HEPA Filter Banks PRECIS ENGINEERING, INC. - SHOP DRAWING REVIEW STAMP APPROVED REVIEWED AS NOTED REJECTED REVISE AND RESUBMIT

Similar documents
Submittal Transmittal

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Echotel Model 910 Ultrasonic Level Switch

SUBMITTAL REVIEW B Passenger Elevators Shop Drawings GCAN

SECTION PANELBOARDS

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

Spec Section: Concrete Mix Design psi - Review Form Concrete Mix Design psi Data Sheets GCAN

Non-Submersible Industrial Pressure Transducer

Level Lance Model 5100

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

SECTION SUBMITTALS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Echotel Model 910 Ultrasonic Level Switch

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

ED701 General Industry Pressure Transmitter

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

UNIFIED FACILITIES GUIDE SPECIFICATIONS

City Plaza Energy Upgrades Timeline of Events Pella Window Cancellation

SUBMITTAL REVIEW Steel Reinforcement - Slab and Masonry Shop Drawings GCAN. Notes: 1. See comments on submittal.

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Spring Return DuraDrive Proportional Actuator

SUBMITTAL LETTER Capital Renewal Scoates Hall, Texas A &M University, College Station, TX TAMUS Project

SUBMITTAL REVIEW Food Service Equipment Data Sheets GCAN. Notes: 1. See D-C Design comments. Submittal: No. 035.

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

SECTION SUBMITTAL PROCEDURES

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

SUBMITTAL REVIEW Underground Natural Gas Piping Data Sheets GCAN. Notes: 1. See engineer s comments. Submittal: No. 016.

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

SECTION SUBMITTALS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

IP26 Series Current to Pneumatic Converter

SECTION GPS WIRELESS CLOCK SYSTEMS

Technical Instructions Document No EA GQD June 23, OpenAir

Taylor County July 2011 SECTION SHOP DRAWINGS, WORKING DRAWINGS AND SAMPLES

St. Monica Food Pantry

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

Sarasota CM200 Sarasota HME900 Density Converter Electronics

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

5 yr. Station Level Paging Adapter. Model 300PBX-SC LINKS TELEPHONE TO SELECTONE OR PUBLIC ADDRESS SYSTEM. dedicated extension

UNION COUNTY VOCATIONAL-TECHNICAL SCHOOLS West Hall Addition Project Raritan Road, Scotch Plains, NJ

SECTION CONTRACTOR SUBMITTALS. A. All submittals by the CONTRACTOR shall be submitted to the ENGINEER.

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

A. This section specifies procedural requirements for Shop Drawings, product data, samples, and other miscellaneous Work-related submittals.

Three models available: Relay output with 24 VDC power input Relay output with 85 to 250 VAC power input Solid-state output with 24 VDC power input

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PRESSURE GAUGES, Section 15130

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

VELTRON II Microprocessor Based Pressure & Flow Smart

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

SECTION SUBMITTAL PROCEDURES

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

PowerFlex 400 AC Drive Guide Specification

UCCS University Hall Fire Sprinkler System Upgrade March 1, 2011 RTA SECTION SUBMITTAL PROCEDURES PART 1 - GENERAL

LA-5000 SERIES LINEAR VALVE ACTUATORS

Specification DataFile

DP2000 ORDERING GUIDE To Order MODEL NO.

Submittal Transmittal

INTREPID Model 336 Digital Microwave Link

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Section Meetings Section Material and Equipment. None Required

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

A. Action Submittals: Written and graphic information that requires Engineer's responsive action.

FEATURES OPTIONAL FEATURES

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

SECTION EQUIPMENT WIRING

DIVISION 1 GENERAL REQUIREMENTS SECTION SUBMITTAL PROCEDURES

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

SECTION SUBMITTAL PROCEDURES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

East Central College

SECTION ELECTRICAL IDENTIFICATION

Submittal Packages Detailed with Items and Reviewers

+GF+ SIGNET Temperature Transmitter Instructions

Echotel Trident 91S/92S Ultrasonic Level Switches

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

Regal Series Recessed Flatwalls

Model 7000 Low Noise Differential Preamplifier

ADDENDUM NO. 2 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

SECTION WOOD DOORS

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MODEL AT-10 ANALOG TRANSMITTER

Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Innovation Wireless KRONOsync GPS or NTP Wireless Clock System

spy pig Tracking systems

RCM DIRECT READING FLOWMETER

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

VARIABLE FREQUENCY DRIVE SPECIFICATION

CONTENTS XV300K GB r doc XV300K 2/13

Echotel Model 911/921 Ultrasonic Level Switches

Load Cell Accessories and Services

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Transcription:

Submittal Review Date: 1/23/15 Project: Teva VA Glatt 14082 Submittal Name: HEPA Filter Banks PRECIS ENGINEERING, INC. - SHOP DRAWING REVIEW STAMP APPROVED REVIEWED AS NOTED REJECTED REVISE AND RESUBMIT REJECTED REVIEW OF THIS SHOP DRAWING IS NOT REQUIRED BY THE CONTRACT DOCUMENTS REJECTED CONTRACTOR SHALL CHECK AND APPROVE PRIOR TO RE-SUBMISSION TO ENGINEER APPROVAL IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR DIMENSIONS TO BE CONFIRMED AND CORRELATED AT THE JOBSITE; INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESS OR TO THE MEANS AND METHODS OF CONSTRUCTION; COORDINATION OF THE WORK OF ALL TRADES; AND PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. THIS APPROVAL DOES NOT MODIFY CONTRACTOR S DUTY TO COMPLY WITH THE CONTRACT DOCUMENTS. REVIEWER: J. GRESKOFF DATE: 01-23-2015 Notes: 1. Filter Banks are approved for size, capacity, and materials of construction. 2. Contractor shall coordinate filter bank flow direction and access door location with routing of exhaust ductwork. Sheet metal contractor shall verify proposed filter bank location maintains filter access clearance prior to ordering filter banks.

TO: BLAIR CONSTRUCTION, INC. LETTER OF TRANSMITTAL P. O. BOX 612 RT. 29 SOUTH DATE: 1/12/2015 JOB NO.: 2948 GRETNA, VIRGINIA 24557 ATTENTION: Dan Kesler 434-656-6243 RE: TEVA Pharmaceuticals USA FAX 434-656-8900 TEVA Pharmaceuticals USA 2150 Perrowville Road Forest, VA 24551 GLATT Relocation and Upgrades Forest, VA Facility WE ARE SENDING YOU: SENT VIA: Submittals Plans Specifications Hand Delivery Overnight Copy of letter Prints Samples First Class Mail UPS Ground Change Order Shop Drawings Electronically COPIES DATE NO. DESCRIPTION 1 pdf 1/12/2015 15600-10.02 Filter Banks THESE ARE TRANSMITTED AS CHECKED BELOW: For approval Reviewed as submitted Resubmit copies for approval For your use Reviewed as noted Submit copies for distribution As requested Returned for corrections Return corrected prints For review and comment FOR BIDS DUE PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO File If enclosures are not as noted, kindly notify us at once. SIGNED Jason A. Richardson, Project Manager

Powered by TCPDF (www.tcpdf.org) Project: SAI Job Number: Submittal Date: Spec Section # & Title: Submittal Description: Manufacturer: Salesman: Vendor: Submittal Identification Submittal Number 114342-4 Teva Pharmaceuticals Glatt CPCG120 Fluild Bed Installation & Facility Upgrades 114342 January 07, 2015 Filter Banks Product Data Flanders Mike Ohare Southeastern Engineering Sales 1001 Port Walthall Drive Colonial Heights, VA 23834 Phone: 804-526-2984 Fax: 804-526-8370 Project Contact: Contractor / Owner: Teva Pharmaceuticals 2150 Perrowville Road Forest, VA 24551 Phone: Fax: Engineer: Project Manager: Subcontractor: Precis Engineering Inc 20 S Maple Street Suite 200 Ambler, PA 19002 Phone: 215-540-9800 Fax: 215-540-9818 Jeff Lambert Southern Air, Inc. 2655 Lakeside Drive Lynchburg, VA 24501 Phone: 434-385-6200 Fax: 434-385-9081 SOUTHERN AIR REVIEW: The equipment and material shown and marked in this submittal is that proposed to be incorporated into this Project, is in compliance with the Contract Drawings and Specifications, unless otherwise shown in bold face type or lettering and listed on a page or pages headed "DEPARTURES FROM DRAWINGS AND SPECIFICATIONS", (if applicable) and can be installed in the allocated spaces. Jeff Lambert January 07, 2015 Reviewed by: Date:

PRESSURE Series A3000 Photohelic Pressure Switch/Gages 3-in-1 Indicating Gage, Lo-Limit and Hi-Limit Control 1/8 FEMALE NPT HIGH PRESSURE CONNECTION 1/8 FEMALE NPT LOW PRESSURE CONNECTION 2-1/2 [63.50] 2-1/16 [52.39] 2 [50.80] 1-1/4 [31.75] (4) 6-32 HOLES EQUALLY SPACED ON A 5-1/8 [130.18] B.C. Differential Pressure Gages/Switches, Dial Set points are instantly adjusted with front knobs. Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT CONNECTION 4-3/8 [111.13] HOUSING REMOVAL 3-7/8 [98.43] 5-1/8 [130.18] 6-3/8 [161.93] (7-5/8 [193.68]) Ø4-47/64 [120.25] Ø5 [127.00] 5/8 [15.88] 5/8 [15.88] PANEL MAX 3/16 [4.76] Ø4 [101.60] FACE 5-1/2 [139.70] O.D. MOUNTING RING Photohelic Switch/Gages function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magnehelic gage design. The Photohelic gage measures and controls positive, negative or differential pressures of air and compatible gases. Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust setpoint indicators are controlled by knobs located on the gage face. Individual setpoint deadband is one pointer width less than 1% of full-scale. Setpoints can be interlocked to provide variable deadband ideal for control of fans, dampers, etc. Gage reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25 in (0-6 mm) w.c. up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar). Photohelic Sensing - How It Works In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Deadband between make and break is 1% of full scale or less just enough to assure positive, chatter-free operation. Relay - Transformer Features A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards. APPLICATIONS - PHOTOHELIC SWITCH/GAGES In both series of pressure switch/gages, you get the convenience of a visual indication plus high-low limit switching. For both OEM and in-plant applications, the Photohelic switch/gage is used to control pressures in air conditioning systems, clean rooms, fluidic and pneumatic control systems, materials handling equipment, alarm or control fume exhaust systems, control pressure in air structures, and monitor respiratory and blood pressures. Standard Two phototransistor-actuated circuits and two DPDT relays permit both high and low alarms or limit controls. Relays are de-energized when gage pointer is to the left of respective set points; relays are energized as pointer passes to the right of set points. Loss of electrical power or loss of pressure provide fail safe protection. High and Low Latching Circuits Dwyer Photohelic switch/gages can be wired for high-latching, low-latching, or combination high-low latching circuits. That is, the equipment will hold in these respective positions once activated and until manually reset. This can be particularly useful for alarm and signal applications where control is accomplished by another Photohelic switch/gage or other means. Complete wiring and operational instructions are included. Where manual reset is required a dry circuit push button such as Dwyer Part A-601 should be used. SPECIFICATIONS GAGE SPECIFICATIONS Service: Air and non-combustible, compatible gases. Wetted Materials: Consult factory. Accuracy: ±2% of FS at 70 F (21.1 C). ±3% on -0 and ±4% on -00 models. Pressure Limits: -20 Hg to 25 psig (-0.677 to 1.72 bar); MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar); A36003S 36010S: 150 psig (10.34 bar); A36020S and higher: 1.2 x full-scale pressure. Temperature Limits: 20 to 120 F (-6.67 to 48.9 C). Low temperature option available. Process Connections: 1/8 female NPT. Size: 4 (101.6 mm) dial face, 5 (127 mm) OD x 8-1/4 (209.55 mm). Weight: 4 lb (1.81 kg). SWITCH SPECIFICATIONS Switch Type: Each setpoint has 2 form C relays (DPDT). Repeatability: ±1% of FS. Electrical Rating: 10A @ 28 VDC, 10A @ 120, 240 VAC. Electrical Connections: Screw terminals. Use 167 F (75 C) copper conductors only. Power Requirements: 120 VAC, 50/60 Hz; 240 VAC & 24 VAC power optional. Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations. Set Point Adjustment: Adjustable knobs on face. Agency Approvals: CE, CSA, UL. Optional-EXPL explosion-proof enclosure does not possess any agency approvals. OPTIONS Single contact, right set point, for actuation on increasing or decreasing pressure. OEM, less relay and transformer components and housing but including infrared diodes and phototransistor(s), light shutter and set pointer(s). For single or double contact. Remote-Mounted Relay, relay pack may be mounted remotely from gage. Standard length is 5 ft. For other lengths, specify cable length required. Tamper-proof knobs, low temperature option, special scales, voltages and other features and modifications are available. Special Housings available include Weatherproof (NEMA 4) and Explosion-proof (NEMA 7 C, D, 9 E, F, G; NEC Class I, DIV. 1 & 2, Groups C, D, Class II, Div. 1 & 2, Groups E, F, G, Class III.) Contact Customer Service for detailed dimension drawings. -NIST, NIST traceable calibration certificate 22 DWYER INSTRUMENTS, INC. www.dwyer-inst.com

