DIVISION Hardware

Similar documents
DIVISION 8 DOORS AND WINDOWS. 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum.

This section describes the design requirements and materials/products for door hardware.

Finish Hardware. Contents. Section 10

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

350/500 Heavy Wall TM IR Entrances

World s Leading Manufacturer Of Traffic Doors. Supplemental Instructions for the Single and Double Door Order Form

Division 08. Openings

SECTION FINISH HARDWARE

Construction Standards PAGE

55 Series. Exit device

55 Series Exit Device

Metal Sound Retardant Door Hardware Information Bulletin

4200 Series. Commercial Exit Device

Your global resource for quality commercial door hardware. Euroline Catalog Euroline Catalog

350/500 IR Entrances. Features

350/500 IR Entrances. Features

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

350/500 HEAVY WALL TM IR ENTRANCES 1

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

Exit Device 5820 SERIES GRADE 1 PUSH BAR SPECIFICATIONS HEAD COVER OPTIONS STRIKES APPLICATION.

APPENDIX 1H: DOOR HARDWARE 1

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

MEDIUM DUTY LOCKS - LEVERS. Distributed By. DH Pace National Key Service Center DHPace.

ARCHITECTURAL DOOR HARDWARE ROLLER LATCHES, PADDLE HANDLES, DOOR HANDLES & BARS CATALOG

M O R T I S E L O C K S

WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

Architectural Solutions

88 Series. Exit device

7.01. Door Hardware & Accessories

Headline Push/Pull Latches

RENOVATION TO STUDENT SERVICES/HOUSING FROM HOSPITAL DAKOTA STATE UNIVERSITY MADISON, SOUTH DAKOTA

88 Series. Exit device

Masonry Frames Interior/Exterior* Drywall Frames Interior**

CONTENTS. Custom Entrances and Hardware

June, 2018 Page 1 of 12

Introduction Exit Hardware Rim device... 4 Surface mounted vertical rod device... 6 Mortise lock device... 5

Bravura. UL Listed Commercial Locksets FORGED. Designs from Great European Homes. Fall 2009

Exit Devices & Door Locks For Severe Windstorm & Hurricane Doors

DOOR SAVERS AVAILABLE IN STEEL, STAINLESS STEEL (32D), BRIGHT BRASS (3), BRONZE (10) AND OIL RUBBED BRONZE (10B)

Full line catalog. Locks, closers, and exits

Headline. Push/Pull Latches

376E Series Exit devices

8000 SERIES SERIES HEAVY-DUTY MODELS

Victory Fire Door Inspections

Ives Pemko Hager 112HD FMSLFHD HD 224HD FMHD HD 210HD FSHD HD 157HD FSCPHD HD

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

INPACT 94 and 95. Exit device

DB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options

INTELLIKEY. Lock Identification GENIUS AT YOUR FINGERTIPS. 1 rev:

Where plans come together.

1800 Series. Flatbar Exit Devices. An ASSA ABLOY Group brand

SLIDING DOOR LOCKS MISCELLANEOUS

MEETS ADA REQUIREMENTS!

INSTALLATION INSTRUCTIONS CRL JACKSON

BOLOTA 316 OTHER PRODUCT RANGES SERVICE

6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview. Non handed design provides greater flexibility

Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Standard Aluminum Swing Entrance Doors

Monarch XX Series. Crossbar Exit Device

MANUFACTURER & WHOLESALER OF WINLY PRODUCTS

PANIC & EXIT HARDWARE

Product Catalog. hardwaresuppliers.com

Stainless Steel and Brass Flush Handles Meets DS/ISO standard 2768m Page 5-1

930 Series Mortice Exit Device

2.01 Standard Entrances Description

2100 series exit devices. rugged reliability

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Installation Instructions

6200 Series. System Components Series Electric Strikes

FINISH HARDWARE. UNIVERSITY CONTACT: Mark Golden, Manager, Structural Services (302)

L-Series Commercial Locks

Affinity Site Survey. Address: City: State: Zip: Distributor: ACP #: Address: City: State: Zip: Date Submitted: Requested Installation Date:

