HAU Series Controllers

Similar documents
Potentiometer Control EC20200

Sealed Interface Control: EC20300

Coils & Electronic Controls

DVC700 Series Programmable System Controller

DVC700 Series Programmable System Controller

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

DENISON HYDRAULICS Multi-Function Proportional Valve Dual Driver ( Encapsulated )

Apitech Valve Drive Board

FT201 PRODUCT MANUAL PART NUMBER: SG REVISION: A

Digital Interface Card DEC005000

DynaDrive INFORMATION MANUAL SDFP(S)

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Overview. Features. Specifications. Important Notes

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

ELECTRONIC REGULATOR FOR OPEN LOOP

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

Variable Speed Brushed DC Motor Drive

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

HT101V Reference Manual

Box chopper amplifier BOE

Installation & Operation Manual

Continental Hydraulics Installation Manual CEM-PA-A

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

Pic-Convert Board Instructions

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

HIGH PERFORMANCE CAR AMPLIFIER

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

Q: What does it mean if the RF generator will not put out full power and the reflected power is nearly equal to forward power?

MDSD (Series 2X) Mobile Dual Solenoid Driver

Single Ended Linear DC Servo Amplifier

Installation, Operation and Maintenance Manual

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

12V Victor 888 User Manual

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

INSTALLATION & OPERATION MANUAL

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Blue Point Engineering

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

INSTRUCTION MANUAL. Microseismic Data Logger. January 5, 2007, Revision 3

MODEL 25D MANUAL PRODUCT OVERVIEW:

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

TECHNICAL PRODUCT DATASHEET

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Analog Servo Drive 30A8

KX550.3 / KX KX Amplifier Features

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

RXA 1000 D CLASS D MONO AMPLIFIER USER S MANUAL

Analog Servo Drive 20A20

IA SERIES OWNER'S MANUAL

Owner's manual. ZX-series

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

DENISON HYDRAULICS Proportional Pressure Control Valves

GHS 20/20i handset. installation instructions

MODEL KBWD-15 Pulse Width Modulated (PWM)

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

MULTIMETER TRAINING UNIT QUICKSTART GUIDE

The system (EF-7700) consists out of two parts: the transmitter (EF-7602) and the receiver including wiring (EF-7701).

KX120.2 / KX150.2 / KX200.2

HANDY DRIVE HANDHELD CONTROL SYSTEM TO DRIVE THE

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

A400HLX A600HLX. Installation Assistance. Amplifier Installation and Operation

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Y1. Troubleshooting / Service Guide for SureFire PWM Liquid Application Systems. John Deere Rate Controller 2000

DSB810A Digital DC Servo Driver Manual V1.0

TEAM DIGITAL. SMC4 Servo & Motor Controller

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Microprocessor Control Board Set Up Procedures (OR PLC)

Analog Servo Drive 30A8

Analog amplifier RA. RE Edition: Replaces:

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

CLASS D MONOBLOCK AMPLIFIER DM1500, DM2500 OWNER S MANUAL

ADJUST AND SET UP FOR UNIT B

Analog Servo Drive 25A20DD

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Precision Voltage Control System

DM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018

Electro Controls. Input-Output Modules WattsIndustries.co.uk

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

R180. AVRs. Installation and maintenance

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Model 25D Manual. Introduction:

WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.

Instructions for Building the Pulsed Width Modulation Circuit. MC-12 (DC Motor Controller or PWM) From Electronic Light Inc. (revised kit 8/08)

Owner s manual & Installation manual Mode d emploi et manuel d installation Manual de instrucciones y de instalación XC6210 XC6410

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Model 25A Manual. Introduction:

MYKRO RM440.4 / RM740.5 / RM Installation Manual

Technical Service Bulletin DCX AGC Setup Procedure for ADAPT IV Exciters

9 db/oct, variable bass boost

ZVS Power Resonator. CRO-SM1 Ultra Compact Self Resonating Power Oscillator

Installation & Service Manual

Transcription:

Instruction, Installation and Operation Guide for: HAU Series Controllers Document Number: 021-00140 Document Revision: B.2 Document Issue Date: Document Creator: G.Gotting Document Creation Date: 4/21/2011 www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 1/10

HAU Single Coil Proportional Valve Driver Description: The HAU Valve Driver is a single coil proportional valve driver that provides precise control of a single coil proportional valve by controlling current through Pulse Width Modulation. The HAU will accept control inputs of 5V to +5V, 0 to +10V, 4 to 20 ma or an external potentiometer. It will accept power supply voltages from 11 to 30 volts DC and is able to drive coils with requirements up to 5 amps. Options include ramping, dither, waterproof potentiometers and WeatherPack connectors. Indicators: PWR LED PWM% Lights when the power supply voltage is above 10.5V. The unit will not function correctly if this lamp is off or blinking. Indicates the duty cycle to the coil by going from RED (full off) to GREEN (full on). The ratio of red to green gives a relative indication of current flow through the coil as an aid to tuning and troubleshooting. Wiring: Hook up the unit as shown in Figure 2, using only one of the three control input configurations. Use 16 AWG wire for power and coil wiring. Use shrouded coil connectors. Locate the fuse as close to the power supply as possible to protect the wiring and the valve controller. Fusing: Use only an ACG-5 fuse for current ranges up to 3.33 amps, or an ACG-10 fuse for 3.34 to 5.00 amp coils. Failure to properly fuse the unit invalidates the warranty. www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 2/10

