CABLES AND WIRES

Similar documents
Low Voltage Cable Range. Edition 4 Brochure

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

ABOUT US ABOUT US 1 CRANE CABLES

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

P Low Voltage Catalogue Cables Australia Powering your Project

Medium Voltage Power Cables

Notes 3 Explanatory Information 4-10

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Chapter 6. WIRING SYSTEMS Safe Electrical Design

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

Power Cables and their Application

Armoured Power and Control Cables to BS7917

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Armoured Power and Control Cables Fire Resistant

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

Technical Specification. for 1.1 KV Copper Control Cable

SUBMERSIBLE PUMP CABLES

Electric cables. Cranes

Armoured Power and Control Cables to BS6883

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

Welding Cables Rubber Insulated

FLEXIBLE MULTI CORE CABLES

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Selection table for flat & ribbon cables

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

kv: medium voltage reeling cable with fibreoptics

High Temperature Flexible Control Cable

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

H07RN-F BS EN Flexible Rubber Cable

Flexitime! Our flexible cables save you time and money.

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CIR (Crush & Impact Resistant) VFD Power Cable

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Fault location on power cables. Fault location on power cables

Product information. Marine, Oil & Gas.

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

Kerman & Kavian Cable Industries ( KCI )

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

Marine Cables General Catalogue

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

High Temperature Flexible Control Cable OLFLEX

XLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

MEDIUM VOLTAGE

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Armoured Instrumentation Cables to BS6883

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

TRAXLINE CABLES FOR MOTION

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Installation Recommendations

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

Tri-Rated Flexible PVC Equipment Wire

Spec wire. Performance Wire and Cable

TIGER BRAND MINING CABLES

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

THE WORLD OF LAPP. Cables for power chains

DLO Flexible Power Cable

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

EDS LV WAVEFORM MAINS CABLE RATINGS

To keep your family safe and protected V-Guard Wires & Cables

Airport Cables & Connectors

14 AWG 2 AWG: 600 Volt

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Medium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

T E C H N I C A L D A T A for

Wire and Cable. 55 Wire Single or Dual Wall 200ºC rated, XLETFE High performance wire and cable. Features & Benefits

REPORT OF PERFORMANCE TIC

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

Paramount Communications Ltd., part of the Paramount Cables Group. started up as a small- scale cable unit more than 60 years ago and

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

EDS KV TRIPLEX CABLE RATING

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

List Price w.e.f. 02nd January, 2018

Railway products. Edition 2014

Information technology. Generic cabling systems, General requirements

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

Transcription:

CABLES AND WIRES VOLTEX CATALOGUE 41 3

PVC GENERAL PURPOSE WIRE 1kV House Wire 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with PVC and skin coloured in plain colours to SANS 1411 Part 2. Cable is manufactured to SANS 1507 Part 3. Installation Information For the wiring of Industrial Buildings, Housing, Control Panels and Light Fittings. Technical Data Properties Specifications : SANS 1507-3 Temperature Range : -10 C to 70 C Voltage Rating : 600/1000V Core Identification : Complete range of colours Packaging : 100m shrink-wrapped /500m reels Nominal Stranding No. x Diameter Cable Diameter Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/100m) 600/1000 V 1 7/0,42 3,0 17 18,1 43 1,7 1,5 7/0,53 3,3 21 12,1 29 2,2 2,5 7/0,66 3,6 27 7,41 18 3,2 4 7/0,86 4,5 36 4,61 11 5,2 6 7/1,04 5,0 45 3,08 7,4 7,0 10 7/1,35 6,0 61 1,83 4,4 11,1 16 7/1,67 6,9 78 1,15 2,8 16,7 25 19/1,38 8,4 104 0,73 1,7 25,6 35 19/1,62 9,5 125 0,52 1,3 34,7 50 19/1,88 11,3 149 0,39 0,93 47,2 70 19/2,28 12,6 190 0,27 0,65 66,1 95 19/2,50 15,8 238 0,19 0,48 97,6 120 37/2,03 17,5 272 0,15 0,38 120,0 150 37/2,28 19,7 308 0,12 0,32 147,0 185 37/2,50 22,0 350 0,10 0,26 182,2 Rating calculated for 1kV cable. Rating based on two touching cables installed in a duct. Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Compacted Conductors. Code Table Colours (mm 2 ) Black Blue Brown Green Yellow Grey Mustard Orange Pink Purple Red White Yellow 1 F232 F233 F234 F235 F236 - F237 F238 F239 F240 F241 F242 1,5 F245 F246 F247 F249 F250 F251 F252 F253 F254 F256 F258 F259 2,5 F262 F263 F264 F266 F267 - F268 F269 F270 F272 F274 F275 4 F278 F279 F280 F282 - - F283 F284 F285 F287 F289 F290 6 F293 F294 - F296 - - - - - F298 F300-10 F303 F304 - F306 - - - - - F308 F310-16 F313 F314 - F316 - F2789 - - - F318 F320 F321 25 F323 F324 - F326 - - - - - F327 F328-35 F330 F331 - F333 - - - - - F335 F337-50 F340 F341 - F343 - - - - - F344 F346-70 F349 F350 - F352 - - - - - F354 F355-95 F356 F1315 - F358 - - - - - F359 F1316-120 F360 - - F361 - - - - - F1317 - - 150 - - - F362 - - - - - F363 - - 185 F364 - - F365 - - - - - - - - For items marked with a dash (-) please enquire at branch or reference website. 42 2 VOLTEX CATALOGUE

SURFIX CABLE 300/500V Cable Description Copper conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare tinned copper earth wire in contact with a longitudinal aluminium/polyethylene laminate, UV stable PVC sheathed to SANS 1411 Part 2. Installation Information Complies with SANS 10142 Code of Practice for wiring of Premises Section 6: Surface wiring Under plaster wiring Wiring in hollow walls Wiring in roof spaces The cable shall not be buried direct in concrete or in screed. Joints in the wiring should be in boxes only. Technical Data Properties UV Stable Specifications : SANS 1507-2 Temperature Range : -10 C to 70 C Voltage Rating : 300/500V Sheath Identification : White or Black Core Identification : 2 Core - Red & Black, 3 Core - Red, Yellow, Blue, 4 Core - Red, Yellow, Blue, Black Packaging : 100m shrink-wrapped coils : Available on 500 and 1000m wooden drums on request (depending on size) Phase Earth Phase Earth Electrical Properties Conductor Resistance (dc at 20ºC) Current Rating Volt Drop 1 Sec Short Circuit Rating Overall Diameter Physical Properties Cable Mass (mm 2 ) (Ω/km) (A) (mv/a/m) (ka) (mm) (kg/100m) 2 Core 1,5 1 12,1 18,2 17 29 0,14 7,8 10,6 2,5 1,5 7,41 12,2 23 18 0,24 8,8 14,4 4 1,5 4,61 12,2 30 11 0,38 10,1 20,8 6 2,5 3,08 7,56 38 7,3 0,58 11,3 25,7 3 Core 1,5 1 12,1 18,2 15 25 0,14 8,0 10,9 2,5 1,5 7,41 12,2 20 15 0,24 9,3 15,7 4 1,5 4,61 12,2 27 9,5 0,38 10,8 21,0 6 2,5 3,08 7,56 34 6,4 0,58 12,0 28,7 4 Core 1,5 1 12,1 18,2 15 25 0,14 8,7 13,3 2,5 1,5 7,41 12,2 20 15 0,24 10,2 19,3 4 1,5 4,61 12,2 27 9,5 0,38 11,8 26,5 6 2,5 3,08 7,56 34 6,4 0,58 12,8 33,5 Conductors larger than 2,5mm² are usually stranded. Maximum conductor temperature 70 C, and installed as per installation Method 3 of SANS 10142-1. 2 Core - Volt drop is phase to Neutral (i.e. Single-phase). 3 and 4 Core - Volt drop is phase-to-phase. (i.e. Three phase AC). Code Table Black Surfix is a trademark of Aberdare Cables, a member of the Powertech Group. Other colours available on request. Minimum quantities apply. Colours (mm 2 ) 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 1,5 F598 F603 F608 F600 F605 F609 2,5 F614 F619 F623 F616 F620 F624 4 F627 F631 F635 F628 F632 F636 6 F639 F641 F643 F640 F642 F644 10 F610 - - F611 - - For items marked with a dash (-) please enquire at branch or reference website. White VOLTEX CATALOGUE 43 3

FLAT TWIN AND EARTH CABLE 300/500V Cable Description Copper conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare copper earth-continuity-conductor between them, UV stable PVC sheathed to SANS 1411 Part 2. Installation Information Complies with SANS 10142/2001 Code of Practice for the wiring of Premises Section 6, Clause 6.3.6: Surface wiring Under plaster wiring Roof access wiring Wiring in hollow walls Properties Specifications : SANS 1507-2 Temperature Range : -10 C to 70 C Voltage Rating : 300/500V Sheath Identification : White or Black Core Identification : 2 Core - Red & Black, 3 Core - Red, Yellow, Blue Packaging : 100m shrink-wrapped coils The cable should not be buried direct in concrete or in screed. Joints in the wiring should be in boxes only. Technical Data Phase Earth Phase Earth Electrical Properties Conductor Resistance (dc at 20ºC) Current Rating Volt Drop 1 Sec Short Circuit Rating Conductors larger than 2,5mm² are usually stranded. Maximum conductor temperature 70 C, and installed as per installation Method 3 of SANS 10142-1. 2 Core - Volt drop is phase to Neutral (i.e. Single-phase). 3 and 4 Core - Volt drop is phase-to-phase. (i.e. Three phase AC). Overall Diameter Physical Properties Cable Mass (mm 2 ) (Ω/km) (A) (mv/a/m) (ka) (mm) (kg/100m) 2 Core 1,5 1 12,1 18,1 17 29 0,14 8,7 x 4,7 8,7 2,5 1,5 7,4 12,1 23 18 0,24 10,3 x 5,5 12,8 4 1,5 4,61 12,1 30 11 0,38 11,9 x 6,4 17,5 6 2,5 3,08 7,41 38 7,3 0,58 13,4 x 7,0 23,3 10 4 1,83 4,61 52 4,4 0,96 16,5 x 8,3 36,1 3 Core (Trip) 1 1 18,2 18,2 12 38 0,11 4,4 x 10,4 8,9 1,5 1 12,1 18,2 15 25 0,14 4,8 x 10,5 9,9 2,5 1,5 7,4 12,2 20 15 0,24 5,5 x 12,3 14,1 Code Table Black Colours (mm 2 ) 2 Core 3 Core 2 Core 3 Core 1 F663 - F665 F659 1,5 F667 - F669 F660 2,5 F671 - F672 F661 4 F674 - F675-6 - - F676-10 F678 - F679-16 - - F681 - White For items marked with a dash (-) please enquire at branch or reference website. 44 2 VOLTEX CATALOGUE

CABTYRE CABLE Flexible Wiring 300/300V and 300/500V Cable Description High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. Insulated and colour coded with general purpose flexible grade PVC to SANS 1411 Part 2. Cores are twisted together and sheathed with a flexible grade PVC. Installation Information For supplying power to all types of electrical, domestic and industrial appliances and equipment such as: Power Tools Electric Lawnmowers Kitchen Appliances Technical Data Extension Leads Multi Plug Extensions Small Industrial Machinery Properties Specifications : SANS 1574 Temperature Range : -10 C to 70 C Voltage Rating : Light Duty (LD) 300/300V and Normal Duty (ND) 300/500V Sheath Identification : White, Black or Grey Core Identification : 2 Core - Blue & Brown, 3 Core - Blue, Brown & Yellow/Green, 4 Core - Blue, Brown, Black & Yellow/Green, 5 Core - Blue, Black, Brown, Yellow/Green, Violet, 7 Core - Blue, Brown, Black,Yellow/ Green, Violet, Pink, Orange Packaging : 100m shrink-wrapped coils/500m and 1000m lengths available on request Number of Cores Nominal Stranding No. x diameter Overall Diameter Conductor Resistance at 20ºC Maximum Current Volt Drop Rating 1OI 3OI 1OI 3OI Cable Mass (mm 2 ) (mm) (Ω/km) (A) (mv/a/m) (kg/100m) Light Duty 300/300V 0,5 2 5,2 3 5,5 4,7 15/0,2 39 3 3 93 80 4 6,0 5,5 5 6,6 6,7 0,75 3 23/0,2 6,1 26 6 6 62 54 5,5 0,75 1 1,5 2,5 4 2 6,2 Normal Duty 300/500V 3 7,0 6,7 4 23/0,2 7,2 26 6 6 62 54 7,8 5 8,2 9,9 7 8,7 12,6 2 6,6 3 7,0 7,6 4 30/0,2 8,0 19,5 10 10 46 40 9,8 5 8,6 11,6 7 9,3 14,8 2 7,8 3 8,3 10,8 4 44/0,2 9,3 13,3 16 16 32 27 13,5 5 10,0 16,2 7 10,9 20,7 2 9,6 3 10,3 16,8 4 72/0,2 11,9 7,98 25 20 19 16 21,8 5 12,2 24,2 7 13,2 31,3 2 11,0 3 11,4 25,0 112/0,2 4,96 32 25 12 10 4 13,5 32,0 5 14,1 33,9 3,9 5,2 6,3 8,4 13,5 19,0 Current Rating based on ambient temperature of 30ºC. Maximum Conductor temperature is 70 C. Code Table Colours Black Grey White (mm 2 ) 2 Core 3 Core 4 Core 5 Core 7 Core 2 Core 3 Core 4 Core 5 Core 7 Core 2 Core 3 Core 4 Core 5 Core 7 Core 0,5 F83 F87 F91 F93 - - F88 - - - F84 F89 F92 F1519-0,75 F95 F100 F106 F108 F110 F3266 F101 - - - F96 F107 F107 F109-1 F113 F119 F123 F126 F128 F114 F120 F1521 - - F115 F121 F124 F1522 F1523 1,5 F131 F137 F143 F148 F153 - F138 F1525 F149 - F132 F139 F144 F150 F154 2,5 F155 F161 F166 F171 F173 - F162 F167 - - F156 F163 F168 F172 F174 4 F175 F176 F178 F181 F182 - F1530 F179 - - F1529 F177 F180 - - For items marked with a dash (-) please enquire at branch or reference website. VOLTEX CATALOGUE 45 3

AUDIO CORD CABLE (RIPCORD) Flexible Wiring Cable Description High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. 2 Core insulated with general purpose flexible grade PVC to SANS 1411 Part 2. Installation Information For the wiring of all types of: Intercoms Alarm Systems Audio and Visual Equipment Packaging : 100m shrink-wrapped coils Technical Data Nominal Stranding No. x Diameter Cable Diameter Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/100m) 0,2 7/0,2 1,6 x 3,2 1 92 248 0,95 0,4 11/0,2 2,1 x 4,2 2 48,8 98 1,6 0,5 15/0,2 2,5 x 5,0 3 39 93 2,2 0,75 23/0,2 2,7 x 5,4 6 26 62 2,8 1,00 30/0,2 2,9 x 5,8 10 19,5 46 3,6 1,5 44/0,2 3,2 x 6,4 16 13,3 32 4,3 2,5 72/0,2 3,9 x 7,9 25 7,98 19 6,9 4 112/0,2 4,7 x 9,4 32 4,96 12 10,9 Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Code Table Colours (mm 2 ) Black Brown Clear Grey Red Black White 0,2 - F1322 F1321 - - F520 0,5 F524 F525 F526 F1326 F528 F527 0,75 F530 F1327 F531 F1328 - F532 1 F533 F534 F535 - - F536 1,5 F537 - - - F538 F539 2,5 - - - - F540 F1330 4 - - - - F541 - For items marked with a dash (-) please enquire at branch or reference website. 46 2 VOLTEX CATALOGUE

