USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Similar documents
USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 1186 Multi-Mode Fiber Modem with Fixed G.703/G.704 Interface

ACT-IR220Li/220LN IrDA Serial Port Adapter

ACT-IR220L/LE IrDA Serial Port Adapter

Field Hub Installation Guide. P/N Rev. C 05/15

CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca FLEX SERIES UNIVERSAL CONTROLLER

Easy-Link Plus Version 2.2

User Manual. ProRF Encoder Transmitter & Receiver

Transmitter. User Manual. Firmware version 1.0 and greater

RFTX-1 Installation Manual

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

PTT- Z or PTT-U PUSH-TO-TALK Specification

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Quick-Start Guide. M7 Series DATA RADIO MODEM

Fanuc Serial (RS232) Communications Information

GPS140 DOS Application User s Manual Version 1.0.x

500S Smart Antenna Installation and Operation Manual. P/N Rev. A 09/17 E29808

RM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01

ISTATION-N (Integration Station) User Manual

f i r e - p a r t s. c o m

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

USER'S MANUAL. Model : K

AMP-13 OPERATOR S MANUAL

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

GREEN HERON ENGINEERING LLC

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

301 & 601 Mic/Line Mixers Operation Manual

AIS 300 Installation Instructions

Color WHI, 455, 530 WHI, 455, 530 WHI, 455, 530. Up to 2 meters (80 ) long C rated PVC jacket, foil shield with drain.

GM8036 Laser Sweep Optical Spectrum Analyzer. Programming Guide

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

User s Guide FM Transmitter

Model RTX-12 Radio Modem

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

Ditch Witch 750 Tracker Specs Provided by FOREWORD

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

1 What s in the shipping package?

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Myriad MD9612FP Flash Poll Rack-Mount Modem User s Guide MD9612FP USER S GUIDE XXX Page i REV. A

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

WIRELESS BLUETOOTH AUDIO TO ANY CAR RADIO MAKE THE CONNECTION

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

RE-S1 Operator s Manual

VideoEase Component Video Hub (500250, , , ) Installation Guide

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

Preliminary Data Sheet!

TIA-4000 Optical/Electrical Converter. Operating Instructions

Integrity Instruments

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

TIA-952 Optical/Electrical Converter. Operating Instructions

Active CCTV Receiver Balun Installation Guide

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est.

Everything will be securely inserted inside the box so items do not shift during shipping and handling. Rev D 2

Broadband Step-Up Transformer. User Manual

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

MDW-45 Converter RS RS-422/485

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

Instruction Manual. SainSonic AX-7C FM Transmitter III. So in SONIC

M2M. Overview. volts DC. AC power.

Guide. Installation. Wilson Electronics, Inc. Direct Connection High Power iden Amplifi er 800 MHz Band. Contents:

Disclaimers. Important Notice

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca FLEX SERIES UNIVERSAL CONTROLLER

Appearance of device and accessories may vary.

LTX-5520 Electrical / Optical Converter Operating Instructions

AMP-12 OPERATOR S MANUAL

The NES Files

INSTALLATION INSTRUCTIONS

SMC-32A. Serial Stepping Motor Driver/Controller

FinishLynx Interface. Includes: Power requirements: 9 VDC Power Adapter (included) Size: Approximately 5 x 3 x 2 Approximate weight: 5.57oz.

