THE AMPLIFIER. A-B = C subtractor. INPUTS Figure 1

Similar documents
EXPERIMENT 7 The Amplifier

BIO-ELECTRIC MEASUREMENTS

EXPERIMENT 8 Bio-Electric Measurements

EXPERIMENT 5 Bioelectric Measurements

Laboratory Project 1B: Electromyogram Circuit

Lab E5: Filters and Complex Impedance

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Oscilloscope and Function Generators

2 Oscilloscope Familiarization

EECE Circuits and Signals: Biomedical Applications. Lab ECG I The Instrumentation Amplifier

Ph 3455 The Franck-Hertz Experiment

Laboratory 3 (drawn from lab text by Alciatore)

EMG Electrodes. Fig. 1. System for measuring an electromyogram.

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

Activity P52: LRC Circuit (Voltage Sensor)

ENG 100 Lab #2 Passive First-Order Filter Circuits

Oscilloscope Measurements

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

total j = BA, [1] = j [2] total

Physics 303 Fall Module 4: The Operational Amplifier

E40M. Instrumentation Amps and Noise. M. Horowitz, J. Plummer, R. Howe 1

Experiment P45: LRC Circuit (Power Amplifier, Voltage Sensor)

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Lab E5: Filters and Complex Impedance

Physics 2310 Lab #2 Speed of Sound & Resonance in Air

Laboratory Exercise 6 THE OSCILLOSCOPE

Chabot College Physics Lab Ohm s Law & Simple Circuits Scott Hildreth

EE 230 Experiment 10 ECG Measurements Spring 2010

4: EXPERIMENTS WITH SOUND PULSES

Optical Pumping Control Unit

When input, output and feedback voltages are all symmetric bipolar signals with respect to ground, no biasing is required.

Laboratory Project 1: Design of a Myogram Circuit

LAB 7: THE OSCILLOSCOPE

ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

LAB 8: Activity P52: LRC Circuit

Special-Purpose Operational Amplifier Circuits

Class #8: Experiment Diodes Part I

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

Combinational logic: Breadboard adders

Equipment and materials to be checked out from stockroom: ECE 2210 kit, optional, if available. Analog BK precision multimeter or similar.

THE SPEAKER. The decibel scale is related to the physical sound intensity measured in watts/cm 2 by the following equation:

Introduction to oscilloscope. and time dependent circuits

CHAPTER 6. Motor Driver

10: AMPLIFIERS. Circuit Connections in the Laboratory. Op-Amp. I. Introduction

Sampling and Reconstruction

AC Measurements with the Agilent 54622D Oscilloscope

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

Device Interconnection

Lab #11 Rapid Relaxation Part I... RC and RL Circuits

Integrators, differentiators, and simple filters

PHYSICS 107 LAB #9: AMPLIFIERS

LT Spice Getting Started Very Quickly. First Get the Latest Software!

Experiment 1 Alternating Current with Coil and Ohmic Resistors

Using the V5.x Integrator

EE 210 Lab Exercise #5: OP-AMPS I

CRO AIM:- To study the use of Cathode Ray Oscilloscope (CRO).

Exercise 1: Touch and Position Sensing

Florida Atlantic University Biomedical Signal Processing Lab Experiment 2 Signal Transduction: Building an analog Electrocardiogram (ECG)

Differential Amplifier : input. resistance. Differential amplifiers are widely used in engineering instrumentation

Digital Applications of the Operational Amplifier

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

Mechatronics. Analog and Digital Electronics: Studio Exercises 1 & 2

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

Op-Amp Simulation Part II

University of California, San Diego Department of Electrical and Computer Engineering

Electrical Measurements

Transformer Waveforms

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Intro To Engineering II for ECE: Lab 7 The Op Amp Erin Webster and Dr. Jay Weitzen, c 2014 All rights reserved.

Worksheet for Exploration 31.1: Amplitude, Frequency and Phase Shift

EE 210: CIRCUITS AND DEVICES

EE320L Electronics I. Laboratory. Laboratory Exercise #6. Current-Voltage Characteristics of Electronic Devices. Angsuman Roy

WELCOME TO PHYC 307L Junior Lab II

Tektronix digital oscilloscope, BK Precision Function Generator, coaxial cables, breadboard, the crystal earpiece from your AM radio kit.