SINGLE CORE FLEXIBLE CABLE Single Core Flexible Cable 300/500V and 600/1000V Cable Description High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. Insulated with general purpose flexible grade PVC in all colours to SANS 1411 Part 2. Installation Information For the wiring of all types of: Control panels Light fittings Communication panels Appliances Technical Data Properties Specifications : SANS 1574-3 Temperature Range : -10 C to 70 C Voltage Rating : 300 / 500V and 600/1000V Core Identification : Blue, Black, Brown, Yellow/Green, Orange, Pink, Violet, Grey, White & Red Packaging : 100m shrink wrapped coils : 500m lengths available on request Nominal Stranding No. x Diameter Cable Diameter Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Rating for 2 wires only. Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/100m) 600/1000V 0,5 15/0,2 2,6 11 39 93,3 1,1 0,75 23/0,2 2,8 14 26 62,2 1,3 1 30/0,2 3,0 16 19,5 46,7 1,6 1,5 44/0,2 3,3 20 13,3 31,8 2,2 2,5 72/0,2 3,7 26 7,98 19,1 3,1 4 112/0,2 4,8 35 4,95 11,8 4,9 6 175/0,2 5,3 43 3,30 7,9 7,3 10 294/0,2 9,1 58 1,91 4,6 11,1 16 462/0,2 10,0 75 1,21 2,9 16,7 25 721/0,21 12,7 100 0,78 1,9 27,1 35 1026/0,21 14,5 122 0,55 1,3 35,8 Code Table Colours (mm 2 ) Black Blue Brown Green Yellow Grey Orange Pink Violet Red White Yellow 0,5 F433 F434 F435 F436 F437 F440 F439 F442 F441 F443 F444 0,75 F445 F446 F447 F448 F449 F451 F450 F453 F452 F454 F455 1 F456 F457 F458 F459 F461 F463 F462 F465 F464 F466 F467 1,5 F468 F469 F470 F471 F472 F474 F473 F476 F475 F477 F478 2,5 F489 F490 F491 F492 F493 F1346 F1343 F1345 F494 F495 F496 4 F497 F498 F499 F500 F501 F1348 - F1347 F502 F503 F3426 6 F504 F505 F506 F507 F508 - - - F509 - F510 10 F479 F480 - F481 - - - - F482 F483-16 F484 F485 - F486 - - - - F487 F488-25 F1350 F1351-1353 - - - - F1349 F1352 - For items marked with a dash (-) please enquire at branch or reference website. VOLTEX CATALOGUE 47 3

POWER PANEL FLEX CABLE 300/500V and 600/1000V Cable Description Single core flexible copper conductors to SANS 1411 Part 1, Insulated with general purpose flexible grade PVC and sheathed with a flexible grade waterproof PVC/Nitrile. Installation Information A flexible power cable where flexibility is needed in equipment such as: LV transformer connections Motor control centres General wiring applications Distribution boards Technical Data Properties Specifications : SANS 1574-3 Temperature Range : -10 C to 70 C Voltage Rating : 300/500 V and 600/1000V Core Identification : Red, Black, Blue, Yellow, Green and Grey Packaging : 100m shrink-wrapped coils : 500m lengths available on request Conductor Size Conductor Diameter Cable Diameter Impedance at 70 C Current ratings are based on cable installed in a cubicle, and may vary depending on other applications. Assumed ambient air temperature is 30 C. Maximum conductor temperature is 70 C. Derating of maximum current for other ambient temperatures - use rating factor X as given below: Ambient temperature, ºC : 25 30 35 40 45 Rating factor, X : 1,04 1,00 0,95 0,91 0,85 Fault rating : 115A/mm² (1 Second) Volt Drop (mv/a/m) Continuous Current Rating (A) Cable Mass (mm 2 ) (mm) (Ω/km) 1OI 3OI 1OI 3OI (kg/100m) 16 5,2 10,8 1 460 2,8 2,4 76 64 23,00 25 7,1 13,5 0,933 1,7 1,5 104 88 31,50 35 8,5 15,3 0,663 1,3 1,1 125 106 42,50 50 10,4 18,4 0,462 0,9 0,8 148 126 57,50 70 11,6 21,2 0,326 0,7 0,6 187 159 76,00 95 14,1 24,1 0,247 0,5 0,4 232 198 101,00 120 15,6 25,6 0,193 0,4 0,4 265 226 129,00 150 17,30 27,7 0,16 0,3 0,3 299 255 159,00 185 20,00 30,8 0,14 0,3 0,3 343 292 189,00 Code Table Colours (mm 2 ) 16 Green F2815 25 Blue F2816 35 Grey F2817 50 Red F2818 70 Brown F2819 95 Yellow F2820 120 Black F2821 150 Black F2822 48 2 VOLTEX CATALOGUE

SILICONE CABTYRE CABLE Flexible Cable 300/500V Cable Description High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone Rubber Type RD7 and sheathed with Silicone Rubber Type RS8 to SANS 1574 Part 4 Type R7, H05SS-F. Installation Information For the wiring of all types of: Stoves Electrical Motors and Pumps Fluorescent Lights All other types of High Temperature Appliances Properties Specification : SANS 1574-4 Pt4 Temperature : -50 C to 150 C (Capable of current rating at 180 C if there are no limits imposed by environmental conditions) Voltage Rating : 300/500V Core Identification : 3 Core - Blue, Brown and Yellow/Green, 4 Core - Blue, Brown, Black and Yellow/Green : Insulation and sheath is halogen free and has a low smoke emission : Limiting Oxygen Index is 24% Packaging : 100m shrink - wrapped coils Technical Data Number of Cores Nominal Stranding No. x diameter Cable Diameter Conductor AC Resistance at 150 C Current Rating Cable Mass (mm 2 ) (kg/km) (mm) (Ω/km) (A) (kg/km) 0,75 3 24/0,2 7,6 40,3 17 72 1 3 32/0,2 9,9 30,2 21 127 1,5 2,5 4 3 10,8 135 30/0,25 20,7 26 4 10,6 160 3 11,6 192 50/0,25 12,4 36 4 11,8 237 3 13,5 283 56/0,3 7,7 56 4 14,8 345 Assumed ambient temperature is 80 C. Maximum Conductor temperature is 150 C. Derating of Current Rating for other Ambient Temperatures. Ambient Temperature, C : 40 60 80 100 120 140 160 Rating Factor, X : 1,22 1,12 1 0,87 0,73 0,57 0,37 Code Table Colour RED (mm 2 ) Core 3 Core 4 0,75 F2261 F1270 1,00 F3342 F9416 1,50 F185 F2265 2,50 F188 F2266 4,00 F1485 - VOLTEX CATALOGUE 49 3

SILICONE SINGLE CORE CABLE Flexible Cable 300/500V and 600/1000V Cable Description High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone Rubber Type RD7 to SABS 1574 Part 4, H05SS-F & HIS-F in various colours. Installation Information For the wiring of all types of: Control Panels Appliances Light Fittings All High Temperature Applications Technical Data Properties Specification : SANS 1574 Pt4 Temperature : -50 C to 150 C (Capable of current rating at 180 C if there are no limits imposed by environmental conditions) Voltage Rating : 300/500V (0,05mm 2-16mm 2 ) and 600/1000V (0,5mm 2-95mm 2 ) Core Identification : Red, Black, Blue, Brown, Green/Yellow and White (Other colours available on request) : Insulation is halogen free and has a low smoke emission. Limiting Oxygen Index is 24% Packaging : Shrink - wrapped - Coils 100m 0,5-35mm 2 - Reels 100m 50 mm 2 Conductor AC Current Rating Nominal Cable Diameter Resistance Single Cable Cable in Trefoil Cable Mass No. x diameter Stranding 300/500V 600/1000V 180 C 180 C 300/500V 600/1000V (mm 2 ) (mm) (Ω/km) (A) (kg/km) 0,5 16/0,2 2,2 2,6 65,3 21 13 8,8 10,7 0,75 24/0,2 2,4 2,8 43,5 26 17 11,7 13,4 1 32/0,2 2,5 3,0 32,6 30 19 14,3 18,1 1,5 30/0,25 3,2 3,3 22,3 37 24 22,4 23,9 2,5 50/0,25 3,9 3,7 13,4 49 31 34,7 37,4 4 56/0,3 4,7 4,8 8,29 65 42 52,4 54,4 6 81/0,3 5,2 5,3 5,52 81 52 71,2 75,2 10 77/0,4 6,6 6,3 3,18 112 72 117,8 118,5 16 125/0,4 7,6 7,2 2,02 143 92 180,7 180,7 25 184/0,4 9,5 1,29 190 124 280 35 267/0,4 10,9 0,92 230 151 391 50 378/0,4 N/A 13,2 0,64 282 186 N/A 551 70 341/0,5 14,4 0,45 352 234 750 95 456/0,5 17,3 0,34 423 285 1010 Capable of continuous current rating at 180 C and 250 C if there are no limits imposed by environmental conditions. Ambient temperature is 80 C. Maximum Conductor temperature is 150 C. Derating of Current Rating for other Ambient Temperatures. Ambient Temperature, C : 40 60 80 100 120 140 160 Rating Factor, X : 1,22 1,12 1 0,87 0,73 0,57 0,37 Code Table Colours Black Blue Brown Green Grey Orange Red Violet White (mm 2 ) 0,5 F1256 F1257 - F1258 - - F1259 - F1260 0,75 F1261 F1262 F1263 F1264 F1265 - F1266 - F1267 1 F2468 F2469 F1460 F1461 F1462 - F2467 - F1463 1,5 F549 F551 F552 F1110 F555 - F557 F1272 F558 2,5 F559 F561 F562 F1112 F565 F1467 F566 F1468 F2474 4 F569 F570 - F916 F1482 - F572 F1483 F573 6 F574 F575 - F1491 F1492 - F576 F1493 F577 10 F578 F1276 - F1277 F1278 - F579 F1279 F1449 16 F1454 F1455 - - F1456 - F1457 - F1458 25 F1474 - - - F1475 - F1476 - - 35 F1478 - - - - - F1479 - - 50 F1487 - - - - - F1488 - - 70 F1535 - - - - - F1536 - - 95 F1556 - - - - - F1557 - - For items marked with a dash (-) please enquire at branch or reference website. 50 2 VOLTEX CATALOGUE

SUBMERSIBLE PUMP CABLE 3 and 4 Core 600/1000V Cable Description High conductivity bunch plain flexible copper conductors to SANS 1411 Part 1. Cores insulated and bedded with Flexible PVC Grade. Final protection is given by a flexible PVC outer sheath. Installation Information Power supply of mobile and portable submersible pumps as used in: Quarries Farms Cleaning and Sewerage extraction plants De-watering Boreholes Properties Specifications : SANS 1574 Temperature Range : -10 C to 70 C Insulation & Sheath : Flexible grade waterproof PVC Voltage Rating : 600/1000V Sheath Identification : 3 Core - Blue, 4 Core - Green Core Identification : 3 Core - Red, Yellow, Blue, 4 Core - Red, Yellow, Blue, Black Packaging : Available on 500m wooden drums Technical Data Minimum Bending Radius Cable Diameter Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop 3OI Cable Mass (mm 2 ) (mm) (mm) (A) (Ω/km) (mv/a/m) (kg/m) 3 Core (Blue) 1,5 x 3 82 10,2 15 13,3 29 25 0,15 2,5 x 3 94 11,7 20 7,98 17 15 0,2 4 x 3 108 13,5 30 4,96 12 9,5 0,3 6 x 3 121 15,1 35 3,30 7,3 6,4 0,5 10 x 3 141 17,6 50 1,91 4,3 3,8 0,6 16 x 3 161 20,1 65 1,21 2,8 2,4 0,8 4 Core (Green) 1,5 x 4 89 11,2 15 13,3 29 25 0,2 2,5 x 4 102 12,8 20 7,98 17 15 0,25 4 x 4 116 14,6 30 4,96 12 9,5 0,35 6 x 4 132 16,5 35 3,30 7,3 6,4 0,5 10 x 4 153 19,2 50 1,91 4,3 3,8 0,7 16 x 4 176 22,0 65 1,21 2,8 2,4 1 Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Code Table Colours Blue Green (mm 2 ) 3 Core 4 Core 1,5 x 3 F1510-1,5 x 4 F1512-2,5 x 3 F584-2,5 x 4 F586 F1509 4 x 3 F588-4 x 4 F590 F1163 6 x 3 F1514-6 x 4 F7922 F1515 10 x 3 F1516-10 x 4 - F3333 16 x 3 F1517 - For items marked with a dash (-) please enquire at branch or reference website. VOLTEX CATALOGUE 51 3

NITRILE TRAILING CABLE Flexible PVC - 4 Core 600/1000V Cable Description High conductivity bunch plain flexible copper conductors to SANS 1411 Part 1. Cores insulated and bedded with Flexible PVC. Flexible Grade PVC / Nitrile outer sheath. Installation Information Power supply of mobile and stationary industrial machinery. Applications that require medium duty abrasion and where oil and water resistance is required. Technical Data Properties Specifications : SANS 1574 Temperature Range : -10 C to 70 C Voltage Rating : 600/1000V Sheath Identification : PVC/Nitrile - Orange Core Identification : Red, Yellow, Blue, Black Packaging : Available on 500m wooden drums Overall Diameter Current Rating Conductor Resistance at 20 C Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/m) 1,5 x 4 11 15 13,3 25 0,2 F3267 2,5 x 4 13 20 7,98 15 0,3 F653 4 x 4 15 30 4,96 9,5 0,4 F654 6 x 4 17 35 3,30 6,4 0,5 F655 10 x 4 20 50 1,91 3,8 0,7 F656 16 x 4 23 65 1,21 2,4 1 F657 25 x 4 26,2 95 0,78 0,87 1,4 F658 Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. 52 2 VOLTEX CATALOGUE

