Advanced Test Equipment Rentals ATEC (2832)

Similar documents
Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Advanced Test Equipment Rentals ATEC (2832)

Agilent 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources

Keysight Technologies 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources. Data Sheet

Keysight Technologies 8160xx Family of Tunable Laser Sources. Data Sheet

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Keysight Technologies 8160xx Family of Tunable Laser Sources

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

Agilent 8902A Measuring Receiver Product Note

Agilent 83430A Lightwave Digital Source Product Overview

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent 8902A Measuring Receiver

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

LIGHTWAVE, OPTICAL TEST EQUIPMENT

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Coherence control of the FOS-79800F. applications, Stimulated Brillouin Scattering. these reasons, controlling DFB source spectral

Keysight Technologies 81602A Extra High Power Tunable Laser

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent 87415A, 87400A Microwave Amplifiers

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent 970-Series Handheld Multimeters Data Sheet

GM8036 LASER ANALYZER SWEEP SPECTRUM OPTICAL. Technical Specifications v1.01 March, 2011

Agilent N4373B Lightwave Component Analyzer Testing advanced 40Gb/s components with highest relative and absolute accuracy

Base Station Installation and Maintenance

Agilent dc Electronic Loads Models N3300A-N3307A

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent 8761A/B Microwave Switches

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent E8267C PSG Vector Signal Generator

Advanced Test Equipment Rentals ATEC (2832)

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

NOW WITH BROADER TUNING RANGE

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent EPM Series Power Meters

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

Agilent PNA Series RF Network Analyzers

Agilent E8267C/E8257C/E8247C PSG

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Agilent 83711B and 83712B Synthesized CW Generators

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

DWDM CW DFB Laser Module

Advanced Test Equipment Rentals ATEC (2832) Agilent 8510 System Solutions

RIO ORION Series 1550nm Low Phase Noise Narrow Linewidth Laser Module

Model 1782 DWDM High Power CW Source Laser

OSICS Multifunction Platform

56:/)'2 :+9: 3+'9;8+3+4:

ModBox - Spectral Broadening Unit

Applications. Features. Data Sheet FRL15TCWx-D86-xxxxxA Apr Full Band Tunable DFB Laser Module

Keysight 8160xx Series Tunable Laser Family. User s Guide

Agilent 8920A RF Communications Test Set Product Overview

1782 DWDM High Power CW Source Laser

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm

Using the Integrating Sphere in the Multiple Application Platform (MAP)

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

LM-QPSK-R. Lightwave Modulator for QPSK/ QAM. Features. Applications. Functional Diagram

Xeston Technologies. XESTON 1550nm DWDM CW DFB Laser With PM Fiber. XQF935 Series Specification Datasheet (Preliminary)

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

1782 DWDM High Power CW Source Laser

Agilent 8657A/8657B Signal Generators

Low Noise, High Power DFB Laser Part #LN Pxx

Agilent 8560 E-Series Spectrum Analyzers

OM2210 Coherent Receiver Calibration Source OM2210 Datasheet

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent PNA Microwave Network Analyzers

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

DWDM CW DFB Laser Module

Tunable Lasers. Figure 1, Photo of the Tunable Laser OEM Module, Model: TL-MC040TA101

Model 1772 DWDM High Power CW Source Laser

ME7220A. Radar Test System (RTS) Target Simulation & Signal Analysis for Automotive Radar Exceptional Performance at an Affordable Price.

POLARIZATION EXTINCTION RATIO MEASUREMENT TEST SETFOR V-GROOVE ASSEMBLIES AND PM PATCHCORDS

ModBox 1550 nm 44 Gb/s NRZ C, L bands ; 100 Mb/s - 44 Gb/s Reference Transmitter

IQS-2100/FLS-2100 OPTICAL LIGHT SOURCE. Telecom Test and Measurement

IQS/FLS-2600B TUNABLE LASER SOURCE

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Miniature, Ruggedized, 20 GHz RF over Fiber Transmitter

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER

Narrow Linewidth Full Band Tunable DFB Laser Module. Component Specifications

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

Optical Dispersion Analyzer

Agilent 8560 EC Series Spectrum Analyzers Data Sheet

Wavelength Calibration for the 8614X Series Optical Spectrum Analyzers. Product Note

expanding the possibilities

Agilent 8703A Lightwave Component Analyzer Technical Specifications

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent 81689A / 81689B / 81649A Compact Tunable Laser Modules February 2002 The 81689A, 81689B, 81649A compact tunable laser modules offer superior performance now also in the compact module class. As they are tunable with continuous output power, they are the most flexible stimulus for the test of optical amplifiers, DWDM components as well as for the test of complete DWDM systems.

