UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Similar documents
IFC 010 Signal Converter

Electromagnetic flowmeters and switches DWM 1000/2000

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

BATCHFLUX and BATCHCONTROL

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

OPTISONIC 7300 Technical Datasheet

OPTISONIC 6300 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

IFC 050 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet

IFC 100 Technical Datasheet

WATERFLUX 3070 Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet

IFC 050 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

OPTISONIC 7300 Technical Datasheet

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

OPTIMASS 1000 Technical Datasheet

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

IFC 050 Technical Datasheet

WATERFLUX 3000 Quick Start

OPTISONIC 6300 P Technical Datasheet

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

WATERFLUX 3000 Quick Start

IFC 100 Technical Datasheet

OPTISONIC 3400 Technical Datasheet

2-Wire. Level Gauge BM 702

Design and applications

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

Technical specification FLUXUS F401 H2O

Electromagnetic Flow Transmitter

KFS. Flap-type flow meter. Design and range of application

Technical Information Proline Promag 10P

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

FLOMID FX Electromagnetic Flowmeter

Technical Specification FLUXUS ADM 8127B

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Model Sono-Trak Transit Time

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Ambient Conditions. Operating Conditions. Pressure

MFC 400 Technical Datasheet

OPTISONIC 4400 Technical Datasheet

UTM10 Series Ultrasonic Transit-time Flowmeters

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Proline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications

TMU. Coriolis Mass Flow Meter. for liquids and gas

MFC 400 Technical Datasheet

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

MFC 400 Technical Datasheet

Advanced instrumentation solutions crafted with highest precision

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

Coriolis Massflowmeter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Electro-Magnetic Flowmeters COPA-XE

HTTF Transit Time Ultrasonic Flow Meter

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

OPTISONIC 6300 Quick Start

Dosimass. Technical Information. Coriolis Mass Flow Measuring System For filling applications

Technical Specification FLUXUS ADM 8x27

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Coriolis Mass Flow Meter Model TM

Proline Promass 40E. Technical Information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

Technical specification FLUXUS WD

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Flow Measurement SITRANS F US Inline

TZIF 4. Current-to-Pulse Converter 10/ EN

Clamp-on ultrasonic flowmeters have six product families: max. 2% solids

Applications Features

IFC 300 Technical Datasheet

MFC 300 Technical Datasheet

INSERTION paddle wheel flowmeter for continuous flow measurement

Technical Information Proline Promag 55S

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

ULTRASONIC FLOW METER FT101

Coriolis Massflowmeter

Digital batch controller

INLINE flowmeter for continuous flow measurement

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

RCM DIRECT READING FLOWMETER

OPTIFLUX 1000 Handbook

OPTITEMP TT 20 Technical Datasheet

Vortex Flow Measuring System prowirl 77

Proline Promag 55S. Technical Information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Coriolis Mass Flow Measuring System promass 40 E

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

Digital flow transmitter for continuous flow measurement

IFC 100 / IFC 300. Electromagnetic flow converters for the OPTIFLUX series

Type CP-S, CP-C & CP-A Switch mode

Transcription:

KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments Communications engineering Engineering systems & solutions

, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Efficient flow measurement and volume counting of all types of water and wastewater in closed pipelines or in open channels and raceways. Advantages No constriction of the pipe cross-section No additional pressure drop Electrical conductivity, pressure, density, etc. have no effect on measurements Easy to install from the outside or the inside No maintenance requirement Low power consumption Low operating costs Ultrasonic flowmeters with UFS 800 W sensors for measuring the volumetric flowrate in metal pipelines. The sensors are welded to the outside of the pipelines. Ultrasonic flowmeter with UFS 800 C sensors for measuring flow velocity in open channels. The sensors can be installed or mounted from the inside or outside of the channel. UFC 500 F signal converter Digital signal processing Easy to operate Current, pulse and status outputs Low power consumption Large clear text LC display, easy to read 2