GENERAL WELDING CABLE EPM/CM or EPM/CR 100V Cable Description Single core flexible copper conductors to SANS 1411 Part 1, EPM (Ethylene-propylene monomer) insulated, CM (Chloronated Polyethylene) or CR (Polychloropene) sheathed, heavy duty welding cables. Installation Information Heavy duty welding for: Indoor and outdoor electric welding equipment. Technical Data Properties Specification : SANS 1576 Voltage Rating :100V AC or DC to earth for welding applications Core Identification : EPM/CM - Outer CM sheath is coloured : EPM/CP - EPM insulation is coloured and CR sheath is black Packaging : 100m shrink - wrapped coils Physical Properties Conductor Dimensions Colour Conductor Size Maximum Diameter of Wires Diameter Maximum Resistance of Untinned Conductor at 20 C Nominal Thickness of Insulation Overall Diameter Cable Mass (mm 2 ) (mm) (Ω/km) (mm) (kg/m) Green 16 0,31 5,2 1,210 2,0 9,2 0,25 Blue 25 0,31 7,1 0,780 2,0 11,1 0,35 Grey 35 0,31 8,5 0,554 2,0 12,5 0,45 Red 50 0,31 10,4 0,386 2,2 14,8 0,60 Brown 70 0,31 11,6 0,272 2,4 16,4 0,75 Yellow 95 0,31 14,1 0,206 2,6 19,3 1,10 Black 120 0,51 15,6 0,161 2,8 21,2 1,40 Electrical Properties Size Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 85 C. Assumed duty cycle period 5 minutes. Derating of maximum current for other ambient temperatures. use rating factor X as given below: Class of Welding Automatic Manual Very Semi-automatic Intermittent Maximum Current Rating (A) for Duty Cycles of: Ambient Temperature, C : 25 30 35 40 45 Rating Factor, X : 1,04 1,00 0,95 0.91 0,85 DC Voltage Drop (mm 2 ) 100% 85% 60% 30% 20% mv/a/m 16 131 134 142 172 199 1,6 25 177 182 197 246 289 1,0 35 220 229 252 322 380 0,8 50 280 293 327 426 507 0,6 70 346 364 411 546 654 0,5 95 422 446 508 681 819 0,4 120 493 523 599 809 976 0,3 Code Table Colours (mm 2 ) 16 Green F692 25 Blue F693 35 Grey F694 50 Red F696 70 Brown F697 95 Yellow F698 120 Black F2464 150 Black F2465 VOLTEX CATALOGUE 53 3

HO7RN-F FLEXIBLE GENERAL PURPOSE TRAILING CABLE Cable Construction Flexible copper conductors (Class 5 Annealed Copper Conductors), EPR based rubber insulated, cores laid up and Neoprene Rubber sheathed. Application This cable is suitable for use in dry, humid or wet environments and in open air. This cable is suitable for medium mechanical stress, in workshops and general industry. It is mostly used on industrial machinery, however is also suitable for use on home tools, electric motors and portable generators. HO7RN-F cable is highly suitable as a general purpose cable for temporary power supply, but also for use when installing cable in limited space or for use with small bending radius. Neoprene (CR) provides many of the attributes of natural rubber in jacketing but it does offer significantly better heat, ozone-corona, weather, chemical, oil and flame resistance. The mechanical characteristics of Neoprene makes it highly suited to a diverse range of applications including jacketing for all types of heavy duty and extra-heavy-duty mining cables. Max continuous operating conductor temperature in normal use: +60ºC (in every case of mobile installation) +85ºC (fixed protected installation) +200ºC (in short circuit) Permissible current rating is measured for an ambient temperature of 30ºC and a maximum operating and conductor temperature of 85ºC. Single Core HO7RN-F 300/500V Size Volt Drop mv/a/m Nominal Outer Diameter Cable Weight Resistance (Untinned) Current Carrying Capacity (Air at 30º) (mm 2 ) 1OI 3OI (mm) (kg/km) Ω/km (A) Product Code 1,5 23,30 20,18 5,90 50 13,3000 23-2,5 14,00 12,12 6,50 65 7,9800 32-4 8,70 7,53 7,40 89 4,9500 43-6 5,90 5,11 8,10 115 3,3000 56-10 3,40 2,94 10,40 190 1,9100 77-16 2,20 1,91 11,62 259 1,2100 102 F1448 25 1,40 1,21 13,74 375 0,7800 136 F1499 35 1,04 0,90 15,35 492 0,5440 168 F1500 50 0,75 0,65 17,68 662 0,3860 203 F1501 70 0,56 0,48 20,00 908 0,2720 254 F1503 95 0,50 0,40 22,12 1171 0,2060 315 F1504 120 0,36 0,31 24,54 1445 0,1610 363 F1505 150 0,31 0,27 26,87 1783 0,1290 416 F1506 185 0,28 0,24 28,89 2125 0,1060 475 F1507 240 0,23 0,20 32,62 2733 0,0801 559 F1508 300 0,20 0,17 36,46 3348 0,0641 637 F1511 400 0,18 0,16 42,10 4410 0,0495 752-500 0,16 0,14 45,80 5600 0,0391 833 F1513 For items marked with a dash (-) please enquire at branch or reference website. 54 2 VOLTEX CATALOGUE

HO7RN-F FLEXIBLE GENERAL PURPOSE TRAILING CABLE Multicore HO7RN-F 450/750V Size Cores Nominal Outer Diameter Mass Max Resistance at 20ºC Volt Drop (mv/a/m) Current Carrying Capacity (Air at 30ºC) (mm 2 ) (mm) (kg/km) Ω/km 3OI (A) 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Product Code 2 9,10 109 23 F1388 3 9,78 134 23-4 10,76 166 13,3000 20,18 21 F2244 5 11,80 206 21 F1389 7 14,75 315 16 F1390 2 10,80 158 32 F1396 3 11,58 196 32-4 12,73 241 7,9800 12,12 29-5 13,96 297 29-7 17,11 445 20 F1397 2 12,40 217 43-3 13,30 271 43-4 14,63 336 4,9500 7,53 38-5 16,25 422 38 F1402 7 19,64 618 25 F1403 2 14,20 297 56-3 14,78 355 56 F1405 4 16,44 449 3,3000 5,11 50-5 18,07 567 50 F1406 7 21,00 810 38 F1407 2 20,40 573 77-3 20,73 674 77 F1408 1,9100 2,94 4 22,57 833 68 F1409 5 24,75 1010 68 F1410 2 23,00 774 102-3 23,26 913 1,2100 1,91 102 F1411 4 25,36 1138 92 F1412 5 28,01 1400 92 F1413 2 27,40 1110 136-3 27,69 1324 136 F1414 0,7800 1,21 4 30,75 1714 122 F1415 5 33,91 2096 122 F1416 3 30,95 1754 168 F1417 0,5540 0,90 4 34,23 2204 150 F1418 3 35,80 2409 203 F1420 0,3860 0,65 4 39,56 3029 182 F1421 3 40,45 3211 262-0,2720 0,48 4 44,89 4121 232 F1422 3 44,90 4170 320-0,2060 0,43 4 50,36 5361 281 F1423 3 49,15 5080 373-0,1610 0,31 4 55,33 6546 325 F1424 3 53,70 6220 432-0,1290 0,27 4 60,87 8095 373 F1425 3 58,90 7730 495-0,1060 0,24 4 65,70 9652 425 F1426 3 66,80 9780 587-0,0801 0,20 4 75,50 12 614 500 F1435 3 74,10 12 620 680-0,0641 0,17 4 82,20 14 800 585 - For items marked with a dash (-) please enquire at branch or reference website. Additional core sizes are available on request. VOLTEX CATALOGUE 55 3

BARE COPPER Earth Wiring Cable Cable Description High conductivity plain soft stranded copper conductors to SANS 1411. Installation Information For the wiring of earthing circuits where general house wiring is used. 1,5mm² - Amps at 30 C = 20 2,5mm² - Amps at 30 C = 27 4,00mm² - Amps at 30 C = 37 6,00mm² - Amps at 30 C = 70 Technical Data for Typical Guideline Values Properties Specifications : SANS 1411-1 Temperature Range : -10 C to 70 C Sheath Identification : Copper Packaging : 1,5mm² - 6mm², 5kg & 25kg coils : 10mm² - 16mm², 25kg & 500kg wooden drums : 25mm² - 240mm² & 500kg wooden drums Conductor Size Nominal Stranding Metres (mm²) (No. x Diameter) (m/kg) 1,5 7/0,53 72,22 2,5 7/0,66 46,62 4 7/0,85 27,46 6 7/1,04 18,75 10 7/1,35 11,13 16 7/1,67 7,27 25 19/1,38* 4,54 35 19/1,62* 3,34 50 19/1,88* 2,46 70 19/2,28* 1,56 95 19/2,50 1,13 120 37/2,03 0,91 150 37/2,28 0,739 185 37/2,50 0,599 240 37/2,98 0,450 Compacted conductors. Example Customer Enquiry: 180m of 70mm² Copper Earth Wire. 1kg of 70mm² Copper is therefore = 1,56m. So 180m divided by 1,56 = 115,38kg say 115kg. Kg Metre (mm 2 ) 1,5 F216 F4202 2,5 F217 F797 4 F218 F786 6 F219 F787 10 F220 F788 16 F221 F789 25 F222 F790 35 F223 F791 50 F224 F792 70 F225 F793 95 F226 F794 120 F227 F795 150 F228 F4240 185 F229 F4242 56 2 VOLTEX CATALOGUE

BELLS AND MAINS LOW VOLTAGE PVC CABLE Useful Technical Data Flamosafe Range of Fire Preformance Electric Cables Description FR (Flame Retardant) Red Stripe cables are designed to reduce the spread of fire along a cable tray or duct. However, when these cables burn, they give off large quantities of toxic gases and smoke. (FYRGARD ) (Common Type) LHFR (Low Halogen) Blue Stripe cables have specially formulated PVC that reduces the emission of hydro-chloric acid during burning of the cables. (LOHAL ) NHLSFR (Non Halogen) White Stripe cables are designed to reduce flame propagation and smoke in those instances where a fire may develop. By replacing the standard PVC with XLPE insulation and EVA bedding and outer sheath, no HCI gases will be liberated during the burning of the cables. (LOTOX ) Flamosafe, Fyrgard, Lohal and Lotox are registered trademarks of Aberdare Cables, a member of the Powertech Group. VOLTEX CATALOGUE 57 3

BELLS AND MAINS LOW VOLTAGE PVC CABLE PVC PVC SWA PVC (FR) 600/1000V Electrical and physical properties of 3 and 4 core PVC insulated PVC bedded *SWA PVC sheathed 600/1000V cables with aluminium or copper conductors and manufactured to SANS 1507-3. * Where the armouring of cable is used as the earth continuity path, it may be necessary to replace some of the steel wires with tinned copper wires (ECC) or to use a supplementary earth continuity conductor. Installation Information Residential applications, factories, office blocks and shopping centres. Technical Data D1 D2 d D1 = Diameter over bedding sheath d = Diameter of armour wire D2 = Diameter over outer sheath Copper Conductors Size Current Rating Electrical Properties Impedance Volt Drop 1 Sec Short Circuit Rating Physical Properties Nominal Diameters D1 d D2 Mass Ground Ducts Air 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core (mm²) (A) (Ω/km) (mv/a/m) (ka) (mm) (kg/km) 1,5 24 20 19 14,48 25,080 0,17 8,51 9,33 1,25 1,25 14,13 14,95 448 501 2,5 32 26 26 8,87 15,363 0,28 9,61 10,56 1,25 1,25 15,23 16,18 522 597 4 42 34 35 5,52 9,561 0,46 11,40 12,57 1,25 1,25 17,02 18,39 667 762 6 53 43 45 3,69 6,391 0,69 12,58 13,90 1,25 1,25 18,40 19,72 790 910 10 70 58 62 2,19 3,793 1,15 14,59 16,14 1,25 1,25 20,41 21,96 996 1169 16 91 75 83 1,38 2,390 1,84 16,55 19,18 1,25 1,25 22,37 25,92 1295 1768 25 119 96 110 0,8749 1,515 2,87 19,46 21,34 1,60 1,60 26,46 28,34 1838 2196 35 143 116 135 0,6335 1,097 4,02 20,89 23,97 1,60 1,60 27,89 31,17 2215 2732 50 169 138 163 0,4718 0,817 5,75 24,26 28,14 1,60 1,60 31,46 36,54 2871 3893 70 210 171 207 0,3325 0,576 8,05 27,07 31,29 2,00 2,00 35,47 40,09 3617 4837 95 251 205 251 0,2460 0,427 10,92 31,19 35,82 2,00 2,00 39,99 44,62 4901 6115 120 285 234 290 0,2012 0,348 13,80 33,38 38,10 2,00 2,00 42,18 47,40 5720 7269 150 320 263 332 0,1698 0,294 17,25 36,68 42,05 2,00 2,00 45,98 52,65 6908 9250 185 361 298 378 0,1445 0,250 21,27 40,82 46,75 2,50 2,50 51,12 57,45 8690 11039 240 416 344 445 0,1220 0,211 27,60 46,43 53,06 2,50 2,50 57,13 64,16 10767 13726 300 465 385 510 0,1090 0,189 34,50 51,10 58,53 2,50 2,50 62,20 70,13 12950 16544 Aluminium Conductors Size Current Rating Electrical Properties Impedance Volt Drop 1 Sec Short Circuit Rating Physical Properties Nominal Diameters D1 d D2 Mass Ground Ducts Air 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core (mm²) (A) (Ω/km) (mv/a/m) (ka) (mm) (kg/km) 25 90 73 80 1,4446 2,502 1,80 17,76 20,65 1,60 1,60 24,76 27,65 1301 1554 35 108 87 99 1,0465 1,813 2,52 19,33 21,93 1,60 1,60 26,33 29,13 1477 1757 50 129 104 119 0,7749 1,342 3,61 21,87 25,05 1,60 1,60 29,07 32,25 1782 2150 70 158 130 151 0,5388 0,9333 5,05 24,76 29,27 1,60 1,60 31,96 37,67 2132 2930 95 192 157 186 0,3934 0,681 6,86 28,68 33,73 2,00 2,00 37,08 42,53 2908 3647 120 219 179 216 0,3148 0,545 8,66 31,09 35,44 2,00 2,00 39,89 44,24 3328 4023 150 245 201 250 0,2607 0,452 10,83 33,99 39,39 2,00 2,50 42,79 49,69 3837 5276 185 278 229 287 0,2133 0,369 13,35 37,80 44,51 2,00 2,50 47,10 54,81 4557 6231 240 324 268 342 0,1708 0,296 17,32 42,60 50,04 2,50 2,50 52,90 61,14 5977 7550 Under short circuit conditions a maximum conductor temperature of 160ºC is allowed for a maximum of 1 second. 58 2 VOLTEX CATALOGUE

