T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Similar documents
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

ED701 General Industry Pressure Transmitter

KFS. Flap-type flow meter. Design and range of application

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Mechatronic pressure measurement. Applications. Special features. Description

SATRON VB Pressure Transmitter

Relative and absolute pressure transmitter type 528

Design and applications

SALES SERVICE +358 (0)

Target disk flowmeter for liquids and gases

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

CombiTemp TCR6 Standard RTD temperature sensor

Relative and absolute pressure transmitter type 528

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Resistance Thermometers Model Series TR7X0, Sheathed Design

Standard Bourdon tube pressure gauges EN 837-1

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Positioner with HART Communication Type 3780

Digital flow transmitter for continuous flow measurement

The transducer component converts the measured signal and displays the actual value.

Level and Pressure. Product Information. Vibrating level switches

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

SUNSTAR 传感与控制 TEL: FAX: Relative and absolute pressure transmitter type 528

Incremental Encoder Model: FOI58

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Relative pressure transmitter type 522 for shipbuilding

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Metal tube variable area flowmeters for gases, liquids and steam

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Dialog with the medium.» BEDIA Capacitive Level Sensors for industrial applications

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

IP26 Series Current to Pneumatic Converter

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Resistance thermometer Model TR30, compact design

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Page Type Resolution (mm) min. max. Output

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

ES Series Features Detecting distance twice that of conventional

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Digital inductive conductivity transmitter

Inductive sensor slot-type SI2-K08-AP7

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Positive Displacement Flow sensors

Electrical Alarm Contacts

Coriolis Massflowmeter

OPTIFLUX 5000 Technical Datasheet

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Remote Switching Unit nivotester FTL 320

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Pressure transmitter for general industrial applications Model A-10

LEVEL Switches RFM-500 RAM-403 RRH-300 RLH-300 RNM-401

Level gauges Series LT Level indicator, switch and transmitter for liquids

High Accuracy Positioning Sensors EG Series Features

High-quality pressure transmitter For general industrial applications Model S-10

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Field indicator for current loops with HART communication Models DIH50, DIH52

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Liquid Level Switches

Resistance thermometer Model TR30, compact design

Valve Island with Electronic I/O

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

2/2-Way Solenoid Control Valve

Magnetic Inductive Flow Sensors VMI Series

Submersible pressure sensor For oils and fuels Model LF-1

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Electromagnetic Flow Transmitter

... for hydraulic and general applications in hazardous areas

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

FIELD DEVICES PRESSURE

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

PHÖNiX. Magnetically operated level switches Product group 740. Type - Table Mechanical Data. Table Electrical Data, Ex-Classification.

TMU. Coriolis Mass Flow Meter. for liquids and gas

INSTALLATION AND OPERATION MANUAL

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

Process Protection Acoustic sensors for pump monitoring

Submersible pressure sensor For superior applications Model LF-1

ProcessMaster / HygienicMaster

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Pressure transmitter For general industrial applications Model A-10

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Ultrasonic level transmitter, non-contact

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Transcription:

Electrical contacts stainless steel thermometers T11 - T12 - T13 Ø - Ø 1 - Ø 160 mm Derived from the TX thermometers of nominal diameter, 1 and 160, of which they possess all the characteristics, the T11, T12, T13 are instruments equiped with electrical contact blocks enabling all contact combinations. The contact block is fastened to the dial. reset knob with indicator is provided to set the trip points. Contacts specifications are described on following pages. Explosion-proof case version. For the T13 series and for use in explosive areas,the thermometer, with one or 2 inductive contacts, should be used with the amplifying relay RSI 1 or RSI 2. The complete assembly is intrinsically safe, conforming to standards : NF EN 014 - NF EN 020 Specifications (20 C) Range: from -200 C to +600 C Possible overload of +30%. Mounting : Type 11/01 - N 300103 GB ccuracy: Contact : ± 2% of full scale. Pointer : ± 1.6% of full scale. 1.6 class accuracy according to DIN 16085 Degree of protection: IP65 according to NF EN 60529 Sensing element : Low volume spiral having undergone a heat treatment. mbient temperature of the indicator: -10 C to + C Other ambient temperatures : consult us. Case and bezelring: 304 stainless steel. Bayonet type fastening. Window: Transparent polycarbonate convex cap with sealed index setting button. Window gasket: In PVC nitril elastomer. Ensures tightness between window and case. Movement: Stainless steel. Dial: luminium alloy. Black graduations and figures on white background. Graduation conforms to DIN 16 203 standard. Pointer: luminium alloy, balanced, black painted. Direct D F Surface mounting by means of 3 back lugs fixing E Flush mounting with front flange welded on to case C B Blow out disc: In elastomer. It is positioned at the top of thermometer and vents the inside of the case to the atmosphere. Zero setting: fter removing an elastomer plug, the zero setting screw enables to adjust the instrument. Electrical connection: Terminal block. Cable gland M20x1.5. Cable 7 to 13mm Blocks wiring diagram: MIN MX INTER-INDEX MIN-MX 101-3 10-2 01-2 010-2 MIN-MIN 110-3 101-2 MX-MX 011-3 MX-MIN 111-3 Modifications reserved

