OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Similar documents
MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

3. COMBINED TRANSFORMERS Oil-paper insulation

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

On-Load Tap Changer Type M

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

No. SSIEC-PRC SHINSUNG. Polymer Recloser SIREC SERIES 15kV, 27kV, 38kV 400A, 630A, 800A

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

Energy Division. Bowthorpe LV/MV Surge Arresters

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

EMI Installation Guidelines

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

K Factor Power Transformers

TECHNICAL SPECIFICATION SHEET

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

INSTRUMENT TRANSFORMERS. Right Choice for Metering and Protection of Power. Electricfield

1 INTRODUCTION ORDER CODE / INFORMATION

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

(

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

3-Phase Transformers. Author: Sergey Dubatov. belfuse.com/signal

Our experience. Our products

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Ritz Instrument Transformers GmbH. Welcome

TMC Transformers TMC

Transformers, Power Supply Units and Socket Outlets

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

NSL-10 STANDARD LIFE MODULAR CAPACITORS

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Isolation Transformer Series

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

700 Series AC Dielectric Test Sets

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Outdoor Instrument Transformers Buyer s Guide

Capacitive voltage transformers

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

POTENTIAL TRANSFORMER

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

50-SDMS-01 SPECIFICATIONS FOR

VI 3 - i TABLE OF CONTENTS

700 Series AC Dielectric Test Sets

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Series P. Applications

Convincing technology creates compact performance

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Description. Features and Benefits

Outdoor Instrument Transformers. Buyer s Guide

ULTRA-K Series 600K - he

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

Section 2 Outdoor Voltage Transformers

Communication by power line carrier technology. For medium voltage networks

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Zelio Control Measurement Relays

Oil insulated Outdoor Instrument Transformers Buyer s Guide

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Arc Suppression Coils

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

siemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution

N. TEST TEST DESCRIPTION

Instrument Transformer Services (ITS) Voltage / Potential Transformer Reclassification

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Capacitive voltage transformers

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

Inductive Voltage Transformers. Types VEOT and VEOS

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Transcription:

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: VTOP 2(1) X Dry Insulated voltage transformer (VT) There are two designs of this voltage transformers: - VTOP 1-X single phase, dry insulated - VTOP 2-X two phase, dry insulated Transformers are monolithically casted within cured epoxy resin and are designed for outdoor installation and for voltage levels between 2.4kV and 27.6 kv. Made to order per specific requests for voltage levels up to 44kV VTOP paired with recloser The magnetic core is classic type and its copper windings are made in layers. This provides convenient distribution of radial and axial stresses as well as good resistance to industrial frequency shocks and transients. The voltage transformer is completely vacuum impregnated and sealed within cured epoxy resin resulting in a one piece compact body with smooth surfaces providing high dielectric strength and mechanical durability. They passed through the most severe climate pollution condition test in South Africa Koeberg Insulator Pollution Test Station (KIPTS). Single phase voltage transformers can also have a residual voltage winding intended for connection in broken delta. Single phase unit can also be with one or two bushings. Single pole transformers have voltage factor of 1,9Un/8h. Double bushing VTOPs are intended for connecting line to line (two phases), line to ground or line to neutral. The transformers are manufactured and certified in Europe in accordance with the following standards and regulations: Fully cured epoxy resin is moisture absorption resistant material and provide VTOP type transformers with body that is non-combustible. All epoxy material used for casting is manufactured in US IEC 60529 / 2013 IEC 60044-2 / 2003 CSA certification completed in Canada 2015. CSA#: 264700: C22.2 No. 47-13.