BELLS AND MAINS LOW VOLTAGE PVC CABLE Definition of ECC Cable ECC - Earth Continuity Conductor (SANS 1507-3) When an improved conductivity in the earth continuity circuit of (SWA) steel wire armoured multicore cable is required, an appropriate number of steel armour wires may be replaced by tinned hard drawn copper wires of the same nominal diameter. The copper wires shall comply with the relevant requirements of Sans 1411-1. D1 D2 d PVC PVC SWA ECC PVC (mm²) 2 Core 3 Core 4 Core 1,5 F43 F45 F47 2,5 F50 F52 F54 4 F57 F59 F61 6 F64 F66 F68 10 F71 F73 F75 16 F77 F79 F81 25 F374 F376 F380 35 F381 F383 F387 50 - F389 F393 70 - F395 F399 95 - F401 F405 120 - F407 F410 150 - F412 F415 185 - - F419 240 - - F422 300 - - F850 LHFR (Low Halogen) Blue Stripe cables have specially formulated PVC that reduces the emission of hydro-chloric acid during burning of the cables. (LOHAL ) D1 D2 d COPPER PVC PVC SWA PVC (mm²) 2 Core 3 Core 4 Core 7 Core 12 Core 19 Core 27Core 37 Core 1,5 F1793 F1794 F1795 F1814 F1815 F1816 F1818 F1819 2,5 F1797 F1798 F1799 F1801 F1832 F1833 F1835 F1836 4 F1782 F1783 F1784 F1786 F1844 F1845 F1846 F1847 6 F1788 F1789 F1790 F1791 - - - - 10 F1804 F1805 F1806 - - - - - 16 F1820 F1821 F1822 - - - - - 25 - F1830 F1831 - - - - - 35 - F1841 F1843 - - - - - 50 - F1850 F1851 - - - - - 70 - F1852 F1853 - - - - - 95 - - F1856 - - - - - 120 - F1807 F1808 - - - - - 150 - F1812 F1813 - - - - - 185 - F1823 F1824 - - - - - 240 - F1828 F1829 - - - - - 300 - F1838 F1840 - - - - - Items above with (-) in the codes column, as well as aluminium are available on special request. VOLTEX CATALOGUE 59 3

MULTICORE PVC CABLE Low-Voltage Armoured Cable 600/1000V Electrical and physical properties of Multicore PVC Insulated PVC Bedded SWA PVC sheathed 600/1000V cables with stranded copper conductors manufactured to SANS 1507-3. d D1 = Diameter over bedding sheath d = Diameter of armour wire Technical Data D1 D2 D2 = Diameter over outer sheath 1.5mm 2 Electrical Properties Physical Properties Multicore Cables Current Rating Nominal Diameters Product Impedance Capacitance Mass Ground Ducts Air (mm) Code No. of Cores (A) (Ω/km) (nf/km) D1 d D2 (kg/km) 2 29 23 22 14,4782 422 8,1 1,25 13,8 422 F42 3 24 20 19 14,4782 422 8,6 1,25 14,3 456-4 24 20 19 14,4782 422 9,5 1,25 15,1 510-5 21 17 17 14,4782 422 10,3 1,25 15,8 577-6 20 16 16 14,4782 422 11,4 1,25 17,0 613-7 18 15 15 14,4782 422 11,4 1,25 17,0 629 F48 8 17 14 14 14,4782 422 12,6 1,25 18,2 710-10 16 13 13 14,4782 413 14,8 1,25 20,7 837-12 15 12 12 14,4782 413 15,3 1,25 21,2 901 F424 14 14 11 12 14,4782 413 16,2 1,60 22,0 980-19 12 10 11 14,4782 379 19,2 1,60 25,9 1404 F425 24 11 9 10 14,4782 379 22,4 1,60 29,3 1687-27 11 8 10 14,4782 379 22,9 1,60 29,8 1783 F427 30 10 8 9 14,4782 379 23,7 1,60 30,7 1867-37 9 7 9 14,4782 379 25,9 1,60 32,8 2153-2.5mm 2 Multicore Cables Electrical Properties Physical Properties Current Rating Nominal Diameters Impedance Capacitance Mass Ground Ducts Air (mm) No. of Cores (A) (Ω/km) (nf/km) D1 d D2 (kg/km) 2 37 31 31 8,8668 487 9,0 1,25 14,7 475 F49 3 32 26 26 8,8668 487 9,6 1,25 15,2 524-4 32 26 26 8,8668 487 10,6 1,25 16,2 606-5 27 22 22 8,8668 487 11,5 1,25 17,0 690-6 25 20 21 8,8668 487 12,7 1,25 18,5 737-7 24 19 20 8,8668 487 12,7 1,25 18,5 756 F55 8 22 18 19 8,8668 487 13,0 1,25 18,9 806-10 21 17 18 8,8668 477 16,6 1,60 22,5 1000-12 19 15 17 8,8668 434 18,1 1,60 24,8 1306 F429 14 18 14 16 8,8668 434 19,0 1,60 25,7 1421-19 16 13 14 8,8668 434 21,4 1,60 28,1 1695 F430 24 14 12 13 8,8668 434 25,1 1,60 32,0 2053-27 14 11 13 8,8668 434 25,7 1,60 32,6 2181 F431 30 13 10 12 8,8668 434 26,6 2,00 34,8 2594 F861 37 12 10 11 8,8668 410 29,4 2,00 37,6 3011 - Product Code Items above with (-) in the codes column, as well as aluminium are available on special request. 60 2 VOLTEX CATALOGUE

MULTICORE PVC CABLE 4mm 2 Multicore Cables No. of Cores Electrical Properties Physical Properties Current Rating Nominal Diameters Impedance Capacitance Ground Ducts Air (mm) (A) (Ω/km) (nf/km) D1 d D2 (kg/km) 2 50 41 41 5,5171 487 10,2 1,25 16,3 597 F56 3 42 34 35 5,5171 487 10,9 1,25 17,0 669-4 42 34 35 5,5171 487 12,3 1,25 18,4 764-5 35 28 29 5,5171 487 13,6 1,25 19,7 884-6 33 27 28 5,5171 487 14,9 1,25 21,0 961-7 31 25 26 5,5171 487 14,9 1,25 21,0 986 F62 8 29 24 25 5,5171 487 18,1 1,25 24,2 1079-10 27 22 24 5,5171 477 20,2 1,60 27,0 1251-12 25 20 22 5,5171 434 20,4 1,60 28,2 1211 F860 14 23 19 21 5,5171 434 22,8 1,60 29,6 1885-19 21 16 19 5,5171 434 24,9 2,00 32,5 2282 F1563 24 19 15 18 5,5171 434 31,0 2,00 38,6 3113-27 18 14 17 5,5171 434 32,2 2,00 39,8 3354-30 17 14 17 5,5171 434 35,8 2,00 43,4 3966-37 16 13 15 5,5171 410 36,2 2,00 43.8 4124 - Mass Product Code 6mm 2 Multicore Cables No. of Cores Electrical Properties Physical Properties Current Rating Nominal Diameters Impedance Capacitance Ground Ducts Air (mm) (A) (Ω/km) (nf/lm) D1 d D2 (kg/km) 2 62 51 53 3,6868 556 11,8 1,25 17,4 684 F63 3 53 43 45 3,6868 556 12,6 1,25 18,4 791-4 53 43 45 3,6868 556 13,9 1,25 19,7 911-5 44 35 37 3,6868 556 15,3 1,25 21 1054-6 40 33 36 3,6868 521 17,7 1,60 24,4 1376 - Mass Product Code PVC Current Ratings are based on the following Environmental Parameters Maximum Sustained Conductor Temperature Ground Temperature Ambient Air Temperature (Free Air Shaded) Ground Thermal Resistivity Minimum Trench or Duct Depth of Laying 70ºC 25ºC 30ºC 1,2 K.m/W 500mm Items above with (-) in the codes column, as well as aluminium are available on special request. VOLTEX CATALOGUE 61 3

TEXOPLAST FLAT CABLE - TPLF Cable Construction Conductor of copper, finely stranded to class 5/6, cores PVC insulated, laid up in parallel, certain multicores have core groups separated by a web, PVC outer sheath, black. Core Identification: Up to 4 cores : coloured 5 cores and more : black with white numbering, earth core Cable description bearing - O without earth core Cable description bearing - J with green/yellow earth core Application: TPLF cables can be used in dry, damp or wet environments as power, control and instrumentation cables. TPLFC cables qualify as TPLF but offer screened cores, pairs or bundled core assemblies (b) of up to 80% coverage. TPLFT cables qualify as TPLF but offer tension relief steel cores and fire retardant sheath. PVC flat cable is preferably used indoors, in electrification systems where it is subjected to lots of flexing in a single plane i.e. cranes, hoists, conveyor systems, machine tools, lifts etc. Technical Data Maximum operating Voltage AC up to 1,5mm² Maximum operating Voltage AC from 2,5mm² Maximum operating Voltage DC up to 1,5mm² Maximum operating Voltage DC from 2,5mm² Test Voltage AC 450V/750V 600V/1000V 675V/1125V 600V/1500V 3000V Condutor resistance to DIN/VDE 0295 Class 5 Temperature range mobile - 15 C to +70 C fixed - 40 C to + 70 C Current Capacity VDE 0100 Derating VDE 0100 Specification according to VDE 0281 Part 403+404 Minimum bending radius Tensile stress Marking mobile - 10x cable thickness fixed - 4x cable thickness not to exceed 15N/mm 2 of total core cross section of Type TPLF printed or embossed Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Weight (mm²) (mm) (mm) (kg/m) TPLF-J 4 x 1,5 0,26 5,5 x 15,5 0,15 4 x 2,5 0,26 5,9 x 19,0 0,22 4 x 4 0,31 7,1 x 22,0 0,31 4 x 6 0,31 7,8 x 25,0 0,42 4 x 10 0,41 9,9 x 31,5 0,67 4 x 16 0,41 11,2 x 36,5 0,95 4 x 25 0,41 13,0 x 42,5 1,42 4 x 35 0,41 17,0 x 50,0 2,00 4 x 50 0,41 20,0 x 63,0 2,96 4 x 70 0,509 23,0 x 72,0 3,96 4 x 95 0,509 25,0 x 83,0 5,32 7 x 4 0,31 7,1 x 38,0 0,54 7 x 6 0,31 7,8 x 43,0 0,74 8 x 1,5 0,26 5,2 x 30,0 0,29 8 x 2,5 0,26 5,9 x 38,0 0,42 12 x 1,5 0,26 5,2 x 41,5 0,39 12 x 2,5 0,26 5,9 x 52,0 0,60 62 2 VOLTEX CATALOGUE

TEXOPLAST FLAT CABLE - TPLF Flat Cable - TPLF Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Weight (mm²) (mm) (mm) (kg/m) TPLFC - J Screened 4 x 1 0,21 5,0 x 13,9 0,13 6 x 2,5 0,26 9,9 x 36,7 0,58 8 x 1,5 0,26 6,0 x 32,4 0,38 12 x 1,5 0,26 6,0 x 52,0 0,61 TPLFCb - Screened 5 x (4 x 0,5) - O 0,21 9,2 x 35,5 0,52 7 x (4 x 0,5) - O 0,21 10,3 x 50,0 0,75 7 x (3 x 1) - J 0,21 10,3 x 50,0 0,76 14 x (4 x 0,5) - O 0,21 10,3 x 100,0 1,51 TPLFT - J 2 - Tension Relief Cores 4 x 1,5 0,26 5,5 x 20,0 20,0 4 x 16 0,41 11,2 x 51,4 51,4 12 x 1,5 0,26 6,4 x 50,2 50,2 Available on request. Lead times need to be confirmed at the time the order is placed. TEXOPLAST SPECIAL LIFT FLAT CABLES - TPLFY Special Lift Flat Cables - TPLFH (LWL) - O Cable Construction 1. Flexible PVC-insulated stranded cores, alternate left and right stranding lay, laid up in parallel. 2. Optical fibre cable (LWL). 3. Low-elastic supporting elements. 4. PVC outer sheath. 4 3 2 1 Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Maximum Weight Maximum Single Suspension Height (mm²) (mm) (mm) (kg/m) (m) TPLFH (LWL) - O 12 x 1 + 2LWL 0,2 + *100/140 µm 51 x 6,4 0,52 80 Special Lift Flat Cables - TPLFT (TELF) - O Cable Construction 1. 6-taped control cable groups comprising of bundled left and right hand laid assemblies of 5 flexible PVC-insulated cores laid around a manila rope centre, cores having an extra short lay, taped and laid up in parallel. 2. 1 - Telephone cable group which comprises of 4 flexible PVC insulated cores laid up around a central member in quad configuration, collectively screened and polyethylene sheathed. 3. High tensile steel carrier elements. 4. PVC outer sheath, cold resistant. 4 3 2 1 Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Maximum Weight Maximum Single Suspension Height (mm²) (mm) (mm) (kg/m) (m) TPLFH (telf) - O 34 x 1 0,15 76 x 11 1,15 220 Available on request. Lead times need to be confirmed at the time the order is placed. VOLTEX CATALOGUE 63 3

PENDANT CABLE - PVC Cable Construction Conductor of copper, finely stranded to class 5/6 - cores PVC insulated - laid up in shorty corelay - taped - Nitrile outer sheath with integrated tension relief stainless steel ropes positioned opposite each other Core Identification: All cores are black and numbered with white print Cable description bearing - J with green/yellow earth core Application Pendant Cable can be used in dry, damp or wet enviroments as power and control cable. The usage extends to hoists, cranes, stacking systems, conveyor systems, elevators etc. Technical Data Max. operating Voltage AC Max. operating Voltage DC Test Voltage AC 600 V 900 V 3000 V Condutor resistance To DIN/VDE 0295 Class 5/6 Temperature range Mobile - 20 C to + 70 C Current Capacity VDE 0100 Derating VDE 0100 Specification According to VDE 0250 Min. bending radius tensile stress Marking Mobile 15x cable thickness Not to exceed 15N/mm 2 to VDE total core cross section Embossed Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Weight (mm²) (mm) (mm) (kg/m) PENDANT - J - Yellow - Class 5 27 x 1 32 x 0,20 21,7-34, 0 0,70 8 x 1,5 30 x 0,25 16,0 25,5 0,43 12 x 1,5 30 x 0,25 17,0 28,0 0,51 20 x 1,5 30 x 0,25 21,5 34,0 0,72 PENDANT - J - Black - Class 6 20 x 1,5 84 x 0,15 21,5 34,0 0,73 Available on request. Lead times need to be confirmed at the time the order is placed. 64 2 VOLTEX CATALOGUE

SINGLE CORE PVC PVC CABLE Flexible Wiring 300/500V and 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with general purpose grade PVC in plain colours to SANS 1411 Part 2. Installation Information For the wiring of : Industrial Buildings Control Panels Technical Data Properties Specifications : SANS 1507-3 Temperature Range : -10 C to 70 C Voltage Rating : 600/1000V Sheath Identification : Black Packaging : 300/500m Drums D1 = Diameter over conductor D2 = Diameter over PVC sheath D1 D2 Cables A.C. or D.C. Cables in Trefoil Formation Rated Nominal Nominal Impedance Voltage Drop Voltage Drop Area Diameters Mass Product Current Rating per Amp Current Rating per Amp Code per metre per metre (mm 2 ) D1 D2 (kg/km) (Ω/km) Ground Air (mv) Ground Ducts Air (mv) 25 5,95 11,91 366 0,8767 118 133 1,7 127 91 109 1,50-35 7,00 12,96 469 0,6356 156 165 1,3 153 109 136 1,10-50 8,15 15,15 632 0,4745 186 203 0,9 180 130 171 0,80-70 9,79 16,57 880 0,3356 232 251 0,7 221 166 214 0,60-95 11,54 19,04 1160 0,2500 281 313 0,5 265 208 271 0,40-120 12,96 20,24 1413 0,2054 324 362 0,4 301 237 316 0,30-150 14,39 22,07 1734 0,1734 370 414 0,3 338 267 366 0,30 F1956 185 16,10 24,80 2145 0,1499 424 482 0,3 381 305 433 0,20 F1957 240 18,71 27,81 2725 0,1268 498 578 0,2 442 357 525 0,20 F1960 300 21,45 30,75 3375 0,1131 566 660 0,2 499 404 604 0,20 F1963 400 24,30 34,10 4395 0,1028 651 704 0,2 565 442 639 0,20 F1967 500 26,51 37,13 5299 0,0963 740 821 0,2 634 506 752 0,20 F1969 630 33,15 43,62 6965 0,0890 836 960 0,2 718 580 886 0,10 F1972 PVC Current Ratings are based on the following Environmental Parameters Maximum Sustained Conductor Temperature Ground Temperature (ºC) Ambient Air Temperature Ground Thermal Resistivity Minimum Trench or Duct Depth of Laying 70ºC 25ºC 30ºC 1,2 K.m/W 500mm Items above with (-) in the codes column, as well as aluminium are available on special request. Rating based on two touching cables installed in a duct. Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. VOLTEX CATALOGUE 65 3