Dimensions (mm) Type Type B Type C Type or E Type B or C Type D Type E Type F panel cut on Type B or C Cable gland M20x1,5 Weight in kg type D Dimensions mm B C D E F H J K L N P R T U V W X Z Dry (BH) Ø mm 106.2 63 130 118 25.5 23 19 5.5 89 39.3 17 98 54.5 57 105 110 74 107 31.5 0.605 kg 1 1.2 85 180 168 25.5 23 19 5.5 111 39.3 17 142 54.5 57 105 110 96 151 31.5 0.930 kg 160 160.2 99 196 178 23.7 21.7 19.5 5.5 116 38 19 152 55.5 57.5 106 110.5 101 161 54 0.980 kg Options Standard versions of DIRECT THERMOMETERS 3 - Ø 8 mm dia bulb Graduations Coding C Coding F 03-200 + 03-300 + 08-120 + 40 06-200 + 11-70 + 40 10 - + 13-40 + 60 15-40 + 160 22-30 + 32-20 + 25-20 + 40 40 0 + 19-30 + 170 21-30 + 320 16-30 + 270 26-30 + 520 47 0 + 60 49 +20 + 140 51 0 + 52 +20 + 220 53 0 + 120 56 +20 + 270 57 0 + 160 60 +20 + 320 61 0 + 200 65 +20 + 420 66 0 + 2 70 +20 + 520 71 0 + 300 80 +30 + 580 81 0 + 400 90 +30 + 730 99 0 + 600 99 +30 + 1130 ( S Standard Optional bulb S = Not possible For P > 600, consult us T11 - T12 - T13 (Ø - Ø 1 - Ø 160) P 1 2 400 600 ( ( ( ( ( ( ( ( ( ( ( ( Uncoded options (have to be listed after the code number) 316 L stainless steel case and bezel ring Special scales Index setting by inviolable system Coded options BH version (BH3 filling) for T12 and T13 Explosion-proof housing version EEx d II C T6 (1 dia. only) conforming to standards : NF EN 014 - NF EN 018

Electrical contacts CES - CES - CEI - CEI+RSI GENERL Electrical contacts can be fitted to our instruments with nominal diameters, 1, 160 mm. They are adjustable over the whole scale (270 arc maximum). The overall dimensions, mounting and switching arrangements, operating limits (pressure and temperature) are all given in the corresponding documentation for each series of equipment. Various contact models : - dry contact : CES - dry contact with magnet : CES - inductive contact : CEI - inductive contact + amplifier relay : CEI+RSI Specifications Contact material : During their use, electrical contacts are subjected to a varying degree of wear, depending on their operating conditions, under the effect of mechanical stresses, the effect of electrical arc and heating. The choice of material for contacts must allow for the specific operating conditions. Standard material is a g 80-Ni 20 alloy. It has a high resistance to the electric arc effect (sparking). Oil filled version : When a gauge is to be oil filled, CES contacts must be used. The gauge must be filled with silicon oil (BH3). The power breaking capacity is significantly reduced (< 1 m). It is then necessary to use a relay : YR (RSI) or REB (MSR). CUTION : For use with OXYGEN, use filling fluid BH5. Two wire supply NF standard coding Standard nomenclature NF E 15-2 contacts 1 contact 10.2 01.2 Inter Index Closed 010.2 Inter Index Opened 101.2 Contact block control function CES-CES Contact open above the set point Contact closed above the set point Contact closed inside area determined by the 2 set points open outside Contact open inside area determined by the 2 set points closed outside The last figure correspond to the number of terminal output Example : 10-2 (2 terminal outputs) Three wire supply NF standard coding Standard nomenclature NF E 15-2 contacts 101.3 110.3 011.3 111.3 very thick black sector : closed contact very fine sector : open contact Contact block control function CES-CES First contact open second contact closed above the set point First and second contacts open above the set point First and second contacts closed above the set point First contact closed second contact open above the set point

