TEST REPORT Metallic materials - Tensile testing (traction test) at room temperature

Similar documents
Bellaterra: File number: 15/ Via Bellavista Pallejà. Humitat Stop S.L.

Preload Measurement and Comparison of Structural Bolts sets installed in Steel Connections with and without Direct Tension Indicators

ISO 783 INTERNATIONAL STANDARD. Metallic materials Tensile testing at elevated temperature

Product Information. makroxtens II

REPORT ON THE ON-SITE ACOUSTIC MEASUREMENTS CARRIED OUT TO CALCULATE THE ACOUSTIC INSULATION OF THE WEWORK+ CABIN

Contents DIN 50125:

TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

Universal Sheet Metal Testing Machines. for Research, Development and In-process Testing

Initial wet-web tensile strength, stretch and tensile energy absorption

Test Report No.: /k-e Date: PMMA-sheets PLEXIGLAS SOUNDSTOP GS CC for. Impact test according to pren :2002; Annex B

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

THIN-WALLED HOLLOW BOLTS

Proposal for new standard. Determination of interface friction between painted parts. Orientation. p. 1 (15) Draft1, Revised

Bolts and Set Screws Are they interchangeable?

DIGITAL PANEL METER N24 AND N25 METER SERIES

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

Instruction manual. ZCY 2400 Zehntner-Cylindrical mandrel tester

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

CTAG:b01ac469edcbee4d9e5f84a83a1962a5 Certificate of Calibration

GESTER. Universal Testing Machine (Dual Column) GT-K01. Product Presentation. Application. Test Sample.

English version. Steel and steel products Location and preparation of samples and test pieces for mechanical testing (ISO 377:1997)

Universal Sheet Metal Testing Machine Model 142

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Final Publishable Summary

ADVANCED. Universal Sheet Metal Testing Machine Model 142

TECHNICAL INFORMATION P10/0513 vitroflex LED EDGELIGHT features

SEI Certification Program Manual

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

SSAB Laser OPTIMIZED FOR YOU AND LASER CUTTING

The Formability of Perforated Metals, Part II: Stainless Steel and Aluminum

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

A NEW MOTION COMPENSATION TECHNIQUE FOR INFRARED STRESS MEASUREMENT USING DIGITAL IMAGE CORRELATION

testo 735, highly accurate alarm and logger thermometer with measurement site management

Metallic materials Sheet and strip Method for springback evaluation in stretch bending

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

COMITÉ EUROPÉEN DES ASSURANCES

TESTS REPORT n. 220.I EN.02

Instruction Manual for installing

6 Audio Broadcast PER 528

LED Driver Constant voltage

Instruction Manual for installing

Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and With Welding

Elcometer Conical Mandrel Bend Tester

Materials. Density, Hooke's law, Young modulus. 174 minutes. 174 marks. Page 1 of 29

European Technical Assessment ETA 15/0029 of 12/06/2017

Sheet Metal Testing Machine Model 134

N24, N25 DIGITAL PANEL METER

Test Report COMPRESSION TEST ON COLD-FORM STEEL MEMBERS

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

Strain Measurements with the Digital Image Correlation System Vic-2D

Chemical composition. Type 2 as per F568: C ( ); P (max 0.048); S (max 0.058); Mn (min 0.74); B (min );

LED Driver Constant voltage

BBD7267 Version 1 PRIEVIEW COPY ONLY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

5 m-measurement system for traceable measurements of tapes and rules

Fatigue crack propagation in uniaxial loading and bending fatigue in 20 khz testing. Mohamed Sadek PhD Student Karlstad university

SOLARLOK PV BAR Junction Box

Internal threaded version: HSC-I carbon steel internal version HSC-IR Stainless steel version (A4) Hilti anchor design software

Ultrasonic Bolt Load Measurement

LED Driver Constant voltage

DOWEL ACTION OF TITANIUM BARS CONNECTING MARBLE FRAGMENTS AT DIFFERENT ANGLES

Improving Edge Quality in Film Applications with Tangent Shear Slitting

CARES Technical Approval Report TA1-B 5042

Dowel connections in laminated strand lumber

The surveillance test is a physical inspection of the product and a comparison with the specifications of the original type tested sample.

