Specifications subject to change without notice Heartbeat of the Smart Grid

Similar documents
GPS Satellite-Controlled Clock

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

Model 1133A Power Sentinel. with. Digital Signal Analysis SYNCHRONIZED POWER QUALITY/REVENUE STANDARDS

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

[ tima-datasheet-en v11.1 ]

Reason RT430/RT434. GE Grid Solutions. GNSS Precision-Time Clocks. Precise Time Synchronization. Flexible Design. Hardened for Industry.

satech SynchroStar GPS 200 Series

Your benefits using DTS 4160.grandmaster:

Enabling Tomorrow s Technology Today

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

T200, PTP/IEEE 1588 Grandmaster Clock and

DTS 4210.timecenter. Swiss Time Systems. High precision time server, grandmaster and PRC

Your benefits using DTS 4160.grandmaster:

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

T108, GPS/GLONASS/BEIDOU Time Server

MODEL 1205B/C MODEL 1206B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

SEL-2488 Satellite-Synchronized Network Clock

GPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard

MODEL 1201B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

MODEL 1202B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

120W UHF Transmitter/Repeater

GPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards

LANTIME Network Time Servers

ExacTime GPS Time & Frequency Generator

Utility Communications Teleprotection Equipment TPT-200

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

GPS Time and Frequency Reference Receiver

Digital Instruments S.r.l. GPS-MXS. Multireference Time-Frequency

Side view View from below Rear view

Reason RT412. Technical Manual. Optical Transceiver. Platform Hardware Version: A Publication Reference: RT412-TM-EN-2

Model NV-ER1808i TBus Eight Port Receiver Hub

PYRAMID 915MHZ WIRELESS RF TRANSMITTER & REPEATER USER GUIDE. Table of Contents. Overview Installation Setup Specifications...

CMC 256plus - protection relay test set and universal calibrator


Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

NTS-6002 VERSION 11 HARDWARE MANUAL

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT

SyncBox/N2X: Converts NTP or IEEE-1588 to IRIG, 10MHz, PPS, DCF77 and serial time telegrams

SWT 3000 Teleprotection technical data siemens.com

REFERENCES BASE BDR_UK-V5.1

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

MATERIAL SPECIFICATIONS FOR WIRELESS LINK

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

IRIG-B Interface (De-modulated) External clock synchronization signal IRIG format B00X

R40 Mk III AIS Base Station

R&S OSP Open Switch and Control Platform Specifications

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Mini Compact Outdoor GaN SSPAs in C-, X-, and Ku-Bands

Model NV-ER1816i TBus Sixteen Port Receiver Hub

Model 931A Power System Analyzer. Model 930A Three Phase Power Analyzer. Model 929A Three Phase Power Meter. with. Digital Signal Analysis

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Saitel DP. Technical Specifications Tables. The high-performance platform for applications of control and automation. July 2014

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

SyncServer S650 Accurate, Secure, and Flexible Time and Frequency Standard

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

10/100 PoE+ NV-ER1808i or. NV-ER1816i

Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE

MODEL 1083A SATELLITE-CONTROLLED FREQUENCY STANDARD

ONCORE ENGINEERING NOTE M12 Oncore

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

MODEL 1083B SATELLITE-CONTROLLED FREQUENCY STANDARD / COMPARATOR

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

R&S OSP Open Switch and Control Platform Specifications

NI PXI-2521 Specifications 40-Channel DPST Relay Module

100 BaseT transmission; Network speeds up to 93 Mbps*; Up to 8,000ft (2,500m)*

Model NV-EC1701U Eo2 TM Ethernet over 2-Wire Transceiver with PoE, PoE+, or High Power PoE

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Installing the IPS 4240 and the IPS 4255

Power Matters. Time Interfaces. Adam Wertheimer Applications Engineer. 03 November Microsemi Corporation.

NV-ET1801 or NV-ER1808i or. NV-ER1816i

125 Series FTS375 Disciplined Reference and Synchronous Clock Generator

MN5020HS Smart GPS Antenna Module

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Surge Generator for MIL-STD 1275

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

2520 Pulsed Laser Diode Test System

XLi. Time and Frequency System. Key Features

NI PXI-2530 Specifications

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

J kw AM Transmitter

APPH6040B / APPH20G-B Specification V2.0

Model 865 RF / Ultra Low Noise Microwave Signal Generator

N432A Thermistor Power Meter DATA SHEET

Compact Outdoor Solid State Power Amplifiers in S-, C-, X-, and Ku-Bands

EM 6000 EM 6000 DANTE True bit diversity receiver

DOBLE F6150SV TECHNICAL SPECIFICATIONS

GFT Channel Digital Delay Generator

Modular Controller. Key Features. Model Complete system controller for 8 channel applications; EDFA pumping or DWDM signal sources

