APPA 300 Series. The Most User-Friendly High Performance Multimeter

Similar documents
Data sheet IDM 99III Digital Multimeter

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Data sheet IDM 98III Digital Multimeter

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Agilent 970-Series Handheld Multimeters Data Sheet

OPERATOR S INSTRUCTION MANUAL

400Amp True RMS AC/DC Clamp Meter Model EX613

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDM 503 & 505 Digital Multimeters

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

HP 34401A Specifications 8

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

IDM 98-III & IDM 99-III Digital Multimeters

Instruction Manual IDM207 Digital Multimeter

SDM3045X Digital Multimeter. DataSheet

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

2000 A DCA/ACA CLAMP + DMM,

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

79/26 Series III Multimeter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

1.General instructions Specifications Description...7

Instruction Manual IDM 503 & IDM 505 Digital Multimeters IDM 505

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Fluke 83V and 87V Digital Multimeters

Digital MultiMeter - Make your job efficiency User Instruction Manual

SUBJECT TO CHANGE WITHOUT NOTICE

GAMMA 12 DIGITAL MULTIMETER

600A Clamp Meters w/tightsight Display

Current Clamp. 210

GAMMA 10 DIGITAL MULTIMETER

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

DVM1190 DIGITAL MULTIMETER

# Digital Multimeter

The Meter Structure The Figure 2-1 shows the Meter structure.

Pocket Size Digital Multimeter with USB Model: A & A

BENCH METER Model>9803. Wavecom Instruments

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Caution Symbol. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap.

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Analog Technologies VC99. Multimeter FEATURES

USER'S MANUAL DMR-6700

Insulation Testers and Earth Ground Testers

User Manual. All rights reserved. Specifications are subject to change without notice.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Analog Digital Multimeter with Insulation Resistance Measurement

AM

Testing & Measurement

DL-91 DL-92 DL-94 DL-97

ATK Clamp Meter

Sales: Technical: Fax:

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

TESTING & MEASUREMENT

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Fluke 170 Series True-rms Digital Multimeter Extended Specifications

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

UT207A/208A/209A Operating Manual. Table of Contents

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

VC835 DIGTAL MULTIMETER Operation Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

R/C SMD Tweezers Multimeter Model RC200

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MW3105 DIGITAL CLAMP MULTIMETER

Keysight 34401A Multimeter

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Model 77 Series IV. Digital Multimeter. Users Manual

SDM3045X Digital Multimeter. DataSheet

User s Guide. 400A AC/DC Clamp Meter. Model MA220

114, 115, and 117. True-rms Multimeters. Users Manual

1587/1577 Insulation Multimeters

Indeks: WMXXCMM60 Advanced Industrial Multimeter

G R E G E D WA R D S

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

True-rms Multimeter. Users Manual

Model & MultiScope TM

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

Autoranging Multimeter Extech EX503

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Transcription:

APPA 300 Series The Most User-Friendly High Performance Multimeter

Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT" "RANGE" "BLUE Key To turn ON/OFF the backlight (Also can be set at desirable Auto-off minutes). To select regular bargraph, zoom bargraph, center zero, zoom center zero or no bargraph. To choose 40000 count or 4000 count digital display. To manual ranging for fast measurements, To change to ''BLUE'' function on rotary switch. Fully autoranging on 12 functions: DCV, ACV, AC+DC V DCA, ACA, OHM, Low Voltage OHM DIODE Test CONTINUITY Test CAPACITANCE FREQUENCY COUNTER TEMPERATURE (APPA 303, 305) On-Screen-Menu Selection, No Confuse, No mistake... For multifunction application, use the Screen Menu to Select function by matrix operation of F1, F2, F3, F4 and O... "STORE", "RECALL" Store and Recall test data up to 7 memories on the second display. "RESET" Reset meter at any time. "AUTO HOLD" Automatically captures the measurement and updates with each new measurement. "PEAK HOLD" Fast 0.1 millisecond peak hold (APPA 303, 305). "MAX", "MIN", "MAX-MIN" On the second display with time stamp. "HIGH", "LOW" To do as a Comparator with the second display. "", "%" Relative function and Percentage function. "REF" Reference function, useful for offset data. "SETUP" ( Allow you to setup buzzer ON/OFF, Average ON/OFF. Auto Power Off minutes, Back Light minutes, Hertz disp ay ON/OFF, Line frequency, dbm impedance and Reset function. "dbm", "db" Dual display of frequency and dbm or db reference. "SEND" To send measuring data to computer. The unique Screen Menu plus full annunciators will help you concentrate on pick signal and look at the display, there's no need to look at the input connection or switch position.