SINGLE CORE XLPE PVC CABLE General Purpose Wire 600/ 1000V Cable Description High conductivity annealed stranded or solid copper conductors to SANS 1411 Part 1. Insulated with XLPE plain colours to SANS 1411 Part 4. Installation Information For the wiring of : Industrial Buildings Control Panels Technical Data Properties Specifications : SANS 1507-4 Temperature Range : -10 C to 90 C Voltage Rating : 600/1000V Sheath Identification : Black Packaging : 300/500m Drums D1 = Diameter over conductor D2 = Diameter over PVC sheath D1 D2 Rated Area Cables A.C. or D.C. Cables in Trefoil Formation Nominal Nominal Diameters Impedance Voltage Drop Voltage Drop Mass Ground Current Rating per Amp Current Rating per Amp per metre per metre (mm 2 ) D1 D2 (kg/km) (Ω/km) Ground Air (mv) Ground Ducts Air (mv) 25 5,95 11,81 328 0,8767 169 162 2,0 151 103 143 1,7-35 7,00 12,86 426 0,6356 205 202 1,4 181 125 179 1,2-50 8,15 14,38 567 0,4745 245 255 1,0 213 154 229 0,9-70 9,79 16,22 824 0,3356 302 313 0,7 260 192 284 0,6-95 11,54 17,97 1071 0,2500 366 380 0,5 312 233 346 0,5-120 12,96 19,82 1304 0,2054 422 441 0,4 355 268 402 0,4 F1955 150 14,39 21,42 1628 0,1734 480 508 0,4 397 305 465 0,3-185 16,10 23,63 1995 0,1499 554 585 0,3 449 345 537 0,3 F1959 240 18,71 26,69 2461 0,1268 656 704 0,2 522 406 648 0,2 F1961 300 21,45 30,05 3182 0,1131 766 804 0,2 589 459 741 0,2 F1965 400 24,30 33,30 4117 0,1028 902 874 0,2 668 511 805 0,2 F1968 500 26,51 36,33 5032 0,0963 1040 1013 0,2 750 583 935 0,2 F1971 630 33,15 42,79 6641 0,0890 1229 1205 0,2 848 680 1115 0,2 F1974 Product Code PVC Current Ratings are based on the following Environmental Parameters Maximum Sustained Conductor Temperature Ground Temperature (ºC) Ambient Air Temperature Ground Thermal Resistivity Minimum Trench or Duct Depth of Laying 90ºC 25ºC 30ºC 1,2 K.m/W 500mm Items above with (-) in the codes column, as well as aluminium are available on special request. Rating based on two touching cables installed in air. Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 90 C. 66 2 VOLTEX CATALOGUE

ARMADAC PVC PVC SWA PVC (FR) Black/Red 1.9/3.3kV d Cable Description Electrical and physical properties of 3 core PVC insulated PVC bedded SWA PVC sheathed 1.9/3.3kV cables with copper conductors and manufactured to D1 = Diameter over bedding sheath SANS 1507-3. d = Diameter of armour wire D1 D2 = Diameter over outer sheath D2 Installation Information The cost effectiveness of transferring power over long distances through intermediate step-up and step-down systems is desirable for the electrification of industrial and residential installations, including game lodges and agricultural industry applications. Armadac consists of 3 circular stranded plain soft copper conductors, PVC insulated, PVC bedded, Steel Wire Armoured, PVC sheathed, 1.9/3.3kV manufactured to SANS 1507-3. Ideally utilised for the transfer of electricity over long distances. Advantages of using an intermediate voltage cable over the conventional 400V 3-phase system offered by the increased voltage of 3,3kV include the fact that volt drop will be considerably lower and small conductor sizes (10mm², 16mm² or 25mm²) will suffice for most applications. The Armadac cable is steel wire armoured and provides a robust mechanical protection to the cable, hence it is suitable to be installed underground. Furthermore, Armadac offers additional protection against attack by rodents and other animals as provided by the steel wire armouring. The steel wire armouring can also be utilised as an earth continuity path, therefore eliminating the need for an external earth conductor. Armadac makes use of circular cores which limits electrical stress in the insulation and also incorporates a flame retardant PVC Sheath, which limits the spread of fire. Properties Specifications : SANS 1507-3 Temperature Range : -10 C to 70 C Voltage Rating : 1900/3300V Core Identification : Red, Yellow, Blue Packaging : Available on 500m wooden drums Technical Data Electrical Properties Physical Properties Current Rating 1 Sec Nominal Diameters Impedance Short Volt Drop Ground Ducts Air (Z) Circuit D1 d D2 Rating Approx. Mass Product Code (mm 2 ) (A) (Ω/km) (mv/a/m) (ka) (mm) (kg/km) 10 68 58 60 2,19 3,793 1,4 20,7 1,6 27,3 1543 F2809 16 91 76 81 1,38 2,390 2,2 22,8 1,6 29,6 1859 F2810 25 113 95 103 0,8749 1,515 3,4 24,9 1,6 31,7 2221 F2811 Recommended depth of lay 500mm. Soil thermal resistivity 1.2 km/w. Soil temperature at 25 C. In ground at 500mm depth. Armadac is a registered trademark of Aberdare Cables, a member of the Powertech Group. VOLTEX CATALOGUE 67 3

AIRDAC SNE CABLE House Service Connecting Cable with or without Pilot Cores Cable Description Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethylene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS 1507-6. Technical Data Small overall diameter - concentric construction (SNE - Seperate Neutral Earth). Lower mass - due to smaller diameter - no steel wire armour. Increased safety - reliable earthing. Improved reliability - UV stable sheath and core insulation and water blocked. Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer. Easy strip with nylon ripcord. Size Phase Conductor Resistance (Ohm/km) DC Earth Size Electrical Properties Neutral Size Phase Core Impedance Current Rating Pilot Cores (No. x OD) Solid at 20 C (mm²) (mm²) (Z) (Ohm/km) (A) (mm) 10 1,90 7,5 10 2,34 50 2 x 1,13 F211 16 1,20 10 16 1,47 70 2 x 1,13 F215 Mechanical Properties Size Phase Conductor }No. x OD{ Nominal Insulation Thickness Neutral Conductor }No. x OD{ Earth Conductor {No. x OD} Nominal Sheath Thickness Cable OD Cable Mass )mm( )mm( )mm( )mm( )mm( )mm( (kg/km) 10 7 x 1,35 1,0 7 x 1,33 3 x 1,78 1,6 12,8 320 16 7 x 1,67 1,0 7 x 1,76 3 x 2,20 1,6 14,5 485 AIRDAC II CNE CABLE House Service Connect Cable Description Circular stranded hard-drawn copper phase conductor, XLPE insulated with concentrically arranged bare earth conductors. Polyethylene sheathed 600/1000 V house service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS 1507-6. Technical Data Small overall diameter - concentric construction. Lower mass - due to smaller diameter - no steel wire armour. Increased safety - reliable earthing. Improved reliability - UV stable sheath and core insulation. Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer. Easy strip with nylon ripcord. Electrical Properties Size Phase Conductor Resistance Phase Core Impedance Current Rating Symmetrical Short Circuit Rating for 1s (Ohm/km) DC at 20 C (Z) (Ohm/km) (A) ka 4 4,80 5,88 30 0,572 F207 10 1,90 2,34 50 1,431 F210 Mechanical Properties Size Phase Conductor {No. x OD} Nominal Insulation Thickness Earth Size Earth Conductor {No. x OD} Nominal Sheath Thickness Cable OD Cable Mass )mm( )mm( (mm²) )mm( )mm( )mm( )kg/km( 4 7 x 0,92 1,0 4 8 x 0,85 1,4 9,0 121 10 7 x 1,45 1,0 10 18 x 0,85 1,4 11,0 249 In air, with 30 C ambient with maximum conductor temperature 90 C. Airdac is a registered trademark of Aberdare Cables, a member of the Powertech Group. 68 2 VOLTEX CATALOGUE

AERIAL BUNDLE CONDUCTOR (ABC) CABLE Cable Description Supporting-core system consists of three phase cores of hard-drawn stranded compacted aluminium conductors insulated with carbon-loaded XLPE laid up around an aluminium-alloy supporting core insulated with carbon loaded XLPE to ensure UV protection. Additional sub-conductors optional in both self-supporting and supporting-core systems. Installation Information Economical Flexible Safe Vandal proof Durable Aesthetically pleasing Adaptable Supporting Core Properties Specification : SANS 1418 Part 1 and 2 Temperature Range : -10 C to 80 C Voltage Rating : 600/1000V Core Identification : Phase 1, 2 and 3 indented Non strain-bearing neutral, 2 longitudinal ribs on opposite surfaces 0,5mm x 1,00mm Strain-bearing (supporting) neutral. 1 longitudinal rib on one surface 0,5mm x 1,00mm Packaging : Available on 500m wooden drums. Technical Data Based on 3 Core Plus Insulated Neutral Current Rating Short Circuit Rating Electrical Properties Conductor Resistance at 20 C Conductor Resistance (AC) at 80 C Supporting Core Size Supporting Core System Induction Reactance at 50Hz Impendance (z) at 50Hz at 80 C (mm 2 ) (A) (ka) (Ω/km) (Ω/km) (mm 2 ) (Ω/km) (Ω/km) 25 105 2,3 1,200 1,490 54,6 0,101 1,493 35 144 3,2 0,868 1,078 54,6 0,097 1,082 50 183 4,6 0,641 0,796 54,6 0,089 0,801 70 228 6,4 0,443 0,550 54,6 0,086 0,557 95 277 8,5 0,320 0,397 54,6 0,081 0,405 120 322 11,0 0,253 0,314 70 0,079 0,324 150 350 13,8 0,206 0,256 95 0,079 0,268 Mechanical Properties Conductor Core Supporting Core System Diameter Diameter Supporting Maximum Phase Cores Min Max Min Max Core Size Assembly Diameter Assembly Mass Design Load (mm 2 ) (mm) (mm 2 ) (mm) (kg/km) (kn) 25 5,6 6,5 8,4 9,6 54,6 26 507 6-35 6,6 7,5 9,8 11,1 54,6 28 612 6-50 7,7 8,6 10,9 12,3 54,6 32 730 6-70 9,3 10,2 12,9 14,3 54,6 34 944 6-95 11,0 12,0 14,6 16,2 54,6 38 1183 6-120 12,5 13,5 16,1 17,5 70,0 40 1600 8-150 13,9 15,0 17,5 19,2 95,0 44 1870 13 - Above Plus 25mm² Auxiliary Core 25 32 612-35 34 717-50 36 835-70 N/A N/A N/A N/A N/A 38 1049 N/A - 95 42 1288-120 50 1705-150 56 1975 - Temperature C 25 30 35 40 45 Factor 1,11 1,05 1,00 0,94 0,88 Items above with (-) in the codes column are available on special request. Also available in bare neutral, 1 core and insulated neutral, 2 core and insulated neutral and 3 core and insulated neutral configurations. For further details on our Aerial Bundle Conductor Range please see our website or your nearest branch. Continuous current ratings are given for ambient temperature of 35 C, and maximum conductor temperature of 80 C. For other ambient temperatures use adjoining rating factors. Short circuit ratings of 1 second duration, for a final conductor temperature of 130 C. Available in bare neutral configuration. VOLTEX CATALOGUE 69 3

OVERHEAD ALUMINIUM CONDUCTORS ACSR Aluminium Conductor Steel Reinforced Overview Aluminium conductors have achieved wide acceptance all over the world for use in overhead transmission and distribution lines. Generally a steel core is used with the aluminium to give the conductor mechanical strength. This arrangement is termed Aluminium Conductor Steel Reinforced or ACSR. Conductors comprised entirely of aluminium are known as All Aluminium Conductors or AAC. These conductors are extensively used for busbars in outdoor substations where spans are short. All Aluminium Alloy Conductors or AAAC consist of an alloying of aluminium to give a tensile strength in excess of that of AAC, allowing longer spans. These conductors are recommended for coastal areas where severe corrosion is a problem. Hard drawn aluminium in H9 temper is used in both ACSR and AAC. High strain steel wire is used in ACSR and this is sometimes protected from corrosion by an application of grease. Such measures are particularly adopted when the conductor is intended for use in aggressive environments as encountered in coastal regions. Physical and Electrical Properties for Popular ACSR Sizes Standing/ Equival. Overall Aluminium Mass Ultimate DC Current Wire Tensile Resistance Type Copper Area Diameter Area Rating Product Diameter (kg/km) Strength at 20 C Code (mm 2 ) (mm) (mm) (mm 2 ) Aluminium Steel Total (N) Ohms/km (A) Squirrel 12,90 6/1/2,11 6,33 20,98 57,70 27,50 85,20 8020 1,3677 130 F2042 Gopher 16,30 6/1/2,36 7,08 26,25 72,20 34,40 107 9610 1,0933 150 F2043 Fox 22,58 6/1/2,79 8,37 36,68 101 48,10 149 13100 0,7822 190 F2045 Ferret 25,81 6/1/3,00 9,00 42,41 117 55,60 173 15200 0,6766 210 F2046 Rabbit 32,26 6/1/3,35 10,05 52,88 145 69,40 214 18500 0,5426 240 F2047 Mink 38,71 6/1/3,66 10,98 63,13 174 82,80 257 21900 0,4546 260 F2048 Hare 64,52 6/1/4,72 14,16 104,98 289 138 427 36000 0,2733 360 F3362 6/4,72 - Dog 64,52 14,15 104,98 289 100 389 34700 0,2733 360 7/1,57 F2052 Wolf 96,77 30/7/2,59 18,13 158,06 438 292 730 69200 0,1828 470 F2057 Panther 129,00 30/7/3,00 21,00 212,06 588 391 970 90800 0,1363 560 F2995 Bear 161,30 30/7/3,35 23,45 264,42 733 488 1220 112000 0,1093 650 F2972 Goat 193,50 30/7/3,71 25,97 324,31 899 598 1500 136000 0,0891 730 F2059 Items above with (-) in the codes column are available on special request. For further details on our Overhead Aluminium Conductor Range please see our website or your nearest branch. Eskom marked product available on request. Lead times need to be confirmed at the time the order is placed. 70 2 VOLTEX CATALOGUE