Compact tunable lasers for C- and L-band The Agilent 81689A and 81689B modules operate in the C-band from 1525 nm to 1575 nm, whereas the Agilent 81649A covers the L-band from 1570 nm to 1620 nm. Test of optical amplifiers A variable amount of the compact, yet fully remote controlled Agilent 81689A, 81689B and 81649A tunable laser modules, in combination with the 81682A and 81642A high power Tunable Laser, is the ideal solution to characterize optical amplifiers for use in DWDM applications. The 81689A, 81689B and 81649A compact tunable laser modules provide the high stimulus power needed to test today's optical amplifiers. Together with the 81651A optical attenuator module, an output power dynamic range of more than 60 db can be achieved. Even without the attenuator module the power can be attenuated by 9dB (10dB for 81689B) e.g. to equalize power levels of several sources. Polarization Maintaining Fiber for the test of integrated optical devices The 81689A, 81689B and 81649A modules are ideally constructed to characterize integrated optical devices. Their optional Panda PMF output ports provide a well defined state of polarization to ensure constant measurement conditions on waveguide devices. A PMF cable easily connects an external optical modulator. The 81689A, 81689B and 81649A is available with both, standard singlemode fiber and Panda type PMF. Compact module for DWDM multi-channel test The 81689A, 81689B and 81489A allow a realistic multi-channel test bed for DWDM transmission systems to be set up. Their flexibility make them the preferred choice for tests of DWDM transmission system during installation and maintenance phases. Compact spare for DFB modules in ITU grids The 81689B for the first time solves the sparing nightmare for users of DWDM combs. In combination with a comb of 81662A DFB lasers the 81689B can replace any DFB between 1525nm and 1575nm without power penalty. Remote control & PnP software drivers for easy process automation Its continuous, mode-hop free tuning makes it quick and easy to set even the most complex configurations to the target wavelengths and power levels, just by dialing or using the vernier keys. A 8163B mainframe can host 2 compact tunable laser modules. This allows for the most compact C- and L- band stimulus solution available today. Each 8164B mainframe can host up to four units of the 81689A, 81689B or 81649A in its upper slots. The 8166B is most interesting for high channel count solutions. Up to 17 compact tunable laser modules can be hosted here. The 81649A, 81689A and 81689B are produced to ISO 9001 international quality system standard as part of Agilent's commitment to continually increasing customer satisfaction through improved quality control. Specifications describe the instrument's warranted performance. They are verified at the end of a 2 m long patchcord and are valid after warm-up and for the stated output power and wavelength ranges. Each specification is assured by thoroughly analyzing all measurement uncertainties. Supplementary performance characteristics describe the instrument s non-warranted typical performance. Every instrument is delivered with a commercial certificate of calibration and a detailed test report. For further details on specifications, see the Definition of Terms in Appendix C of the Compact Tunable Laser User's Guide.

