Agilent VQT Portable Analyzer J1981B Data Sheet

Similar documents
Agilent Technologies VQT Undercradle J4630A

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

N9051A Pulse Measurement Software

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Keysight Technologies Waveguide Power Sensors. Data Sheet

Making a S11 and S21 Measurement Using the Agilent N9340A

KickStart Instrument Control Software Datasheet

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies N9310A RF Signal Generator

Agilent 87075C Multiport Test Set

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Keysight M9485A PXIe Multiport Vector Network Analyzer

Agilent NFA Noise Figure Analyzer

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent N9320B RF Spectrum Analyzer

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Agilent U9391C/F/G Comb Generators

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Agilent 8762F Coaxial Switch 75 ohm

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight E5063A ENA Series Network Analyzer

Process Control Calibration Made Easy with Agilent U1401A

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet

Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note

30 Gb/s and 32 Gb/s Programmable Pattern Generator PPG Series Datasheet

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Keysight Technologies

Agilent N9342C Handheld Spectrum Analyzer (HSA)


Keysight 8762F Coaxial Switch 75 ohm

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Keysight Technologies

Keysight E5063A ENA Vector Network Analyzer

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Agilent J7211A/B/C Attenuation Control Units

Agilent NFA Noise Figure Analyzer

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Introduction. Part 1. Introduction...2


Keysight 86205B RF Bridge

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

Agilent U9397A/C FET Solid State Switches (SPDT)

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight Technologies x1149 Boundary Scan Analyzer. Data Sheet

Introduction. Part 1. Introduction...2

Agilent N9340B Handheld Spectrum Analyzer (HSA)

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Agilent NFA Noise Figure Analyzer

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

16 Gb/s, 30 Gb/s Gb/s, and 32 Gb/s Programmable PatternPro Pattern Generator PPG PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

Agilent N4916B De-emphasis Signal Converter

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight N9310A RF Signal Generator

MXG X-Series Signal Generator N5183B Microwave Analog

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies E4727A Advanced Low-Frequency Noise Analyzer. Data Sheet

10 GHz Linear Amplifier PSPL5866 Datasheet

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Agilent N9342C Handheld Spectrum Analyzer (HSA)

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

AC/DC Current Probe TCP0150 Datasheet

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Transcription:

Agilent VQT Portable Analyzer J1981B Data Sheet

Telephony Interfaces Analog FXO Number of ports: 2 Connector: RJ11 modular jack Limit Loop Current: variable Signaling: supports analog loop and ground start Accuracy of transmission or reception of sine wave: +/- 1 dbm under conditions: 300 Hz to 3400 Hz; -3 dbm to -50 dbm Analog E & M Number of ports: 2 Connector: RJ45 modular jack Addressing: Delay-dial, Immediate-start, Wink-start Signaling: Type I, II, III, V Transmission: two-wire, four-wire operation Accuracy of transmission or reception of sine wave: +/- 1 dbm under conditions: 300 Hz to 3400 Hz; -3 dbm to -45 dbm T1 Number of ports: 2 Jack: RJ48C Signalling: ISDN PRI and CAS Framing: D4, ESF Line Coding: AMI, B8ZS Zero bit suppression: selectable B8ZS, ZCS, no suppression E1 Number of ports: 2 Jack: RJ48C Impedance: 120 ohms (75 ohm converter available) Signalling: ISDN PRI and CAS Framing: CEPT G.703/G.704 Channel Associated Signaling Line Coding: HDB3 or AMI (no zero code suppression) Zero bit suppression: selectable B8ZS, ZCS, no suppression 10/100 Ethernet VoIP Number of ports: 1 Jack: RJ45 Transmission: 10/100Base-T (10/100 Mbps) Signaling: SIP (IETF RFC 2543); H.323 Media: RTP (IETF RFC 1889) Physical Dimensions Height: 10.5" Length: 7" Width: 16" Weight: 9.6 kg (21.1 lbs) Platform Processor: Memory: Hard disk drive: External drive: Pentium III 866MHz 256MB 40GB 1.44MB, 3.5" floppy drive 2