CABLE GLAND INDICATOR The CONTRACTING TOOL which fits in your pocket. Voltex introduces, the essential new mobile app for electrical contractors. Now there s an app that will make your life easier, no matter where you are. Our mobile app gives electrical contractors a wealth of features*: Energy Efficiency Comparison Calculator Cable Gland Indicator Motor Control Chart Voltex Branch Locator with map *Indications are for guideline purposes only and may vary for individual results. Search for Voltex on Apple istore or Google Play and download now. Any queries please email info@voltex.co.za. iphone is a trademark of Apple Inc. registered in the U.S. and other countries. Google play is a trademark of Google Inc. your electrical connection www.voltex.co.za For extended & complete range visit www.voltex.co.za. Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes facebook.com/voltexsa andtwitter.com/voltexsa VOLTEX CATALOGUE 71 3

MV XLPE CABLE Medium Voltage Electric Cable 6.6kV to 33kV Properties and applications Due to the fact that Vultex XLPE insulation is resistant to high temperatures, it is obvious that higher temperatures are permissible in the cable. For XLPE, continuous conductor temperature up to 90 C are permissible, whilst for some hours a temperature of 130 C is permissible. In case of short-circuit the conductor can withstand considerably higher temperature (up to 250 C). This important specific characteristic, in contrast with those generally applicable to plastics, give XLPE insulated cables the following advantages: Suitable for a sustained conductor temperature of 90 C as a result of which a high current carrying capacity is obtained. Suitable up to 125 hours/annum, (no event being longer than 8 hours continuously) at a conductor temperature of 130 C so that emergency loads can be tolerated. No drainage problems. Clean handling. Relatively low cost per installed kva. Technical Data Electrical and Physical Properties of 3 core XLPE insulated PVC bedded, steel wire armoured, PVC sheathed 6.35/11kV cables to SANS 1339 Type A (Individually screened). Copper Conductors Standard Aluminium Conductors Current Rating (Ground) Electrical Properties Physical Properties Electrical Properties Physical Properties Impedance 1 Second Short Circuit Rating Diameter Overall Cable Mass Current Rating (Ground) Impedance 1 Second Short Circuit Rating Diameter Overall Cable Mass (mm 2 ) (A) (Ω/km) (ka) (mm) (kg/km) (A) (Ω/km) (ka) (mm) (kg/km) 25 140 0,9353 3,575 47,3 4655 35 170 0,6783 5,005 49,7 5215 50 200 0,5067 7,150 52,6 5895 155 8284 4,600 52,6 5015 70 240 0,3581 10,010 56,3 6995 190 5767 6,440 56,3 5635 95 290 0,2665 13,585 60,5 8170 225 4213 8,740 60,5 6340 120 325 0,2187 17,160 64,2 9370 255 3375 11,040 64,2 7045 150 360 0,1847 21,450 68,8 11 240 285 2795 13,800 68,8 8350 185 410 0,1571 26,455 72,8 12 775 320 2285 17,020 72,8 9245 240 470 0,1317 34,320 79,1 14 955 370 1821 22,080 79,1 10 580 300 520 0,1160 42,900 85,6 17 865 420 1535 27,600 85,6 12 070 72 2 VOLTEX CATALOGUE

PAPER INSULATED CABLES Paper Armoured (SWA or DSTA) Cable Paper Belted (up to 11kV) Cable Paper Screened (11kV and above) Cable Paper Unarmoured Cable Overview Paper insulated cables have been in use longer than any other type of cable insulation and, due to the reputation built up over the years, are still today a great favourite with engineers. When properly selected and correctly installed this product can be relied upon to provide a satisfactory and trouble-free performance for many years. Application Paper insulated lead covered cables can be used in many electrical distribution and reticulation applications. Special constructions are also available for use in specialised applications including: Electrical distribution in the petrochemical industry. Mining - a special construction for shaft installation is available with water blocking as well as flame retardancy. Fire and explosion hazardous areas. Submarine cables. Made to SANS 97. Technical Services Quality Assurance, Quality Control and Testing As electric power cables are manufactured to provide many years of service, it is necessary that the raw materials used are of the highest quality and conform to the rigid specifications laid down by South African Bureau of Standards. This also means that the production process has to be carefully controlled, particularly in areas where heating, drying or cooling cycles can be critical to the overall characteristics and electrical properties of the cable. Chemical, physical and electrical tests are carried out at various stages of manufacture. Final tests are all in accordance with SANS 97. Quality assurance systems are in compliance with SABS ISO 9000 series. Manufacturing Range Conductor Size 16mm 2 to 1000mm 2 Conductor Material Standard Copper Standard Aluminium No. Of Cores 1 3 Voltage 3.3kV 6.6kV 11kV 22kV 33kV Belted Electric Field Control Belted Screened Bedding Jute Hessian PVC EVA MDPE HDPE Armouring Aluminium Wire Steel Tape Steel Wire Steel Wired Serving Jute Hessian PVC EVA MDPE HDPE VOLTEX CATALOGUE 73 3

TABLE 17: 6.35/11KV 3 CORE GENERAL PURPOSE BELTED CABLES Fully impregnated armoured and served to SANS 97 Electrical Data Conductor Size (mm 2 ) 25 35 50 70 95 120 150 185 240 300 A.C Resistance Impedance Copper Conductors ohms/km 0,8700 0,6272 0,4633 0,3211 0,2316 0,1839 0,1494 0,1200 0,0921 0,0743 - Aluminium Conductors ohms/km 1,4419 1,0430 0,7703 0,5325 0,3849 0,3045 0,2481 0,1979 0,1513 0,1216 - Copper Conductors ohms/km 0,8779 0,6371 0,4751 0,3365 0,2499 0,2053 0,1739 0,1481 0,1245 0,1106 - Aluminium Conductors ohms/km 1,4421 1,0492 0,7777 0,5423 0,3972 0,3183 0,2640 0,2166 0,1734 0,1472 - Maximum Sustained Current Rating Ground Copper Conductors A 105 130 160 195 235 265 295 335 380 425 - Aluminium Conductors A 80 100 125 155 185 210 235 265 305 340 - Dimensional Data Conductor Size (mm 2 ) 25 35 50 70 95 120 150 185 240 300 Diameter Cable Mass Over Serving Copper Conductors Aluminium Conductors Over Lead Sheath mm 31,38 33,64 33,49 36,50 39,33 41,73 44,36 47,42 52,14 56,15 - Steel Tape Armoured Served mm 44,09 47,15 47,00 50,01 52,84 55,24 57,87 60,93 65,65 69,66 - Single Wire Armoured Served mm 44,89 48,15 48,00 51,01 53,84 56,24 60,17 63,23 67,95 74,52 - Steel Tape Armoured Served kg/km 4890 5710 6020 7080 8260 9440 10 770 12 290 14 480 16 940 - Single Wire Armoured Served kg/km 5110 6120 6440 7530 8760 9960 12 000 13 570 15 960 18 980 - Steel Tape Armoured Served kg/km 4415 5055 5195 5790 6505 7225 7980 8870 10 050 11 415 - Single Wire Armoured Served kg/km 4630 5465 5525 6240 7005 7745 9210 10 150 11 530 13 455 - TABLE 18: 11/11KV 3 CORE GENERAL PURPOSE BELTED CABLES Fully impregnated armoured and served to SANS 97 Electrical Data Conductor Size (mm 2 ) 25 35 50 70 95 120 150 185 240 300 A.C Resistance Impedance Maximum Sustained Current Rating Ground Copper Conductors ohms/km 0,8700 0,6272 0,4633 0,3211 0,2316 0,1839 0,1494 0,1200 0,0921 0,0743 - Aluminium Conductors ohms/km 1,4419 1,0430 0,7703 0,5325 0,3849 0,3045 0,2481 0,1979 0,1513 0,1216 - Copper Conductors ohms/km 0,8779 0,6371 0,4751 0,3365 0,2499 0,2053 0,1739 0,1481 0,1245 0,1106 - Aluminium Conductors ohms/km 1,4468 1,0492 0,7777 0,5423 0,3965 0,3183 0,2640 0,2166 0,1734 0,1472 - Copper Conductors A 100 120 150 185 220 250 280 320 365 410 - Aluminium Conductors A 80 95 120 145 175 200 225 255 295 335 - Dimensional Data Conductor Size (mm 2 ) 25 35 50 70 95 120 150 185 240 300 Diameter Cable Mass Over Serving Copper Conductors Aluminium Conductors Over Lead Sheath mm 35,14 37,60 37,67 40,68 43,51 45,71 48,32 51,40 56,54 60,53 - Steel Tape Armoured Served mm 48,65 51,11 51,18 54,19 57,02 59,22 61,83 64,91 70,05 74,04 - Single Wire Armoured Served mm 49,65 52,11 52,18 55,19 59,32 61,52 64,13 67,21 74,91 78,90 - Steel Tape Armoured Served kg/km 5880 6520 6995 8125 9365 10 360 11 750 13 325 16 070 18 570 - Single Wire Armoured Served kg/km 6205 6980 7495 8640 10 520 11 625 13 065 14 745 18 090 20 815 - Steel Tape Armoured Served kg/km 5400 5865 6080 6835 7610 8145 8960 9905 11 640 13 045 - Single Wire Armoured Served kg/km 5725 6325 6580 7350 8765 9410 10 270 11 325 13 660 15 290 - Lead times need to be confirmed at the time the order is placed. 74 2 VOLTEX CATALOGUE

TABLE 19: 6.35/11KV 3 CORE GENERAL PURPOSE SCREENED CABLES Fully impregnated armoured and served to SANS 97 Electrical Data Conductor Size (mm 2 ) 25 35 50 70 95 120 150 185 240 300 Product Code A.C Resistance Impedance Maximum Sustained Current Rating Ground Copper Conductors ohms/km 0,8700 0,6272 0,4634 0,3211 0,2315 0,1839 0,1494 0,1199 0,092 0,0742 - Aluminium Conductors ohms/km 1,4419 1,0430 0,7704 0,5325 0,3848 0,3045 0,2481 0,1978 0,1513 0,1215 - Copper Conductors ohms/km 0,8788 0,6382 0,4769 0,3381 0,2517 0,2073 0,1760 0,1503 0,1267 0,1129 - Aluminium Conductors ohms/km 1,4472 1,0497 0,7786 0,5429 0,3973 0,3191 0,2650 0,2176 0,1746 0,1484 - Copper Conductors A 115 140 160 200 240 270 305 340 390 440 - Aluminium Conductors A 90 105 125 155 185 210 235 270 305 345 - Dimensional Data Conductor Size (mm 2 ) 25 35 50 70 95 120 150 185 240 300 Product Code Diameter Cable Mass Over Serving Copper Conductors Aluminium Conductors Over Lead Sheath mm 32,79 35,05 37,73 38,20 41,02 43,21 45,84 48,90 53,35 58,06 - Steel Tape Armoured Served mm 45,50 48,56 51,24 51,71 54,53 56,72 59,35 62,41 66,86 71,57 - Single Wire Armoured Served mm 46,30 49,56 52,24 52,71 55,53 57,72 61,65 64,71 69,16 76,43 - Steel Tape Armoured Served kg/km 5070 6015 6665 7455 8670 9680 11 035 12 575 15 080 17 735 - Single Wire Armoured Served kg/km 5315 6345 7165 7940 9175 10 235 12 300 13 945 16 580 19 880 - Steel Tape Armoured Served kg/km 4595 5360 5770 6155 6920 7455 8245 9155 10 640 12 215 - Single Wire Armoured Served kg/km 4840 5690 6270 6640 7425 8940 9510 10 525 12 140 14 360 - Lead times need to be confirmed at the time the order is placed. VOLTEX CATALOGUE 75 3

CONTROL AND INSTRUMENTATION CABLES We supply an extensive range of instrumentation, control and telecommunication cables for the industrial market. These cables are used to provide voice and data services including measurement, sensing and control systems through the interconnection of equipment and instrumentation. Control cables are used in industrial power or control circuits for conveying electrical signals to associated equipment and instruments. These cables are suitable for installation in cable trays, conduit or trenches as well as other outdoor locations. A wide range of solid or stranded copper conductor, insulated with Polyethylene, Cross Linked Polyethylene (XLPE) or PVC in single or multi pair/multi triad and multicore industrial cables are available. These products are designed and manufactured according to specific or international standards. Cores are overall screened, whereas pairs can have screened over the laid-up pairs/triads (overall screened), or have screens around each individual pair or triad in combination with an overall screen (individually+overall screened) in order to minimise cross talk and ground loop interference. Aluminium/Polyester foil is used for screening, and Tinned Copper Braid is also available in certain constructions. Various sheathing and armouring designs are available, and include overall screening and armouring with Aluminium-Polyethylene-Laminate (APL) tape with Polyethylene as an outer sheath, or Steel Wire Armouring with PVC or Polyethylene as an outer sheath. A comprehensive range of sheathing material is available ranging from Polyethylene and PVC to Limiting Oxygen Index (LOI) materials and Low Smoke Zero Halogen (LSZH) options. For critical systems and applications a wide range of intrinsically safe industrial cable is available. 76 2 VOLTEX CATALOGUE

DEKARON (UNARMOURED) CABLE Control Cable - Overall Aluminium/Mylar Foil Screened - Cores Unarmoured Cable Construction Stranded annealed copper conductor, cross-linked Polyethylene (XLPE) insulated, the laid-up cores aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed. Core Identification: Black, white red and blue up to four core, thereafter white cores identified by black alphanumerical marking. Size Cores Nominal OD Minimum Bending Radius ± kg/km CCG A2 Gland Size Standard Drum Length Gross Drum Weight (mm²) (mm) (mm) (m) (kg) 300/500V 0,5 3 7,0 63 63 00-20ss 1000 112-0,5 4 7,8 70 77 00-20ss 1000 142 F1239 0,5 7 8,5 68 104 0-20s 1000 183-0,5 12 10,9 87 160 0-20s 1000 252 F3180 0,5 19 12,7 101 228 1-20 1000 347-0,5 24 15,1 120 305 2-25 500 235-0,5 27 15,9 127 336 2-25 500 248-600/1000V 1,0 3 7,8 71 86 00-20ss 1000 151 F1174 1,0 4 8,7 79 109 0-20s 1000 353 F1175 1,0 7 10,6 96 172 0-20s 1000 240 F1176 1,0 12 14,1 127 266 1-20 500 199 F1177 1,0 19 16,3 147 399 2-25 500 264 F1178 1,0 24 19,3 174 489 2-25 500 331-1,0 27 19,7 178 541 2-25 500 353 F1179 600/1000V 1,5 3 8,7 79 108 0-20s 1000 173 F1180 1,5 4 10,1 91 145 0-20s 1000 210 F1181 1,5 7 11,9 107 205 1-20 500 168 F1182 1,5 12 15,8 143 337 2-25 500 244 F3127 1,5 19 18,3 165 484 2-25 500 313 F3128 1,5 24 21,8 196 622 3-32 500 473 F3129 1,5 27 22,3 201 681 3-32 500 503 F3130 Items above with (-) in the codes column are available on special request. The above cable is also available in alternative constructions such as low - halogenated (black outer sheath with blue stripe) and zero - halogenated (black outer sheath with white stripe) flame retardant cable. This type of cable is generally referred to as "Dekaron" unarmoured cable. The "Dekaron" range of cable does however also include galvanised single wire armoured (SWA) and Aluminium-Polyethylene-Laminate (APL) armoured cables, which are also available in pairs and triad (trip) constructions. Lead times need to be confirmed at the time the order is placed. Dekaron is a Furon trademark. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 77 3

