Effective Date: September 2017 Void After: September Product: Cast Iron Soil Pipe and Fittings (Hubless) File No. 4818

Similar documents
Effective Date: August 2016 Void After: August Product: Sewer Pipe & Fittings (PVC) File No. 1367

Effective Date: October Rev. 5/11/2018- Void After: October 2018

Effective Date: January Rev. 5/11/2018- Void After: January Product: Lead Free Water Filtration Product File No.

Effective Date: January Rev. 3/21/2018- Void After: January Product: Ceramic Plumbing Fixtures File No. 8317

Effective Date: September Rev. 8/17/2018- Void After: September Product: Bathtubs (Plastic) File No. 0851

Effective Date: December 2018 Void After: December Product: Plumbing Fixture Fittings File No. 3730

Effective Date: May 2018 Void After: May 2019

LIST PRICE. Tyler Cast Iron Soil Pipe & Fittings

Effective Date: February 2018 Void After: February Product: Bathtubs (Plastic) File No. 2464

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

Cast Copper Alloy Solder Joint Drainage Fittings: DWV

A. This Section includes plumbing fixtures and related components.

EVALUATION SUBJECT: PLASTIC PLUMBING FIXTURES DIVISION: PLUMBING SECTION: PLUMBING EQUIPMENT PLUMBING FIXTURES

Grease Interceptor Design Checklist

Oil-Water Separator Design Checklist

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

QUALITY ASSURANCE SPECIFICATION

LICENSING AGREEMENT FOR USE OF THE SAFE FEED/SAFE FOOD SEAL

Effective Date: January 2018 Void After: January Product: Flushometer Valves (Urinal or WC) File No. 4712

001: 2007 CEB STANDARD

Series 9000 Vinyl Fixed Window

SECTION PLUMBING FIXTURES

Series 6000 Vinyl Single Hung

Series 9000 Vinyl Single Hung

NUMBER SOP STANDARD POLICIES AND PRACTICES PAGE 1 OF 4. April 15, 2012 STANDARDIZED PART MARKING PRACTICES REVISES POLICY DATED: July 1, 2010

Series 9000 Vinyl Fixed Window

SECTION CABLE TRAYS

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

SECTION MANHOLES

Series 9000 Vinyl Horizontal Slider

Product Guide Specification

Series 6000 Vinyl Horizontal Slider

Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings DWV

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Originally Issued: 06/28/2012 Revised: 06/21/2017 Valid Through: 06/30/ Design

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

METAL FABRICATION SECTION 8: METAL FABRICATION SCOPE MATERIAL.

Metric sine bars and sine tables (excluding compound tables)

CITY OF MUSKEGO DRAFTING STANDARDS

I-VICFLEX.VS1. Victaulic VicFlex Style VS1 Dry Sprinkler WARNING WARNING TECHNICAL DATA BEND CHARACTERISTICS INSTALLATION INSTRUCTIONS SIDEWALL

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

ALLOY STEEL SOCKET SET SCREWS 1

PLASTIC PIPE & FITTINGS. September 14, 2017 K-1 NO-HUB SOIL PIPE & FITTINGS LUBRICANT BENDS CONNOLLY Y SV SOIL PIPE SADDLE

REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE

MATERIALS DIVISION MEMORANDUM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Pipe Product Catalog Table of Contents

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves.

Standard Specifications

PS901500E IDENTIFICATION, MARKING, HANDLING, PROCESSING AND INSPECTION OF CRITICAL PARTS

PRE-PRINT. IaPMo Is InstallatIon standard For CoPPEr PlUMBInG tube, PIPE, and FIttInGs

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Recommended Practice for Wet and Dry Thermal Insulation of Subsea Flowlines and Equipment API RECOMMENDED PRACTICE 17U FIRST EDITION, FEBRUARY 2015

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

ERRATA AND REVISIONS to the CANADIAN PLUMBING CODE

Originally Issued: 04/28/2010 Revised: 03/26/2019 Valid Through: 04/30/2020

1. ASME A Scheme for the Identification of Piping Systems.

Ash Brook Golf Course Scotch Plains, New Jersey

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

3400 Tectura Designs Precast Concrete

Alfa Laval Material Standard T

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

AESS Documents prepared by CISC ad hoc committee

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

SECTION METAL FABRICATIONS

ZIP System Roof Sheathing INSTALLATION MANUAL A REVOLUTION IN ROOFING

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

Echotel Model 910 Ultrasonic Level Switch

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

Volume II: Xirtec 140 PVC Corzan Dimensional Data & Weights

A. Action Submittals: Written and graphic information that requires Architect's responsive action.

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

GUIDELINE SPECIFICATIONS

Students will learn to correctly prepare, assemble, and solvent weld ABS piping.