81689A, 81689B, 81649A Compact Tunable Laser for Multi-channel test applications Agilent 81689A Agilent 81689B Agilent 81649A Wavelength range 1525 nm to 1575 nm 1525 nm to 1575 nm 1570 nm to 1620 nm Wavelength resolution 0.01 nm, 1.25 GHz at 1550 nm 0.01 nm, 1.25 GHz at 1550 nm 0.01 nm, 1.17 GHz at 1595 nm Absolute wavelength accuracy (typ.) [1] ±0.3 nm ±0.3 nm ±0.3 nm Relative wavelength accuracy [1] ±0.3 nm ±0.15 nm ±0.15 nm Wavelength repeatability [1] ±0.05 nm ±0.05 nm ±0.05 nm Wavelength stability (typ., over 24 h at constant temperature) [1] (typ., over 1 h at constant temperature) [1] ±0.02 nm ±0.01 nm ±0.005 nm ±0.01 nm ±0.005 nm Tuning speed (typ.) <10 sec/ 50 nm <10 sec/ 50 nm <10 sec/ 50 nm Linewidth (typ.) [2] with Coherence Control ON (typ.) [2] 20 MHz --- < 20MHz >100MHz < 20MHz >100MHz Output power (continuous power on during 6 dbm (1525 1575nm) 10 dbm (1525 1575nm) 6 dbm (1570 1620nm) tuning) Minimum output power 3 dbm 0 dbm 3 dbm Power stability (at constant temperature) [3] ±0.03 db over 1 hour, ±0.015 db over 1 hour, typ. ±0.0075 db over 1 hour, typ. ±0.05 db over 24 hours typ. ±0.06 db over 24 hours Power repeatability (typ.) [3] ±0.02 db ±0.02 db ±0.02 db Power linearity ±0.1dB ±0.1dB ±0.1dB Power flatness versus wavelength ±0.3 db ±0.2 db ±0.2 db ±0.015 db over 1 hour, typ. ±0.0075 db over 1 hour, typ. ±0.05 db over 24 hours Side-mode suppression ratio (typ.) [2] > 40 db (1525 1575 nm at 0 dbm) > 45 db (1525 1575 nm at 3 dbm) > 45 db (1570 1620 nm at 0 dbm) Signal to source spontaneous emission ratio (typ.) [4] 39 db/ nm (1525 1575 nm at 6 dbm) 44 db/ nm (1525 1575 nm at 10 dbm) 42 db/ nm (1570 1620 nm at 6 dbm) Relative intensity noise (RIN, typ.) < -137 db/hz (100 MHz 2.5 GHz, at +3 dbm) < -137 db/hz (100 MHz 2.5 GHz, at +7 dbm) < -137 db/hz (100 MHz 2.5 GHz, at +3 dbm) Dimensions 75 mm H, 32 mm W, 335 mm D (2.8" x 1.3" x 13.2") 75 mm H, 32 mm W, 335 mm D (2.8" x 1.3" x 13.2") 75 mm H, 32 mm W, 335 mm D (2.8" x 1.3" x 13.2") Weight 1 kg 1 kg 1 kg [1] At CW operation. Measured with wavelength meter based on wavelength in vacuum. [2] Measured by heterodyning method. [3] 500 ms after changing power. [4] Measured with optical spectrum analyzer at 1 nm resolution bandwidth. Listed options Option 021: standard single mode fiber, straight contact output connector Option 022: standard single mode fiber, angled contact output connector Option 071: polarization maintaining fiber, straight contact output connector Option 072: polarization maintaining fiber, angled contact output connector

Supplementary performance characteristics Modulation Internal digital modulation 50% duty cycle, 200 Hz to 300 khz. >45% duty cycle, 300 khz to 1 MHz. Modulation output (via Mainframe): TTL reference signal. External digital modulation > 45% duty cycle, fall time < 300 ns, 200 Hz to 1 MHz. Modulation input (via Mainframe): TTL signal. External analog modulation ±15% modulation depth, 5 khz to 1 MHz. Modulation input: 5 Vp-p Coherence control (81649A/81689B) For measurements on components with 2 m long patchcords and connectors with 14 db return loss, the effective linewidth results in a typical power stability of < ±0.025 db over 1 minute by reducing interference effects in the test setup. General Output isolation (typ.): 38 db Return loss (typ.): 55 db (options 022, 072) 40 db (options 021, 071) Polarization maintaining fiber (Options 071, 072) Fiber type: Panda. Orientation: TE mode in slow axis, in line with connector key. Extinction ratio: 16 db typ. Laser class: Class IIIb according to FDA 21 CFR 1040.10, Class 3A according to IEC 825-1; 1993. Recommended re-calibration period: 2 years. Warm-up time: < 40 min, immediate operation after boot-up. Environmental Storage temperature: 20 C to +70 C (81689A) 40 C to +70 C (81689B, 81649A) Laser Safety Information All laser sources specified by this data sheet are classified as Class 1M according to IEC 60825-1 (2001). All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July- 26 Operating temperature: 15 C to 35 C Humidity: < 80 % R.H. at 15 C to 35 C Specifications are valid in non-condensing conditions.

This page intentially left blank

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test & measurement needs Online assistance: www.agilent.com/coms/lightwave Phone or Fax United States: (tel) 1 800 452 4844 Related Agilent Literature: Agilent 8163A Lightwave Multimeter Agilent 8164A Lightwave Measurement System Agilent 8166A Lightwave Multichannel System p/n 5988-1568EN Canada: (tel) 1 877 894 4414 (fax) (905) 206 4120 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry Perot Laser p/n 5988-1570EN Agilent Power Sensor Modules Agilent Optical Heads Agilent Return Loss Modules p/n 5988-1569EN Agilent 8163A/B Lightwave Multimeter Agilent 8164A/B Lightwave Measurement System Australia: Agilent 8166A/B Lightwave Multichannel System (tel) 1 800 629 485 (fax) (61 3) 9210 5947 Configuration Guide p/n 5988-1571EN New Zealand: (tel) 0 800 738 378 (fax) 64 4 495 8950 Asia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 Agilent 8163B Lightwave Multimeter Agilent 8164B Lightwave Measurement System Agilent 8166B Lightwave Multichannel System p/n 5988-3924EN Product specifications and descriptions in this document subject to change without notice. Copyright 2001 Agilent Technologies February 12 2002 5988-3675EN