Biomedical Instrumentation (BME420 ) Chapter 6: Biopotential Amplifiers John G. Webster 4 th Edition

Experiment 5 The Oscilloscope

Class #9: Experiment Diodes Part II: LEDs

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

The Digital Oscilloscope and the Breadboard

Resonant Frequency of the LRC Circuit (Power Output, Voltage Sensor)

ENGR 40M Project 4: Electrocardiogram. Prelab due 24 hours before your section, August Lab due 11:59pm, Saturday, August 19

MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START

Experiment 9 : Pulse Width Modulation

P08050 Testing Strategy Document

Test No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE

INTRODUCTION TO ENGINEERING AND LABORATORY EXPERIENCE Spring, 2015

The 34th International Physics Olympiad

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

Operational Amplifiers

Standing Waves in Air

CONNECTING THE PROBE TO THE TEST INSTRUMENT

ELR 4202C Project: Finger Pulse Display Module

Experiment 13: LR Circuit

Sonoma State University Department of Engineering Science Spring 2017

EE 3305 Lab I Revised July 18, 2003

Module 1, Lesson 2 Introduction to electricity. Student. 45 minutes

Cornerstone Electronics Technology and Robotics Week 21 Electricity & Electronics Section 10.5, Oscilloscope

Transcription:

OBJECTIVES: THE AMPLIFIER 1) Explain the operation of the differential amplifier. 2) Determine the gain of each side of the differential amplifier. 3) Determine the gain of the differential amplifier as a function of frequency. 4) Determine the common mode rejection percentage of the differential amplifier. INTRODUCTION In this experiment it will be our goal to acquaint you with the differential amplifier and how the device can be used to measure small bio-electric signals. Before using the device as a tool in biological and physiological measurements, it will benefit you to have some idea of the basic structure of the differential amp. The differential amp is basically a device that takes the "difference" between two voltage signals. The result of this subtraction is then amplified (or increased) so that it can be conveniently viewed on an oscilloscope or other recording devices. We will see the usefulness of subtracting two voltage signals in next week's experiment when we use the differential amp to view cardiac signals and muscle potentials. A schematic diagram of a differential amp is shown in figure 1. V a (Red) A A-B B V b Vr (Red) (Black) A-B = C subtractor amplifier kc k OUTPUT INPUTS Figure 1 In the above diagram, the first red input lead has voltage V a, the second has V b, and the black lead defines a reference voltage V r. The input signals can be thought of as the voltage differences between the input lead and the reference voltage: A = V a - V r B = V b - V r The subtractor part of the differential amplifier forms the difference between the two input leads: C = A - B = V a - V b. The voltages here refer to voltages at any particular instant of time. 1

Introductory Physics Experiments (Physics 252, v4.0) This signal (A - B) is then sent through an amplifier and its amplitude gets increased "k" times. The signal k (A-B) becomes the output from the differential amp. The value "k" is the GAIN of the amp. GAIN = output input The amplifier part of the differential amplifier makes voltages bigger at each moment. It cannot make the input voltage vary more or less quickly. Thus, an ideal amplifier has no effect on the frequency of its input signal C = A - B or on the shape as a function of time. It only changes its size. Of course, the signal A - B can be quite different from A or B by themselves. It might appear as if the differential amplifier takes the hard way by amplifying (V a - V r ) - (V b - V r ) instead of amplifying (V a - V b ) directly. Any real amplifier actually produces (as you will measure) an output related to not just the difference of its inputs, but also to their sum. So without the reference signal, we would have: Output = k (V a - V b ) + g V +V a b 2 where g is known as the common mode gain, the gain for an input presented in common to both inputs of the amplifier: if V a = V b = V comm, V comm = (V a + V b ) / 2. An ideal differential amplifier would amplify only the difference, with g = 0 and k=100 or so. How close it comes to this is measured by the common mode rejection ratio, CMRR = (1 g / k ) 100% Stray electrical signals from outside sources, called noise, pervades the room where voltages V a and V b are measured. The amplitude of this noise is often much greater than the amplitude of the biological signals to be studied. Since this noise is common to any signals measured in the same area, we can make a third measurement, V r, of just the noise: V a = A + noise V b = B + noise V r = noise Without using the reference signal, the noise cancels in the difference term, but not in the sum term. Our imperfect amplifier would produce: Output = k (A - B) + g A + B 2 + noise The differential arrangement uses as inputs A = (V a + noise) (V r + noise) and B = (V b + noise) (V r + noise). Now, the noise also cancels in the sum term and we get: Output = k (A - B) + g A + B 2 2

