UltraTEV Locator Portable Partial Discharge (PD) investigation system.

Similar documents
UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

UltraTEV Plus+ Operating Manual

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

Partial Discharge, Survey or Monitor?

4830B accelerometer simulator Product overview

PD Solutions. On-Line PD Measurement Devices

THE EVOLUTION OF NON-INTRUSIVE PARTIAL DISCHARGE TESTING OF MV SWITCHGEAR

vscan Data Sheet V1.0

Partial Discharge (PD) techniques for measuring the condition of ageing HV/MV switchgear

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

N. TEST TEST DESCRIPTION

evolution wireless G4 ew 300 G4-HEADMIC1-RC Bodypack Headmic Set

GFL-1000 User Manual Ground Fault Locator

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

N. TEST TEST DESCRIPTION

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

USi Product Presentation. Mayser Ultrasonic Industrial Sensor USi

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

Making Your Tour. State of the Art. TourGuide 2020-D

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

MAGNETIC FIELD METER Operator s Manual

Advanced Test Equipment Rentals ATEC (2832)

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

Portable Multi-Channel Recorder Model DAS240-BAT

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

MAGNETIC FIELD METER Operator s Manual

Applications: FM wireless audio, USB PC audio broadcasting, wireless microphones, maternal and child care.

INSTRUCTION MANUAL PCE-222

MPD 500. Partial Discharge Measuring System for Routine Test Applications

DMS 700 Digital Microphone System

Fluke 3540 FC Three-Phase Power Monitor

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula

GFT Channel Digital Delay Generator

evolution wireless G4 ew 300 G4-865-S Handheld Set

Selective and broadband low frequency field analysis

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

GV-700 VIBE PORT. Installation and. Operating Manual

WMS 450 Wireless Microphone System

Operators Manual For Spectrum Analyser SA97

HIGH-POWER, REPORTAGE WIRELESS-MICROPHONE SYSTEM RPU300 - FULL-DUPLEX PORTABLE TRANSCEIVER VHF Main-transmitter - UHF Communications-receiver

ULTRASOUND DETECTOR D240x OPERATING INSTRUCTIONS. Pettersson. Phone: Fax:

lks1000-v3 IDEAL FOR ISO ENERGY MANAGEMENT

APPA 300 Series. The Most User-Friendly High Performance Multimeter

evolution wireless G4 ew 500-G4-935 ew 500-G4-945 ew 500-G4-965 Vocal Set

Ultrasound Condition Monitoring

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

leica-geosystems.com Leica DD SMART utility locator solution Work safer, work smarter, work simpler

"L" Series. Open Face Piezo Transducers. Dimensions: Dimensions are in mm

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

INFOCAL 8 Energy calculator

HSA-Q1. Handheld RF Spectrum Analyser. Frequency Range: 1MHz GHz. Sweep time: 27 GHz / sec

GFT1504 4/8/10 channel Delay Generator

BM25 Automated 5-kV Insulation Tester

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss.

User Friendly Interface means: Power through Simplicity

evolution wireless G4 ew 100 G4-835-S ew 100 G4-845-S ew 100 G4-865-S Vocal Set

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

Ultrasonic level transmitter, non-contact

evolution wireless G4 ew 500-G4-MKE 2 Lavalier Set

HIGH-POWER, REPORTAGE WIRELESS-MICROPHONE SYSTEM RPU300-UU - FULL-DUPLEX PORTABLE TRANSCEIVER UHF Main-transmitter - UHF Communications-receiver

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

M5090. Extended Specifications EXTEND YOUR REACH TM

SONOMETER TM 1100 Ultrasonic compact energy meter

ELITE PRO. Automation Components, Inc.

Handheld Spectrum Analyzer R&S FSH3

Handheld Spectrum Analyzer R&S FSH3

Instruction Manual. TT1000 Tower Earth Tester. Rev 01

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

The new generation More comfortable even faster more precise SmartBalancer2 Perfect field balancing made easy

AC3000 INTELLIGENT BROADBAND AMPLIFIER

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

SL7000 Series. Universal Input Data Loggers

Fluke 3540 FC Three-Phase Power Monitor

User Manual. ilive 2 Wireless microphone system

SONOMETER TM 1100 Ultrasonic compact energy meter

OXFORD MODEL: OXFORD OXFORD DAB+ FM RADIO USER MANUAL

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

The Standard for over 40 Years

FRAX Series Sweep Frequency Response Analyzers

OPCOM RESEARCH LIMITED

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

ALAN 777 PMR 446 Radio Set User manual

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider

MPD 600. High-end measurement and analysis system for partial discharges

RD1000 Ground Probing Radar

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

Applications Features

PIPELINE DEFECT MAPPER

VMS-4000 Digital Seismograph System - Reference Manual

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

User Guide (Clarett USB Edition)

Transcription:

UltraTEV Locator Portable Partial Discharge (PD) investigation system Locates, measures and records PD activity in all substation assets including cables www.eatechnologyusa.com

Benefits Locating and measuring PD activity to identify faults BEFORE they lead to failures Recording and analysing PD activity to provide valuable information on the actual condition of assets More effective asset management, reliability, efficiency and safety, at lower cost Features Ability to pinpoint PD activity to within 10cm Ultrasonic and TEV sensors for surface and internal PD Measures environmental conditions: temperature, pressure and humidity Records the severity of PD for diagnostic analysis Works with cables and overhead assets Tough, weatherproof case with built-in 13 hour battery life FACT 85% of disruptive substation failures are PD related FACT The UltraTEV Locator is the most powerful multi-sensor PD investigation system on the market FACT The TEV technique for detecting internal PD was developed by EA Technology in the late 1970 s for on-line detection

