (Accessory Transformer Required) 6. Unbalanced Input 7. Input Level Adjustment HTA250A 2 3 7 5 1 4 6

Description The Bogen HTA125A and HTA250A Series Power Amplifiers are high performance units. MOSFET technology delivers distortion-free power into reactive loads, such as high-performance loudspeakers or transformers. The HTA125A supplies 125 watts (HTA250A supplies 250 watts) continuous RMS output at less than 0.5% total harmonic distortion, with a frequency response of ±1 db from 20 Hz to 20 khz. An input signal of only 500mV is required for full rated output (150mV for low-impedance balanced input with Model TL600 accessory transformer). Input impedances are high-impedance unbalanced and low-impedance balanced (with TL600 accessory transformer). Outputs include 4-ohm, 8-ohm, 25V (combined with 4-ohm output in HTA125A), 25VCT, and 70V. Line-bridging may be achieved with Bogenʼs TL100 accessory (transformer). The amplifiers are thermally protected to prevent damage due to excessive temperatures. The unique self-protecting output stage prevents thermal runaway which is often encountered in conventional amplifiers. Electric shutdown circuitry is activated if an overload or short occurs and a front panel OVERLOAD SHUTDOWN LED illuminates. Once the cause has been rectified, the unit automatically resets. The power ON/OFF switch, located on the front panel, illuminates when power is ON. The rear panel contains an Input Level control, Input and Output connections, AC Line Fuse, and an Auxiliary Receptacle. A Low-Cut Filter switch is located internally on the printed circuit board. Installation Rack Mounted Installation The amplifier is designed for installation in a standard 19 equipment rack. Position the unit in the rack and secure with screws through the amplifier front panel. NOTE: Before placing the amplifier in a rack, install any accessory transformers required. Ventilation The amplifier generates heat during operation. It must be properly ventilated to prevent excessive temperature rise. If other heatproducing equipment, or several amplifiers have been installed in an enclosed rack or cabinet, you must ensure that there is space above and below the amplifier(s) to allow for passive cooling. It is recommended that the amplifier be installed on the bottom of a rack or above any equipment that does not produce heat. Power and Grounding The AC line cord has a 3-prong plug which should be plugged into a 3-wire grounded, 120V AC, and 60 Hz outlet. It is important to ground the amplifier. Auxiliary Power Receptable Caution: The front panel ON/OFF switch does not control the auxiliary receptacle. The auxiliary power receptacle on the rear panel is a 3-wire grounded outlet and may be used to supply power to accessory equipment in the sound system. Ensure that the accessory equipment does not require more than 300 watts. Equipment connected to the auxiliary receptacle with a 3-prong line cord will be grounded, providing the amplifier line cord has been properly grounded.

Input Connections High-Impedance Input A high-impedance input is provided by two RCA type jacks. An input signal of 500mV is required for full rated output. Low-Impedance Balanced Input Caution: To avoid electric shock, be sure to disconnect AC Power Cord before removing the cover of the amplifier unit. DO NOT perform any function requiring the removal of the cover of the amplifier unless you are qualified to do so. A balanced input, provided at the BAL LO-Z terminal strip, requires the installation of a TL600 line-matching transformer. Remove the top cover of the unit and install the transformer in the socket designated T1 provided on the printed circuit board. An input signal of 150mV is required for full rated output. Bridging Input Caution: To avoid electric shock, be sure to disconnect AC Power Cord before removing the cover of the amplifier unit. DO NOT perform any function requiring the removal of the cover of the amplifier unless you are qualified to do so. The inputs of two or more amplifiers may be paralleled without loss of gain. To do this, install a TL100 transformer (for up to 6 amplifiers) in the transformer socket designated T1 on the printed circuit board. Connect the signal source to the BAL LO-Z terminal strip on the rear panel. Use the two outside terminals on the input terminal strip and connect the cable shield to the GND terminal. If an unbalanced input is required, connect a jumper wire from the GND terminal to an adjacent input terminal. Input from Another Amplifier The HTA125A/HTA250A amplifiers may be driven from an amplifier that provides a 25V or 70V speaker output. Connect the output of the driver amplifier to the HI-Z INPUT jacks via a resistor network. The resistors shown in Fig. 1 are in addition to the normal loudspeaker load on the output of the driver amplifier. OUTPUT TERMINAL STRIP OF DRIVER AMPLIFIER 70V GND R1 R2 100 1/2W AT 70V R1 = 10K, 1/2W AT 25V R1 = 3.3K, 1/2W Fig. 1- Input From Another Amplifier TO HIGH IMPEDANCE INPUT OF POWER AMPLIFIER Output Connections Caution: Follow local electrical codes when connecting amplifier output. Output connections are available on the rear panel terminal strip for 4-ohm, 8-ohm, 25V, 25VCT, and 70V (the 4-ohm output is combined with the 25V tap on the HTA125A). Class 2 wiring is acceptable for output loads. Speaker Matching & Power Distribution The HTA125A and HTA250A feature output connectors for 4-ohm, 8-ohm, 25V, 25VCT and 70V speakers. The amplifiers provide outputs for 25V and 70V speakers. 70-volt speaker connections are made between the 70V and COM terminals on the output terminal strip. The COM and GND terminals of the output terminal strip are connected using a shorting clip. The shorting clip enables the amplifier output to act as an unbalanced output (one side of the output connected to ground). If desired, the output can be made to be a balanced output with no connection to ground. To balance the output, simply remove the shorting clip. All speaker connections remain the same as above. 25V speaker connections are done in the same manner. Hum If the connections between the signal sources and amplifier are incorrect or defective, hum-type interference may occur. Check for proper grounding, broken wires, shields, poor connections, etc. Keep input cables away from speaker cables and away from transformers and AC power lines.