Features dry insulated transformers type VTOP 2(1) X Advantages: This transformer is fire retardant. 100% copper windings. Built in safety technology to limit overvoltage spikes. Insulation cannot drain out - fully cured in casted resin. Smaller dimensionally since they have special absorbers of Electro Magnetic field. Excellent in ambient temperatures from 50 C to +65 C. Transformer is possible to install in any position and anywhere. Maintenance not required. No enclosure needed for outdoor installation. Environmentally are clean and friendly. They are operating silently and do not produce any noise. Exterior is smooth and round and they are not accumulating dirt. They last three times longer in working conditions than oil based ones. Highly reliable. Single phase or two phase types available. Economical and installation is fast and easy. Customizable for any voltage levels up to 44 kv. Application: Power for: - PLC (Programmable Logic Controllers) mounted on power line poles. - Electrical driving mechanism for disconnectors mounted on power line poles. - Electrical driving mechanism for reclosers mounted on power line poles. - Monitoring cameras, remote wireless and transfer signal equipment. - Control cabinet for high voltage motors. - Remote control units: electrical power networks, water tank, mine, - Telecommunication equipment for cabinets mounted on power line poles etc. Assembly mounted units for: o Controlling quality of electrical power, u[%]. o Metering and relaying circuits - pole mounted.

VTOP 2(1)-X Unit Selection Specification / Type X = 2.4 4.16 4.8 7.2 8.4 12 13.8 14.4 25 27.6 Highest Voltage for equipment Rated Primary voltage (Un) [kv] 7.2 7.2 7.2 15 15 15 15 27.6 27.6 27.6 [kv] 2.4 4.2 4.8 7.2 8.4 12 13.8 14.4 25.2 27.6 Rated Secondary voltage [kv] 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 Winding Ratio ranges: [P:S] 20:1 35:1 40:1 60:1 70:1 100:1 115:1 120:1 210:1 230:1 Power Frequency test voltage Lightning Impulse test voltage (BIL) [kv/1min] 7.2 12 12 22 22 28 38 38 55 55 [kv] 60 60 60 95 95 95 95 150 150 150 Weight [kg] 25 25 25 28 28 28 28 30 32 32 Burden / Accuracy class, 50 /60Hz, (for all types) [VA] / [%] (25 / 0.2), (65 / 0.5), (100 / 1), (200 / 3), (600 to 1000 / 5) Protection 3P or 6P Mechanical Protection IP 54 or NEMA 3R Rated Frequency, (for all types) Rated Voltage Factor/rated duration Mounted / Place [Hz] 50 & 60 1.2Un/ permanent for two phase, 1.9Un/8h - for single phase In any position / Outdoor or Indoor Temperature range: [ 0 C] -50 0 C to +65 0 C Table: 1-1 Additional design, primary and secondary voltages and winding ratios, available on request. 44 kv Units available on request. Accuracy classes in Table 1-1 are indicated per European standards. When ordering specify required Frequency, Rated Primary voltage, Windings Ratio, Accuracy, Burden and Power Factor.

DIMENSIONS [mm] TWO PHASE, VTOP 2 2.4/4.16/4.8/7.2/8.4/12/13.8kV -creepage distance >33kV/mm-for 2.4kV to 13.8kV TWO PHASE, VTOPs 2 14.4/25/27.6kV -creepage distance >33kV/mm-for 14.4kV to 27.6kV

TWO PHASE, VTOP 2 27.6kVfor burdens >600 VA up to 1000 VA SINGLE PHASE VTOP 1 2.4/4.16/4.8/7.2/8.4/12/13.8kV

SINGLE PHASE VTOPs 1 14.4/25/27.6kV -creepage distance >33kV/mm-for 14.4kV to 27.6kV TWO PHASE, VTOPi 2 7.2/12/15/24kV - Indoor installation

METERING UNITS THREE PHASE 3 MTOP 1-2.4kV to 27.6 kv

Comparison between traditional method of connecting reclosers power box and with VTOP: WHAT IS BETTER: Other loads that are connected to low voltage lines in option A) can cause faults and outage so recloser will loose power too. When power is supplied by VTOP as shown in option B there is no need for low voltage line or step down transformers. Reclosers will always have power.