Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier

Similar documents
Certified according to DIN EN ISO Technical Datasheet. FOP 60 and OPTV. Fibre-Optic Amplifier and Receiver

VTM Local Display Unit with Frequency and Analogue Output

Technical Datasheet FOP 60 and OPTV Fibreoptical Amplifier and Lightpulse Receiver

CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

KFS. Flap-type flow meter. Design and range of application

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

Operating Instructions

Certified according to DIN EN ISO Technical Datasheet & Manual. TD-Ex. Carrier-Frequency Amplifier with Dual Pickup

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Speed and Positioning Sensor GEL 2478

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Design and applications

Digital Input Output Module for Zone 2 Series 9470/33

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

A6500-UM Universal Measurement Card

Inductive sensor slot-type SI2-K08-AP7

Binary Output without Power Supply Series 9176

... for hydraulic and general applications in hazardous areas

Assembly. Front view. Switch Power Rail

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Isolating Repeater Input Series 9163

Binary Output Series 9175

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Digital Input Output Module for Zone 1 Series 9470/32

Assembly. Front view. Switch Power Rail

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Isolators A3/1. Vibration Transducer Supply Unit Series

Digital Input Output Module for Zone 2 Series 9470/33

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

SINEAX B 811 Power Pack with additional Functions

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

PRetrans Table of contents

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

SINEAX / EURAX 2I1 Passive DC signal isolator

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Universal Intelligent 2-wire DIN Rail Transmitters

SALES SERVICE +358 (0)

Target disk flowmeter for liquids and gases

Operating Instructions

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pulse Scaler for DIN Rail Attachment

INSTALLATION AND OPERATION MANUAL

Electrical Alarm Contacts

Technical Information Barrier RB223

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Positive Displacement Flow sensors

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Temperature Input Module for Zone 1 Series 9482/32

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Assembly. Front view. Power Rail

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1.

Temperature head transmitter itemp PCP TMT 181

Preset counters, electronic

PHOTOCOUPLER PS2801A-1,PS2801A-4

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Remote Switching Unit nivotester FTL 320

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Single-Channel Safety Barriers Series 9001

Signal conditioner - MACX MCR-UI-UI-NC

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Universal Intelligent 2-wire DIN Rail Transmitters

SBEx-2S BINARY SEPARATOR

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Head mounted Temperature Transmitter TF02/TF02-Ex

Absolute encoders - SSI EX approval ATEX EEx d IIC T6 Optical single and multiturn encoders 14 bit ST / 12 bit MT

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

RMA42. Technical Information

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Remote I/O. 74 Remote I/O. Remote I/O System

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

INSTRUCTION MANUAL (ATEX / IECEx)

Rail mounted Temperature Transmitter TH102/TH102-Ex

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Transcription:

Certified according to DIN EN ISO 9001 Technical Datasheet EWS Intrinsically Safe Supply and Separation Amplifier

Description... 3 Technical Data... 3 Options... 7 Notes... 7 Connections... 8 Ordering Information... 9 Marking...... 10 Index Index

Description The EWS is an intrinsically safe supply unit and separation amplifier. The EWS supplies KEM pickups installed in hazardous areas and transmits the output frequency of these pickups. The EWS must be installed outside hazardous areas. All in- and output circuits are isolated. Intrinsically safe supply circuit 12 V to supply intrinsically safe KEM pickups installed in hazardous areas in threewire technique. Two intrinsically safe signal input circuits ATEX 100a II 2 G [EEx ia] IIC to connect pickups as per DIN 19234 (NAMUR) in two-wire technique and active and passive pickups. LEDs will indicate short circuit and line breakage. Options Frequency doubling and detection of ratio nal direction Failure signalling relay for NAMUR mode Outputs Open-Collector PLC output active 24 V NAMUR DIN 19234 Technical Data Input Circuits (Intrinsically Safe) Terminals KL1, KL2, KL3, KL4 Ex-protection ATEX 100a II 2 G [EEx ia] IIC BVS 03 ATEX E 208 Supply Circuits Terminals KL1, KL3 Outputs and mains supply are isolated. open circuit voltage 12 V ±5 % series resistor max operating current short circuit current parameters for safety regulations 120 Ω 20 ma Imax. = 110 ma (short circuit proof) Umax. = 12,6 V Imax. = 110 ma Pmax. = 342 mw Li 0; Ci 0