External drive: 1 CDRW Drive Display type: 14.1 XGA 1024x768 Video: 8MB video RAM Network Interface Card: 10/100 Mbps Built-in mouse: touchpad External mouse: serial mouse Keyboard: 1 External Video output: 1 Serial ports: 2 Parallel port: 1 Operating system: MS Windows NT 4.0, SP 6a Power: 115/230 V~, 50/60 Hz, 4/2A Regulatory compliances: UL/CUL, CE, C-Tick Feature Summary Distributed VQT software allows client software for PC control of remote VQT Servers Delay (one-way and roundtrip) Clarity using PESQ (ITU P.862) Clarity File using PESQ applied off-line to audio files Clarity Trending using PESQ (trending results on multiple repetitions) Clarity using PAMS Clarity File using PAMS applied off-line to audio files Clarity Trending using PAMS (trending results on multiple repetitions) Clarity using PSQM+ (enhanced version of ITU P.861) Clarity File using PSQM+ applied off-line to audio files Clarity Trending using PSQM+ (trending results on multiple repetitions) Clarity Distributed One-Way Measurements for PAMS and PSQM+ measurements Over 150 voice samples in 9 languages for testing Echo PACE (Perceived Annoyance Caused by Echo) Echo Double-Talk (measures performance during two-way conversation) Signal loss measurement DTMF twist and attenuation Voice Activity Detector: front-end clipping, hold-over time, and comfort noise generation Remote Audio Playback Tool Path confirmation Impulse response Network Simulator Automated Testing Interactive Testing Pre-defined tasklists Single, repeat, and continuous test modes End-to-end and round-trip measurements File Play and Record Noise Generator Tone Generator Port loopback Colorful, graphical presentation of test results Audio monitor Log files of results and configurations Active log viewing Full graphical viewing of saved test logs 3

Delay Description: Measures transmission delay of VF signal from source port to destination port (end-to-end), and from source port to destination port to source port (round-trip) Test signal: MLS Gain applied to test signal: -40dBm to 0dBm Audio path: end-to-end, roundtrip Measurement iterations: single, repeat, continuous Max iterations: 1440 Max measurement window: 2 seconds Resolution: 1 millisecond User-set thresholds: Measurements: Graph: maximum delay, minimum delay minimum delay, maximum delay, average delay, last delay, duration, max threshold exceeded, below min threshold, duration, tests completed, timeouts delay (over entire duration of transmission), max threshold, min threshold, summary, last measurement made Clarity (PESQ) Description: Measures perceptual quality of voice transmitted across a network Measurement Standard: ITU P.862 Perceptual Evaluation of Speech Quality Natural voice Local one-way and local round-trip; distributed one-way and distributed round-trip Measurement Iterations: Single (use Clarity Trending for multiple iterations) User-set thresholds: PESQ Listening Quality (LQ) score PESQ Listening Quality (LQ) score, PESQ threshold, Average Symmetrical Disturbance, Average Asymmetrical Disturbance, estimated delay Symmetrical Disturbance, Asymmetrical Disturbance, Error Surface, transmitted signal, received signal Clarity Trending (PESQ) Description: Performs PESQ measurement in multiple iterations for trending data. Adheres to Clarity (PESQ) specification, with the following exceptions: Measurement Iterations: repeat n times or continuous Maximum Iterations: 1440 User-set thresholds: PESQ Listening Quality (LQ) score Average PESQ (LQ) score, last PESQ (LQ) score, High PESQ (LQ) score, Low PESQ (LQ) score, Overall Average Symmetrical Disturbance, Overall Average Asymmetrical Disturbance, average estimated delay PESQ (LQ) score per iteration, average PESQ (LQ) score, minimum PESQ (LQ) score, maximum PESQ (LQ) score Clarity File (PESQ) Description: Performs offline Clarity (PESQ) measurement for pre-recorded audio files. Adheres to Clarity (PESQ) specification 4

