MAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION

Similar documents
MAGTROL. LMU 112 and LMU 117 Load Monitoring Units. LMU 112 / LMU 117 Data Sheet LMU 112 FEATURES LMU 117 FEATURES DESCRIPTION SYSTEM CONFIGURATION

MAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features

Load Monitoring Units. LMU 212 and LMU 217. User s manual

LOAD MONITORING UNIT LMU 116 VERSIONS 02X AND 02XC

Load Monitoring Unit LMU 216. User s manual

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS

MAGTROL. KLB Wedge socket. KLB/KLE/KLU Data Sheet SYSTEM CONFIGURATION

TSC 401 Torque/Speed Conditioner

SIGNAL CONVERTER I/V AND I/I CST 113

MAGTROL. DI Series Displacement Transducers. DI Data Sheet. Features

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS.

LS 120 and ILS 730. Air-gap measuring system LS 120 transducer and ILS 730 signal conditioner

IPC 704. Signal Conditioner Type IPC 704. U / I output DATA SHEET FEATURES

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

SE 120. Piezoresistive accelerometer

Type CP-S, CP-C & CP-A Switch mode

DP2000 ORDERING GUIDE To Order MODEL NO.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

MODEL AT-10 ANALOG TRANSMITTER

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

DMS Insert Module MSR 282

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electromagnetic flowmeters and switches DWM 1000/2000

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

WS12EX Position Sensor with Analog output Dust explosion-proof

FC Series Signal Conditioners

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Proximity Sensor Terminology

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CE620. Piezoelectric accelerometer with integrated electronics. IECEx

CAN-IO Custom IO remote module

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Economical Digital Indicators For Process and Electrical Measurement

Differential Charge Amplifier

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

IPC 704. Signal conditioner FEATURES. For CA piezoelectric accelerometers and CP dynamic pressure transducers

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Vibration amplifier Model 6634C

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

ZITARES LCS Non-SELV, Constant current control gear, 1-channel, non-dimmable

DOCUMENTATION. Its affordable price allows you to meet your budget target.

08/07/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

ISOMETER IRDH575. Approvals

08/07/2015

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

DIGEM f 96 x 48 EK. Applications. Description

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

20 General technical data XI/ON

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

MAGTROL. KLB Wedge socket. KLB/KLE/KLU Data Sheet SYSTEM CONFIGURATION

GEMINI 1000/ DIGIT PRESETTABLE COUNTERS OR RATE INDICATORS GEMINI SINGLE LEVEL & GEMINI DUAL LEVEL w/optional 20 ma CURRENT LOOP

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Three-phase monitoring relay CM-PFS

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

02/11/2015

Digital flow transmitter for continuous flow measurement

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Adjustable Digital Process Instrument MDK480

high grade, temperature resistant plastic, Thermoplast with brass inserts

AXICOM Telecom-, Signal and RF Relays. D2n V23105 Relay Nov. 07 Rev A ECOC: JM10

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Modicon Momentum automation platform 0

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

CMC 256plus - protection relay test set and universal calibrator

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

P1-04ADL-2 Analog Input

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

Zelio Control Measurement Relays

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transcription:

Data Sheet Load Monitoring Unit FEATURES For Use with Full-bridge Strain Gauge Transducers (Sensitivity 0.5 to 2 mv/v) Voltage Input for Different Charge Summation Summer with 4 Inputs Taring Facility 4 Level Detectors with Relay Output Contacts including 2 with Programmable Memory 0 to 20 ma DC Current Output Three ±10 V Voltage Outputs Provides Continuous Detection of Signal Line Failure and Short Circuits Compatible to CE Standards IP 66 Aluminium Housing DESCRIPTION The Magtrol LMU Load Monitoring Unit is specially designed for strain gauge transducer applications. It is flexible and fully configurable due to DIP-switches and jumpers which allow the unit to be easily installed no solder connections are required. The contains 1 full-bridge strain gauge transducer input, 1 voltage input, 4 level detectors (output contacts, 2 with programmable memory), 1 current output, 3 voltage outputs and 2 OK self-test signals for monitoring the correct operation while running several LMU units simultaneously. The level detectors and the outputs can be dedicated either to the full-bridge input, to the voltage input or to the sum of The is used with Magtrol Load Measuring Pins which measure load and force and provide overload protection. Magtrol also offers a wide range of Load-Force-Weight Transducers in various executions and accuracy classes and our Digital Process Monitors/Signal Conditioners measure and display load, force and weight from signals generated by strain gauge transducers. both (see Application Selection at bottom of page 2). A built-in self-test system detects any short circuits or signal line failures, thus allowing the system to be used in applications where safety is important. If a problem is detected, both relays are deactivated and the output voltage (respective current) changes to >10 VDC (>20 ma). The LMU is fully compatible with European Community (CE) standards. Its IP 66 aluminium housing allows the system to be used in harsh environments. Using SMD (surface mounted device) technology, the LMU allows the maximum performance/price ratio for strain gauge transducer monitoring. SYSTEM CONFIGURATION Summer with 4 Voltage Inputs (±10 V) Strain Gauge Transducer Voltage Input ±10 V "OK" Input (OK I/P) Power Supply 115 / 230 VAC (50/60 Hz) OR 20 to 32 VDC Output Contacts of Relay RE1 Output Contacts of Relay RE2 Output Contacts of Relay RE3 Output Contacts of Relay RE4 "OK" Output (OK O/P) Current Output 0 to 20 ma 3 Voltage Outputs ±10 V 1 www.magtrol.com