The Bombay Textile Research Association, L. B. S. Marg, Ghatkopar (West), Mumbai, Maharashtra. Discipline Mechanical Testing Issue Date

Testing of friction properties of fasteners

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

Development of an Embedded Sensor Holder for Concrete Structures Monitoring

Micro IRHD Laser revolution

S-BT screw-in stainless steel and carbon steel threaded studs

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

TESTRANSFO2 User s Guide

Instruction manual ZSH 2090


PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

Handling and Electrical Contacting of Piezoceramic Components

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

Certified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy

SOUTH AFRICAN NATIONAL STANDARD

Tests according to standard UNE EN 14465:2004 / A1:2007: TEXTILE UPHOLSTERY FABRIC. Specification and method of test

TEST REPORT EN 62233: 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

Double Shear Testing of Bolts

LED Driver Compact dimming

Tested and ready to use Quality from a single-source

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

Steel Gauge Block Sets Page 341. Steel individual Gauge Blocks Page 348. CERA Gauge Block Sets Page 350. CERA Individual Gauge Blocks Page 353

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

MOY/SCMI/60 SPECIFICATION OF ACCURACY FOR VEE PIECES FOR EXTERNAL SCREW THREAD MEASUREMENT

Copyright. Michael Joseph Gilroy. May 1997

ISO 7438 INTERNATIONAL STANDARD. Metallic materials Bend test. Matériaux métalliques Essai de pliage. Second edition

T e s t R e p o r t. Page 1 of 6

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Certificate of Accreditation

Datasheet. Variable Impact Tester. Elcometer 1615

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

UPDATE TO STANDARD EN 388 GLOVES GIVING PROTECTION FROM MECHANICAL RISKS

Securifor Polyester Coated Welded Mesh Panels

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Transcription:

LGAI Technological Center, S.A. Campus UAB s/n Ronda de la Font del Carme, s/n E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 567 20 01 www.appluslaboratories.com Bellaterra: June 19, 2015 Report number: 15/9715-99 Petitioner reference: PAGOUNI, S.A. 9th km Old nat. road Thessaloniki Veria ECHEDOROS THESSALONIKI, PC 57008 (Greece) TEST REPORT Metallic materials - Tensile testing (traction test) at room temperature This document may only be reproduced in full. Only reports with an original signature on their respective certified copies will be legally valid. This document has 7 pages. This is the 1 st page. LGAI Technological Center S.A. Inscrita en el registro Mercantil de Barcelona, Tomo 35.803, Folio1, Hoja Nº B-266.627 Inscripción 1ª C.I.F. : A-63207492

Report number: 15/9715-99 Page number 2 of 7 Table of contents 1.- RECEIVED MATERIAL... 3 2.- REQUESTED MATTER... 3 3.- TEST METHOD... 3 3.1.1.- Sampling method... 3 3.1.2.- Test description... 4 3.1.3.- Testing equipment... 4 4.- TESTING CONDITIONS... 5 5.- RESULTS... 5

Report number: 15/9715-99 Page number 3 of 7 RECEIVED MATERIAL Six (6) samples with the reference that appear in Table 1, as claimed by the petitioner Table 1. Received material references. Ref. Applus Customer identification Sample description MEC 15/0296_1 MEC 15/0296_2 MEC 15/0296_3 MEC 15/0297_1 MEC 15/0297_2 MEC 15/0297_3 DOMOLAM PANELS 0.35mm DOMOLAM PANELS 0.35mm DOMOLAM PANELS 0.35mm DOMOLAM PANELS 0.40mm DOMOLAM PANELS 0.40mm DOMOLAM PANELS 0.40mm Date of material receipt: May 15, 2015 1.- REQUESTED MATTER Mechanical characterisation, specifically, tensile testing (traction test) at room temperature on standardised specimens taken from each receipt reference, according to standard UNE-EN ISO 6892-1:2010. 2.- TEST METHOD 2.1.1.- Sampling method The samples have been selected and delivered by the petitioner. Reference of the test specimen dimensions were determined according to Annex B and D of the standard UNE-EN ISO 6892-1:2010, which makes reference to the types of test specimens used for thin products: steel sheet, strips and flat products with thickness between 0,1mm and 3 mm, respectively. In figure 1 test sample used and the machining dimensions is shown.

