phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

Similar documents
MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401

ph or ORP Transmitter

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

Signet 2750 DryLoc ph/orp Sensor Electronics

Digital conductivity transmitter

OPTISENS PH 8390 Technical Datasheet

OPTISENS ORP 8590 Technical Datasheet

Signet ph/orp Electrodes General Purpose

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

SMARTPAT PH 1590 Technical Datasheet

Bulb ph and ORP Electrodes

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

Key Number I II III IV V _ - - _ - - _ - _, _,

Signet ph/orp Electrodes

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS21 and CLS21D

Digital ORP sensor for the water and wastewater industry

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Open Channel Flowmeter 713

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

The transducer component converts the measured signal and displays the actual value.

Multi-Electrode Mounting (used for ph, Orp and Specific Ion) Honeywell Proprietary

Conductivity Transmitter

Model Q40CT. System Features. Toroidal Conductivity Monitor...

ph/orp Measurement OPM223/253

Electromagnetic Flow Transmitter

Non-Submersible Industrial Pressure Transducer

Digital inductive conductivity transmitter

SMARTPAT ORP 8510 Technical Datasheet

ph / ORP Measurement mypro CPM 431

inc Channel 1 ph, ORP (Redox) Conductivity or Dissolved Oxygen Transmitter Channel 2 Temperature Transmitter Black (V-) Green (V-)

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Condumax CLS21 and CLS21D

ORP100 Sensor. Edition 1.0. User Manual

Condumax W CLS15 and CLS15D

Measuring and Controlling Unit Multronic OC

Condumax CLS15 and CLS15D

General Specifications

OPTISENS PH ph sensor. Technical Datasheet

E l e c t r o m a g n e t i c f l o w m e t e r s

SMARTPAT COND 1200 Technical Datasheet

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Rosemount TM 498CL ph-independent Free Chlorine Sensor

TECHNICAL DATA ELECTRO CHEMISTRY DIFFERENTIAL PH AND ORP. phd sc Digital Diferrential PH and ORP Sensors

OPTISENS PH 8100 Technical Datasheet

Series 7777 Meredian II Electrode In-Line or Immersion Mounting

Condumax CLS15 and CLS15D

LST400 Ultrasonic level / open channel flow transmitter

Memosens CPS96D. Technical Information

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

TUpH 396RVP and 398RVP Retractable ph/orp Sensors

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

ABB ph/orp analyzer and probe package

Measuring and Controlling Unit Multronic

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

ANALYTICAL - COMPLEXITY MADE SIMPLE

Signet 9900 Transmitter

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Technical Information Orbipore CPS91D and CPS91

HBPH-MK2 Brine/NH3 Leakage Sensor

OPTIFLUX 5000 Technical Datasheet

Rod probe With coaxial tube reference probe

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Isolated STs Series, 4-20 ma Dissolved Oxygen and Temperature transmitter for in-line or submersible applications Insertion (in-line)

DissolvedOxygenMonitor

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Ceramax CPS341D. Technical Information

Valve Island with Electronic I/O

Inductive conductivity transmitter JUMO CTI-Junior

Condumax W CLS15 and CLS15D

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Technical Information Condumax CLS21D/CLS21

1000TR. Instructions

General Specifications

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Signet 9900 Transmitter

Signet 9900 Transmitter

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Digital flow transmitter for continuous flow measurement

Conductivity measurement SmarTec S CLD 132

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Grundfos Direct Sensor

ProMinent D1Cb and D1Cc Analyzers

Process ph/orp Analysis Systems

Digital flow ELEMENT transmitter for continuous flow measurement

Flow Measurement SITRANS F M

Transcription:

PH, TEMPERATURE AND REDOX MEASUREMENT General The advanced and unique design of phix Compact ensures that your work is done fast, easy and with accuracy. The compact design offers a union in one end, and male thread in the other, this makes it easy to mount phix Compact in pipelines or open tanks. The double-junction electrode is especially developed for phix Compact and will provide significantly lower impedance, increased electrolyte volume, increased junction area and a longer lifetime compared to most traditional electrodes. Simple communication for setup, calibration, electrode diagnosis and troubleshooting. The electrode works well in waste water, drinking water, aqua culture and water with low ion concentration. Features Compact design electrode, fitting and transmitter in one Built-in temperature transmitter 4-20 ma output Unique and simple buffer adjustment Constructed in Glass reinforced PPS Automatic buffer sequence Very resistant to clogging Application Waste water outlet Waste water treatment Drinking water Raw water pipes Process water Aqua culture DATASHEET EN 4.10 PHIX DATASHEET 1812 4.10 phix Compact