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

Consideration of External Pressure in the Design and Pressure Rating of Subsea Equipment API TECHNICAL REPORT 17TR12 FIRST EDITION, MARCH 2015

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

11-1/4 OD at Transition Point. Microcosmic. 4th and Brannan Street Platform Station Project. Elevation. Moto Ohtake 2014

East Central College

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

EVALUATION REPORT GAF Materials Corporation 1361 Alps Road, Building 7-3 Wayne, NJ 07470

KNOW THE CODE. Ask your local plumbing inspector if it is OK to bury Yellow Polyethylene Pipe WAL-RICH CORPORATION UNDERGROUND GAS PRODUCTS

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

TECHNICAL SPECIFICATION FOR LEVEL CONTROL VALVE HANDLING WATER

SECTION SUBMITTAL PROCEDURES

Vacuum Chucking on the Lathe

Transcription:

IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product acceptance by Authorities Having Jurisdiction. The most updated information on this Certificate of Listing is available online at pld.iapmo.org Effective Date: September 2017 Void After: September 2018 12630 West Airport Boulevard Suite #100 Sugar Land, TX 77478 Identification: Each length of pipe and each fitting shall be plainly marked with the country of origin, the manufacturer's name or the manufacturer's registered trademark by which the manufacturer can be readily identified after installation and any appropriate collective mark (optional). The marking shall be adequate identification of the manufacturer of the pipe and fittings if it readily identifies the manufacturer to the end user of the product. Markings shall be cast on fittings. Pipe markings: The pipe shall be marked continuously on the barrel with a minimum of 0.75 inch (19mm) lettering starting within 3 inches of each end of the pipe. Each pipe shall be marked with the date of manufacture. The marking shall be stenciled on the pipe or otherwise applied so as to be clear and legible. Fitting markings: The marking shall be cast with raised letters that are not to be located within the "W" dimension. Cast markings shall be raised from the wall of the fitting unless otherwise noted. Listed products shall bear the UPC certification mark. Characteristics: Installed fittings and pipe must be IAPMO R&T listed and installed in accordance with the requirements of the latest edition of the Uniform This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing. Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc. Any alteration of this certificate could be grounds for revocation of the listing. This document shall be reproduced in its entirety.

Plumbing Code Products listed on this certificate have been tested by an IAPMO R&T recognized laboratory. This recognition has been granted based upon the laboratory's compliance to the applicable requirements of ISO/IEC 17025. Products are in compliance with the following code(s): Uniform Plumbing Code (UPC ) International Plumbing Code (IPC ) Products are in compliance with the following standard(s): ASTM A888-2015 (excluding Annex A1)

MODELS: NO-HUB CAST IRON PIPE: 156 1-1/2" 158 2" 160 3" 162 4" 164 5" 168 6" 170 8" 171 10" 172 12" 173 15" NO-HUB FITTINGS: Short Sweep (MS) Long Sweep 462 2" 492 1-1/2" 464 3" 494 2" 468 4" 496 3" 470 5" 498 4" 472 6" 474 8" 475 10" 1/4 Bend W/2" Heel Opening 476 12" 477 15" 275 3" x 2" 280 3" x 2" 282 4" x 2" 1/4 Bend Reducing 218 4" x 3" 1/16 Bend San Tee (TY) 676 1-1/2" 806 1-1/2" 678 2" 808 2" x 1-1/2" 680 3" 810 2" 682 4" 812 3" x 1-1/2" 684 5" 814 3" x 2" 686 6" 816 3" Page 3 of 7

688 8" 818 4" x 2" 618 12" 820 4" x 3" 619 15" 822 4" 824 5" x 2" 826 5" x 3" 1/4 Bend 828 5" x 4" 830 5" 832 6" x 2" 188 1-1/2" 834 6" x 4" 190 2" 835 6" x 5" 192 3" 836 6" 194 4" 838 6" x 3" 196 5" 840 8" 198 6" 842 8" x 6" 200 8" 844 8" x 5" 846 8" x 4" 848 8" x 3" Double 1/4 Bend Long 1/4 Bend 402 2" (vent only) 404 3" (vent only) 406 4" (vent only) 425 2" x 18" Tapped 1/4 Bend 1/5 Bend 324 1-1/2" x 1-1/2" 536 2" 328 2" x 1-1/2" 538 3" 330 2" x 2" 540 4" 1/6 Bend 1/8 Bend 570 2" 604 1-1/2" 572 3" 606 2" 574 4" 608 3" 610 4" 612 5" San Cross 614 6" 616 8" 617 10" 1850 1-1/2" (vent only) 1852 2" (vent only) 1856 3" (vent only) San Tap Cross 1854 3" x 2" (vent only) 1862 4" (vent only) Page 4 of 7