Model: 5010 INSTALLATION AND OPERATING INSTRUCTIONS

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2

Owner s Manual. MRX-2 Network Base Station

PDL Base. Radio Modem User's Guide. Revision 0.2 (preliminary) May 1999 Copyright 1999 Pacific Crest Corporation Document M00522

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

PULSE OXIMETRY SIMULATOR

Document # Rev. C October, GEMINI EXPRESS MULTIPLEXER User s Guide

Data Acquisition Modules/ Distributed IO Modules

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

CAUTION - ELECTRIC TOY:

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

INSTALLATION AND SETUP GUIDE

The NES Files

Uplink 5500EZ. Installation and User Guide. S e pte m be r 1 2,

Operator s Manual. PP016 Passive Probe

Model WM1000/WM2000. Wall Mount Intercom Stations. User Instructions

Transcription:

USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 2029 components to be free from defects, and will at our option repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. 1.1 RADIO AND TV INTERFERENCE The Model 2029 generates and uses radio frequency energy, and if not installed and used properly that is, in strict accordance with the manufacturer's instructions may cause interference to radio and television reception. The Model 2029 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 2029 does cause interference to radio or television reception, which can be determined by disconnecting the RS-232 interface, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). 1.2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support. 1

1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or, support@patton.com. NOTE: Packages received without an RMA number will not be accepted. Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 2029. Technical Support hours: 8AM to 5PM EST, Monday through Friday. 2

2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007. 2.1 FEATURES Converts parallel data to serial data and vice versa Automatically selects parallel-to-serial and serial-to-parallel operation Serial data rates to 38,400 bps No AC power required Supports both software and hardware flow control A five-state LED monitors status and diagnostics Ultra-miniature size A DB-9 female and a Centronics male connector Made in the U.S.A. 2.2 DESCRIPTION The Patton Model 2029 Parallel to Serial Converter automatically converts RS-232C serial data to parallel data format and vice versa. Incorporating advanced microprocessor technology, the Model 2029 is able to automatically sense and select parallel and serial modes. Requiring no AC power, the Model 2029 supports serial data rates to 38.4 Kbps. For easy configuration, the Model 2029 features a convenient set of external configuration switches. These accessible configuration switches allow the user to control baud rate, parity, word length and flow control. An easy-to-read LED indicator displays status and operating condition. Housed in an ultra-miniature ABS plastic case, the Model 2029 measures only 2.68 x 1.25 x.75. The Patton Model 2029 comes equipped with a DB-9 female connector on the serial side and a Centronics 36 pin male connector on the parallel side. A 6-foot integral cable is also included. 3

3.0 CONFIGURATION The Model 2029 is simple to install and designed for excellent reliability. The following instructions will help you set up and install the converter properly. If you have any questions, please call Patton Technical Support at (301) 975-1007. 3.1 CONFIGURATION SWITCHES The Model 2029 uses a set of eight external DIP switches (see Figure 1) that allow configuration to a wide range of applications. Because all eight switches are in one externally accessible DIP switch package, there is no need to open the case for configuration. The configuration switches allow you to select data rates, parity, word length and flow control selection. The following section describes all switch locations, positions and functions. Configuration Switch Complete Status LED Figure 1. The location of the configuration switches The Model 2029 uses a miniature configuration switch package. To configure your unit, use a small screwdriver and gently push each switch to its proper setting. The ON and OFF positions are shown in Figure 2. Default settings for the DIP switches are shown in the table on the following page. Detailed settings follow the table. 1 2 3 4 5 6 7 8 OFF DHS-8 Figure 2. The miniature configuration switch package 4

DIP SWITCH SUMMARY TABLE Position Function Factory Default SW1 Flow Control Off Hardware SW2 LED Indicator On Enabled SW3 Data, Parity, Stop Bits Off SW4 Data, Parity, Stop Bits Off 8B, NP, 1S SW5 Data, Parity, Stop Bits Off SW6 Data Rate Off SW7 Data Rate Off 9600 bps SW8 Data Rate Off 3.2 DETAILED SWITCH SETTINGS } } This section provides detailed information about the function of each DIP switch and lists all possible settings. Switch 1: Hardware/Software Control The setting for Switch 1 determines whether these interface converters will control either hardware or software flow control. Flow Control Hardware Software SW1 OFF ON Switch 2: Enable/Disable the LED Indicator The setting for Switch 2 determines whether the LED indicator is enabled or disabled. LED ON OFF SW2 ON OFF 5