Specifications phix Compact Power supply Input, ph and mv Input Impedance, ph Input Impedance and mv Accuracy ph Accuracy Temperature Linearity ph 2-wire supply, 12-30 V DC 0-14 ph / -1000...+ 1000 mv > 2 x 1012Ω > 2 x 1012Ω ± 0,01 ph / 1 mv ± 0,5 % FS ± 0,01 ph / 1 mv Linearity Temperature ± 0,2 % Repeatability ± 1,0 % Response Time ph Response Time Temperature Temperature Compensation Output approx. 10 seconds 95% in less than 60 seconds (when sensor is fully submerged) Built-in sensor, -20... +80 C / -4...+176 F 4-20 ma for ph / mv / temperature - Scaled:0-14 ph/ -1000...+1000mV / 0-50 C (32-122 F) Enclosure IP 68 Materials Temperature range Cable Length Weight Ryton (PPS) and stainless steel AISL316-20 +60 C / -4...+140 F 6 meter (19.7 ft) 1,8 kg / 3,97lb CE approvals EN61000-6-4 2007-02-19, EN61000-6-2 2005-09-08 Notice: phix Compact holds standard warranty, the changeable sensors are consumable, hence they hold a limited warranty Electrodes 160310 ph electrode 160311 ph electrode 160312 Redox/ORP electrode Membrane Glass Glass Platinum Reference System Ag/AgCL, 3.5M KCl Ag/AgCL, 3.5M KCl Pt/KCL, 3.5M KCl Reference system material PTFE PTFE PTFE Impedance 50 MΩ 50 MΩ n/a Measuring Range 0-14 ph 0-14 ph -1000 / +1000 mv Temperature Range 0-80 deg.c 0-80 deg.c 0-80 deg.c 0-Point ph 4,60 ph, +/- 0.2 ph 7,00 ph, +/- 0.2 ph n/a Response time t95-5 sec. t95-5 sec. t95-5 sec. Pressure 0-100 psig / 0-6,8 bar 0-100 psig / 0-6,8 bar 0-100 psig / 0-6,8 bar Dimensions mm & inch / 1,26 / 36,66 / 10,51 / 2,4 / 1,5 1,93 / 2,6 As our products are developed continously, we reserve the rigth to make any changes without prior notice.

Electrical Connections phix Compact has either 1 or 2 x 4-20 ma signal outputs, and the PUR cable will therefore have either 3 or 5 wires respectively: Nr.: Designation: Colour: Channel: 1 Shield (none) 2 + 12-30 V DC 1 Red ph or redox signal 3-4-20 ma 2 Black Output 1 4 + 12-30 V DC White ma_temp signal 5-4-20 ma Grå Output 2 ➀ ➁ ➂ ➀ ➁ ➂ ➃ ➄ Power Supply MJK Digital Indicator 531 Cable from phix Compact 230 VAC supply L N 12-30 VDC supply 4-20 ma signal Fittings 155268 ISO 155269 NPT Extension for universal bracket, order no. 200215 Pipe for submersion PVC Pipe ISO / NPT 50mm / 2 Wall bracket, order no. 200210 155246 ISO 155247 NPT Universal bracket, order no. 200205 1¼ RG (ISO 228-1)

Calibration and Correct Storage Electrodes are consumables; the lifetime of a ph electrode will vary depending on the ph value and temperature of the media in which it is submerged. The lifetime of the electrode is also depending on the electrode being kept moist when not in use. The optimal way of securing the electrode is to clean it thoroughly after use, and use the cap delivered with the electrode. To keep the electrode moist a KCL solution must be used in the cap, with cotton ball, sponge, paper or simply fill the cap. Fittings mm & Inch 2,83 Liquids ph Buffer fluid, ph values 4, 7 and 10 for calibration KCI fluid, to keep the cotton or sponge inlay moist, this lengthen the lifetime of the electrodes