Clarity (PSQM+) Description: Measures perceptual quality of voice transmitted across a network Measurement Standard: PSQM+, an enhancement to the ITU P.861 recommendation for Perceptual Speech Quality Measurement (PSQM) Natural voice Local one-way and local roundtrip, distributed oneway and distributed roundtrip Measurement Iterations: Single (user Clarity Trending for multiple iterations) Measurement Resolution: 0.01 PSQM+ maximum PSQM+, average PSQM+, outliers percentage average PSQM+, average PSQM+ threshold exceeded, maximum PSQM+, maximum PSQM+ threshold exceeded, outliers percentage, outliers percentage threshold exceeded, PSQM+ standard deviation, MOS equivalent, delay, loss/gain, correlation timeout reference signal, received signal, PSQM+ scoring over time, maximum PSQM+ threshold Clarity Trending (PSQM+) Description: Performs Clarity (PSQM+) measurement in multiple iterations for trending data. Adheres to Clarity (PSQM+) specification, with the following exceptions: Measurement Iterations: repeat n times or continuous Maximum Iterations: 1440 overall average PSQM+, maximum average PSQM+, outliers percentage Results are reported against the average PSQM+ score for each iteration: overall average PSQM+, overall average PSQM+ threshold exceeded, last average PSQM+, high average PSQM+, low average PSQM+, average outliers percentage, average outliers percentage threshold exceeded, average delay, average loss/gain, test duration, tests completed, correlation timeouts average PSQM+ per iteration, maximum PSQM+ per iteration, average PSQM+ threshold, outliers percentage per iteration, outliers percentage threshold Clarity File (PSQM+) Description: Performs offline Clarity (PSQM+) measurement for pre-recorded audio files. Adheres to Clarity (PSQM+) specification 5

Clarity (PAMS) Description: Measures perceptual quality of voice transmitted across a network Measurement Standard: Perceptual Analysis Measurement System (PAMS) Artificial speech, natural voice Local one-way and local roundtrip, distributed one-way and distributed roundtrip. Measurement Iterations: Single (user Clarity Trending for multiple iterations) Measurement Resolution: 0.01 LQS, 0.01 LES Listening Quality Score, Listening Effort Score Listening Quality Score, Listening Effort Score, Listening Quality Score threshold exceeded, Listening Effort Score threshold exceeded, correlation timeout Error surface, reference signal waveform, degraded signal waveform Clarity Trending (PAMS) Description: Performs Clarity (PAMS) measurement in multiple iterations for trending data. Adheres to Clarity (PAMS) specification, with the following exceptions: Measurement Iterations: repeat n times or continuous Maximum Iterations: 1440 Listening Quality Score, Listening Effort Score average LQS, minimum LQS, maximum LQS, average LES, minimum LES, maximum LES, LQS threshold exceeded, LES threshold exceeded, test duration, tests completed, correlation timeouts LQS, average LQS, minimum LQS, maximum LQS, LQS threshold, LES, average LES, minimum LES, maximum LES, LES threshold Clarity File (PAMS) Description: Performs offline Clarity (PAMS) measurement for pre-recorded audio files. Adheres to Clarity (PAMS) specification Echo - PACE (PSQM) Description: Measures echo received during and after transmission of voice, and the Perceived Annoyance Caused by Echo (PACE) Natural voice End-to-end, roundtrip with network echo simulation Measurement Iterations: Single Measurement Resolution: 0.01 PSQM+, 1 msec echo duration, 1 msec echo delay Average PSQM+, maximum PSQM+, percentage of echo-free speech, outliers percentage Average PSQM+, average PSQM+ threshold exceeded, maximum PSQM+, maximum PSQM+ threshold exceeded, percentage of echo-free speech, percentage of echo-free speech threshold exceeded, outliers percentage, outliers percentage threshold exceeded, duration of echo in speech, duration of echo in silence, echo delay, correlation timeout Reference signal, received echo signal, echo-inspeech duration, echo-in-silence duration, PSQM+ scoring over time, maximum PSQM+ threshold 6

