MASTERFLEX AQUASTOP. Centrally and externally placed PVC Waterstops

Similar documents
HIGHLAND WATERSTOP Externally and Centrally Placed PVC Waterstops

1. CONNOLLY KEYJOINT 1. PRODUCT NAME 2. SUPPLIER 3. PRODUCT DESCRIPTION 4. KEY FEATURES 5. FIXING INSTRUCTIONS 6. SPECIFICATIONS 7.

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

INSTALLATION INSTRUCTIONS

joining materials - wood

SECTION MANHOLES

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

INSTALLATION INSTRUCTIONS

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Rodney Hunt. A GA Industries Company Glydaseal Gates

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

Installation instructions for co-extruded louver-board profiles

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

multipanel Installation (panels) CONTENTS

DYNEX SOFFIT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 908 [2016] Appraisal No. 908 (2016) BRANZ Appraisals

Installation Recommendations for Finless Frame Doors

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Integrity Polygon and Round Top Installation and Finishing Instructions

INSTALLATION INSTRUCTIONS FOR QUICK-STEP LAMINATE WITH HYDROSEAL TECHNOLOGY.

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

TECHNICAL MANUAL. OPTIMAJOINT Free Movement Joint. Free Movement Joint System for Heavy Traffic

Installation Instructions for. Before You Begin TOOLS REQUIRED

CLASSIC RANGE PLUS RANGE PHOTO WALL. Pre-installation check-list

Flashing Materials. Rough Opening Preparation

Engineered Hardwood Flooring Installation Instructions

Repair Instructions. Durametallic PSS III. Experience In Motion. Split Seal

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

WELDING. Section nine 9.1 CORRECT TOOLS

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

EKSPAN. Standard F Series Bearings. Description. Bearing types F series bearings are available in three forms - Typical 21F details.

INSTALLATION GUIDE Twinback

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

CLASSIC RANGE PLUS RANGE CREATE RANGE - PHOTO WALL

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

TerraLink. Twisted Wire Mesh Gabions & Mattresses Welded Wire Mesh Gabions. Data Sheet s Index. TerraLink Products

Vinyl Windows Manufactured by VPI Quality Windows

Method of Build 1. Fire. Sound

Curtain Wall Installation Guide

NewTech - CleverDeck Composite Decking Installation Guidelines

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

PRIVACY INSTALLATION FOR: Standard 6 H x 8 W Privacy Fence 4 x 4 Post Sleeve & Brackets Dog Ear or Straight-Edge Pickets 1.75 x 3.

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

² TL Beton-StB 07 = German technical conditions for construction materials for concrete road pavements

LuxCore Installation Instructions

SHADOWBOX INSTALLATION FOR: Standard 6 H x 8 W Shadowbox Fence 5 x 5 Routed Posts Dog Ear or Straight-Edge Pickets 1.75 x 3.5 Rail

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

INSTALLATION INSTRUCTIONS

A. Extent of structural precast concrete work is shown on drawings and in schedules.

Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE

Section 914. JOINT AND WATERPROOFING MATERIALS

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE)

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

Install Instructions for Solano Jurastone #4012 Mantel

SEA SELF DRILLING, THREADED, HOLLOW BAR / GROUT-ABLE SOIL NAILS / ANCHORS

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

SELF-ALIGNING PLASTIC INCLINOMETER CASING IN BOREHOLES. Model GEO-LOK. Roctest Limited, All rights reserved.

Installation Instructions

rondo exangle drywall finishing sections

PREFOAM - PERMANENT STADIUM SEATING RISER SYSTEM FOR FLOOR MONTED SEATING PART 1 GENERAL DESCRIPTION

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

Installation Instructions

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

LE7000 Provincial Built-in (Zero Clearance) Kit Instructions.

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

Install Instructions for Torrance Jurastone #4004 Mantel

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

INSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world

GLOSSARY OF TERMS SECTION 8

Make every component count.

THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM

AF-4 Grooved Flange Adapter

Important Notices. Manway Lockout Point

Panel Installation Instructions

Instructions For sheeting a typical Single Span Polytunnel

COMPOSITE SIDING INSTALLATION GUIDE

PAT installation of a Sun Dome over a in-ground

The New Unrivalled SRB Titan Magnet Clamps & Spartan Composite Adjustable Sideforms

SPRINGLOK SPRINGLOK FLASHING SYSTEM PRODUCT BROCHURE ENGINEERED PRODUCT SYSTEMS

Welding & Fabrication Tools R8 Mini Pliers

InstallatIon InstructIons for 2-lIte PatIo Door unassembled

Liniar Window. installation guide

SECTION METAL FABRICATIONS

Operating & Maintenance Instructions 25 Injection Moulding Machine

USER S MANUAL. Horizontal inclinometer system Model TES-AN-25H

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Thanks for shopping with Improvements! 7 ft. Wall Christmas Tree w/ Stand Item #419359

THE GOOD GUIDE TO ELECTROFUSION JOINTING....Connect

NX7 SERIES 5-1/2 HANDRAIL

Transcription:

Centrally and externally placed PVC Waterstops Description MASTERFLEX AQUASTOP is a range of centrally placed and externally placed PVC Waterstops extruded from high grade PVC compound. Primary Uses MASTERFLEX AQUASTOP is designed to provide a complete sealing network for expansion and contraction/ construction joints in water retaining and water excluding in-situ concrete structures. The profiles are supplied in straight lengths to be butt jointed on site. Factory made intersections are available for complex junctions. The use of MASTERFLEX AQUASTOP prevents the passage of water through expansion/ contraction/ construction joints in the following typical structures.. Canals/ culverts Water tanks Reservoirs Dams Sewerage Treatment Plants Liquid retaining vessels All cast in-situ concrete structures to retain or exclude water Advantages Complete range of profiles and sizes to suit all construction requirements. Reinforced eyeleted fixing flanges on centrally placed profiles for positive location in joints prevents collapse of profile during concrete placing. Simple on-site butt welding. Four valve sealing system on all profiles. Premoulded intersection/ junction pieces available. plus grout check fins on all construction/ contraction joint profiles. Technical Data Typical Properties Form: Extruded PVC Solids content: 100% Colour: Blue Tensile strength: 15 N/mm 2 Minimum Elongation at break: 350% Minimum Shore A Hardness: 75 O 80 O Toxicity in potable water: None IEJ/ EEJ Extension: 15 mm IEJ/ EEJ Transverse Shear: 25 mm ICJ/ ECJ Extension: 6 mm Alkali resistance: Pass Hydrocarbon resistance: Pass Standards ASTM D 638 : 91 (Tensile/ Elongation) US Corps of Engineers CRD-C572-74 (Alkali Resistance) BS 6920 (Toxicity) Instron Tensometer (Extension/ Transverse Shear) Profiles Centrally placed MASTERFLEX AQUASTOP profiles provide a barrier across all joints in-situ concrete structures by casting the section centrally into the edges of adjacent concrete components. Used in most water retaining and water excluding structures, they are capable of withstanding water pressure from either the internal or external face. MASTERFLEX AQUASTOP IEJ (Internal Expansion Joints): Expansion bulb sections principally for expansion joints but can be used for construction/ contraction joints. With reinforced eyeleted fixing flanges for wiring the waterstop to surrounding rebar. Design Considerations PVC Waterstops were originally designed as simple dumbbell profiles which worked on the valve sealing action of the opening joint putting the waterstop in tension, thus sealing the water path. Later designs included multi ribs and fins, in what is known as the tortuous path principal of an extended potential water track created by the ribs and fins. MASTERFLEX AQUASTOP combines all the accepted and proven principals of PVC Waterstop in four valve and tortuous path design, together with reinforced eyeleted fixing flanges on all centrally placed profiles