Calibration Installation notes UFM 800 Systems Versions Sensors Single-beam measurement Double-beam measurement Signal converter Hazardous-duty version Application/Measurement Accuracies Measurement Linearity Repeatability for measuring process liquids in metal pipelines DN 500 5000 / 20 200 2 x UFS 800 W 4 x UFS 800 W (option) UFC 500 pending Volumetric flowrate Volume counts Direction of flow Transit time measurement typical values, dependent upon application ± 3% of measured value ± 0.5% of measured value (v > 0.5 m/s or > 1.6 ft/s) ± 0.2% of measured value for measuring process liquids in open channels Width: 400 8000 mm 2 x UFS 800 C UFC 500 / M 4.1 Flow velocity Direction of flow typical values, dependent upon application ± 5% of measured value ± 0.5% of measured value ± 0.2% of measured value Background Flowtubes UFM 500 Clamp-on UFM 600/610 Weld-om Open channel Dimensions and weights Dimensions in mm and (inch) Gasflowtube GFM 700 UFC 500 F signal converters Weight: approx. 4.2 kg (9.3 lb) Ø 122 (4.80 ) 208 (8.19 ) Custody transfer ALTOSONIC V UFS 800 W sensors UFS 800 C sensors Sizing guide Ordering guide / 3

UFM 800 Responsibility for suitability and intended use of our instruments rests solely with the purchaser. Technical data Sensors UFS 800 W UFS 800 C Versions Single-beam measurement Double-beam measurement Hazardous-duty version to European Standard Application data Mounting location Sensor alignment Operating data Process temperature Pressure Ambient temperature Storage temperature (electronics) (electronics) Protection category (IEC529/EN 60529) Standard Optional Material Sensor Sensor mount 2 x FS 500 W 4 x FS 500 W (option) replaceable at operating pressure Ex de ib, pending on metal pipelines meter size DN 500 5000 / 20 200 DN 1000 / 40 acoustic alignment (water only) DN > 1000 / > 40 by KROHNE technicians using laser alignment set 50 to +170 C / 58 to +338 F max. 40 bar / max. 580 psig 25 to +60 C / 13 to +140 F 40 to +60 C / 40 to +140 F (IEC529/EN 60529) IP 65 equivalent to NEMA 12 and 13 IP 67, IP 68 equivalent to NEMA 6 stainless steel 1.4404 equivalent to SS 316 L stainless steel 1.4301 equivalent to SS 304 others on request 2 x FS 500 C Installation in open channels, Mounted from the outside or the inside Width: 400 8000 mm / 16 320 by KROHNE technicians with laser alignment set 25 to +120 C / 13 to +248 F max. 10 bar / max. 150 psig 25 to +60 C / 13 to +140 F 40 to +60 C / 40 to +140 F IP 65 equivalent to NEMA 12 and 13 IP 67, IP 68 equivalent to NEMA 6 stainless steel 1.4301 or SS 304, Pyrex and Viton stainless steel 1.4301 or SS 304 and Viton others on request 4 /

UFM 800 UFC 500 F Signal converters Versions Standard Option Hazardous- duty version Full-scale range Volumetric flowrate Q 100% Setting range 355 1250000 m 3 /hr 1560 5500000 US gal/min Units any Current output Function UFC 500 F UFC 500 F / MP, settable via magnetic sensors and bar magnet UFC 500 F-EEx continuous flowrate measurement or measurement of sound velocity to determine (composition of) liquid product all operating data configuration galvanically isolated for active and passive mode useable as internal power supply for the binary outputs Current for Q = 0%: 0 16 ma for Q = 100%: 4 20 ma } settings in 1 ma increments (I max = 22 ma) Active mode load max. 680 Ohm Passive mode external voltage: 18 V DC Low-flow cutoff load 680 Ω cutoff on value: 1 19% cutoff off value: 2 20% } of Q 100%, setting in 1% increments Time constant 0.04 3600 s, setting in increments of 1, 0.1 or 0.01 s Forward / reverse measurement direction identified via status output (or pulse output) Internal power supply for binary outputs U int = 19 32 V DC / I 50 ma Pulse output Function continuous flow counting or measurement of sound velocity to determine (composition of) liquid product all operating data configurable galvanically isolated for active and passive mode Pulse rate for Q = 100% 10 3 600 000 pulses/h 0.167 60 000 pulses/min optionally in pulse per liter, m3, US gallons 0.0028 1 000 pulses/s (= Hz) } or user-defined unit Pulse width automatic: pulse duty cycle 1:1, max. 1000 pulses/s = max. 1000 Hz variable: 30, 50, 100, 200, 500 ms, 10 pulses/s 10 Hz Active mode connection: electronic counter internal voltage: 19 32 V DC, from current output load current: I max < 50 ma, operation without status output Passive mode connection: electronic or electromechanical counter external voltage: U ext 32 V DC / 24 V AC Low-flow cutoff current load: I max 150 ma cutoff on value: 1 19% cutoff off value: 2 20% } of Q 100%, setting in 1% increments Time constant 0.04 s or same as current output Forward / reverse measurement direction identified via status output (or current output) Status output Function configure as indicator for flow direction, errors or operating mode Active mode internal voltage: U int 19 32 V DC, from current output current load: I max < 50 ma, operation without pulse output Passive mode external voltage: U ext 32 V DC / 24 V AC current load: I max 150 ma Power supply 1. AC Version 2. AC Version AC / DC Version Standard Option Option 1. Rated voltage 230 / 240 V 200 V 24 V AC 24 V DC Tolerance band 200 260 V 170 220 V 20 27 V AC 18 32 V DC 2. Rated voltage 115 / 120 V 100 V Tolerance band 100 130 V 85 110 V Frequency 48 63 Hz 48 63 Hz Power consumption (incl. primary head) approx. 10 VA approx. 10 VA approx. 8 W When connected to functional extra-low voltage (24 V) safety separation (PELV) is essential (to VDE 0100 / VDE 0106 and IEC 364 / IEC 536 or equivalent national standards). Background Flowtubes UFM 500 Clamp-on UFM 600/610 Weld-om Open channel Gasflowtube GFM 700 Custody transfer ALTOSONIC V Calibration Installation notes Sizing guide Ordering guide / 5