Engineered to Work Anytime, Anywhere ALL-WEATHER HOUSING Designed for harsh environments with water tight gaskets at the seams, rotary switch, input terminals and battery cover to keep out dust, dirt and splashing. They can also take shocks and drops, work anywhere from indoor to outdoor. DAY & NIGHT Every APPA 300 Series meter has a backlit display that turns ON/OFF at the touch of a button, also automatically goes off at selectable minutes. EXTRA PROTECTION Every APPA 300's meter is supplied with a protective holster that includes a built-in tilt stand, a nail hook, and convenient test lead storage. This holster provides an extra degree of protection and convenience for your meter. SAFETY & DURABILITY High energy fuses, spark gaps, PTCs, and fusible resistors protect APPA 300's meter, and its user, from overloads. The unique rotary switch, constructed with durable engineering plastic, beryllium copper contacts, and goldplated circuit boards, will provide years of use. NO-OPTION FULL ACCESSORIES Ergonomically designed test leads with comfort-grip, safety-shrouded, full-sleeve right-angle plug and hard alloy trips for long life. Slip-on insulated alligator clips are standard. Also supplied with temperature adaptor and bead sensor (Model 303 and 305).

Safe & Easy Connection to PCs The APPA 300 Series built-in RS 232 Interface gives you a safe and easy gateway to your PCs. The optical-electronic RS 232 interface cable/adapter and APPA WinDMM 300 software are included with model 305, or optional purchase with model 301 and 303. Auto Calibration Every APPA 300's meter can be easily Auto-Calibrated through external calibrator and PCs by connecting test leads and RS 232 cable to the meter, no need to open its housing. Virtual Instrumentation... The LabVIEW-based software empowers users to build their own instrumentation systems with standard PCs and APPA 300 Series meter that called Virtual Instrumentation. You can mix and match your choice of data acquisition to create virtual instrumentation systems that exactly meet your needs. Data Acquisition and Analysis Download information from the meter to your PC when you want to document measurements for reports, or to make data analysis through powerful, comprehensive APPA WinDMM 300 software for statistics and evaluations.

The Best Value for Your Money APPA 300 Series Multimeter: Summary Specifications and Feature Sets MEASUREMENT RANGE Vdc 0V ~ 1000V Vac 0V ~ 750V (40Hz ~ 100KHz) Adc 40µA ~ 10A Aac 40µA ~ 10A Ohms 0Ω ~ 40MΩ Capacitance 4nF ~ 10mF Frequency 40Hz ~ 4MHz Temperature (K Type) -200 C ~ 1300 C FEATURE Analog Bargraph Display, 80 Segments Zoom Analog Bargraph Centre Zero Analog Bargraph Auto Calibration Auto HOLD Auto Fuse Detector Beep Guard Continuity Check / Beeper Dbm/db Readings with Selectable Ref. Impedance Delta mode with % Diode test Hazard Warning HI/LO Limits Low Voltage Ohms Memory Store and Recall MAX / MIN / MAX-MIN True RMS (AC, AC + DC) VAC / Hz / Period Triple Display Water / Dust Resistant Zero Reference 600V High Energy Fuse Holster and Stand LCD Backlight Peak and circuit (0.1 millisecond) RS232 Phototronic Serial Port RS232 Cable APPA WinDMM 300 Software Safety APPA 301 0.20% 1.00% 0.50% 1.20% 0.50% 1.90% 0.01% N/A N/A IEC, UL, CSA BASIC ACCURACY APPA 303 0.10% 0.70% 0.30% 1.00% 0.40% 1.40% 0.01% 1 C IEC, UL, CSA APPA 305 0.06% 0.50% 0.20% 0.80% 0.30% 0.90% 0.01% 1 C IEC, UL, CSA