MASTERFLEX AQUASTOP ICJ (Internal Construction/ Contraction Joints): Plain web sections for construction/ contraction joints, also with reinforced eyeleted flanges and grout check fins to prevent grout loss from formwork. MASTERFLEX AQUASTOP ECJ (External Construction/ Contraction Joints): Sections are plain web incorporating grout check fins to prevent grout loss at formwork. Externally placed MASTERFLEX AQUASTOP profiles are principally designed for basement, foundation and floor slab applications in both vertical and horizontal joints. Each externally placed section incorporates a reinforced railing flange for fixing to the formwork or blinding concrete. The four valves allow good concrete compaction and very secure anchorage into the concrete. MASTERFLEX AQUASTOP EEJ (External Expansion Joints): Sections have a flat top, wedged expansion box for positive anchorage and good seating of joint fillers. EEJ sections can also be used in construction/ contraction joints. The bottom web in the expansion box is thinned to cater for excessive subsidence or seismic movement should it occur. Special Profiles MASTERFLEX AQUASTOP 200M ICJ/E is an economic construction/ contraction joint profile specifically for use in kicker and contraction joints in small structures such as water tanks cast in-situ manholes, channels etc where there are no expansion joints and wall or slab thicknesses do not exceed 200mm.Includes an eyeleted flange. MASTERFLEX AQUASTOP 250 ICJ/X & 250IEJ/X are10mm thick web profiles with 26mm valve heights, for applications where there is high water pressure or head of water in excess of 70meters. Both profiles include reinforced eyeleted fixing flanges and are compatible with 250 ECJ/ EEJ profiles in an integral network. 250 ICJ/X

250 IEJ/X the efficiency in performance in any way. See typical detail below. Waterstop Selection MASTERFLEX AQUASTOP PVC Waterstops are designed for use within the performance parameters indicated under the headings Technical Data and Typical Properties. Centrally placed profiles (ICJ & IEJ) are usually located midway in the slab or wall thickness across the joints in concrete structures. They will equally prevent the passage of water through the joint from either face. They are particularly suited to water retaining structures and in walls and slabs where pressure differential may occur such as in reservoir walls. They are equally appropriate for joints in suspended slabs, vertical wall joints and lift joints. Externally placed profiles (ECJ & EEJ) are of particular advantage for their ease of installation in basement and foundation applications in situations where they are firmly supported against back pressure, i.e. in water retaining structures (base slab) where they are placed on the blinding concrete. Size of Waterstop The choice of width of profile is mainly governed by slab/ wall thickness, position of reinforcing steel and aggregate size. As a general rule, the 250mm width profiles are appropriate for slab/ wall thickness over 250mm, allowing good compaction and width of barrier to water penetration. For concrete members less than 250 mm the use of a smaller profile approximating to the actual slab or wall thickness will be appropriate. Installation MASTERFLEX AQUASTOP ICJ & IEJ profiles must be installed so they are securely held in the correct position whilst the concrete is poured. The concrete must be fully and properly compacted around the waterstops (the use of MBT s Rheodynamic admixtures to produce self compacting concrete is of great advantage to avoid voids or porous areas after concrete placing). Where reinforcement is present, an adequate clearance must be left between this and all waterstops to permit proper compaction of the concrete. The eyelets in the reinforced flanges of the ICJ and IEJ profiles allow them to be wired to the surrounding reinforcing steel. The eyelets are an integral part of the profiles and being placed outside the outer valves, cannot create a water path around the profile or impair MASTERFLEX AQUASTOP ECJ & EEJ profiles when used on ground slab blinding concrete where a permanent, firm and stable support is given, usually require no fixing. The profile is simply laid centrally over the line of the joint to be formed. Fixing to vertical shuttering is simplified by nailing with double headed nails through the outer reinforced flange to provide a firm fixing as shown below. Equipment Heat welding equipment is available to enable site jointing to be carried out efficiently. Jointing jigs ensure that the mating surfaces of the waterstop are accurately aligned while the heater blade heats the waterstop to the necessary temperature for jointing.

