Line Lite International BV 150 watt Cree PowerLED Streetlight 50 x 3 watt IP65 60 degr

Similar documents
Line Lite International BV Petrol Gas Station Light 50 watt IP65

Lamp measurement report 1 Feb 09 for Line Lite International BV Line Lite International BV Sharp 4W GU10 WW

Line Lite International BV 7W Dimmable Downlight Sharp

Lamp measurement report 25 March 09 for LedNed LedNed spotlight MR16GU5.3 WW

Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV

Led Spot MR16 10W Cold White by CDE Technology BV

20W TL 324 smd LED Warm White by Simplify-It

Led 12V 3W Spot Light GU5.3 by Tuono Lighting

LED T5 30cm Warm White by BS Ledlight

High Bay Led Lamp by Glo

Led Tube Light KLV-T8-121-WA by KLV Ledverlichting

Flood Light LVS-70 Warm White by Ledverlichting Soest

LVS C42 GU10 4W WW by Ledverlichting Soest

LVS D01 GU10 3W WW dim by Ledverlichting Soest

LVS C76 GU10 9W Nichia by Ledverlichting Soest

1200 x 300 mm led panel by ElektoLED

Negative ion Lamp GTFL-13 by GreenTubes

LVS A16 MR16 3x3W Cree by Ledverlichting Soest

Lamp measurement report - 13 May 2012 Led TL 120 cm 18W 6500K by Prolumia

Pharox MR16 by Lemnis

Lamp measurement report - 13 Nov 2012 LED light bulb E14 dimmable by Oxxy Light

Lamp measurement report - 11 Feb 2013 E27 led light bulb XP-e Cree 8x1W by TOP.LED.SHOP

Lamp measurement report - 13 April 2016 ONT x18 by Triolight B.V.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

PAR30S GU W OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Report No.: EASZE Page 2 of 14

Basic lighting quantities

Eternal Shine Technology Co.,Ltd. EST

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Ledison LED Troffer Light Back Lit Structure

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Photometric Test Report

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Photometric Test Report

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Photometric Indoor Test Report

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Cat# LED High Bay

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.


NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

RoHS QPL ID # PLC6V1PABNUJS

Cat# 71146A 150W Trunion Mount

Properties of LED considering museum lighting

SpecSheet_AR111_18.5W_VIVID UND BRILLIANT 2 SpecSheet_AR111_12.5W_VIVID UND BRILLIANT 7 SpecSheet_AR111_6W_VIVID UND BRILLIANT 12

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

IESNA LM79: 2008 Photometric Test Report

Cat# LED Classic Large Wall-Pack

Photometric Test Report

Photometric Test Report

LM Test Report

LM Test Report

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

daylight Spring 2014 College of Architecture, Texas Tech University 1

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Transcription:

Line Lite 150 watt Cree PowerLED Streetlight 50 x 3 watt IP65 60 degr Page 1 of 16

parameter meas. result remark Color temperature Luminous intensity I v Beam angle Power P Summary measurement data 8446 K Cold white 3063 Cd 87 deg 135 W Power Factor 0.73 For every 1 kwh net power consumed, there has been 0.9 kvahr Luminous flux Luminous efficacy 5372 lm 40 lm/w for reactive power.. CRI_Ra 79 Color Rendering Index. Coordinates chromaticity diagram x=0.2930 and y=0.2957 Fitting 230V Direct connection to the mains voltage. L x W x H ext. dimensions L x W luminous area General remarks 695 x 315 x 130 mm 352 x 215 mm External dimensions of the street light. Dimensions of the luminous area (used in Eulumdat file). This is equal to the surface of the transparent part of the glass plate in front of the leds. The ambient temperature during the whole set of measurements was 28-28.5 deg C. Warm up effect: during the warm up time the illuminance will decrease about 10 %. Voltage dependency: the power consumption is a little dependent on the input voltage (in a linear way), the illuminance not at all. This article contains an additional photo of the streetlight. Page 2 of 16

Eulumdat light diagram An interesting graph is the light diagram, indicating the intensity in the C0-C180 and the C90-C270 plane. This light diagram below comes from the program Qlumedit, that extracts these diagrams from an Eulumdat file. The light diagram giving the radiation pattern. It indicates the luminous intensity around the light bulb. The C0-C180 plane has the same direction as the street over which this light bulb will be placed. The C90-C270 direction is along the length of the light bulb. The C90 plane is situation at the front side of the light bulb (this is where the transparent glass plate hits the side of the housing). Page 3 of 16