Specifications * Refer to NOTE on following page. 2 INPUT CHARACTERISTICS Power Supply Voltage Maximum Current Bridge Signal Supply Voltage Max. Possible Current Sensitivity Max. Dynamic Component of Bridge Signal Max. Common Mode Voltage on Input 115/230 VAC (50/60 Hz) or 20 to 32 VDC, jumper selectable Current Fuse Rating 70 ma for 230 VAC 80 mat 150 ma for 115 VAC 160 mat 250 ma for 20 VDC 400 mat 10 VDC 150 ma DC 0.5 to 2 mv/v ±30 mv DC ±10 V Voltage Input for Summation of Another Load Input Impedance Max. Input Signal (dynamic) 200 kω ±10 V Input for Self-Test Feature (OK I/P) Type OUTPUT CHARACTERISTICS Relay Outputs Active if short circuited Number 2 (RE 1; RE 2) Normal State Max. Current per Contact Max. Voltage per Contact Max. Break Power Insulation Voltage Lifetime Contact Resistance Current Output Output Type Nominal Current Range Max. Current Range Max. Load Output Impedance Voltage Output Max. Value Max. Load Output Impedance Normally energized 5 A continuous / break 20 A on startup AC: 250 V rms DC: 350 VDC 100 W or 1000 VA Contact-Contact: 750 V rms Contact-Coil: 1.5 kv rms > 2 10 8 switchings < 20 mω Current generator 0 to 20 ma DC 0 to 25 ma DC < 500 Ω for I max = 20 ma > 50 kω ±10 V FSD 10 kω(ε 1%)[ 2 kω(ε 5%)]* 100 Ω (in series) Output for Self-Test Feature (OK O/P) Type Open collector (short circuit-proof) TRANSFER CHARACTERISTICS Voltage Transfer Ranges ( U I/P / U O/P ) Range 1 2 3 Bridge Sensitivity [mv/v] 0.42 to 0.78 (0.6) 0.7 to 1.3 (1) 1.2 to 2.2 (1.7) Voltage Transfer (gain) 2380 to 1280 (1670) 1428 to 769 (1000) 833 to 455 (588) Adjustment Range ±30% ±30% ±30% Range Selection Zero Adjustment for Measuring Chain Using DIP-switches Coarse adjustment using multiturn potentiometer: equivalent to ± 10 V/output for Range 3 Fine adjustment using multiturn potentiometer: 5% of the coarse adjustment Temperature Drift of Transfer Function 200 ppm/ C Temperature Drift of 0 200 ppm of FSD/ C for range 0.5 mv/v 1 µv/ C Current Transfer Range Sensitivity Range with Multi-turn Potentiometer ± 20% of FSD on U O/P Nominal Current Range 0 to 20 ma DC Max. Current Range 0 to 25 ma DC Zero Adjustment Range ± 5 ma DC for I O/P 5 ma DC Selectable Low-Pass Filter Filter Type Butterworth Filter Order 2nd -3dB Cut-off Frequency Selectable using DIP-switches to 0.3 Hz; 1 Hz; 3 Hz; 10 Hz Transfer Function Between Summing Input/ 1 Voltage Output Level Detectors Number of Detectors 2 (REL1; REL2) -10 to +10 VDC using multi-turn Level Adjustment Range potentiometer (measured on voltage output) Hysteresis 0 or 5% (selectable using DIP- switches) Detection Indication < or > (selectable using DIP-switches) Switching Delay Number of Circuits 2 Delay Adjustment Range 0 to 5 seconds using multi-turn potentiometer Application Selection Selection Det. REL1 Det. REL2 U O/P, I O/P 1 A A A 2 A + B A A + B 3 A A + B A 4 A + B A + B A + B 5 B B B 6 A + B B A + B A = Bridge signal; B = Voltage input