UFM 800 Local display 3-field LCD Display function actual flowrate, measurement of sound velocity to determine (composition of) liquid product, forward, reverse and sum totalizer (7-digit) and status messages, each can be configured for continuous or sequential display Units: actual flowrate m 3, liter, US gallons per second, minute or hour, or in user-defined unit, e.g. liter/h or US gallon/day counter m 3, liter, US gallons or in user-defined unit, e.g. hecto liter or US million gallon (min. 1 year overflow time) Language of plain texts English, French, German, Dutch, others on request Display: 1st line (top) 8-character, 7-segment numeral and sign display, and symbols for key acknowledgement 2nd line (middle) 10-character, 14-segment text display 3rd line (bottom) 5 markers to identify display in measuring mode Housing Field housing Material aluminium with polyurethane finish Protection category (IEC 529/EN 60529) IP 67 equivalent to NEMA 6 (option IP 68) Sensor leads electrical connection between sensors and signal converter max. length: 50 m / 160 ft 6 /

Sizing guide Ordering guide UFM 800 for pipelines UFS 800 W Mounting location and installation Position the in the pipeline such that the measuring tube is completely filled with the process liquid at all times, even at zero flow velocity. Make sure that the measuring beam is approximately horizontal. Installation and alignment of FS 800 W ultrasonic sensors can be completed by KROHNE technicians. Install UFC 500 F signal converter in the vicinity of the measuring point (UFS 800 W sensors). Gas content The gas content in the process liquid must not exceed a maximum of 0.2% by volume at flowing conditions. Please note: Even in liquids that are virtually gas-free, large quantities of gas may form if the liquid is allowed to expand before reaching the measuring point, e.g. downstream of partially closed valves or small pump outlets. Inlet and outlet runs Single-beam Double-beam Inlet 20 x DN 10 x DN Outlet 5 x DN 10 x DN (DN = meter size, pipe diameter) Background Flowtubes UFM 500 Clamp-on UFM 600/610 Weld-om Open channel Gasflowtube GFM 700 for open channels UFS 800 C Mounting location and installation, Inlet run: 10 x B Outlet run: 5 x B (B = width of channel) Sensors can be installed either from the inside or the outside of the channel. Sensors aligned by KROHNE technicians are precisely set using laser alignment. Custody transfer ALTOSONIC V Calibration Installation notes / 7

UFM 800 Electrical connection, UFC 500 F (M 4.1) Power supply, power consumption and load rating of outputs: see Technical data (page 5) Current and pulse outputs (I + P) are galvanically isolated from all input and output circuits, when used in passive mode. Use the supplied signal cables (coaxial), length 5 m /16 ft, max. length 50 m /160 ft (optional), for the electrical connection between sensors and signal converter. Ambient temperature must be from 25 to +60 C ( 13 to +140 F), therefore do not cover signal converter with heat-insulating materials, and do not expose to strong sunlight or other heat sources. Avoid intensive vibration. Power supply 85-260 V AC 24 V AC / DC binary outputs current output for internal use only (PE = protective conductor) (FE = functional ground) Current output I active Current output I passive Pulse output P active for passive EC with internal voltage from current output Pulse output P passive and status output S passive with external voltage U ext 32 V DC/ 24 V AC I 150 ma load U ext U ext R i 680 Ω U ext 18 V DC U int. 19 32 V DC EC or relay R i 680 Ω I 50 ma EMC (e.g. Siemens D1) R 650 Ω 8 /