DEKARON (ARMOURED) CABLE Control Cable - Overall Aluminium/Mylar Foil Screened - Cores Steel Wire Armoured Cable construction Stranded annealed copper conductor, XLPE insulated, the laid-up cores aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed, galvanised single wire armoured, flame retardant PVC sheathed. Core Identification: Black, white red and blue up to four core, thereafter white cores identified by black alphanumerical numbering. Voltage Rating : - 0.5mm² = 300/500V, 1.0 And 1.5mm² = 600/1000 Size Cores Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) 300/500V 0,5 3 11,9 120 318 0-20s 1000 393-0,5 4 12,7 127 346 0-20s 1000 421-0,5 7 14,4 144 438 0-20 1000 946-0,5 12 17,0 170 572 0-20 1000 734-0,5 19 19,6 197 749 1-25 1000 895-0,5 24 21,9 219 873 1-25 1000 599-0,5 27 22,2 223 912 2-25 500 618-600/1000V 1,0 3 12,7 128 366 0-20s 1000 441-1,0 4 13,6 136 409 0-20s 1000 496-1,0 7 15,5 156 521 0-20s 1000 608-1,0 12 19,4 194 744 1-20 500 534 F3174 1,0 19 21,6 216 921 2-25 500 623-1,0 24 25,3 254 1 280 2-25 500 884-1,0 27 25,7 258 1 343 2-25 500 916-600/1000V 1,5 3 13,6 137 414 0-20s 1000 501-1,5 4 15,0 150 482 0-20s 1000 569-1,5 7 16,8 168 601 0-20 500 376-1,5 12 21,1 211 869 2-25 500 597-1,5 19 24,3 244 1256 2-25 500 790-1,5 24 27,8 278 1522 3-32 500 1005-1,5 27 28,7 287 1617 3-32 500 1053 - Items above with (-) in the codes column are available on special request. The above cable is also available in alternative constructions such as low - halogenated (black outer sheath with blue stripe) and zero - halogenated (black outer sheath with white stripe) flame retardant cable. This type of cable is generally referred to as "Dekaron" unarmoured cable. The "Dekaron" range of cable does however also include galvanised single wire armoured (SWA) and Aluminium-Polyethylene-Laminate (APL) armoured cables, which are also available in pairs and triad (trip) constructions. Screens can be either overall aluminium/mylar foil or individual and overall aluminium/mylar foil, and a tinned stranded copper drain wire is always included for each foil screen. Lead times need to be confirmed at the time the order is placed. Dekaron is a Furon trademark. Mylar (clear polyester) is a Du Pont trademark. 78 2 VOLTEX CATALOGUE

DEKARON (APL ARMOURED) CABLE Control Cable - Overall Aluminium/Mylar Foil Screened - Cores Aluminium - Polyethylene - Laminate (APL) Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads individually and overall aluminium/mylar foil screened, each foil screen with tinned stranded copper drain wire, flame retardant PVC sheathed, Aluminium-Polyethylene-Laminate (APL) armoured. Core Identification: White Cores, alphanumerically numbered. Voltage Rating : - 0.5mm² = 300/500V, 1.0 and 1.5mm² = 600/1000V Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG A2 Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) 300/500V 0,5 3 10,8 98 118 0-20s 1000 193-0,5 4 11,5 104 136 1-20 1000 211 F1222 0,5 7 13,2 120 185 1-20 1000 272-0,5 12 15,8 143 259 1-20 1000 346-0,5 19 18,5 167 366 2-25 1000 512-0,5 24 20,8 187 436 2-25 or 3-32 500 305-0,5 27 21,1 190 464 3-32 500 394-600/1000V 1,0 3 11,6 105 145 1-20 1000 220 F1170 1,0 4 12,5 113 169 1-20 1000 244 F1225 1,0 7 14,4 130 239 1-20 1000 326 F1172 1,0 12 18,3 165 370 2-25 500 256 F1173 1,0 19 20,5 185 494 2-25 or 3-32 500 334 F2896 1,0 24 23,5 212 619 3-32 500 472 F3082 1,0 27 23,9 216 665 3-32 500 495 F3083 600/1000V 1,5 3 12,5 113 179 1-20 1000 254 F3119 1,5 4 13,9 125 217 1-20 1000 304 F3120 1,5 7 15,6 141 284 2-25 500 217 F3121 1,5 12 20,0 180 449 2-25 500 312 F3122 1,5 19 22,5 203 611 3-32 500 468 F3123 1,5 24 26,0 234 769 3-32 500 531 F3124 1,5 27 26,4 238 829 4-32 902 561 F3125 Items above with (-) in the codes column are available on special request. The "Dekaron" range of cable does however also include galvanised single wire armoured (SWA) and Aluminium-Polyethylene-Laminate (APL) armoured cables, which are also available in pairs and triad (trip) constructions. Screens can be either overall aluminium/mylar foil or individual and overall aluminium/mylar foil, and a tinned stranded copper drain wire is always included for each foil screen. Lead times need to be confirmed at the time the order is placed. Dekaron is a Furon trademark. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 79 3

PAIRS AND TRIADS OAM UNARMOURED Instrument Cable - Overall Aluminium/Mylar Foil Screened - Pairs And Triads Unarmoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating : 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG A2 Gland Size Standard Drum Length Gross Drum Weight (mm²) (mm) (mm) (m) (kg) Pairs 0,5 1 5,6 51 42 00-16ss 1000 91 F1237 0,5 2 8,9 81 88 0-20s 1000 153 F1238 0,5 4 10,6 96 128 0-20s 1000 203 F1239 0,5 8 13,3 121 212 1-20 1000 299 F1240 0,5 12 15,8 143 282 2-25 500 216-0,5 16 17,5 158 350 2-25 500 250-0,5 24 20,3 183 491 2-25 500 333-0,5 32 22,9 207 620 3-32 500 472-0,5 36 24,8 224 710 3-32 500 375-1,0 1 6,4 58 60 00-20ss 1000 109 F1241 1,0 2 10,8 98 131 0-20s 1000 206 F1242 1,0 4 12,4 112 183 1-20 1000 258 F1243 1,0 8 16,1 146 315 2-25 1000 477 F1244 1,0 12 18,7 169 428 2-25 500 285 F1245 1,0 16 21,1 190 562 3-32 500 368-1,0 24 24,1 217 772 3-32 300 394-1,5 1 7,2 66 73 00-20ss 1000 138 F1246 1,5 2 12,4 112 166 1-20ss 1000 241 F1247 1,5 4 14,7 132 247 1-20 or 2-25 1000 334 F1248 1,5 8 18,6 168 407 2-25 500 275 F1249 1,5 12 22,1 199 582 3-32 500 453-1,5 16 24,9 224 760 3-32 300 390 F2812 1,5 24 28,4 256 1050 4-40 300 477 - Triads 0,5 1 5,9 54 51 00-16ss 1000 100 F1252 0,5 4 11,8 107 164 1-20 1000 239-0,5 8 15,7 141 280 2-25 1000 367-0,5 12 18,8 169 383 2-25 500 263-0,5 16 21,2 191 502 3-32 500 413-0,5 24 26,5 239 726 3-32 300 380-0,5 36 30,6 273 999 4-40 300 462-1,0 1 6,8 61 72 00-20ss 1000 121 F1253 1,0 4 14,3 129 255 1-20 1000 342-1,0 8 18,3 167 428 2-25 500 285-1,0 12 22,5 205 620 3-32 500 472-1,0 16 25,4 229 809 3-32 300 405-1,5 1 7,7 69 90 00-20ss 1000 155 F1254 1,5 4 16,4 148 325 2-25 1000 487-1,5 8 21,8 197 580 2-25 500 452-1,5 12 26,8 241 841 3-32 or 4-40 300 414 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. 80 2 VOLTEX CATALOGUE

PAIRS AND TRIADS IOAM UNARMOURED Instrument Cable - Individually And Overall Aluminium/Mylar Foil Screened- Pairs And Triads - Unarmoured Cable Construction Stranded annealed copper conductor, XLPE Insulated, the laid-up pairs/triads individually and overall aluminium/ Mylar foil screened, each foil screen with tinned stranded copper drain wire, flame retardant PVC sheathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 2 9,7 87 109 0-20s 1000 174 F1211 0,5 4 11,0 99 159 0-20s 1000 234-0,5 8 14,3 130 273 1-20 1000 348-0,5 12 16,9 152 347 2-25 500 249-0,5 16 19,4 175 458 2-25 500 316 F3318 0,5 24 22,9 207 627 3-32 500 478-0,5 32 26,1 235 824 3-32 500 558-0,5 36 27,6 249 907 4-40 500 698-1,0 2 11,1 101 148 1-20 1000 223 F1212 1,0 4 12,8 115 213 1-20 1000 288 F1214 1,0 8 16,7 151 377 2-25 1000 539 F1215 1,0 12 20,2 182 544 2-25 500 359 F1216 1,0 16 22,9 206 691 3-32 500 508 F1217 1,0 24 27,4 247 998 4-40 500 743-1,5 2 12,7 115 183 1-20 1000 258 F1218 1,5 4 15,0 136 297 2-25 1000 384 F1219 1,5 8 19,7 178 494 2-25 500 334 F2893 1,5 12 23,3 210 685 3-32 500 505-1,5 16 26,8 242 903 4-40 300 433-1,5 24 32,2 290 1305 4-40 300 554 - Triads 0,5 4 12,2 110 189 1-20 1000 264-0,5 8 16,2 146 330 2-25 1000 492-0,5 12 19,8 179 479 2-25 500 327-0,5 16 22,0 198 599 3-32 500 462 F3320 0,5 24 27,5 248 872 4-40 300 424-0,5 36 32,1 286 1248 4-40 300 536-1,0 4 14,7 132 286 2-25 1000 373-1,0 8 19,2 175 509 2-25 500 342 F2813 1,0 12 23,3 210 712 3-32 500 518-1,0 16 26,1 237 931 3-32 300 441-1,5 4 16,8 152 348 2-25 1000 510-1,5 8 22,3 202 645 3-32 500 485-1,5 12 27,4 247 929 4-40 300 441 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 81 3

PAIRS AND TRIADS OAM SWA Instrument Cable - Overall Aluminium/Mylar Foil Screened - Pairs/Triads Steel Wire Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed, flame retardant PVC bedding sheathed, single wire armoured (SWA), flame retardant PVC outer sheathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 1 10,5 106 249 0-20s 1000 324-0,5 2 13,8 139 394 0-20s 1000 481-0,5 4 15,5 155 486 0-20s 1000 573-0,5 8 18,6 187 651 1-20 1000 797-0,5 12 21,1 212 810 2-25 500 567-0,5 16 22,8 228 930 2-25 500 627-0,5 24 26,3 263 1323 2-25 500 906-0,5 32 29,3 294 1589 3-32 500 1039-0,5 36 32,0 320 1903 3-32 300 733-1,0 1 11,3 114 290 0-20s 1000 365 F1233 1,0 2 15,7 158 489 0-20s 1000 576 F1234 1,0 4 17,3 174 589 1-20 1000 751-1,0 8 21,4 215 857 2-25 1000 1003-1,0 12 24,7 247 1199 2-25 500 762-1,0 16 27,1 271 1418 3-32 500 953-1,0 24 31,3 313 1986 3-32 300 758-1,5 1 12,1 122 329 0-20s 1000 404 F1235 1,5 2 17,3 173 572 1-20 1000 734 F1236 1,5 4 20,0 200 738 2-25 1000 884-1,5 8 24,6 247 1177 2-25 500 751-1,5 12 28,5 285 1510 3-32 500 999-1,5 16 32,1 321 2009 3-32 300 765-1,5 24 35,6 357 2448 4-40 300 978 - Triads 0,5 1 10,8 109 269 0-20s 1000 344-0,5 4 16,7 168 557 1-20 1000 719-0,5 8 21,0 210 808 2-25 1000 954-0,5 12 24,8 248 1150 2-25 500 737-0,5 16 27,2 272 1371 3-32 500 930-0,5 24 33,7 337 2041 4-40 300 856-0,5 36 37,8 375 2499 4-40 300 994-1,0 1 11,7 117 316 0-20s 1000 391-1,0 4 19,6 196 733 2-25 1000 820-1,0 8 24,3 245 1179 2-25 500 752-1,0 12 28,9 291 1565 3-32 500 1027-1,0 16 32,6 326 2086 3-32 300 788-1,5 1 12,6 126 358 0-20s 1000 433-1,5 4 21,7 218 868 2-25 1000 1014-1,5 8 28,2 283 1505 3-32 500 997-1,5 12 34,0 340 2166 4-40 300 894 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. 82 2 VOLTEX CATALOGUE

PAIRS AND TRIADS IOAM SWA Instrument Cable - Individually And Overall Aluminium/Mylar Foil Screened Pairs And Triads - Steel Wire Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads individually and overall aluminium/ Mylar foil screened, each foil screen with tinned stranded copper drain wire, flame retardant PVC s heathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 2 14,6 146,0 439 0-20s 1000 526 F3146 0,5 4 15,9 159,0 527 0-20s 1000 614 F3147 0,5 8 19,6 197,0 761 2-25 1000 907 F3148 0,5 12 22,2 222,0 902 2-25 500 613 F3149 0,5 16 25,4 255,0 1267 2-25 500 878 F3150 0,5 24 29,3 293,0 1597 3-32 500 1043 F3152 0,5 32 33,3 334,0 2114 3-32 or 4-40 500 878-0,5 36 34,8 349,0 2268 4-40 300 924-1,0 2 16,0 161,0 517 0-20s or 1-20 1000 679 F1206 1,0 4 18,1 181,0 651 1-20 1000 797 F1207 1,0 8 21,4 215,0 934 2-25 1000 1080 F1208 1,0 12 26,2 262,0 1376 2-25 500 932 F1209 1,0 16 29,3 293,0 1644 3-32 500 1066 F3153 1,0 24 34,6 347,0 2356 4-40 300 951 F3155 1,5 2 18,0 180,0 620 1-20 1000 782 F1210 1,5 4 20,3 204,0 784 2-25 1000 930 F3156 1,5 8 25,7 257,0 1305 2-25 500 897 F2892 1,5 12 30,5 305,0 1863 3-32 500 1176 F2891 1,5 16 33,3 334,0 2228 4-40 300 912 F3157 1,5 24 39,8 339,0 2928 4-40 300 1170 F3159 Triads 0,5 4 17,1 172,0 594 1-20 1000 669-0,5 8 21,5 215,0 870 2-25 1000 1016-0,5 12 25,8 259,0 1292 2-25 500 890-0,5 16 28,4 284,0 1526 3-32 500 1025-0,5 24 34,7 347,0 2231 4-40 300 914-0,5 36 39,7 394,0 2838 4-40 300 1143-1,0 4 20,0 200,0 777 2-25 1000 923-1,0 8 25,2 254,0 1301 2-25 500 894-1,0 12 30,5 306,0 1892 3-32 500 1190-1,0 16 33,5 336,0 2250 4-40 300 919-1,5 4 22,1 221,0 911 2-25 1000 1155-1,5 8 28,7 288,0 1586 3-32 500 1037-1,5 12 34,6 347,0 2288 4-40 300 930 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 83 3