Arbitrary/Function Waveform Generators 4075B Series

Transcription:

Model 1151B Network Clock Preliminary, April 2013 Specifications subject to change without notice Heartbeat of the Smart Grid TM Clock defines a new generation of advanced timing devices, becoming the Heartbeat of the Smart GridTM. Features include a modern user interface, network capabilities and an all new modular design allowing the user to customize the configuration to meet all of their grid timing needs. Interface Clock comes standard with three independent Ethernet ports (10/100 Mb/s) with RJ 45 or optional fiber connectors. Configuration and status information are available via a web interface or SSH console. Designed with security in mind, suitable encryption, authentication, validation and password access restrictions help you to meet NERC Critical Infrastructure Protection (CIP) standards. Primary and Backup Timing References Primarily intended to use GPS as a source of time, the Model 1151B Network Clock also offers Galileo and GLONASS receivers as well as internal high precision holdover oscillators. Other clocks in the same substation using IRIG B, IEEE 1588 (PTP), NTP or SNTP may also be used for backup and redundancy. Clock continually provides an estimate of its accuracy. Real time information about the status of each available time source can be provided and alarms are generated when any timing sources are lost, impaired or compromised. Modular Design Capable of being custom tailored to each user's needs, the Arbiter Systems, Inc. Model 1151B Network Clock takes advantage of four module slots. Two of the four modules are a power supply/receiver module and a network module. The other two slots can be equipped with a legacy input/output module, configurable output module, a second power supply/receiver module or a second network module. Custom modules may be available for a nominal NRE fee. PD0047800B 1

Modular Configuration Four slots, user configurable. Minimum of one Power/Receiver module and one Network module required. Additional modules are optional and can be duplicated for redundancy. Power/Receiver Module The Power/Receiver module comes standard with an universal power supply that accepts inlet power from 85 to 264 Vac (47 440 Hz) or from 110 to 350 Vdc at less than 30 Watts. In addition to providing power, this module is equipped with a receiver for synchronizing time, by default GPS but optionally can be Galileo or GLONASS satellite systems. Optional high performance oscillators are also available on this module. GPS Timing Accuracy Specifications apply at an output set for 1 PPS. UTC/USNO ±50 ns rms, when receiving 4 or more satellites and Position Hold Mode on GPS Synchronization Analog and time code output signals are synchronized to internal 1 PPS, ±50 ns, maximum. IRIG B modulated, ±1 μs, maximum (S)NTP, ±100 μs, maximum PTP/IEEE 1588, ±50 ns, maximum The leading edge of the start bit of a received RS 232 data message may be selected to trigger the Event A input, providing synchronization with 100 ns resolution. GPS Position Accuracy 10 meters, rms, 90% confidence 2 Power/Receiver Module (Continued) GPS Satellite Tracking Twelve (12) channel, GPS L1, C/A code (1575.42 MHz). Receiver simultaneously tracks up to twelve satellites. Results from all tracked satellites are averaged in Position Hold Mode or, with Position Hold Mode off, using least squares estimation. GPS Acquisition 150 seconds typical, cold start 15 minutes, 90% confidence, cold start 40 seconds, typical, with almanac < 1 month old 15 seconds, typical, with ephemeris < 4 hours old The GPS Data Backup Battery is included in the Model 1151B. This feature improves acquisition time by supplying constant power to the real time clock and RAM in the GPS receiver module. If almanac, ephemeris and time are provided via network connections, acquisition will be completed in less than 15 seconds. Optional Receivers GPS GLONASS Galileo (TBD) Network Module The Network Module is the communications interface for the Model 1151B, all configuration is performed over one of the Ethernet Ports (3 provided) using the web interface or the SSH console. The three ports are independently configured and can be either copper 10/100 BaseT connectors or fiber optic connectors (SFF). One digital input and output and one analog input and output are also included. The digital input may be used as an event timer, while the analog input may be used to monitor frequency.