The Amplifier (Version 4.0, 1/7/2002) Note if all inputs are equal, V a = V b = V r, then A = B = 0, and we expect zero output. Since the noise is much larger than the desired signals A and B, the arrangement which subtracts the reference voltage produces much less contamination of the output signal. The biological signals would be completely obscured if not for this property of the amplifier, which is known as Common- Mode Rejection, because it rejects signals sent in common to both of the input leads. We will measure the characteristics of the amplifier by arranging input signals of A=0, then B=0, and finally A=B. From the equations above, the output for these conditions should be Out(A=0) = -B(k - g/2) -kb if g << k Out(B=0) = A(k +g/2) ka if g << k Out(A=B) = Ag A second feature of the differential amplifier is that it can be "AC coupled". This means that there is an electronic circuit that passes only input potentials varying fairly rapidly in time. The AC coupling circuitry will not pass constant voltage DC or slowly varying voltage at frequencies below 1/2 cycle per second. AC coupling also removes any DC component from an AC signal. For example, a signal that varies from 5 mv to 15 mv at, say, 10 Hz, is an AC signal with a DC component of 10 mv. (See Figure 2.) The AC coupler will remove the 10mV DC component and pass an AC signal varying from -5 mv to +5 mv to the amplifiers. AC coupling is accomplished by capacitors in the input circuit that act as a large resistance to DC signals. The differential amplifier may also be "DC coupled" with no restriction on the input. It amplifies whatever it sees at the input: AC, AC + DC, or pure DC. Note that the oscilloscope may also be AC-coupled using the switch under the input connector. Before AC coupling 15 10 Voltage (mv) 5 0-5 Time DC - Component (10mV) -10 3

Introductory Physics Experiments (Physics 252, v4.0) After AC coupling: (DC component eliminated) 15 10 Voltage (mv) 5 0-5 Time -10 Figure 2 In next week's experiment we will look at a specific biological measurement, the electrical potentials produced by the human cardiac muscles. The heart puts out a signal varying from about -4 mv to +4 mv at a frequency of about 72beats = 1.2 Hz corresponding to the contractions of the cardiac 60 sec muscles. Customarily, placing an electrode on the skin of each arm makes this measurement. There is an arm-to-arm DC potential of about 20 mv due to the biceps and shoulder muscles. In addition, the whole body acts as an antenna picking up electromagnetic waves from the surrounding space. These signals are mostly 60 Hz from the 60-Hz power lines in the building. In a typical situation this may produce a potential between any two points on the body of 50-60 mv with a dominant frequency of 60 Hz. Thus, the cardiac signals are completely lost in the noise. If the differential amplifier is connected to a subject as in Figure 3 with an electrode on each arm and one on a leg, which is the common reference point, the cardiac muscle signals can be monitored. The AC coupling feature will remove the DC level from the input due to the large muscles in the body. The inputs to the amplifier are the AC potential differences between the right arm and right leg, and between the left arm and right leg. The difference will be the AC potential difference between the right arm and the left arm. The noise induced by EM waves passing through the body is common to both arm-leg inputs and thus is removed by the common mode rejection feature. The output is the amplified cardiac signals alone. + + Red Red diff amp Black APPARATUS: Figure 3 4

The Amplifier (Version 4.0, 1/7/2002) The apparatus that we will use today are a differential amp, a signal generator, and an oscilloscope, shown schematically in figure 4. signal generator oscilloscope A B AC DC output ON power offset ON battery Hi low DC AC input differential amplifier Figure 4 The differential amp is contained in a transparent plastic box. On the right side of the box, there is a connector with three wires with alligator clips attached. Two of them are "red" and the other one is "black". The two red leads are the INPUT to the differential amp. The black lead is the ground or reference for the signals sent into the two red leads. On the left side of box, there are two BNC connectors for the OUTPUT of the amp. They are labeled "AC" and "DC", for AC and DC coupling, respectively. On the front, from the left, there are a power switch, the OFFSET adjusting knob, the battery switch, the High/Low gain selection switch, and the DC/AC coupling selection switch. Reference material: review section of introduction on Making Graphs. 5

6 Introductory Physics Experiments (Physics 252, v4.0)

The Amplifier (Version 4.0, 1/7/2002) Partners Name Section PROCEDURE: Preparations: Please ensure that the amplifier and its power supply (or battery if used) are turned ON. 1. Fine-adjust the DC OFFSET knob of the amplifier. a) Set the amplifier coupling switch to DC b) Connect the DC output to channel B of the oscilloscope. c) Set the oscilloscope to DC coupling (LCD panel should show DC for channel B). d) Turn the signal generator off. You should see a horizontal trace on the scope. e) Press the GND (ground) button on the scope to give a 0 volt input, and adjust the Y position knob (channel B) on the scope so that the line is in the middle of the screen. This is where the oscilloscope itself thinks 0 volts is. f) Now press the GND button again to look at the amplifier output when it has no input. This is where the amplifier thinks that 0 volts is. Adjust the OFFSET knob so that the line is also in the middle of the screen. If you can t see the trace, the OFFSET knob is badly out of adjustment. Switch to the coarse-voltage sensitivity scale of 10 V/cm, center the trace with the amplifier. Continue to center with finer and finer sensitivity scales. g) Turn the signal generator back on. 2. a) Turn the amplifier OFFSET knob just a little. Is the vertical position of the trace on the scope (channel B) affected by turning the OFFSET knob? 3. Put everything back to AC coupling. Make the following settings and connections a) Set the amplifier coupling switch to AC. b) Set amplifier to LOW gain. c) Connect signal generator output to channel A of the oscilloscope. d) Connect differential amp input (alligator clips) to signal generator output. One red lead goes to OUTPUT (red connector) of the signal generator, the other red lead and the black lead to GROUND (black connector) of the signal generator. e) Connect the AC output to channel B of the oscilloscope. f) Set oscilloscope to AC coupling (LCD panel should show AC for channel B). Now, the scope is set up to view the input signal on channel A and the output signal on channel B. The amplifier is set up for AC coupling. 4. With the amplifier set up for AC coupling, turning the OFFSET knob should not affect the vertical position of the output trace (channel B) on the scope except momentarily. (Only turn the knob a little, otherwise you will need to repeat step 1.) 7