PAIRS AND TRIADS OAM APL POLY Instrument Cable - Overall Aluminium/Mylar Foil Screened - Pairs/Triads Aluminium - Polyethylene - Laminate (Apl) Armoured Cable Construction Stranded annealed copper conductor, XLPE Insulated, the laid-up pairs/triads aluminium/mylar Foil screened, tinned stranded copper drain wire, flame retardpant PVC bedding sheathed, Aluminium- Polyethylene-Laminate (APL) armoured. Core Identification: Black and white alpha numerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 1 9,4 85,0 90,0 0-20s 1000 155 F1220 0,5 2 12,7 115,0 153,0 1-20 1000 228 F1221 0,5 4 14,4 130,0 203,0 1-20 1000 290 F1222 0,5 8 17,1 155,0 287,0 2-25 1000 449 F3189 0,5 12 20,0 181,0 394,0 2-25 500 284 F3190 0,5 16 21,7 195,0 471,0 3-32 500 398 F3191 0,5 24 24,5 221,0 629,0 3-32 500 477-0,5 36 29,4 265,0 772,0 4-40 300 429-1,0 1 10,2 92,0 111,0 0-20s 100i 186 F1223 1,0 2 14,6 132,0 205,0 2-25 1000 292 F1224 1,0 4 16,2 146,0 265,0 2-25 1000 427 F1225 1,0 8 20,3 183,0 428,0 2-25 1000 590 F1226 1,0 12 22,9 206,0 557,0 3-32 500 441 F1227 1,0 16 25,3 228,0 706,0 3-32 500 499 F1228 1,0 24 28,5 258,0 949,0 4-40 300 447-1,5 1 11,0 100,0 128,0 0-20s 1000 203 F1229 1,5 2 16,2 146,0 248,0 2-25 1000 410 F1230 1,5 4 18,4 166,0 354,0 2-25 1000 500 F1231 1,5 8 22,8 206,0 535,0 3-32 500 430 F1232 1,5 12 26,3 237,0 730,0 3-32 500 511-1,5 16 29,4 265,0 943,0 4-40 300 445-1,5 24 33,0 297,0 1256,0 4-40 300 539 - Triads 0,5 1 9,7 88,0 100,0 0-20s 1000 165-0,5 4 15,6 141,0 244,0 2-25 1000 331-0,5 8 19,8 179,0 392,0 2-25 1000 538-0,5 12 23,0 207,0 512,0 3-32 500 418-0,5 16 25,4 229,0 646,0 3-32 500 469-0,5 24 31,1 280,0 919,0 4-40 300 438-0,5 36 35,2 314,0 1217,0 5-50 300 609-1,0 1 10,5 95,0 126,0 0-20s 1000 201 F1250 1,0 4 18,4 166,0 357,0 2-25 1000 503-1,0 8 22,5 204,0 554,0 3-32 500 439-1,0 12 26,7 242,0 773,0 4-40 500 533-1,0 16 30,0 270,0 990,0 4-40 300 459-1,5 1 11,4 103,0 148,0 1-20 1000 223 F1251 1,5 4 20,6 186,0 442,0 2-25 or 3-32 1000 588-1,5 8 26,0 234,0 726,0 3-32 500 509-1,5 12 31,4 283,0 1036,0 4-40 300 473 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. 84 2 VOLTEX CATALOGUE

PAIRS AND TRIADS IOAM APL POLY Instrument Cable - Individually And Overall Aluminium/Mylar Foil Screened - Pairs/Triads Aluminium - Polyethylene - Laminate (Apl) Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads individually and overall aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed, Aluminium-Polyethylene-Laminate (APL) armoured. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 2 13,4 121 177 1-20 1000 264 F1197 0,5 4 14,8 133 234 2-25 1000 321 F1198 0,5 8 18,5 167 378 2-25 1000 524 F3132 0,5 12 20,7 187 465 2-25 or 3-32 500 320 F3133 0,5 16 23,6 213 591 3-32 500 458 F3134 0,5 24 27,1 244 781 4-40 500 537 F3136 0,5 32 30,7 277 1016 4-40 500 752-0,5 36 32,2 290 1070 4-40 300 498 F3137 1,0 2 14,9 135 224 2-25 1000 311 F1199 1,0 4 16,5 149 297 2-25 1000 459 F1200 1,0 8 20,9 189 496 3-32 1000 642 F1201 1,0 12 24,4 220 682 3-32 500 503 F1202 1,0 16 27,0 244 845 4-40 500 569 F1203 1,0 24 32,0 289 1196 4-40 300 603 F1204 1,5 2 16,5 149 267 2-25 1000 429 F1205 1,5 4 19,2 173 388 2-25 1000 534 F3140 1,5 8 23,9 215 627 3-32 500 476 F3141 1,5 12 27,5 248 839 4-40 500 664 F3142 1,5 16 31,4 283 1099 4-40 300 492 F3143 1,5 24 36,8 332 1534 5-50 300 704 F3145 Triads 0,5 4 16,0 144 271 2-25 1000 358-0,5 8 20,4 184 444 2-25 1000 590-0,5 12 24,0 217 614 3-32 500 469-0,5 16 26,1 236 747 3-32 500 520-0,5 24 32,0 289 1070 4-40 300 483-0,5 36 36,7 328 1474 5-50 300 686-1,0 4 18,8 170 393 2-25 1000 539-1,0 8 23,4 213 641 3-32 500 483-1,0 12 27,5 248 868 4-40 500 678-1,0 16 30,7 278 1126 4-40 300 500-1,5 4 21,0 189 472 3-32 1000 618-1,5 8 26,5 239 787 3-32 500 540-1,5 12 32,0 289 1126 4-40 300 500 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 85 3

PAIRS OAM DEF SPEC Pvc Insulated Overall Aluminium/Mylar Foil Screened Pairs, Colour Coded To Def. Stan 61-12 Cable Construction Tinned stranded annealed copper conductor, PVC insulated (150/250V), aluminium/mylar foil screened, tinned stranded copper drain wire, PVC sheathed (Grey). Size Pairs Nominal OD ± kg/km Packing Core Identification CCG A2 Gland Size Product Code (mm 2 ) (mm) (m) 0,22 2 6,2 51 1000 DEF STAN 61-12 00-20ss F1184 0,22 3 6,5 62 1000 DEF STAN 61-12 00-20ss F2653 0,22 4 7,2 76 1000 DEF STAN 61-12 00-20ss F1185 0,22 6 8,1 108 1000 DEF STAN 61-12 00-20ss or 1-20 F2654 0,22 8 9,2 122 1000 DEF STAN 61-12 0-20s F2655 0,22 12 11,6 179 1000 DEF STAN 61-12 1-20 F2656 0,22 18 13,4 242 500 DEF STAN 61-12 1-20 - 0,22 25 15,4 323 500 DEF STAN 61-12 2-25 - 0,22 30 16,4 355 500 DEF STAN 61-12 2-25 - 0,22 36 18,3 408 500 DEF STAN 61-12 2-25 - 0,22 50 20,3 518 500 DEF STAN 61-12 2-25 - 0,50 1 5,1 56 1000 DEF STAN 61-12 00-16ss F1186 0,50 2 7,6 76 1000 DEF STAN 61-12 00-20ss F1187 0,50 3 8,1 105 1000 DEF STAN 61-12 00-20ss - 0,50 4 8,6 119 1000 DEF STAN 61-12 0-20s F1188 0,50 6 11,2 160 1000 DEF STAN 61-12 0-20s or 1-20 F1189 0,50 8 12,2 205 1000 DEF STAN 61-12 1-20 F1190 0,50 12 15,2 271 1000 DEF STAN 61-12 2-25 F1191 0,50 18 18,8 381 500 DEF STAN 61-12 2-25 - 0,50 20 21,3 418 500 DEF STAN 61-12 3-32 - 0,50 25 22,3 497 500 DEF STAN 61-12 3-32 - Pair DEF STAN 61-12 COLOUR CODING 1 (Red, blue) 2 (Red, blue), (green, yellow) 4 (Red, blue), (green, yellow), (white, black), (brown, violet) 6 (Red, blue), (green, yellow), (white, black), (brown, violet), (orange, pink), (turquoise, grey), (red/blue - green/red) 8 12 16 20 25 (Red, blue), (green, yellow), (white, black), (brown, violet), (orange, pink), (turquoise, grey), (Red/blue - green/red), (yellow/red - white/red) (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue -- green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green) (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue -- green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green), (orange/green - grey/green), (Red/brown - yellow/brown), (white/brown - grey/brown), (green/black - violet/black), (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue -- green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green), (orange/green - grey/green), (Red/brown - yellow/brown), (white/brown - grey/brown), (green/black - violet/black), (Red/black - brown/black), (yellow/violet - white/violet), (red, yellow), (green, black) (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue - green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green), (orange/green - grey/green), (Red/brown - yellow/brown), (white/brown - grey/brown), (green/black - violet/black), (Red/black - brown/black), (yellow/violet - white/violet), (red, yellow), (green, black), (White, violet), (brown, pink), (orange, grey), (turquoise, blue), (red, black) Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Also available in individual and overall aluminium/polyester foil screened construction. Mylar (clear polyester) is a Du Pont trademark. 86 2 VOLTEX CATALOGUE

CAT 5E SOLID UNSHIELDED TWISTED PAIR (UTP) CABLE Cable Construction 24 American wire guage (AWG) (1/0.51mm) solid plain annealed copper conductor polyolefin insulated, 4 colour coded twisted pairs laid - up and PVC sheathed. Temperature Range 0 C to +50 C (installation) and -20 C to +70 C (installed). Compliance This cable is EC verified and complies with: ISO 11801, TIA/EIA 568a and EN 50173. DC Resistance Resistance Electrical Characteristics (Standards) at 20 C Mutual Capacitance Capacitance Skew Velocity of Propagation Ω/km Maximum % nf/km Maximum pf/km Maximum nsec/km Maximum (VOP) Characteristic Impedance Ω (±15%) at 1.0 to 100 Mhz 93,8 2 56 1000 450 0.68c 100 Electrical Characteristics (Standards) for CAT 5E Frequency Attenuation Near End Cross Talk (NEXT) Power Sum Near End Cross Talk (PSNEXT) Power Sum Equal Level Far End Cross Talk (PSELFEXT) MHz db/100m db db db 1 2,1 65,3 62,3 60,8 4 4,3 56,3 53,3 48,7 10 6,6 50,3 47,3 40,8 16 8,2 47,3 44,3 36,7 20 9,2 45,8 42,8 34,7 31 11,8 42,9 39,9 30,9 63 17,1 38,4 35,4 24,8 100 22,0 35,3 32,3 20,8 Size Pairs Nominal OD Cable Weight (mm 2 ) (mm) (kg/km) Total Weight/ 500m Drum Per 305m Box Fire Safety Compliance 0,2044 4 5,0 34 17.8/10.3 IEC 332-1 Standard Packing 305m easy-pull box or 500m plastic reel F1166 Available in the following coding colours: Pair 1 Pair 2 Pair 3 Pair 4 : Blue/white with blue stripe. : Orange/white with orange stripe. : Green/white with green stripe. : Please see image above. Kindly enquire about our other communication cables such as CAT 6. Lead times need to be confirmed at the time the order is placed. VOLTEX CATALOGUE 87 3

OUTDOOR TELEPHONE CABLE Galvanised Wire Armoured Cable Construction Solid annealed copper conductor, PVC insulated, PVC bedding sheathed, galvanised wire armoured, PVC sheathed outdoor telephone cable to Telkom specification 268/271 W/A. Size Pairs Nominal OD Cable Weight Total Weight/ 1000m Drum Maximum Conductor Loop Resistance Minimum Insulation Resistance (mm 2 ) (mm) (kg/100 m) (Ω/km) (MΩ-km) 0,6 2 9,5 21,4 278 129,4 37,5 F2670 0,6 4 11,5 28,9 353 129,4 37,5 F2671 0,6 5 12,0 31,5 380 129,4 37,5 F2672 0,6 6 12,5 34,9 414 129,4 37,5 F2673 0,6 10 14,0 41,1 476 129,4 37,5 F1596 0,6 15 15,5 51,2 635 129,4 37,5 F2674 0,6 20 16,5 58,1 662 129,4 37,5 F2675 0,6 30 18,0 67,2 730 129,4 37,5 F2677 0,6 40 20,0 85,8 553 129,4 37,5 F2678 0,6 51 24,0 124,0 852 129,4 37,5-0,6 76 26,5 160,0 900 129,4 37,5-0,6 100 31,0 206,2 1263 129,4 37,5 F2681 0,9 4 13,0 36,9 450,0 55,8 37,5 F2683 0,9 5 14,0 42,0 485,0 55,8 37,5 F2684 0,9 6 14,5 46,1 543,0 55,8 37,5 F2685 0,9 10 16,0 57,9 661,0 55,8 37,5 F2686 0,9 15 18,5 74,2 453,0 55,8 37,5 F2687 0,9 20 19,5 86,4 514,0 55,8 37,5 F2688 0,9 30 24,5 136,3 805,0 55,8 37,5 F2690 0,9 40 26,5 160,2 970,0 55,8 37,5 F2691 0,9 51 29,5 192,3 1194,0 55,8 37,5-0,9 76 35,0 273,5 1597,0 55,8 37,5 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. INDOOR TELEPHONE CABLE Cable Construction Solid Annealed Copper Conductor (plain or tinned), PVC insulated, white PVC Sheathed indoor telephone cable to Telkom spec 268/271. Size Pairs Nominal OD Cable weight Total Weight/ 1000m Drum Maximum Conductor Loop Resistance Minimum Insulation Resistance (mm) (mm) (kg/m) (Ω/km) (MΩ-km) 0,5 2 3,8 2 49 186,4 37,5 F1597 0,5 3 5,1 3 96 186,4 37,5 F2658 0,5 4 5,6 4 67 186,4 37,5 F2659 0,5 5 5,8 4 109 186,4 37,5 F2660 0,5 6 6,8 5 117 186,4 37,5 F2661 0,5 10 8,4 9 146 186,4 37,5 F1598 0,5 15 9,7 11 178 186,4 37,5 F2662 0,5 20 10,7 15 213 186,4 37,5 F2663 0,5 25 11,4 18 243 186,4 37,5 F2664 0,5 30 11,7 21 291 186,4 37,5 F2665 0,5 40 14,2 27 358 186,4 37,5 F2666 0,5 50 16,0 35 429 186,4 37,5 F2667 0,5 75 18,0 51 570 186,4 37,5 F2668 0,5 100 22,8 69 752 186,4 37,5 F2669 Lead times need to be confirmed at the time the order is placed. Above codes refer to plain configuraiton. 88 2 VOLTEX CATALOGUE