Signaleingänge KL 2, KL 3, KL 4 Intrinsically safe signal input circuits according to DIN 19234 NAMUR for Connection of active and passive pickups Isolation of outputs and mains supply (no isolation of signal inputs and the intrinsically safe supply circuit) Separate indication of short circuit and line breakage for each channel by a red LED open circuit voltage short circuit current max. power 8.5 V 15 ma (short-circuit proof) 30 mw switch rate fmax. 5 khz for outputs as per DIN 19234 duty cycle 1:1 switch time switch current difference switch level switch state for line breakage (LB) switch state for short circuit (KS) safety-relevant parameters 200 μs (under test conditions) 0.25 ma ± 0.15 ma on - transistor conducting 1.65 ±0.15 ma off - transistor blocked 1.85 ±0.2 ma I < 150 μa transistor conducting RL < 360 Ω transistor blocked Umax. = 12.6 V Imax. = 18 ma Pmax. = 55 mw Li 0; Ci 0 version EWS - xxxxc-nsx - ** - ** (option) Umax. = 40 V Imax. = 1.5 A 4

Outputs (not intrinsically safe) terminals KL6, KL7, KL8 The intrinsically safe input circuits are isolated from the mains supply and the outputs which are not intrinsically safe. Open Collector NPN 0 V for both outputs common. Imax. Umax. UCEmin. UCEmax.. swicht rate fmax. max. transmission fmax. (typical figures) 100 ma 30 V 1 V 1.5 V 2.5 bis 5 khz according to external wiring and duty cycle U < 5 V; R < 2 kω; fmax. < 5 khz U < 12 V; R < 1 kω; fmax. < 5 khz U < 12 V; R < 2 kω; fmax. < 4,5 khz U < 24 V; R < 5 kω; fmax. < 3 khzz duty cycle 1:1; R = pullup; U = applied voltage DIN 19234 (NAMUR) 0 V for both outputs common. low level high level Umax. Imax.. Pmax. < 1 ma > 2.2 ma 30 V 25 ma 0.4 W switch rate fmax. 5 khz (duty cycle 1:1) 5

active 24 V/PLC version 0 V for both outputs common. high level low level Imax. short circuit resistance switch rate fmax. > 22 V (620 Ω Iout) max. 30 V blocking 10 ma/chanel max. 2 h 2 up to 3.5 khz according to external wiring and duty cycle Supply Terminals KL9, KL10 supply voltage AC, 45-65 Hz power consumption 230 V + 15% 10 % Version xxxac approx. 4.5 VA 115 V ± 10 % ca. approx. 6 VA with option SP 24 V ± 10 % Version 24 DC approx. 3 VA DC 20-35 V approx. 5 VA with option SP Further Technical Data ambient temperature 0 up to +50 C ingress protection housing housing dimensions installation IP20 plastics l = 70 mm, w = 45 mm, h = 115 mm and 125 mm with option SR mounting rail DIN EN 50022-35 or wall mounting terminals electric shock hazard protection as per VDE 0106/100 wire size weight max. 2 2.5 mm² 350 up to 450 g 6

Options Frequency Doubling and Detection of Rotational Direction The EWS doubles the frequency of two frequency signals which are phase-shifted by 90 (± 30 ). The duty cycle of the doubled frequency is variable. The EWS detects the rotational direction by the phase. Outputs (non-intrinsically safe) forward/backwards detection channel 1 (terminals KL 6, KL 7) transistor conducting (channel 2 leads) transistor blocked (channel 2 lags) doubled frequency channel 2 (KL 8, KL 7) The following applies: The output transistor of channel 1 (terminals KL6, KL7) conducts, if the input signal 2 (KL 4) leads. For type TD pickups in gear flow meters connected as shown on page 6: The output transistor of channel 1 conducts, if the arrow direction on the type plate of the gear flow meter and the flow direction are the same. Failure Signalling Relay for NAMUR Mode potential free relay contact: Umax. = 30 V, Imax. = 100 ma, Ri = 12 Ω The relay will drop out with: Drop in operating voltage Short circuit or line breakage of one or both intrinsically safe signal input circuits terminals KL4, KL3 or KL2, KL3 Notes for the User: a) Please consider the following: Installation specifications for associated devices which are intrinsically safe The»Safety regulations for electrical devices«the»special conditions for safe use«as per EC-Type Examination Certificate b) The EWS must be installed outside hazardous areas. c) The max length for cables to connect pickups or amplifiers is 500 metres. d) Max ambient temperature must not exceed +50 C (please also consider self heating). A gap of at least 30 millimetres should be kept between two EWS units. e) The inputs are suitable for both active and passive pickups. f) When the max switch frequency is bypassed, no output signal will be available. Therefore a bypassing of the max. switch frequency has to be avoided with safety-relevant measurements. The max. switch frequency depends on the duty cycle of the input signals and the wiring of the outputs (cf. technical data»outputs«). g) For detection of the rotational direction, the frequency signals of the pickup must be of the same frequency and be phase-shifted by 90 (± 30 ). If this is not the case, you will receive undefined output signals. 7