Setup Procedure: Compare the part number on your unit to the Part Number Index in Figure 1 for an explanation of options specific to your unit. This controller is best adjusted by observing the system response. Coil current can be used, but coil voltage is not accurate. INITIAL SETUP: 1. Turn the MAX pot 10 turns CCW then 5 turns CW (set to center of pot) 2. Turn the MIN pot 10 turns CCW (off) 3. Turn all RAMP pots 10 turns CCW (off) 4. Turn the DITHER AMP pot 10 turns CCW (off) MAX / MIN: 1. Turn on power supply. 2. Set the control input to its minimum and adjust the MIN pot for the desired response. CW for more current, CCW for less. Set the control input to its maximum and adjust the MAX pot for the desired maximum desired response. Do not adjust the unit for more current then is required to fully shift the valve; this reduces the useful range of the controller and may harm the coil. 3. The Min and MAX pots interact with each other and system response may change as the system warms up. Warm the system to normal operating temperatures and repeat steps 2 and 3 until both the MIN and MAX pots are adjusted properly. www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 3/10

RAMP Adjustments (Optional): If the unit has one ramp potentiometer it will adjust the ramping function for both directions of control to the same setting. If the unit has two ramp potentiometers, RAMP UP will adjust the ramp time for current increases and RAMP DOWN will adjust for decreases in current. Ramp is adjusted by quickly switching the control input from minimum to maximum, or maximum to minimum and adjusting the corresponding potentiometer to obtain the desired speed of response. NOTE: CW adjustment of the potentiometers will increase the ramp time. Dither Adjustments (Optional) DITHER AMP: The dither amplitude potentiometer is set fully CCW (off) at the factory. Once the valve being driven is established, adjust the potentiometer CW increasing the dither amplitude until the desired level is reached then readjust the MAX and MIN potentiometers. DITHER FREQ: The dither amplitude may be pre-defined at time of order and if not, the frequency will be factory set to 140Hz. If the valve is changed or a different dither frequency is needed, adjust the potentiometer CW, increasing the frequency until the desired level is reached. www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 4/10

Troubleshooting: If the set up procedure does not achieve the desired results, double check the wiring and perform the following tests. Record the test results. Tools required: A battery operated multi meter and a small screwdriver are required. Check the power input: The card will not function correctly unless the +POWER to PWR COM voltage is at least 11 V. If this voltage is more than 30 V the card may be damaged. Check the control input you are using: Potentiometer input: Measure the wiper voltage between the VOLT and SIG COM terminals. With a 10 K ohm potentiometer, the wiper will go from 0 (minimum current) to 9 V. The difference in voltage should be more than 5 V from minimum to maximum. The voltage must not be less than 0 V or more than 10 V. Voltage input: The difference in voltage between the VOLT and SIG COM terminals should be greater than 5 V from minimum to maximum. The voltage must not be less than -5 V or more than +10 V. Current loop input: Measure the current into the CUR terminal. The difference in current should be at least 10 ma from minimum to maximum. The current must not be negative or more 20 ma. If a current meter is not available, measure the voltage from the CUR terminal to the SIG COM terminal and divide by 150 for an approximate reading. NOTE: Only one control input at a time may be connected. Verify the coil is not shorted: www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 5/10

If the +COIL to -COIL terminals are shorted, the valve driver will shut down its output until the short is removed. Disconnect the wires going to the +COIL and -COIL terminals and measure the resistance between the wires to ensure the coil is in good condition and within resistance range given by the manufacturer Check the card at full on & full off: NOTE: Do not try the full on test if the power supply is 50% higher than the coil's rated voltage. Temporarily disconnect all wires from the VOLT and CUR inputs. To test the card at full on, turn the MAX and MIN potentiometers 10 turns CW and temporarily connect the VOLT and REF terminals. Measure the voltage from +COIL to -COIL and from +POWER to PWR COM. The voltage difference should be no more than one volt if the card is operating correctly. To check the card at full off, disconnect the VOLT and REF terminals and turn the MAX potentiometer 10 turns CW and the MIN potentiometer 10 turns CCW. The +COIL to -COIL voltage should be zero. If the valve won't fully shift: If the card passes the "full on test" above, the problem maybe in the electrical system. Command the valve to full output. Measure the modules supply voltage at the main DCV power supply or battery source and then measure the voltage across the controllers +PWR and GND terminals. Compare these readings, they should be within 0.5V of each other, If there is excessive voltage drop in any of those wires i.e. >1V, they should be shortened or replaced by bigger wires. Bad frame 0V (GND) connections can cause large voltage drops and operational interruption. www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 6/10