Echo PACE (PESQ) Description: Measures echo received during and after transmission of voice, and the Perceived Annoyance Caused by Echo (PACE) Natural Voice End-to-end, roundtrip with network echo simulation Measurement Iterations: Single Measurement Resolution: 0.01 PESQ LQ, 1 msec echo duration, 1 msec echo delay Average PESQ LQ, maximum PESQ LQ, percentage of echo-free speech, outliers percentage Average PESQ LQ, average PESQ LQ threshold exceeded, maximum PESQ LQ, maximum PESQ LQ exceeded, percentage of echo-free speech, percentage of echo-free speech threshold exceeded, outliers percentage, outliers percentage threshold exceeded, duraction of echo in speech, duration of echo in silence, echo delay, Average Symmetrical Disturbance, Average Asymmetrical Disturbance, correlation timeout Reference signal, received echo signal, echo in speech duration, echo in silence duration, Symmetrical Frame Disturbance, Asymmetrical Frame Disturbance Echo Doubletalk (PSQM) Description: Measures performance of echo cancelers under conditions of Doubletalk Natural voice End-to-end in both directions Measurement Iterations: Single Measurement Resolution: 0.01 PSQM+ Average PSQM+, maximum PSQM+, outliers percentage Average PSQM+, average PSQM+ threshold exceeded, maximum PSQM+, maximum PSQM+ threshold exceeded, outliers percentage, outliers percentage threshold exceeded, correlation timeout Reference signal, doubletalk signal, received signal, PSQM+ scoring over time, maximum PSQM+ threshold Echo Doubletalk (PESQ) Description: Measures performance of echo cancelers under conditions of Doubletalk Natural Voice End-to-end in both directions Measurement Iterations: Single Measurement Resolution: 0.01 PESQ LQ Average PESQ LQ Average PESQ LQ, Average PESQ LQ threshold exceeded, Average Symmetrical Disturbance, Average Asymmetrical Disturbance, correlation timeout Reference signal, doubletalk signal, received signal, Symmetrical Frame Disturbance, Asymmetrical Frame Disturbance 7

Signal Loss Description: Measures the mean loss or gain of an audio signal transmitted across the system under test. The mean loss or gain is computed by comparing the average received signal level in db with the average reference signal level in db Natural voice, white noise, and a single frequency tone. White noise and tone signals may be selected in the range of 40 to 0 dbm and a tone signal has a selectable frequency range from 400 to 3400 Hz End-to-End, roundtrip Measurement Iterations: Single Measurement Resolution: 0.01 db. signal loss\gain threshold (db) mean signal loss\gain in db, signal loss threshold exceeded, correlation timeout reference signal, received signal Impulse Response Description: Measures and records the I/O transfer function of a network by transmitting test signal and measuring individual delays and amplitudes of time-segmented received signal. Records function as polynomial coefficients to be used in Network Simulator. Test signal: MLS Audio path: end-to-end Measurement iterations: single Max measurement window: 2 seconds Maximum FIR taps: 100 Resolution: 1 millisecond User-set thresholds: max delay threshold Measurements: impulse response (saved to IR file), max delay threshold exceeded, last delay, loss/gain, timeout Graph: delay and amplitude of received signal (over entire duration of transmission) 8

DTMF Tone Description: Measures impact of system under test on DTMF signal transmissions, in terms of twist, attenuation, and frequency deviation Test signal: DTMF (1 to 16 signals) Audio path: end-to-end Measurement iterations: single User-set thresholds: Measurements: Graph: twist threshold (max and min amplitudes) twist, low-freq tone amplitude, high-freq tone low-freq tone frequency shift, high-freq, tone frequency shift, timeout frequency response, low-freq tone marker, high-freq tone marker, low-freq tone amplitude marker, high-freq tone amplitude marker Voice Activity Detector Description: Measures the impact of a VAD on a VF signal in terms of front-end clipping and hold-over time. Test signal: MLS Gain applied to test signal: 30db to -5 db Test signal duration: 100 to 5000 msec Gain applied to tracer signal: -60db to -20db Audio path: end-to-end Measurement iterations: single Max correlation window: 2 seconds Resolution: 1 msec Measurements: Front-end clipping, hold-over time, transmitted signal duration, received signal duration Graph: received signal amplitude, received signal frequency spectrum, pulse start marker, VAD open marker, pulse end marker, VAD close marker File Play and Record Description: Transmits a user-selected audio file on one port, records the received signal on another port and saves to audio file. Tone and/or noise may be added to audio file transmission Gain applied to transmitted file: -60db to 60db Measurement iterations: single, repeat, continuous Network Simulator (Analog only) Description: Simulates a previously tested network by applying the impulse response file to a test signal. Gain, delay, tone, and/or noise may be added to test signal Gain applied to test signal: -60db to 60 db Delay applied to test signal: 11 to 1000 msec Noise Generator Description: Transmits noise signal over selected port Signal: MLS Signal duration: 128 to 16384 msec Gain applied to Signal: -60db to 0db 9