Connections Terminal Connections: Intrinsically safe current circuits 35 1 = UB +12 V intrinsically safe supply 2 = inpunt channel 1 3 = 0 V pickup supply and signal input circuits 4 = input channel 2 5 = n. c. not intriusically safe current circuits 6 = output channel 1 (flow direction) 7 = 0 V of signal outputs 8 = output channel 2 (2x f) 9 = UB 10 = +UB 14 = failure-signalling relay 15 = failure-signalling relay 77 12345 LB CH 2 KS CH 2 LB CH 1 KS CH 1 678 9 45 10 drilling scheme for wallmounting 60 Wiring Example: VTEK/P-Ex Push Pull EWS 024 DC Nxx OC +UB 1 UB 1 6 7 Out CH1 0V 1350 Ω push pull 0 V/GND 2 3 In CH1 0V 2 3 8 9 10 Out CH2 _ UB 24 V DC +UB 1,3 kω collector 4 emitter 5 TD...Ex +UB 1 UB EWS 024 DC NxD OC 1 6 Out CH1 470 Ω 2 In CH1 2 7 0 V push pull 1 0 V 3 8 (Out CH2) 470 Ω push pull 2 3 0 V/GND 4 In CH2 4 9 10 _ UB 24 V DC +UB 8

Wiring Diagram 1 3 ++ intrinsically safe pickup supplys upply 10 9 2 in CH1 out CH1 6 flow dircetion f x 2 0 V 7 4 in CH 2 out CH2 8 output stages LB+KS Detector 14 15 failure signalling relay Ordering Information EWS xxxxc Nxx ** ** SR = failure-signalling relay (only for NAMUR input signals) Outputs: OC = open collector (standard) NA = NAMUR (DIN 19234) SP = active 24 V (PLC output) Inputs: Nxx = standard, cf.»input circuits«, page 2 NxD = reverse-flow detection and doubled frequency Supply Voltage 230A = 230 VAC +15 %, 10 % 45 to 65 Hz 110A = 110 VAC ±10 % 45 to 65 Hz 024A = 24 VAC ±10 % 45 to 65 Hz 024D = 24 VDC 9

Marking KEM Küppers Elektromechanik GmbH 0123 II 2G [EEx ia] IIC BVS 03 ATEX E 208 EWS xxxxx-nxx-xx Nr. 1234567 0 C Ta 50 C KL1/3 Umax = 12.6 V; Imax = 110 ma; Pmax = 342 mw Ci = 0; Li = 0 KL2/3 and KL3/4 Umax = 12.6 V; Imax = 18 ma; Pmax = 55 mw Ci = 0; Li = 0 Special conditions for safe operation The EWS described above is an»affiliated intrinsically safe device«. It must not be installed in hazardous areas. The device shall only be connected with intrinsically safe devices of a certified type or such corresponding to paragraph 1.3, EN 50020:1994. This connection must be in a way that the intrinsic safety is maintained. For a safety factor of 1.5 the electrical parameters of connection (leads and intrinsically safe device) must not exceed the following (maximum) values: pickup supply: terminal 1 and KL3: C = 1 μf; L = 3 mh signal inputs: terminal 2 3 and terminal 4 3: C = 1 μf; L = 100 mh 10