When the coil heats up in use, it increases its resistance. Most coils will still be able to draw sufficient current to fully shift the valve if their rated voltage is supplied to the card and the card on maximum output causes less than 1V drop. When this is not the case, you must use a coil rated for less voltage or increase the power supply voltage. The card will have no trouble driving a 12 V coil from a 24 V supply, or a 10 V coil from a 12 V supply for example. You may need a new controller if the new coil draws more current than the controller is able to supply, based on the current range decided when ordered. If the valve shift is erratic: Electrical interference on the command signal control lines can cause erratic behavior if it is strong enough i.e. high wattage CB or Walkie-Talkie being used near the installation. Try changing the routing of the control wires to see if the problem changes. Power supply interference or brown outs can also cause erratic behavior. Test for this by running the card off its own fully charged battery. Controller Mechanical Details: 1.46 I Max I Min Ramp UP PWR PWM% All dimensions in inches Notes: 0.64 0.31 Ramp DOWN Dither Amp Dither Freq VRef Volt HAUKRF140 Serial # D0000x Cur SIG Com 2.30 PWR Com -Coil +Coil +Power 2.00 0.51 2.82 Unit weight is approx. 350 grams Mounting is via 3 x No. 8 holes ( 4.5mm ) on to flat surface Unit shown with ALL potentiometers possible ALL potentiometers are 10 turn variety with end clutch 1.15 2.92 www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 7/10

Controller Connection Information: NOTE: Use AGC5 fuse up to 3 amps and AGC10 upto 5 amps 3.500 3.000 Measured Coil Current Expected Coil Current 2.500 Coil Current 2.000 (Amps) 1.500 1.000 0.500 1.000 2.000 3.000 4.000 5.000 6.000 7.000 8.000 9.000 10.000 Control Voltage (Volts) The HAU series of controllers has a very linear command input to current output curve to ensure the best flow or pressure characteristic is achieved from the product being driven. Housing Type:- HCT unique encapsulated block. Input Supply Voltage: 11 30VDC ( Absolute Maximum ) Input Supply Current: Valve Current Setting + 200mA Quiescent (Max) Command Input Type(s): Voltage *Vdc) OR current (ma) Command Input Value(s): 0 to +5V, 0 to +10V or 0 to 20mA Proportional Output: 1x PWM up to 5A max current Dither Frequency : ~30 to 200Hz ( adjustable ) Dither Amplitude: ~0 to 100% ( adjustable ) Housing Material:- Black, Polycarbonate potting case Wire Connections:- 8 way Terminal block with Weatherpack connectors as Q option Connector type:- Screw terminals ( standard ) Encapsulation:- Flameproof, 2 part epoxy resin - black Mounting:- 3 x No. 8 ( 4.5mm ) screws. Temperature range:- -20 to +60ºC ( operational ) NEMA/IP Rating: NEMA 6P/68 ( Module only ) derate for connector as required. www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 8/10

Key Code Ordering Information: H A U K R F 1 4 0 - Max. Current Range: Z = 0mA to 500mA E = 0mA to 1A K = 0A to 1.7A G = 0A to 3A M = 0 to 5A Ramp Select: S = Single pot. adjustment f or up & down R = Indiv idual adjustments f or up & down Dither Frequency Pre-set by factory: N = NO dither f requency potentiometer installed Fxxx = Pre-set to user chosen dither f requency xxxhz Frequency is in Hertz, use all three digits with leading 0 if required: i.e. 050 f or 50Hz or 152 f or 152Hz NOTE: If NO dither f requency is specified, the def ault is 140Hz Connector Type: NO Letter ( i.e. Blank ) = Standard screw ty pe terminal block Q = WeatherPack option - 4 way tower and 4 way shroud on 6 inch cables will be prov ided. www.hctcontrols.com 021-00140_HAU_User_Guide_Rev_Bp2 9/10

Mining & Exploration Agriculture Cranes & lifts Refuse & Recycling Construction Off-Road vehicles Forestry, Wood & Pulp Reclamation & Salvage Oil Field & Sands Demolition Equipment Cooling Solutions Military Apparatus Specialty Use Remote Control Power Generation Emission Controls Integrated Drivers Valve & Pump Controls HCT Product Sales and Support: For a full list of authorized distributors worldwide, please visit: www.hctcontrols.com/distributors/index.htm To discuss anything in this brochure, order product, get price and delivery or book a training course, please contact our customer service department through E-mail at: info@hctcontrols.com www.hctcontrols.com www.hctcontrols.com 10/10 021-00140_HAU_User_Guide_Rev_Bp2