A BALUNS AND BEADS REFLECTION BRIDGE 50 KHz to 1.5 GHz Sam Wetterlin 10/21/08

Similar documents
The Active Bridge 11/20/09

Measuring Impedance With Return Loss Bridge Sam Wetterlin 11/29/08

Return Loss Bridge Basics

1000BASE-T1 EMC Test Specification for Common Mode Chokes

Overview of the MSA 12/30/10

Measuring the output impedance for a live PA stage

Illustration of Plane Extension for the MSA 10/21/09

RBW FILTER SWITCH BOARD FOR THE MSA Sam Wetterlin 5/30/10 (modified 9/9/10)

A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09

The Practical Limitations of S Parameter Measurements and the Impact on Time- Domain Simulations of High Speed Interconnects

WI-FI/BLUETOOTH & PCB TUNING AND ANTENNA TESTING

Experiment 03 - Automated Scalar Reectometry Using BenchVue

A Walk Through the MSA Software Vector Network Analyzer Reflection Mode 12/12/09

Equivalent Circuit Determination of Quartz Crystals

Aries Kapton CSP socket

Vector Network Analyzers. Paul Coverdale VE3ICV

The 2-Port Shunt-Through Measurement and the Inherent Ground Loop

MFJ-219/219N 440 MHz UHF SWR Analyzer TABLE OF CONTENTS

Aries QFP microstrip socket

Novel Method for Vector Mixer Characterization and Mixer Test System Vector Error Correction. White Paper

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

CHQ SERIES. Surface Mount Chip Capacitors: Ultra High Frequency

Features and Technical Specifications

Differential-Mode Emissions

Top View (Near-side) Side View Bottom View (Far-side) ± ±.08. 4x.28. Orientation Marker Balanced port 1.

AUTOMOTIVE ETHERNET CONSORTIUM

Hot S 22 and Hot K-factor Measurements

NATIONAL UNIVERSITY of SINGAPORE

Preamplifier Options for Reducing Cable-Braid Loop Error

Bill Ham Martin Ogbuokiri. This clause specifies the electrical performance requirements for shielded and unshielded cables.

1-Port USB VNA - R60 Extended Specifications

VVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies

But this is about practical experiments so lets find out what an inductor is all about.

Features and Technical Specifications

Aries CSP microstrip socket Cycling test

Top View (Near-side) Side View Bottom View (Far-side) .89±.08. 4x.280. Orientation Marker Orientation Marker.

Compact VNA - TR1300/1

Description RF Explorer RFEAH-25 1 is a 25mm diameter, high performance near field H-Loop antenna.

Aries Center probe CSP socket Cycling test

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

5 ESSENTIAL HINTS TO IMPROVE Millimeter-wave Network Analysis

M5090. Extended Specifications EXTEND YOUR REACH TM

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

Microwave Metrology -ECE 684 Spring Lab Exercise T: TRL Calibration and Probe-Based Measurement

Using DDS Aliases to Extend the Frequency Range

TileCal Analogue Cable Measurement Report

Aries Kapton CSP socket Cycling test

SNA Calibration For Use In Your Shack

Improving Amplitude Accuracy with Next-Generation Signal Generators

High-Power Directional Couplers with Excellent Performance That You Can Build

Demo Circuit DC550A Quick Start Guide.

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

Applying and Measuring Ferrite Beads, Part III ~ Measurements Kurt Poulsen, Tom Hagen and Whitham D. Reeve

Simulating the 40 db Tap Attenuator

How the Braid Impedance of Instrumentation Cables Impact PI and SI Measurements

Field Measurements of Return Loss

Novel Modeling Strategy for a BCI set-up applied in an Automotive Application

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Agilent AN Applying Error Correction to Network Analyzer Measurements

Preamplifiers for Callisto Solar Radio Spectrometer

RF Characterization Report

UFL and Balanced Connectivity & Calibration Kit Overview

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Cobalt Series 20 GHz EXTEND YOUR REACH TM

VSWR MEASUREMENT APPLICATION NOTE ANV004.