NM SERIES. Extra Heavy Duty Mortise Locks Grade 1

Adams rite. Deadbolts, Deadlocks & Hookbolts Series maximum security laminated deadlocks/hookbolts

City of St. Charles School District New Addition and Renovation at George M. Null Elementary School 435 Yale Boulevard St. Charles, Missouri 63301

Product Catalog. hardwaresuppliers.com

Grade 2 Medium Duty Cylindrical Key-In-Lever Lock Product Catalog. Z Series

Architectural Hardware

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

FLUSHLINE ENTRANCES. Features

Solid Core Wood Door / Steel Frame Packages

BEFORE STARTING INSTALLATION

INSTALLATION INSTRUCTIONS CRL JACKSON

Steel Hawk 4300 Electrified Deadlatch (elatch)

DOOR TECHNOLOGY ORDER CATALOG SECTION SECURY Automatic Door Lock & Gripset Handle

POST BID ADDENDUM TWO

INPACT 94 AND 95 Series Exit Device

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

8900 Mortise Lock Exit Device 80 Series

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5

custom entrances and hardware

* * 22 & 22-F. Please give these instructions to building owner after device is installed BS EN 1125 : 2008

FEATURES. TownSteel Architectural Hardware MFG

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

98/ Customer Service # Dogging Key (use to lock down pushbar)

LT Series. Decorative tubular locks

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Transcription:

FORMAT 1. Technical specifications content and numbering system shall be based on the most current CSI Master Format. BASIS OF DESIGN 1. APSU design standards shall not replace fully developed, project and market specific technical specifications, with 3 manufacturers unless indicated otherwise, e.g., Stanley CorMax. Associate shall utilize the standards as a minimum standard to guide the design. 2. Design guidelines supplement building, fire, and other health, safety and welfare codes, and represent practices APSU has adopted regarding the built environment. Where conflicts arise between codes and guidelines, codes take precedent. 3. Coordinate deviation from guidelines with the University Design and Construction (U) Department. COORDINATION 1. Selection of doors and hardware shall be coordinated with APSU locksmith, 931-221-7021. 2. Associate shall submit shop drawings to the locksmith for review prior to their approval. 3. All door slabs shall be machined off-site in the vendor or manufacturer s facilities. Associate shall place the following note conspicuously on the each sheet showing the door schedule and in the technical specifications: Door slabs and frames shall be ready for hardware installation before delivery to the work site. Door slabs and frames shall be machined at the vendor or manufacturer s facilities. 4. Location of rapid key entry vault shall be determined by APSU Office of Public Safety and the University locksmith. RELATED SECTION 1. 08 Openings DEMOLITION AND RENOVATION 1. Lock and door hardware removals shall be coordinated with APSU locksmith and U. All hardware removed shall be returned to the University locksmith office at its option. 08 71 00 DOOR HARDWARE GENERAL PROVISIONS 1. Supplier shall be an APSU approved dealer of Stanley CorMax. 2. Cores and keys shall be shipped directly to APSU from the factory. University Design And Construction (U) Appendix 4 Forms, Page 1 of 6

3. Unpinned cores shall be provided at a rate of 5% of the total number of locks and 1 blank key per core. 4. Prior to submitting shop drawings, successful hardware supplier shall make contact with APSU locksmith, 931-221-7021, to receive instruction pertaining to key symbols, master keys and final approval of individual lock function and hardware options. FINISH 1. For new construction and renovations impacting a majority of the building, hardware finish shall be 32D, satin stainless steel. 2. For renovations not affecting the entire building, match existing and adjacencies as closely as possible. 3. Associate shall ensure closers match finish and color of doors and frames. LOCKS & LATCH SETS 1. Use Stanley Best 9K37 15DSTK626 Series Heavy Duty Locks Levers. 2. Coordinate locking functions with APSU in situations where ones prescribed are inappropriate. 3. Each area shall receive the lock & latchsets functions below: Location 1. Offices, classrooms, conference rooms AB 2. Student rooms R 3. Single occupancy restrooms L 4. Mechanical & electrical rooms, D data rooms, custodial, storage rooms Function Code DEAD BOLTS 1. Double-cylinder (i.e., keyed on both sides) deadbolts shall not be used. 2. Dead bolt shall be full-motise, commercial grade, heavy duty with thumb turn lever with 2 ¾ backset. HINGES 1. Exterior, stairwell and corridor doors shall use heavy duty continuous hinges. 2. Low traffic doors 3 wide or less shall use full mortise 4 ½ x 4 ½ ball bearing, heavy duty, butt hinges with non-removable pin. 3. Doors wider than 3-0 shall receive heavy-duty continuous hinge. 4. Doors 7-2 and higher shall have 4 hinges; doors under 7-2 shall have 3 hinges. EXIT DEVICES University Design And Construction (U) Appendix 4 Forms, Page 2 of 6