1858 4" x 2" (vent only) 2012 1-1/2" x 1-1/2" (vent only) 1860 4" x 3" (vent only) 2014 2" x 1-1/4" (vent only) 1867 6" (vent only) 2016 2" x 1-1/2" (vent only) 1864 6" x 4" (vent only) 2018 2" x 2" (vent only) 1874 8" x 4" (vent only) 2022 3" x 1-1/2" (vent only) 2024 3" x 2" (vent only) Test Tee San Tap Tee (Tap TY) 2046 2" 2048 3" 1208 1-1/2" x 1-1/4" 2050 4" 1210 1-1/2" x 1-1/2" 2052 5" 1216 2" 2054 6" 1214 2" x 1-1/2" 2056 8" 1212 2" x 1-1/4" 2058 10" 1223 3" 1220 3" x 1-1/2" 1222 3" x 2" Iron Body Cleanout-Tapped 1226 4" x 1-1/2" 1228 4" x 2" 8570 6" x 5" Wye Combination Wye and 1/8 Bend 1312 1-1/2" 1694 1-1/2" 1314 2" 1698 2" 1316 3" x 2" 1696 2" x 1-1/2" 1318 3" 1700 3" x 2" 1320 4" x 2" 1702 3" 1322 4" x 3" 1704 4" x 2" 1324 4" 1706 4" x 3" 1332 5" 1708 4" 1326 5" x 2" 1716 5" 1328 5" x 3" 1710 5" x 2" 1330 5" x 4" 1712 5" x 3" 1342 6" 1714 5" x 4" 1334 6" x 2" 1718 6" x 2" 1336 6" x 3" 1720 6" x 3" 1338 6" x 4" 1722 6" x 4" 1340 6" x 5" 1724 6" x 5" 1354 8" 1726 6" 1344 8" x 2" 1734 8" 1346 8" x 3" 1728 8" x 4" 1348 8" x 4" 1730 8" x 5" 1350 8" x 5" 1732 8" x 6" 1352 8" x 6" Page 5 of 7

1361 10" 1357 10" x 4" Blind Plug 1359 10" x 6" 1360 10" x 8" 1362 12" 2480 1-1/2" 1363 15" 2482 2" 2484 3" 2486 4" Upright Wye 2488 5" 2490 6" 2492 8" 1646 2" 2494 10" 1648 3" x 2" 2495 12" 1650 3" 2496 15" 1652 4" x 2" 1654 4" x 3" Short Reducer Combination Wye and 1/8 Bend, Double 2138 2" x 1-1/2" 1802 2" 2140 3" x 2" 1806 3" 2142 4" x 2" 1804 3" x 2" 2144 4" x 3" 1812 4" 2146 5" x 2" 1808 4" x 2" 2148 5" x 3" 2150 5" x 4" 2152 6" x 2" Closet Bend Reducing 2154 6" x 3" 2156 6" x 4" 2158 6" x 5" 2832 3" x 4" x 6" x 12" 2160 8" x 2" 2840 3" x 4" x 6" x 15" 2162 8" x 3" 2842 3" x 4" x 6" x 16" 2164 8" x 4" 2852 3" x 4" x 10" x 12" 2166 8" x 5" 2866 3" x 4" x 16" x 16" 2168 8" x 6" 2172 10" x 4" 2174 10" x 6" Closet Bend 2175 10" x 8" 2176 12" x 4" 2177 12" x 6" 2904 4" x 4" x 6" x 12" 2178 12" x 8" 5572 4" x 10" x 15" 2179 12" x 10" 5572 4" x 4" x 10" x 15" 2180 15" x 4" 2181 15" x 6" 2182 15" x 8" Closet Flange Riser 2183 15" x 10" Page 6 of 7

2184 15" x 12" 2966 4" x 3" x 3-1/2" P-Trap Figure Five 2506 1-1/2" 2508 2" 8052 2" 2510 3" 8054 3" x 2" x 3" x 3" 2512 4" 8062 4" 2514 6" Cleanout Ferrule (I.B.C.O.) P-Trap with Primer 8564 3" x 2 1/2" 8530 2" 8566 4" x 3 1/2" 8532 3" 8534 4" Tapped Adaptors P-Trap with Tapped Inlet 2242 2" x 1-1/2" 2244 2" x 2" 2582 1-1/2" x 1-1/2" 2586 2" x 1-1/2" 2588 2" x 2" Closet Flange Double Wye 9426 4" x 2" 1538 2" Deep Seal P-Trap 1542 3" 1540 3" x 2" 1548 4" 2564 2" 1544 4" x 2" 2566 3" 1546 4" x 3" 2567 4" 1552 6" x 4" 1554 6" 1557 8" x 6" 1558 8" *Models on this listing may be preceded by the prefix ZFB to denote optional epoxy coating Page 7 of 7