Introductory Physics Experiments (Physics 252, v4.0) Part I. Gain of the differential amp (at a constant frequency = 200 Hz) First, we wish to determine the GAIN of each side of the differential amp. To do this, we connect one input lead (red) to OUTPUT of the signal generator, and the other input lead (also red) and the black reference lead to the GROUND of the signal generator. That gives one input voltage (say B) = 0, and we measure ka; swapping the location of the red leads gives kr. 1. Set signal generator frequency at 200 Hz. 2. Set the peak-to-peak voltage of the input signal to 5 mv. To set this, view channel A. Adjust the output amplitude knob on the signal generator to set the desired voltage. Measure your peak-to-peak signal with the cursors. Adjust the amplitude knob on the signal generator to increase or decrease your signal, then remeasure (It may be necessary to change the output amplitude coarse setting). Repeat until you reach the desired voltage. Be sure to change scales on the oscilliscope to get a good view of the signal if necessary. 3. Measure the peak-to-peak voltage of the output. To measure the output voltage, view channel B on the scope and use voltage cursors to measure V pp. Record the data in the table below (side 1). 4. Repeat steps 2 and 3 for other input voltages shown in the table below. 5. Plot the output (vertical axis) vs. input (horizontal axis) voltage. 6. Interchange the two red leads and repeat steps 2 through 5. Record the data in the table (side 2). INPUT (mv) 5. 10. 15. 20. 25. 30. OUTPUT (side 1) (mv) OUTPUT (side 2) (mv) Questions: 1. Do the data points on the graph form approximately a straight line? If yes, what does the slope of the line represent? 2. What units does the slope have? 3. Find the gain of each side from the slopes. Gain (side 1) = Gain (side 2) = 4. When one of the red leads is connected to the GROUND on the signal generator, what is the signal that is going into that side of the amplifier? 8

The Amplifier (Version 4.0, 1/7/2002) 5. Are there any units associated with the gain of the amplifier? Why? Part II. Gain as a function of frequency (at a constant INPUT=10 mv) 1. Set the input to 10 mv peak to peak. 2. Measure the output of the differential amp for each frequency shown in the table below. 3. Calculate the gain of the differential amp for each frequency. Adjust the input if necessary to return it to 10mV. 4. Plot gain (vertical axis) vs. frequency (horizontal axis) on a semi-logarithmic graph. FREQUENCY (Hz) OUTPUT (mv) GAIN 20 50 100 200 400 600 700 800 900 1000 1300 1600 2000 5000 10000 Questions: 1. Is the gain you measured at 200 Hz consistent with your measurement in part 1? 2. What happens to the gain of the differential amp at high frequencies? 3. Estimate the highest and lowest frequency signal one would encounter when looking at cardiac signals. Is this amplifier adequate? (Hint: To see good detail in the shape of the heartbeat, following all the wiggles in the signal, you would need a frequency range of roughly.1f to 100f, where f = the basic heart frequency. See page 4.) Part III. Common-mode rejection 9

Introductory Physics Experiments (Physics 252, v4.0) To measure the percentage of common-mode rejection, we connect both input leads (red) to the OUTPUT of the signal generator. Attach the black lead to GROUND. 1. Set the input to 1.0 volt and 200 Hz. Measure the peak-to-peak voltage of the input by using the voltage cursors (channel A). INPUT = volts 2. Measure the peak-to-peak voltage of the output by using the voltage cursors (channel B). OUTPUT = mv = volts 3. Calculate the common-mode gain. Common-mode gain = g = OUTPUT/INPUT = 4. Calculate the % common-mode rejection ratio (CMRR). common _ mode _ gain % CMMR = (1 - g/k) 100 = 1 100 gain _ of _ one_ side Questions: = % (Use the gain of either side that you determined from Part I). 1. When both input leads (red) are connected to the output of the signal generator, what should be the output of the differential amplifier ideally? 2. Ideally, what should be the % CMRR for the differential amplifier? 3. Compare your value for the %CMRR with the ideal value. Are they close? 10