SPECIFICATIONS: (All at 23 C ± 15 C, <80% R.H.) Multiply accuracy digits by 10 in 40000 count mode. VOLTAGE: 40mV DCV 301 303 305 (0.20% + 8d) (0.10% + 8d) (0.06% + 8d) 400mV 4V, 40V, 400V, 1000V (0.20% + 2d) (0.20% + 2d) (0.10% + 2d) (0.10% + 2d) (0.06% + 2d) (0.06% + 2d) ACV 301 303 305 400mV, 4V, 40V, 400V, (1.00% + 5d) (0.70% + 5d) (0.50% + 5d) 750V Bandwidth 40Hz ~ 10KHz 40Hz ~ 50KHz 40Hz ~ 100KHz AC + DC V 301 303 305 400mV, 4V, 40V, 400V, (1.00% + 5d) (0.70% + 5d) (0.50% + 5d) 750V Bandwidth 40Hz ~ 10KHz 40Hz ~ 50KHz 40Hz ~ 100KHz Resolution: 1µV in the 40mV range. Input Impedance: 10MΩ, <100pF. Overload Protection: 1000V dc, 750V rms. AC Conversion Type: AC Coupled True RMS responding. CURRENT: DCA 301 303 305 40mA, 400mA (0.50% + 4d) (0.30% + 4d) (0.20% + 4d) 4A, 10A (0.50% + 4d) (0.30% + 4d) (0.20% + 4d) ACA 301 303 305 40mA, 400mA, 4A, 10A (1.20% + 8d) (1.00% + 8d) (0.80% + 8d) Bandwidth 40Hz ~ 400Hz 40Hz ~ 400Hz 40Hz ~ 400Hz Range: 40mA, 400mA, 4A, 10A. Resolution: 1µA in the 40mA range. Burden Voltage: 800mV max. for ma input, 1V max. for A input. AC Conversion Type: AC Coupled True RMS responding. Input Protection: Equipped with High Energy Fuse. 1A, 600V, IR 10KV fuse (Bussmann BBS-1 or equivalent) for ma input. 15A, 600V, IR 100KV fuse (Bussmann KTK 15 or equivalent) for A input. RESISTANCE: OHM 301 303 305 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (0.50% + 2d) (0.40% + 2d) (0.30% + 2d) LV OHM 301 303 305 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (1.00% + 2d) (0.80% + 2d) (0.60% + 2d) Resolution: 0.01Ω in the 400Ω range. Open Circuit Voltage: 3V. Open Circuit Low Voltage: 0.6V. CONTINUITY TEST: Continuity Threshold: Approx. 50Ω Continuity Indicator: 2KHz Tone Buzzer. DIODE TEST: Test Current: 1.1mA (Typical). Open Circuit Voltage: 3V DC (max.) CAPACITANCE: DCV 301 303 305 4nF, 40nF, 400nF, 4µF, 40µF, 400µF, 4mF, 10mF (1.90% + 2d) (1.40% + 2d) (0.09% + 2d) Range: 4nF, 40nF, 400nF, 4µF, 40µF, 400µF, 10mF Resolution: 1pF in the 4nF range. FREQUENCY COUNTER: Range: 400Hz, 4KHz, 40KHz, 400KHz, 4MHz Resolution: 0.01Hz in the 400Hz range. Accuracy: (0.01% + 1d) Sensitivity: 0.5V p-p, for 40Hz ~ 1MHz, 1V p-p, for 1MHz ~ 4MHz TEMPERATURE: Range: -200 C ~ 1300 C Resolution: 0.1 C Accuracy: 1 C + 1d GENERAL: Display: 4¾ digit (4000 cunt) and 3¾ digit (4000 count), 80 segment analog bar graph and full annunciators, automatic polarity indication. Measuring Rate: Digit 2 times per second for 4¾ digit, Digit 4 times per second for 3¾ digit, Analog bargraph 20 times per second. Overrange Indication: OL is displayed. Auto Power Off: User selectable (default: 30 minutes). Operating Temperature: 0 C ~ 50 C Storage Temperature: -20 C ~ 60 C Temperature Coefficient: 0.1 x (Spec. Accuracy) per C, <18 C or >28 C Relative Humidity: 0% to 80% Shock & Vibration: per MIL-T-28800E TYPE II Class 5. Dust/Water Protection IP Rating: IP 64. Safety: Designed to IEC 1010-1, UL 3111 and CSA specifications. Maximum Voltage to Earth: 1000V DC or AC peak from any terminal. Power Requirement: IEC 6LF22, 6AM6 or NEDA 1604A 9V x 1. Battery Lift: 100 hours typical (alkaline). Size: 90mm (W) x 200mm (L) x 42mm (D) (3.54in x 7.87in x 1.65in). With holster 100mm x 212mm x 55mm (3.94in x 8.35in x 2.17in). Weight: Approx. 14.8oz (420g). With holster 22.9oz (650g). Included with Instrument: Safety-designed test leads, test clips, a 9V alkaline battery (installed), instruction manual, a protective holster with stand, a temperature adaptor (for APPA 303, 305), a K type bead sensor (for APPA 303, 305), a RS232 cable and APPA WinDMM 300 software (for APPA 305). al Accessories: APPA 32 AC/DC Current Probe Non-instrusive transducing from 0.1A to 600A with 2% basic accuracy. Wide jaw fits over almost any size conductor. Coiled cable with safety banana plug extend up to 1.5 meters, 50 hours typical battery life, 9V battery installed. AC-300 Carrying Case Tough, double wall woven fabric, two way zipper carrying case for APPA 300 series multimeter. Inside pockets are designed to carry test lead, temp. adaptor, bead probe, RS232 cable and manual. LabVIEW is a trademark of National Instruments Specifications subject to change without notice