Switch 3 through 5: Data, Parity and Stop Bit Switches 3 through 5 are used to specify the data, parity and stop bits. The following table shows the settings that may be used: Stop Data Parity Bit SW3 SW4 SW5 7B EP 1S ON ON ON 7B OP 1S OFF ON ON 7B NP 2S ON OFF ON 7B EP 2S OFF OFF ON 7B OP 2S ON ON OFF 8B EP 1S OFF ON OFF 8B OP 1S ON OFF OFF 8B NP 1S OFF OFF OFF Switches 6 through 8: Frequency and Data Rate Switches 6 through 8 determine the frequency and data rate. The following chart shows the settings that may be used: Model 2029 Data Rate SW6 SW7 SW8 300 OFF OFF ON 600 ON OFF ON 1200 ON ON OFF 2400 OFF ON ON 4800 ON ON ON 9600 OFF OFF OFF 19200 ON OFF OFF 38400 OFF ON OFF 6

4.0 INSTALLATION The Patton Model 2029 is very simple to install. Once you have configured the DIP switches, just plug it in like a normal cable and you're ready to go. Figure 3 illustrates the proper connections for the standard cables. If you have special-ordered a non-standard connector, your connections may be different. Model 2029 Printer PC Figure 3. Installing the Model 2029 7

5.0 OPERATION Once your interface converter is properly configured and installed, it should operate transparently as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no ON/OFF switch. 5.1 LED STATUS MONITORS The Model 2029 features an easy-to-read status LED that glows red to indicate the condition of the transmission line. Figure 1 shows the location of the LED. The following chart describes the LED's various functions. LED Codes Computer is sending data Serial device is connected; computer is not sending data Both serial and parallel devices are connected; computer not sending data The red LED indicator blinks to show data activity. However, since there is only one indicator, it uses different LED codes to demonstrate various messages. The following chart describes these codes: Key: Blink Short pause Long pause 8

APPENDIX A PATTON MODEL 2029 SPECIFICATIONS Interface: Connectors: Cables: Data Rates: LED: Power Supply: Data Format: Asynchronous., RS-232C compatible Serial, DB-9 female; Parallel, Centronics male Six foot integral cable 0-38,400 Kbps LED displays status and operating condition No external power required; uses power from RS-232 interface 7 or 8 bits; 1 or 2 stop bits; even, odd or no parity Temperature Range: 0-60 C (32-140 F) Altitude: Humidity: 0-10,100 feet 5 to 95% non-condensing Dimensions: 2.68 x 1.25 x.75 Weight: 2 oz. (56.8 grams) 9

APPENDIX B PATTON MODEL 2029 INTERFACE CONNECTIONS Model 2029 Centronics Strobe (Output)-1 Data bit 0 (I/O)-2 Data bit 1 (I/O)-3 Data bit 2 (I/O)-4 Data bit 3 (I/O)-5 Data bit 4 (I/O)-6 Data bit 5 (I/O)-7 Data bit 6 (I/O)-8 Data bit 7 (I/O)-9 Acknowledge (Input - active low)-10 Busy (Input - active high)-11 Paper End-12 Select-13 14 No Connect-15 16 17 +5 volts-18 19-Ground 20-Ground 21-Ground 22-Ground 23-Ground 24-Ground 25-Ground 26-Ground 27-Ground 28-Ground 29-Ground 30-Ground 31 32-Error 33-Ground 34 35 36-Ground Model 2029 DB-9 Interface Data Set Ready (DSR) - 6 Ready to Send (RTS) - 7 Clear to Send (CTS) - 8 External Power - 9 1- Carrier Detect (CD) 2- Receive Data (RD) 3- Transmit Data (TD) 4- Data Terminal Ready (DTR) 5- Signal Ground/ Frame Ground (SG/ FG) 10

APPENDIX C PATTON MODEL 2029 BLOCK DIAGRAM Copyright Patton Electronics Company All Rights Reserved 11