1. Exit devices shall be stainless steel, heavy duty, rim-mounted and reversible from the following manufacturers: a. Von Duprin b. Precision c. Sargent 80 2. Exit paddles shall not be used. 3. Concealed verticle rod shall not be used. 4. Standard trim shall be similar to Von Duprin 992L-03 Location Stairwell with no lock and cannot be dogged down Stairwell with lock, or entrance in labeled opening where device cannot be dogged down during the day. Entrance with dogging and outside pull trim Entrance with dogging and outside pull trim and keyed cylinder Fire escapes or low occupancy classrooms with exit-only requirements Residence hall wide stile entrance doors with dogging and without cylinders Residence hall wide stile entrance-exit doors with dogging and cylinder Access control entrances Example Device VonDuprin 98L-F-BE VD 98L-F VD 98L-DT VD 98L VD EO-F VD 98L-DT (pull trim & blank escutcheon) VD 98L (pull trim & cylinder) VD 99EL (trim may vary depending on use of door) REMOVABLE MULLIONS 1. Removable mullions shall be used as a last resort. 2. If they are used they shall be: a. Keyed with removable core for Stanley Cormax. b. Galvanized steel, commercial grade, heavy duty, factory primed and painted to match adjacent doors. MISCELLANEOUS HARDWARE 1. Push/pull plates shall be stainless steel, and bolted through plate and door, 2..050 thick. 3. Toilet Rooms shall have 4 x 16 stainless steel plates. 4. Door stops shall be wall mounted when possible. 5. Kick Plates shall be stainless steel,.050 thick, 10 height. University Design And Construction (U) Appendix 4 Forms, Page 3 of 6

6. Door hold-opens shall be stainless steel. DIVISION 08 70 00 Hardware RAPID ENTRY SYSTEM 1. Rapid entry system shall be keyed to Stanley CorMax, recessed, similar to Knox Box brand, model 3275. AUTOMATIC DOOR OPERATORS 1. Door actuators shall be mounted at all public exterior double entrance doors. At the following locations: a. Pedestal or wall mounted at the exterior ± 3-0 from the face of the door and 1-0 beyond the door swing on the hinge side. b. Surface-mounted in a vestibule c. Surface-mounted inside the main space EXTERIOR PEDISTAL MOUNT VESTIBULE OR EXTERIOR ALCOVE MOUNT MAIN SPACE MOUNT 2. Actuators shall be radio frequency type. 3. Door opening shall be sequenced in vestibules to minimize inside/outside air transfer. 4. Actuators shall be 4 ½ in diameter, with the international symbol of accessibility, and PUSH TO OPEN. 5. Automatic Door Operators manufacturers: a. LCN 4642 b. Norton 6000 series low energy operator University Design And Construction (U) Appendix 4 Forms, Page 4 of 6