Multiple Functions 1. PD Location Both TEV Probes are used to locate the source of the PD activity, using time-of-flight measurements between the two probes. The latest electronics enable the system to calculate the site of the discharge to an accuracy of 0.3ns (nanoseconds), equivalent to 10cm. 4. Cable PD Activity PD activity in cables is measured using a plug-in Radio Frequency Current Transformer (RFCT) Results are displayed in pico Coulombs (pc) as numerical values. 2. PD Survey In survey mode, a single probe is used in the same ways as our UltraTEV Detector and UltraTEV Plus+ handheld instruments, to detect PD activity. Both ultrasonic and TEV sensors are used. The magnitude of the PD is displayed along with a simple traffic light indicating the level of PD activity detected. Green indicates no significant discharge, amber indicates some activity, and red warns the activity is at a level that warrants further investigation. Operators can use the default factory set threshold levels, or set their own. 3. PD Comparative Measurement Operators have a range of options: Measure the surface PD activity using the ultrasonic mode, and compare the result with those taken from other similar assets. 5. PD Activity Recording All of the measurements taken by the UltraTEV Locator, including the audio output, can be saved to the system s internal memory. The saved data can be downloaded via the USB port to a memory device. The files can then be read directly into a spreadsheet for inclusion in reports, etc. Listen to the surface PD activity from the audio output (the system heterodynes the ultrasonic signal for this purpose). Take TEV readings of internal PD activity at various points on the asset. Factor in readings of localised temperatures indicating hot spots. Factor in environmental conditions: ambient temperature, relative humidity and atmospheric pressure all of which can influence PD activity. Compare results with those taken from other similar assets and historical records.

Valuable condition data The UltraTEV Locator when used in conjunction with the UltraTEV Monitor provides operators with all the information they need to move towards full condition based asset management techniques. The ability to gather data on the condition of assets is a key part of the process of upgrading to Condition Based Risk Management (CBRM). This is EA Technology s market-leading methodology, based on applying a Health Index to each asset and factoring in both the probability and consequences of their failure: an approach which is proven to improve asset reliability, availability and safety, while reducing the overall costs of asset maintenance and replacement. Driven by customer need The addition of the UltraTEV Locator and UltraTEV Monitor to our portfolio is the direct result of listening carefully to what customers require from their new asset management systems.

Operator friendly Intuitive software accessed through easy-to-use touch screen menus. 1 2 3 Weatherproof carry case Can be carried halter-style or over-the shoulder High resolution touch-screen - can be operated through the carry case cover 4 5 6 Simple touch-screen navigation between functions, including browser for stored data files A phase reference is used to synchronise PD with the local power frequency, this is provided by either a plug in phase reference supplied with the instrument or optically from any nearby mains powered lighting source The discharge pattern screen displays where the PD is occurring on a mains cycle time base. Patterns can be compared to distinguish between PD and electrical noise as PD is synchronised to the mains cycle. 7 8 USB port for easy transfer of stored PD activity data to PCs. Also makes it simple to download and install the latest software updates Integral Function Checker confirms the instrument is operating correctly

Specification: UltraTEV Locator TM TEV Sensor Measurement Range Resolution Capacitive 0 60dBmV 1dB Max Pulses/Cycle 2216 Min Pulse Rate Precedence Discharge Pattern Phase Reference ULTRASONIC Measurement Range Resolution Accuracy Transducer Sensitivity 10Hz (rolling displays only) 0.3ns equivalent to 10cm Optical or plug-in -7dBµV to 68dBµV 1dB ±1dB -65dB (0dB = 1volt/µbar RMS SPL) HARDWARE Enclosure Indicators Controls Connectors Headphones Self-colour injection moulded plastic case Colour back-lit LCD Charging indicator LED Touch screen TEV/Ultrasonic Lemo mixed socket TEV Lemo mixed socket Cable PD BNC External Ultrasonic sensor Lemo multipole socket Non-contact temperature sensor Lemo multipole socket 3.5mm stereo headphone socket USB 1.1 port type-a receptacle 2.1mm 18V DC charger input Min. 8 ohms Transducer Center Frequency 40 khz Transducer Diameter 16mm ENVIRONMENTAL Heterodyning Frequency 38.4 khz Operating Temperature Humidity 0 55 degrees C 0 90% non-condensing IP Rating 42 CABLE PD Sensor Measurement Range Resolution Accuracy Min Pulse Rate RFCT 0 25,000pC 98pC ±98pC 10Hz POWER SUPPLIES Internal Batteries Typical Operating Time Battery Conservation 3.7V 27.2Ah Lithium-Ion approx. 13 hours Automatic low battery voltage switch off

The UltraTEV Locator TM kit consists of... UltraTEV Locator Main instrument TEV/Ultrasonic Probe TEV/Magnetic Probe Ultrasonic Contact Probe Flexible Sensor Non-Contact Temperature Probe RFCT Peltor Neckband Headphones AC Reference Source Battery Charger Carry Case Operating Manual Plug-in accessory The range of UltraTEV Locator functions can be greatly extended with this fully compatible accessory: UltraDish Ultrasonic directional microphone which enables operators to listen to PD activity on overhead assets.

Global support The UltraTEV Locator can be supplied and supported anywhere in the world, through our network of international sales offices and distribution partners. We provide excellent lifetime support for this system, including: Installation and commissioning Training Lifetime technical support Online data analysis and reports Distributors Global Offices Our expertise We provide world-leading asset management solutions for power plant and networks. Our customers include electricity generation, transmission and distribution companies, together with major power plant operators in the private and public sectors. Our products, services, management systems and knowledge enable customers to: Prevent outages Assess the condition of assets Understand why assets fail Optimise network operations Make smarter investment decisions Build smarter grids Achieve the latest standards Develop their power skills