Description RF Explorer RFEAH-25 1 is a 25mm diameter, high performance near field H-Loop antenna.

Differential Signal and Common Mode Signal in Time Domain

Conversion Gain Measurements on Mixers with Different Input and Output Impedances

Cu 0.37 Brass Cu 0.37 Brass

Fast network analyzers also for balanced measurements

PVD5870R. IQ Demodulator/ Modulator IQ Demodulator/ Modulator

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Agilent How To Accurately Evaluate Low ESR, High Q RF Chip Devices. Application Note

Jacques Audet VE2AZX. Nov VE2AZX 1

SWR/Return Loss Measurements Using System IIA

FIBRE CHANNEL CONSORTIUM

Data sheets CDN-M, CDN-AF, CDN-S, CDN-T, CDN-RJ, CDN-USB

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

DC-coupled directional bridge front-end for vector network analyzer receiver in GHz-range

Technologies Vector Reflectometers

Adjust Antenna Tuners Antenna Measurements Capacitor Measurement Measure Feed Point Impedance Measure Ground Loss Inductor Measurement

(a) The insertion loss is the average value of the transmission coefficient, S12 (db), in the passband (Figure 1 Label A)

Implementation of the EDGES Antenna Simulator

Understanding Power Splitters

White Paper MHz RF Amplifier Design

High Voltage Differential Probe

Application Note 5525

Battery Impedance Measurement

Investigation of the Double-Y Balun for Feeding Pulsed Antennas

Common myths, fallacies and misconceptions in Electromagnetic Compatibility and their correction.

Testing Power Sources for Stability

MPC5606E: Design for Performance and Electromagnetic Compatibility

Measurements 2: Network Analysis

Radiated noise measurement example using Tekbox TEM Cells

MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Keysight E5061B ENA Vector Network Analyzer CONFIGURATION GUIDE

Circuit Characterization with the Agilent 8714 VNA

Advanced Test Equipment Rentals ATEC (2832)

Yana Dongles Tom Berger K1TRB (c)2016 v171227

Transcription:

A BALUNS AND BEADS REFLECTION BRIDGE 50 KHz to 1.5 GHz Sam Wetterlin swetterlin@comcast.net 10/21/08 This article presents a reflection bridge useful from 50 KHz to the neighborhood of 1.5GHz. This bridge may be used in conjunction with a vector network analyzer (VNA), in which case the use of OSL calibration makes its performance about as good as one could want. It may also be used without calibration as a free-standing bridge, as discussed below. It was designed primarily to be used with Scotty s Spectrum Analyzer with the VNA option. The schematic of the bridge is shown in the Appendix. It consists of three parts. The first part is an input attenuator, resistive bridge, and Mini-Circuits TC1-1-13M balun, all on a single PCB. The second part is a homemade balun made with UT-47-FORM, two ferrite beads and a toroid. RG-316 could also be used, but may not have as good performance at high frequencies. This balun is terminated at the second PCB, which contains an attenuator and output connector. The finished bridge is shown in Figure 1. Figure 1 Assembled Bridge DUT at top, output at lower left, input at lower right The toroid is wrapped in tape because it is very conductive. The enclosure is approx. 4 x2 x1 Theory of Operation This bridge is a standard resistive bridge, using two 49.9 ohm resistors (close enough to 50 ohms for present purposes; in fact, they need only be 1% tolerance) as the upper legs of two voltage dividers, and using the device under test (DUT) as one lower leg, and an external 50 ohm load as the other lower leg. (The external load is used to preserve symmetry, which is useful at higher