Network Module (Continued) Input / Output Ethernet PTP (IEEE 1588), NTP, SNTP, ICMP, Protocols SNMP, TCP, SSH, SCP, SSL, HTTP, HTTPS, DHCP Analog Input 50 or 60 Hz: 5 to 120 Vrms Digital Input Event or 1 PPS: 5 V to 85 V Analog Output IRIG B, 1 khz modulated, 4 Vp p Digital Outputs IRIG B, E, D, or H, DC level shift 5 V CMOS 1 PPS, 1 PPM, 1 PPH Programmable Pulse IRIG B modified Manchester (IEEE Standard 1344) Legacy Input/Output Module General Input/Output Module Provides four slots offering the following capabilities; contact Arbiter Systems for more information. Isolated outputs provide > 3750 Vrms barrier isolation and meet 300 V CAT III creepage and clearance or better (*600 V CAT III) Dual High Drive timing outputs, standard or isolated Modulated IRIG B12x output, standard or isolated High Frequency Digital/Clock output, dc to 100 MHz, standard or isolated Sinewave Frequency output, 100 khz to 100 MHz, standard or isolated Fiber Optic Output or Input, type ST 820 nm *Armature or Solid State Relay, 1 Form C changeover *Isolated Digital (event, IRIG/1PPS) input UART (serial) port, standard or isolated Interface Front Panel Display Functions The Legacy Input/Output (LIO) module provides many of the standard functions common to existing Arbiter clocks, thereby making these legacy features available. By installing the LIO module in the network clock the following standard clock functions are immediately available: eight high drive timing outputs, one modulated IRIG B (analog) timing output, two RS 232 multifunction serial ports, one RS 485 multifunction serial port, one set of SPDT multifunction relay contacts, event input measurement, wide input voltage, and an analog line frequency measurement. All of these signals are accessible via the 48 pin high density connector. Holdover Oscillators Two versions, providing 10 μs/day or 1 ms/day guaranteed holdover (typically 5 to 10 times better). Standard performance is < 50 ms/day. LEDs Keyboard System Ethernet 192 x 32 graphic LCD Time: UTC or local Position: latitude, longitude, altitude Receiver and clock status 1 PPS (input) deviation Event time Operate Time Source Time Quality User Configurable 1 User Configurable 2 User Configurable 3 User Configurable 4 Eight keys Web Interface Configuration SSH Console Configuration 3

Power Requirements General Physical Size 1 RU rack mount or tabletop; 280 mm deep FMS. Rack mounts included. 508 x 381 x 203 mm (20 x 15 x 8 in.), shipping Weight 2.27 kg (5 lbs), net 6.8 kg (15 lbs), shipping Antenna 0.75 in. pipe (1 in. 14 marine) thread Cable Connection: F type Size: 77.5 dia. x 66.2 mm (3.05 x 2.61 in.) Weight: 170 grams (6.0 oz) Antenna Cable RG 6 type, 15 m (50 ft) provided Weight: 0.69 kg (1.52 lbs) per 15 m Environmental Temperature Operating: 10 to +65 C ( 20 to +70 C typical) Nonoperating: 40 to +75 C Humidity Noncondensing EMC Radiated susceptibility: passes walkie talkie test Conducted emissions: power supply complies with FCC 20780, Class A and VDE 0871/6.78 Class A Surge withstand capability (SWC), power inlet: designed to meet ANSI/IEEE C37.90 1 and IEC 801 4 Modules There are four module slots in the Model 1151B. Two of the module slots require the network module and the power module. The two open slots can be filled with any of the modules listed below. Only one module may occupy an individual Module Slot. I/O Legacy Input/Output Network Module with 3 Port Switch General Input/Output (up 4 outputs) Power Terminal Power Strip with GPS receiver 85 to 264 Vac, 110 to 370 Vdc 4 Standard Voltage Inlet 85 to 264 Vac, 47 to 440 Hz, 40 VA max. or 110 to 350 Vdc, 30 W maximum Terminal Strip, 5 mm Holdover Oscillator and Timing OCXO < 1 ms/day OCXO < 10 μs/day TCXO < 50 ms/day Standard Accessories Included GPS Antenna, pipe mountable 15 m (50 ft) RG 6 Antenna Cable 19 in. Rack Mount Kit Operation Manual Power Cord Available 15 m (50 ft) RG 6 Antenna Cable 30 m (100 ft) RG 6 Antenna Cable 45 m (150 ft) RG 6 Antenna Cable 60 m (200 ft) RG 6 Antenna Cable 75 m (250 ft) RG 6 Antenna Cable GPS Antenna Mounting Kit 21 db In Line Preamplifier Antenna Grounding Block Kit GPS Surge Protector GPS Antenna Cable Splitter BNC (Male) Breakout to 100 mm Wires BNC (Female) Breakout to 100 mm Wires 300 m (1000 ft) Roll RG 6 Cable RG 6 Stripping Tool RG 6 Type F Crimp Tool RG 6 Type F Male Crimp on Connector AS0087800 CA0021315 AS0094800 PD0043900 CA0021315 CA0021330 CA0021345 CA0021360 CA0021375 AS0044600 AS0044700 AS0048900 AS0094500 AP0013400 AP0003400 AP0008900 WC0005000 TF0013200 TF0006400 CN0027700

Accessories (Continued) 300 m (1000 ft) Roll RG 11 Cable RG 11 Stripping Tool RG 11 Type F Crimp Tool RG 11 Type F Male Crimp on Connector WC0004900 TF0013300 TF0006000 CN0027800 Optional equipment may be shown. 5