Report number: 15/9715-99 Page number 4 of 7 Figure 1. Sketch and dimensions of the traction specimen test. 2.1.2.- Test description The traction test was conducted in accordance with the applicable paragraphs of standard UNE-EN ISO 6892-1:2010. Tests were conducted under displacement rate control, at a speed of 1,4 mm min -1 up to a 2% deformation. From this point to failure test was perform in displacement control at a rate of 4 mm min -1. 2.1.3.- Testing equipment For conducting the tensile tests on standard samples were used the following equipment: Tests were performed in a universal test machine, MTS, model 810 and serial number 099334, with a capacity of 100 KN and class 0.5, standard ISO 7500-1:2006, on a calibrated range of 100 KN. Deformation of tests samples was measured continuously during the test, using an MTS extensometer; model 632.12F-20 and serial number 1390, measuring 25 mm in initial length, with maximum opening to traction, 12.5mm. The initial section of the sample and the elongation at break were calculated by measuring several times the thickness, width and the distance between the marks, by means of a MITUTOYO digital caliper, model 500-311 and serial number 31819, with 150 mm of range.

Report number: 15/9715-99 Page number 5 of 7 3.- TESTING CONDITIONS The test was performed at an ambient temperature of 22 ± 1 C. 4.- RESULTS Performed test days Start: June 16, 2015 End: June 16, 2015 Further to conducting the traction test according to the instructions in the Test Method section, the results of nine specimens as requested by the petitioner are summarized in Tables 2-3 and Graphics 1-2: Table 2. Resume traction test results for specimen MEC 15/0296. Probeta E R p0,2 R m A 15 [GPa] [MPa] [MPa] [%] MEC 15/0296_1 164 230 252 29.3 MEC 15/0296_2 164 233 257 36.3 MEC 15/0296_3 162 230 254 39.8 Promedio 163 231 254 35.1 Desvest. (%) 0.53 0.79 1.05 15.20 Table 3. Resume traction test results for specimen MEC 15/0297. Probeta E R p0,2 R m A 16 [GPa] [MPa] [MPa] [%] MEC 15/0297_1 186 301 321 27.3 MEC 15/0297_2 164 303 322 29.5 MEC 15/0297_3 181 304 325 29.5 Promedio 177 302 323 28.8 Desvest. (%) 6.44 0.55 0.58 4.41 The tests have been conducted may be deemed valid, since the break occurred in the calibrated length and exceeded the minimum distance to the clamps, in accordance with standard UNE-EN ISO 6892-1:2010. The expanded uncertainty of measurement has been expressed as the relative standard uncertainty of measurement multiplied by a factor k = 2 which for a normal distribution corresponds to a coverage probability of approximately 95%.

Report number: 15/9715-99 Page number 6 of 7 Graphic 1. Curve Stress (MPa) vs. Deformation (%) registered at traction test for specimen MEC 15/0296. Graphic 2. Curve Stress (MPa) vs. Deformation (%) registered at traction test for specimen MEC 15/0297.

Report number: 15/9715-99 Page number 7 of 7 Raúl Navarro Garcia Technical Manager Mechanical Testing Laboratory LGAI Technological Center S.A. Results are exclusively related to the specimens, products or materials received by the Laboratory, which are fully described in the corresponding report item and to the testing conditions described in this test report Service Applus+, Quality guarantees Assurance that this work has been made in accordance with our Quality and Sustainability System, fulfilling the contractual conditions and legal norms. Within our improvement program we would be grateful if you would send us any commentary that you consider opportune, to the person in charge who signs this document, or to the Quality Manager of Applus+, in the following e-mail address: satisfaccion.cliente@appluscorp.com