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic gage set point mechanism. Cover is clear polycarbonate plastic. Check these features for dependable control Plastic enclosure protects electronic components and electrical connections. Polycarbonate connection or terminal board is self-extinguishing. PRESSURE Gage pointer and light shutter are mounted on helix and balancing counterweight. Shutter passes through slot in optical limit switch to expose phototransistors to integral infrared light source or mask them depending on applied pressure. Light shield effectively protects phototransistors from strong outside light sources yet allows free pointer movement. It also gives interior a clean finished look. Optical limit switches are used for reliability and long service life. Attached directly to set pointers, they are individually aligned to assure precise switching accuracy. Glass-epoxy printed circuit boards for durability and performance. Load relays are DPDT with latching feature for maximum application versatility. Electronics are designed to operate on 50/60 Hz, 120 volt current with 10% over or under voltage. Special units for other voltages are available. Switch set pointers show switch settings at all times. Spring loaded friction clutch prevents operator damage of set point mechanism. Differential Pressure Gages/Switches, Dial Semi-Flexible drive shaft connects to set point knobs. Zero adjustment screw connects to screw in cover to adjust zero pressure reading. s and Ranges - Series A3000 Photohelic Switch/Gages Note: Special models can be built to OEM customers' specifications with scales reading in special pressure units like ounces per square inch, inches of mercury, etc. Square Root Scales reading in FPM or SCFM are also available. Custom logos and special graduations can also be included. Contact factory for minimum quantities and pricing. in w.c. A3000-00 0-.25 A3000-0 0-.50 A3001 0-1.0 A3002 0-2.0 A3003 0-3.0 A3004 0-4.0 A3005 0-5.0 A3006 0-6.0 A3008 0-8.0 A3010 0-10 A3015 0-15 A3020 0-20 A3025 0-25 A3030 0-30 A3040 0-40 A3050 0-50 A3060 0-60 A3080 0-80 A3100 0-100 A3150 0-150 Bi-Directional Range A3000-00N.05-.20 A3300-0 A3301 A3302 A3304 A3310 A3320 A3330 A3000-00AV A3000-0AV A3001AV A3002AV A3010AV in w.c..25-0-.25.5-0-.5 1-0-1 2-0-2 5-0-5 10-0-10 15-0-15 Range in w.c. /Air Velocity, FPM 0-.25/300-2000 0-.50/500-2800 0-1.0/500-4000 0-2.0/1000-5600 0-10/2000-12500 Pitot tube required mm w.c. A3000-6MM 0-6 A3000-10MM 0-10 A3000-25MM 0-25 A3000-50MM 0-50 A3000-80MM 0-80 A3000-100MM 0-100 A3300-20MM A3300-30MM A3000-60PA A3000-125PA A3000-250PA A3000-500PA A3000-750PA 10-0-10 15-0-15 Pascals 0-60 0-125 0-250 0-500 0-750 A3300-250PA A3300-500PA A3000-1KPA A3000-1.5KPA A3000-2KPA A3000-3KPA A3000-4KPA A3000-5KPA A3000-8KPA A3000-10KPA A3000-15KPA A3000-20KPA A3000-25KPA A3000-30KPA Pa 125-0-125 250-0-250 kpa 0-1 0-1.5 0-2 0-3 0-4 0-5 0-8 0-10 0-15 0-20 0-25 0-30 A3300-1KPA.5-0-.5 A3300-3KPA 1.5-0-1.5 OPTIONS & ACCESSORIES - Add options as a suffix. Example: A3001-LT -SRH, Single Relay Activates on Increase -SRL, Single Relay Activates on Decrease -OLS, OEM model -RMR, Remote mounted relay -TAMP, Tamper proof knobs -MP, Medium pressure -HP, High pressure -LT, Low temperature (-20 F) A-298, Flat Flush Mounting Bracket A-601, Manual reset switch net Process Tubing Options: See page 547 (Gage Tubing Accessories) CONTACT US U.S. 219/879-8000 U.K. (+44) (0)1494-461707 A.U. (+61) (0) 2 4272 2055 China +852-23181007 23