Specifications MECHANICAL CHARACTERISTICS Housing Material Weight Aluminum 3 kg; 6.61 lb Stuffing Glands Number and Type 6 PG 11 Material Nickel-plated brass Terminal Strip MK8 (screw at 45 and Type connection at 45 ) Max. Area of Connecting Wire AWG 20 to 16 Cross-section: 0.5 to 1.5 mm² ( 0.00077 to 0.0023 in²) ENVIRONMENTAL CHARACTERISTICS Operating Temperature -40 C to +80 C Storage Temperature -45 C to +85 C Protection Class IP 66 Vibration and Shock According to IEC 68.2 According to EN-58081-2 EMC (Generic Emission Standard) and EN-58082-2 (Generic Immunity Standard) * NOTE: In order to guarantee a precise calibration, the customer is asked to indicate the impedances of the connected unit together with the order. If this value is unknown, an impedance of 1 MΩ will be used for calibration. The resulting deviation will be in the order of 5% with an impedance of 2 kω or 1% with 10 kω. MONITORING MODULE SPECIFICATIONS SUMMER Number of Inputs Input Voltage Output Voltage LEVEL DETECTOR Number of Detectors Level Adjustment Range Hysteresis Direction Indication 4 (UA, UB, UC and UD) ±10 V UE1 = (UA + UB ± UC ± UD)X factor X adjustable between 0.25 and 10 2 (REL3, REL4) ±10 VDC using multi-turn potentiometer (measured on voltage output) 0 or 5% (selectable using DIP-switches) < or > (selectable using DIP-switches) SWITCHING DELAY Number of Circuits 2 Delay Adjustment Range 0 to 5 s, using multi-turn potentiometer RELAY OUTPUT MEMORIZATION (LATCH) Control Using DIP-switches Reset Signal RESET REL3, RESET REL4 TARING CIRCUIT Volatile digital 12-bit memory* (reset when the unit is switched on), the stored digital value is subtracted Principle from the D/A converted input signal. Resolution Storing Time Output Impedence Acceptable Load Resistance * Current interruptions lasting for less than 30 ms do not cause the loss of the stored tare value. 1/4096 of the selected range < 2 s < 200 Ω 20 kω CONFIGURATION The Load Monitoring Unit offers unlimited configuration possibilities. It is impossible to list them all in this data sheet. Please contact Magtrol or one of its subsidiaries or sales agents to discuss your specific applications. 3

Configuration and Calibration Report Drawing continued on page 5 P/N : 224-116-000-02X S/N : 4

Configuration and Calibration Report Drawing continued on page 4 CONFIGURATION AND CALIBRATION REPORT FOR VERS. 02X DWG. Nr. : SWITZERLAND PZ 6570 5

C E R TIFIC A TI O N Dimensions and Ordering Information DIMENSIONS Stuffing Glands (PG 11 max.) Ø cable: 5 to 12 mm ( 0.20" to 0.47") K M UUU UUU H J N N P P P N N FRONT VIEW Mounting Screw M6 30 SIDE VIEW F C E D B A OVERHEAD VIEW Sealed Diecast Aluminum Box - Protection Class IP 66 NOTE: Original dimensions are in Metric units. Dimensions converted to English units have been rounded up to 2 decimal places. mm in A 287 11.30 B 272 10.71 C 190 7.48 D 175 6.89 E 18 0.71 F 220 8.66 H 12 0.47 J 10 0.39 K 90 3.54 M 27 1.06 N 30 1.18 P 35 1.38 LMU116DS-US www 03/04 ORDERING INFORMATION LOAD MEASURING UNIT P/N 224-116-000-0 Includes balancing comparator sub-module? No 21 Yes 61 Includes setup and calibration? No, standard module with no setup and no calibration Yes, according to the configuration and calibration report PZ 6570 (To be filled in according to the application) (blank) C Due to the continual development of our products, we reserve the right to modify specifications without forewarning. www.magtrol.com INC 70 Gardenville Parkway Buffalo, New York 14224 USA Phone: +1 716 668 5555 Fax: +1 716 668 8705 E-mail: magtrol@magtrol.com SA Route de Moncor 4B 1701 Fribourg, Switzerland Phone: +41 (0)26 407 3000 Fax: +41 (0)26 407 3001 E-mail: magtrol@magtrol.ch Subsidiaries in: Germany France Great Britain Worldwide Network of Sales Agents Magtrol SA ISO 9001:2000 certified ISO 9001 SWISS