Jointing Jigs 150mm AQUASTOP EEJ/ ECJ 200mm AQUASTOP EEJ/ ECJ 250mm AQUASTOP EEJ/ ECJ 150mm AQUASTOP IEJ/ ICJ 200mm AQUASTOP IEJ/ ICJ/ ICJ/ E 250mm AQUASTOP IEJ/ ICJ/ ICJ/X, IEJ/X 220 Volt Electric Heater Blades for use with all jigs. carefully remove the waterstop.do not flex the joint until it has cooled. The joint is now complete. When cold, test it by flexing the waterstop several times. Intersection Pieces Standard factory produced welded and moulded intersections are available for all MASTERFLEX AQUASTOP profiles as detailed below. Intersections for IEJ/ICJ, IEJ/X ; ICJ/X profiles. Flat Mitre Flat 3 Way Site Jointing Instructions Reliable jointing of MASTERRLEX AQUASTOP waterstops can be carried out rapidly onsite with AQUASTOP heat welding equipment. Complete welding kits, comprising simple jigs and electric blades, are available and provide all that is needed to make tough joints between all PVC waterstop sections, Note that when ordering MASTERFELX AQUASTOP equipment, both the type and width of waterstop must be stated. Heat welding of AQUASTOP Waterstops: Make sure that the heater blade is clean, plug it into the correct voltage electricity supply and leave in a safe position to warm up. Ensure that the ends of the waterstop to be jointed are of the same width and profile; clean them with water or CLEANING SOLVENT NO. 2 and dry them. Clamp them in the correct profile slots of the jig provided and cut both ends off square with a sharp knife, flush with the faces of the jig. Flat 4 Way Note: An allowance must be made for waste and for the 5 to 10mm that will be taken up by melting when calculating the length of waterstop required. Loosen the jig and slide them back so that approximately 10mm of each waterstop end projects and then clamp the jig tightly in position. Position the heater blade on the bars between the jig and slide them together until the waterstop ends are pressed firmly against the sides of the blade. The PVC should melt without burning or charring. Hold the jig firmly in position until a bead of molten PVC approximately 3mm in diameter appears along either side of the heater blade. T Piece Intersections for EEJ/ECJ profiles Edge Mitre Slide the jig apart a little and remove the heater blade with an upward movement. This will ensure that it takes as little PVC as possible with it. Quickly joint the molten ends by sliding the jig together and exerting pressure. approximately 20 seconds to allow the molten PVC to fuse completely. Switch off the heater blade. While it is still hot, clean thoroughly with emery paper or a wire brush ready for the next joint. Unclamp the jig and

Flat Mitre Flat 3 Way EEJ to IEJ / IEJ X ECJ to ICJ / ICJ X T-Piece T-Piece Flat 4 Way If a composite edge mitre is needed, simply cut off one of the horizontal legs. Edge Mitre ( Int) Edge Mitre ( Ext ) Supply / Estimating. MASTERFLEX AQUASTOP profiles are supplied in 15 Metre rolls. The exceptions are 250 EEJ in 12 Metre rolls and 250 ICJ/X, 250 IEJ/X in 10M Rolls Flat intersections are supplied with a leg length of 250mm from centreline. Edge intersections are supplied with 100mm legs. Health and Safety Composite Intersections. These are required when a change from horizontal to vertical occurs in the same type of joint i.e. from slab expansion to wall expansion joint or slab contraction to wall contraction joint Hot welding of PVC produces hydrochloric acid fumes, which in confined spaces may exceed the minimum TLV of 5 ppm. Therefore forced ventilation must be provided or a suitable respirator used. In open site applications, it is not considered that any health dangers exists. Whilst any information contained herein is true, accurate and represents our best knowledge and experience, no warranty is given or implied with any recommendations made by us, our representatives or distributors, as the conditions of use and the competence of any labour involved in the application are beyond our control As all BASF technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue. BASF Construction Chemicals Jordan P.O. Box 752 11118, Amman, Jordan Tel: +962-6 5521672 Fax: +962 6 5523148 www.mbt-near-east.com e-mail: enquirycc.neareast@basf.com