Tone Generator Description: Transmits single-frequency tone over selected port. Tone duration: not limited Gain applied to signal: -60db to 0db Audio Monitor Selectable source port monitoring modes: Selectable destination port monitoring modes: Selectable Remote audio monitor modes: transmit, receive, transmit and receive, none transmit, receive, transmit and receive, none Record, record and upload, record, upload, and automatically play, none Controlling PC Hardware Requirements: Minimum Configuration CPU: Pentium 3 200 MHz Memory: 64 MBytes Hard Disk: 100 MB Screen Resolution: 800x600 TCP/IP Stack: Microsoft s built-in TCP/IP stack Supported OS s: Windows 98 SE, Windows NT 4.0 SP 5, Windows 2000 Recommend Configuration CPU: Pentium 3 500 MHz Memory: 128 MBytes Hard Disk: 100 MB Screen Resolution: 1024x768 TCP/IP Stack: Microsoft s built-in TCP/IP stack Supported OS s: Windows 98 SE, Windows NT 4.0 SP 5, Windows 2000 Operating Conditions Temperature Operating: Non-operating: Humidity Operating: Non-operating: Altitude Operating: Non-operating: +5 C to +40 C (+41 F to +104 F) -40 C to +70 C (-40 F to +158 F) 5% to 93% relative humidity, non-condensing 5% to 93% relative humidity, non-condensing -305 to 4570 meters (-1000 to 15,000 feet) -460 to 12,200 meters (-1500 to 40,000 feet) 10

Related Literature Brochure Downtime is not an Option for Enterprise 5988-2430EN Technical Overview VQT Portable Analyzer J1981 A/B, VQT Network Server J1987A, Advisor VQT Undercradle J4630A 5968-7723E Data Sheet VQT Network Sever J1987A 5988-3045EN Warranty Hardware: 1 year Agilent Instrument Warranty and Service Plans Agilent Instrument Phone Support Software: 90 day media warranty 11

www.agilent.com Agilent Ordering Information J1981B Module Interfaces J1981B-200 J1981B-201 J1981B-202 J5479A Software J1979A J1982A J1983A J1997A J5422A Accessories J1996A J5480A Education H7211B-207 VQT Portable Analyzer VQT dual-port analog FXO and dual-port analog E/M interface VQT dual-port T1 interface for VQT VQT dual-port E1 interface for VQT VQT 10/100 SIP and H.323 interface software license VQT Client software license License to use PAMS voice clarity measurement License to use PSQM voice clarity measurement License to use PESQ voice clarity measurement IP Telephony Reporter VQT phone adapter 10/100 Cardbus NIC for VQT Voice over IP Technology and Testing Warranty and Support Services Hardware 1 year Agilent Instrument Warranty and Service Plans Agilent Instrument Phone Support Software 90 day media warranty You can also contact one of the following centers and ask for a communication solution representative: Australia 1800 629 485 Austria 0820 87 44 11 Belgium +32 (0) 2 404 9340 Brazil +55 11 4197 3600 Canada 877 894 4414 China 800 810 0189 Denmark +45 70 13 15 15 Finland +358 (0) 10 855 2100 France +33 (0) 825 010 700 Germany +49 (0) 1805 24 6333 Hong Kong 800 930 871 India 1600 112 929 Ireland +353 (0)1 890 924 204 Israel +972 3 6892 500 Italy +39 (0)2 9260 8484 Japan 0120 421 345 Luxembourg +32 (0) 2 404 9340 Malaysia 1800 888 848 Mexico +52 55 5081 9469 Netherlands +31 (0) 20 547 2111 Philippines 1800 1651 0170 Russia +7 095 797 3963 Singapore 1800 375 8100 South Korea 080 769 0800 Spain +34 91 631 3300 Sweden 0200 88 22 55 Switzerland Italian 0800 80 5353 Switzerland German 0800 80 5353 Switzerland French 0800 80 5353 Taiwan 0800 047 866 Thailand 1800 226 008 United Kingdom +44 (0) 7004 666666 USA 800 452 4844 Product specifications and descriptions in this document are subject to change without notice. Agilent Technologies, Inc. 2003 Printed in U.S.A. January 9, 2003 *5988-4041EN* 5988-4041EN Together with Agilent, gain the Extreme Productivity Improvements that your business demands! www.agilent.com/comms/xpi