c. Besam SW100 low energy operator DOOR CLOSERS 1. Closers shall be overhead, surface mounted, parallel arm from the following manufacturers: a. Exterior and corridor applications: LCN 404 Hager 5200 Extra-duty arm Norton 8301 Extra-duty arm b. All other interior applications LCN 1461 Hager 5200 Norton 8301 2. Closers shall match finish and color of frames they are attached to. 3. Corridor and exterior doors shall be similar to LCN cush-n-stop. 4. Power assisted openers shall be similar to LCN 4642, with Auto-equalizer. 5. SEE NEXT PAGE FOR DOOR ACCESS IDENTIFICATION TABLE General Notes: 1. Often "Exits Only" also serve as emergency exits as defined by building code. The "Exit Only" is an operational designation meaning it is used for ordinary exiting in addition to having a required emergency exit device. Accordingly, a request to exit motion sensor is required. For doors that don't require an emergency exit device (Type ED & SD) only a Door Position Switch is required. University Design And Construction (U) Appendix 4 Forms, Page 5 of 6

DOOR ACCESS IDENTIFICATION TABLE Designation Designation Double EED 1 2 2 E3 M3 5 Exit Only, Double ED 2 Feb Exterior/Corridor Doors 1 2 E3 M3 4 5 Entrance/Exit Exit Only, Emergency Exit Device Required 1 Emergency Exit Only Single EES No Emergency Exit Device Required 1 Single SD 2 Double EXD 1 2 2 M3 M3 Double IND 1 2 2 4 5 Single EXS 1 2 M3 Single INS 1 2 4 5 Double Single EMD EMS 1 2 E3 5 2 2 M3 M3 2 M3 EL 5 Device Function Notes Request to Exit Motion Sensor Allows door to be exited without tripping an alarm Door Position Switch Sends signal that door has been opened w/o valid read or Electrified Lock (panic hardware, e.g., Unlocks and relocks door Von Duprin EPT2) Door is wired Non electrified Lock (panic hardware) Latches and relatches door Typically inactive leaf Fail Secure Electric Strike (mechanical Unlocks and relocks door Frame, inactive leaf or Reader Lenel (24V ) Exterior Doors Interior Doors Elevator NA END OF SECTION University Design And Construction (U) Appendix 4 Forms, Page 6 of 6

DOOR CONTACTS - 233 LEGENDS DR, SUITE 100 LEBANON, TN 37087 VOICE: 615.449.2944 FAX: 615.443.4454 DOUBLE DOOR - EED DOUBLE DOOR - EXD CARD READER (OPP. SIDE), 4" x 4" BACKBOX WITH SINGLE GANG PLASTER RING. SINGLE DOOR - EES (ON OPPOSITE SIDE) SINGLE DOOR - EXS CARD READER (OPP. SIDE), 4" x 4" BACKBOX WITH SINGLE GANG PLASTER RING. DOUBLE DOOR - ED (ON OPPOSITE SIDE) DOUBLE DOOR - IND DOOR CONTACTS - CARD READER, 4" x 4" BACKBOX WITH SINGLE GANG PLASTER RING. SINGLE DOOR - SD (ON OPPOSITE SIDE) SINGLE DOOR INS CARD READER, 4" x 4" BACKBOX WITH SINGLE GANG PLASTER RING. ELECTRIC STRIKE AUSTIN PEAY STATE UNIVERSITY Access Control - Door Details REX INSTALL NOTES: 1. CEILINGS UNDER 10' AFF - INSTALL IN CEILING 2. ANY CEILINGS OVER 10' AFF - INSTALL 6" DOOR FRAME, BACKBOX REQ'D KEY PLAN: PRELIMINARY CARD READER, 4" x 4" BACKBOX WITH SINGLE GANG PLASTER RING. DOUBLE DOOR - EMD SINGLE DOOR - EMS ELEVATOR DOOR - EL REVISIONS: NOTE: Drawings, symbols, and/or annotations may not be to scale, and are portrayed for representational purposes only. Actual sizes and/or design may differ. Any architectural drawings appear courtesy of their respective owners. DATE: 07/28/2015 PROJ. NUMBER: P00000 DRAWN BY: MRO PROJ. MGR: MBW SHEET TITLE: TELECOM - ACCESS CONTROL DOOR HARDWARE TELECOM - ACCESS CONTROL DOOR HARDWARE SCALE: NTS SHEET NUMBER: T4.1