Operation Power The power switch applies power to the amplifier; it does not control any associated equipment which may be connected to the auxiliary power receptacle on the rear panel. The POWER SWITCH illuminates when power has been applied to the unit. Low-Cut Filter Switch Caution: To avoid electric shock, be sure to disconnect AC Power Cord before removing the cover of the amplifier unit. DO NOT perform any function requiring the removal of the cover of the amplifier unless you are qualified to do so. The Low-Cut Filter Switch designated SW1 is located next to the transformer socket on the printed circuit board and is accessible by removing the top cover of the amplifier. The switch provides 10 db attenuation at 100 Hz. Input Level Control The input level control, located on the rear panel, adjusts the input signal applied to the amplifier. Turn the adjustable screw clockwise to increase the level. Overload Shutdown Indicator Electronic shutdown circuitry activates whenever an overload or short occurs on the output of the amplifier. The front panel OVER- LOAD SHUTDOWN LED illuminates indicating the discontinuation of power output; once the cause has been determined and rectified, the unit automatically resets. Thermal Cut-Out The amplifier is protected by a thermal cut-out which should not trip under normal conditions. If it trips, check for inadequate ventilation of the unit or overloading. The cut-out will automatically reset after cooling. AC Line Fuse Replace the fuse only with same type rating. If a second fuse blows, do not make any attempt to operate the unit. Consult the Bogen Service Department or an authorized service agency. Warning: Many loudspeakers may be damaged if overdriven. Therefore, always begin system setup with the input level control fully counterclockwise and gradually increase the setting to obtain the desired output level.

Technical Specifications Rated Output Power: Total Harmonic Distortion: Frequency Response: Input Sensitivity: Hum and Noise: Outputs: Output Regulation: Input Impedances: Low-Cut Filter: Controls & Indicators: HTA125A: 125W; HTA250A: 250W Less than 0.5%, 20 to 20,000 Hz at full rated output ±1 db, 20 to 20,000 Hz at full rated output Hi-Z, 500mV; Lo-Z balanced, with optional transformer, 150mV 90 db below rated output 4 ohms, 8 ohms, 25V, 25VCT, 70V Better than 2 db from no load to full load Hi-Z, 50k ohms unbalanced; Lo-Z, 600 ohms, balanced or unbalanced, and 1:1 bridging with optional plug-in transformers -10 db @ 100 Hz Front Panel Illuminated On/Off power switch and overload shutdown LED Rear Panel Input level control, Slo-Blo fuse Internal Low-Cut filter switch Power Requirements: HTA125A: 120V ~, 60 Hz, 3.1A, 260 watts @ Full Rated Output (Idle 45W) HTA250A: 120V ~, 60 Hz, 5.5A, 520 watts @ Full Rated Output (Idle 60W) Thermal Emissions (full power): HTA125A: 426.9 BTU/hr.; HTA250A: 939.2 BTU/hr Overload Protection: Electronic overload protection Electrical: HTA125A: 4A Slo-Blo Fuse; HTA250A: 7A Slo-Blo Fuse Thermal: Thermostat Auxiliary Receptacle (not switched): Three-wire grounded*, 300 watts maximum Dimensions (without removable feet): 19" W x 5-1/4" H x 11" D (48.3 x 13.3 x 27.9 cm) Front Panel Dimensions: 19" W x 5-1/4" H (48.3 x 13.3 cm) Finish: Black Shipping Weight: HTA125A: 44 lbs.; HTA250A: 56 lbs. Regulatory Approvals: ETL listed Accessories: Model TL600, 600-ohm line-matching transformer; Model TL100, 1:1 line-matching transformer *This receptacle will be grounded only if the power amplifier has been grounded properly.

Limited Warranty; Exclusion of Certain Damages The Bogen HTA125A & HTA250A Power Amplifiers are warranted to be free from defects in material and workmanship for two (2) years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and use, becomes defective (as confirmed by Bogen upon inspection) during the applicable warranty period, will be repaired or replaced by Bogen, at Bogenʼs option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. Repaired or replacement product will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced. THE FOREGOING LIMITED WARRANTY IS BOGENʼS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERʼS SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen's liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. Products that are out of warranty will also be repaired by the Bogen Factory Service Department same address as above or call 201-934-8500. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to parts and labor charges will be at the owner's expense. All returns require a Return Authorization number. For most efficient warranty or repair service, please include a description of the failure. 12/2008 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500 Fax: 201-934-9832 www.bogen.com