The convention used for C-planes for street lights There is little difference between the diagrams for the given planes. The unit is Cd/1000lm, meaning the intensity in Cd assuming there would be 1000 lumen in the measured light bulb. This enables comparing different types of light bulbs. Illuminance Ev at 1 m distance, or luminous intensity Iv Herewith the plot of the averaged luminous intensity Iv as a function of the inclination angle with the light bulb. Page 4 of 16

The radiation pattern of the light bulb. This radiation pattern is the average of the light output of the light diagram given earlier. Also, in this graph the luminous intensity is given in Cd. These averaged values are used (later) to compute the lumen output. Page 5 of 16

Intensity data of every measured turn angle at each inclination angle. This plot shows per inclination angle the intensity measurement results for each turn angle at that inclination angle. There are differences in illuminance values for different turn angles. However for further calculations the averaged values will be used. When using the average values per inclination angle, the beam angle can be computed, being 87 degrees. This is the average value for all C-planes on average. There is little difference between the C-planes so this beam angle is accurate for most C-planes. Luminous flux With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible to compute the luminous flux. The result of this computation for this light spot is a luminous flux of 5372 lm. Luminous efficacy The luminous flux being 5372, and the power of the lightbulb being 135 W, yields a luminous efficacy of 40 lm/w. Page 6 of 16

A power factor of 0.73 means that for every 1 kwh net power consumed, a reactive component of 0.9 kvar was needed. Light bulb voltage (used on power supply!) 230 VAC Light bulb current 805 ma Power P 135 W Apparent power S 185 VA Power factor 0.73 Of this light bulb the voltage across ad the resulting current through it+its power supply are measured and graphed. Voltage across and current through the lightbulb There are peaks in current near the tops of the voltage. This results in a waveform for the current that is different from the sineform of the voltage, resulting an a power factor less than 1. The current drawn in high peaks has as a consequence that the mains voltage tops are capped. Also the power spectrum of the current is determined. Page 7 of 16

Current power spectrum in % of the first harmonic (50 Hz). The current peaks result in a current power spectrum with a considerable amount of higher harmonics. Page 8 of 16

Color temperature and Spectral power distribution The spectral power distribution of this light bulb. The measured color temperature is about 8500 K which is cold white. This color temperature is measured straight underneath the light bulb. Below a graph showing the color temperature for different inclination angles. Page 9 of 16

Color temperature as a function of inclination angle. The color temperature is given for inclination angles up to 70 degrees, since at higher angles there is almost no light output anymore. The value remains constant within 25 %. Page 10 of 16

Chromaticity diagram The chromaticity space and the position of the lamp s color coordinates in it. The light coming from this lamp is at some distance from the Planckian Locus (the black path in the graph). Its coordinates are x=0.2930 and y=0.2957. Page 11 of 16

Color Rendering Index (CRI) or also Ra Herewith the image showing the CRI as well as how well different colors are represented (rendered). The higher the number, the better the resemblance with the color when a black body radiator would have been used (the sun, or an incandescent lamp). Each color has an index Rx, and the first 8 indexes (R1.. R8) are averaged to compute the Ra which is equivalent to the CRI. CRI of the light of this lightbulb. The value of 79 is lower than 80 which is considered a minimum value for indoor usage. Note: the chromaticity difference is 0.0068 indicates the distance to the Planckian Locus. Its value is higher than 0.0054, which means that the calculated CRI result is meaningful. As this led light is not used for indoor usage, it is not of a problem. Voltage dependency The dependency of a number of lamp parameters on the lamp voltage is determined. For this, the lamp voltage has been varied and its effect on the following light bulb parameters measured: illuminance E_v [lx], the lamppower P [W], the (Correlated) Color Page 12 of 16

Temperature [K] and the luminous efficacy [lm/w]. Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %. The consumed power is the only parameter that varies (and the luminous efficacy as a consequence), in a linear way, when the voltage varies between 200-250 V. The variation is small. When the voltage at 230 V varies with + and - 5 V, then the illuminance varies within 0.1 %, so when abrupt voltage changes occur this effect is not visible in the illuminance output. Warm up effects After switch on of a cold lamp, the effect of heating up of the lamp is measured on illuminance E_v [lx], color temperature CT or correlated color temperature CCT [K], the lamppower P [W] and the luminous efficacy [lm/w]. Page 13 of 16

Page 14 of 16

Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end. The warm-up time is a bit more than one hour, and expected illumination drop is about 10 %. Additional photo Close up of the leds. Page 15 of 16

Disclaimer The information in this OliNo report is created with the utmost care. Despite of this the information can have inaccuracies. OliNo cannot be held liable for the content of the information in this report nor for the consequences of its use. The data in this report is not legally binding. Page 16 of 16