Dry electrical contacts CES PPLICTIONS : These contacts are used when normal service conditions require a low switching power. This type of contacts requires vibration-free installation and cannot be used with liquid filled gauges. In aggressive environments and in areas where there is a risk of explosion, use CEI inductive contacts + RSI amplifier relay or explosion-proof enclosure versions. Technical characteristics Contacts can switch continuous or alterning voltages of up to 2 volts with a maximum rating of 10 W or 18 V. Table of maximal for standard electrical contacts : V Resistive load Inductive load DC C Cosϕ > 0,8 220 40 m 45 m 25 m 110 80 m 90 m 45 m 48 120 m 170 m 70 m 24 200 m 3 m m NOT : with 24 Vcc, minimum current 10 m. Dry electrical contacts with magnets CES PPLICTIONS : These contacts are used in practically all service conditions. They are, to a very great extent, insensitive to vibrations. They can be used with liquid filled instruments. In area s where there is a risk of explosion, use CEI inductive contacts + RSI amplifier relay or explosion-proof enclosure versions. Technical characteristics Contacts can switch continuous or alterning current voltages of up to 2 volts with a maximum rating of 30W or V Table of nominal values : V Resistive load Inductive load DC C Cosϕ > 0,8 220 m 120 m 65 m 110 200 m 240 m 130 m 48 300 m 4 m 200 m 24 400 m 600 m 2 m NOT : values for non-liquid filled instruments. Inductive electrical contacts CEI PPLICTIONS : CEI contacts are used in a highly vibrating environment. They are spark, overheating or wear proof. They must be used with an amplifier relay.

Inductive electrical contacts CEI+RSI amplifier relay Officially approved, intrinsic safety : CEI sensor, EEX ia IIc T6 RSI amplifier, EEX ia IIc PPLICTIONS : CEI contacts are used in explosive atmosphere and hazardous area. They are spark, overheating or wear proof. They must be used with a RSI amplifier relay as follows : Hazardous area Non-hazardous area Power supply Output Specifications Case : SE Noryl. Overall dimensions - mounting : see below. Weight : RSI 1-0.220 kg : RSI 2-0.420 kg Power supply : Standard : Options : 220 Vac ± 15%, 45-60 Hz 110 Vac ± 15%, 40-60 Hz 24 Vcc Consumption : 1.5 V. Output : Reversing contact relay; rupturing capacity 4-2 V - 0 V Operating temperature : - 20 C to + 60 C (-4 F to + 140 F) Protection : IP 30.. RSI pressure gauge distance : 3000 m. (. R in line Ω). Relay dimensions RSI (220 Vac-110 Vac) 1 contact 2 contacts ttachment : on rail DIN 022 or by 2 screws Relay dimensions RSI (24 Vcc) 1 contact 2 contacts DIN-rail mounting DIN-rail mounting ttachment : on rail DIN 022

Codification Thermometer Family : Thermometers T Type : Previous commercial reference TIX/CES 11 TIX/CES 12 TIX/CEI (1) 13 Dial diameter: Ø mm 5 Ø 1 mm 7 Ø 160 mm 8 Ø 1 mm (boîtier DF) E T 1 0 3 5 6 Measurement unit: C F Type of liquid filling: without BH3 filling (- 40 to + C) Code Graduations : see coding columns in table part Dimensions Control function: 1. 2 Inter-index : opened between set points 3 -max 4 -min 5 -max 6 -min 7 Inter-index : closed between set points 8 B C D E F Type of mounting: bottom connection, 3 back lugs fixing back connection, front flange bottom connection, front flange bottom connection back connection, 3 back lugs fixing back connection (1) In an explosive environment, must be used with an intrinsically safe electrical installation. Transmission Type of transmission : 00 TD1 1 01 TD2 2 02 TD3 3 03 TD4 4 04 TRDE 1 05 TRDE 2 C 06 { TRCE 1 E } 07 (2) TRCE 2 F (3) 08 TRCE 3 G 09 TRCE 4 H 10 Capillary length without 1 m 2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m Stem length (mm)*: TD1 standard 00 1 mm 1 2 mm 2 400 mm 400 600 mm 600 00 02 03 05 06 0D 0J 0L 1 XX * Connection : without G 1/4 G 1/2 (2) 1/4 NPT 1/2 NPT G 3/4 G 3/8 G 1/2 female 3/8 NPT out of standard For the choice of the type of transmission and capillary length, please refer to the TX (TIX) separate data sheet. (2) TRCE, only G 1/2 - (3) Indicate value of E and α ( TX (TIX) data sheet). * Bulb with S = or S = mm. Indicate the choice of this option after the code number. * Uncoded options have to be listed after the code number mplifier relay codification Family : ccessories Relay: RSI (intrinsically safe) MSR YR REB Power supply: Standard 220 Vdc Option 110 Vdc D Option 24 Vdc F 0 D D 0 1 2 ttachment on rail DIN Control functions: 1 threshold 2 thresholds Modifications reserved