Order Numbers phix Compact ph Transmitter, w/o electrode 203105 phix Compact ph transmitter without electrode 203105-7 phix Compact ph/mv transmitter, ISO thread, 0=7.0pH, w/o electrode 203106 phix Compact ph transmitter, NPT thread 0=4.6pH, w/o electrode 203106-7 phix Compact ph transmitter, NPT thread 0=7.0pH, w/o electrode phix Compact ph and temperature Transmitter, w/o electrode 203107 phix Compact ph and temperature transmitter without electrode 203107-7 phix Compact ph and temperature, ISO thread, 0=7.0pH, w/o electrode 203108 phix Compact ph and temperature, NPT thread 0=4.6pH, w/o electrode 203108-7 phix Compact ph and temperature, NPT thread 0=7.0pH, w/o electrode phix Compact ph Transmitter, with electrode 203110 phix Compact ph transmitter complete w/electrode 160310 203111 phix Compact ph transmitter, NPT thread, w/electrode 160310 203112 phix Compact ph and temperature transmitter complete w/electrode no. 160310 203113 phix Compact ph and temperature transmitter, NPT thread, complete w/electrode no. 160310 phix Compact Redox/ORP Transmitter, w/o electrode 203105-ORP 203106-ORP phix Compact Redox/ORP transmitter, ISO thread, w/o electrode phix Compact Redox/ORP transmitter, NPT thread, w/o electrode phix Compact Redox/ORP Transmitter and temperature, w/o electrode 203107-ORP 203108-ORP phix Compact Redox/temperatur w/ ISO thread, w/o electrode phix Compact ORP/Temp. transmitter, NPT thread, w/o electrode phix Compact Redox/ORP Transmitter and temperature, with electrode 203120 phix Compact Redox/ORP transmitter ISO thread, w/electrode 160312 203121 phix Compact ORP/Temp transmitter, NPT thread, w/electrode 160312 203122 phix Compact Redox/ORP/temperature transmitter ISO,w/electrode 160312 203123 phix Compact Redox/ORP/temperatur transmitter NPT,w/electrode 160312 Electrodes 160310 ph electrode 0=4,6pH 0-14 ph, 0-80 deg.c 160311 ph electrode 0=7,0pH 0-14 ph, 0-80 deg.c 160312 Redox / ORP electrode Pt/KCL -1000mV +1000mV -20 +80 deg.c

Order Numbers Electrolyte Cleaning and Buffer Solution 163010 KCl solution 0.5l, 3.0 mol 163032 ph buffer, ph 4,00-0,25 l 163034 ph buffer, ph 7,00-0,25 l 163036 ph buffer, ph 10,00-0,25 l 163040 Redox Buffer 6x20ml +180mV Pt/Kalomel/+220mV PT-Ag/AgCL Fittings and 155200 Immersion fitting for phix Compact electrode 155246 phix sensor adaptor for immersion ISO 155247 phix sensor adaptor for immersion NPT 155254 phix adaptor for Ball float, ISO 155260 PVC pipe 50mm - PN10 (ø50 x 2,4mm) per meter 155268 PVC CAP ISO 50mm w. PG9 Cable Glans 155269 PVC CAP US w. PG9 Cable Glans 155272 Sensor immersion bundle kit for phix compact w/iso thread 155273 Sensor immersion bundle kit for phix compact w/npt thread 200125 Field indicator 531, complete, 4-20mA loop powered 200205 Universal bracket 200210 Wall support for universal bracket 200215 Extension for universal bracketz 205205 Power supply DIN rail 100-240V AC 24V DC 1,75AMP 521409 phix 2 Union nut, ISO 579055 PVC glue bottle with 120 gram MJK Blokken 9 DK-3460 Birkerød Denmark Tel +45 45 56 06 56 Fax +45 45 56 06 46 www.mjk.com ISO 9001:2015 CERTIFICATION TM Connect, MµConnect, Chatter, MagFlux, Oxix, phix compact, Shuttle and SuSix are registrered trademarks of MJK Automation. 2018 Xylem, Inc.