frequencies. Below a few hundred MHz, an on-board 49.9 ohm resistor can be used.) The reflection from the DUT is equal to the difference between the voltage on the DUT and on the 50-ohm reference. That difference is extracted by means of two successive baluns that function as common mode chokes to pass only the differential signal. The trick to obtaining decent performance is to have an effective balun. The TC1-1-13M balun by itself can only obtain directivity on the order of 20 db (more on directivity below), and also has weak performance below 5 MHz. Therefore, a second balun is used to further choke the common mode signal. Operation To use the bridge as a free-standing device to measure return loss, an input signal is connected to the input and the output is connected to a spectrum analyzer. An open standard is connected to the DUT port, and the output level is recorded. A short standard is then connected to the DUT port, and the output level recorded. The average of the open and short output levels becomes the reference level for that frequency. Various DUTs can then be attached to the DUT port, and the output level recorded. The difference between the DUT output and the reference level (obtained from averaging the open and short), expressed as a positive number in db, is the return loss of the DUT. That return loss measures the reflection received from the DUT relative to the signal sent to the DUT. For example, if the average of the open and short is -12 dbm, and the output with the DUT attached is -30 dbm, then the measured return loss is 30-12=18 dbm. (Error will be discussed later.) The bridge may be used with a vector network analyzer, in which case the use of Open-Short- Load (OSL) calibration will greatly improve accuracy. In addition, the VNA will be able to measure the phase of the reflection, which enables it to determine S-Parameters. Performance The quality of a reflection bridge is measured primarily by its directivity. Directivity is the amount of indicated return loss with a 50-ohm load. There should be no reflection in that situation, so the return loss should be infinite. For use with a VNA directivities of 20 db or better are acceptable, and anything over 30 is nearly perfect. For free-standing use without calibration, a directivity of 30 db will allow measurement of actual return losses up to 30 db, with some uncertainty (more on that later). Another measure of quality is the difference between the open and short output levels. Ideally, the magnitude of the reflection with an open and shorted DUT should be equal. A discrepancy between them may indicate that the DUT port does not present a good 50-ohm impedance to the DUT. When directivity is good and the open and short are close to one another, the DUT port impedance is likely very close to 50 ohms. Figure 2 shows the measured directivity and open/short for the bridge. Note that while we subtract the short output from the open output to determine open/short, we are subtracting db levels so the resulting difference actually represents the ratio of the open and short outputs. Hence the label open/short. For use with OSL calibration, open/short magnitudes as high as 3 are still workable. For use with manual measurements, open/short magnitudes under 1 essentially create a measurement error of only half that magnitude. Thus, in the wide area where open/short is under 0.5 db, the manual measurement error would be only 0.25 db. 2

Figure 2 Directivity and open/short Figure 2 shows that the directivity is good from about 50 KHz to 1.8 GHz, and is excellent from 1 MHz to 1 GHz. The open/short value exceeds 0.5 db at only a couple of small peaks for frequencies below 1.5 GHz. The DUT port should ideally present a 50-ohm impedance to the DUT. If any part of the reflection reaching the DUT port is itself reflected back to the DUT, the measurement of the reflection will be inaccurate. When the bridge is used with a VNA, calibration will correct for this error, unless it becomes unreasonably large. For free-standing use of the bridge, DUT port return losses of 30 db or better are acceptable. The open/short value can be used as a guide to whether return loss is getting out of hand, though the correlation is not perfect. Open/short magnitudes under 0.8 should present no problem. Measuring Return Loss Manually A reflection bridge can be used to measure return loss manually, as described above under Operation. The question arises as to how accurate such measurements are, given the lack of OSL calibration, which a VNA would perform. First, consider how much accuracy is needed. Return loss indicates the amount of power reflected by the DUT. Generally, if the DUT has return loss of 30 db or better (higher), it is reflecting so little power that it does not really matter exactly how little it is. Or in terms of impedance, return loss of 30 db or better means the impedance of the DUT is close enough to 50 ohms that it can be considered to be 50 ohms. For example, resistances between 47 and 53 ohms have return losses of 30 db or higher. On the other hand, if a DUT reflects half or more of the power reaching it, we may just consider it to be unacceptable, without having to know exactly how much it reflects. A DUT with a return loss of 3 db or worse (lower) reflects at least half the power reaching it. So if we know the return loss is higher than 30 db or lower than 3 db, that may be all we need to know. And even for values in the 3-30 db range, errors of several db may not be meaningful. 3

The one situation where precision might be useful is to determine the exact impedance of the DUT, for example in order to devise an impedance matching network to adjust it to 50 ohms. However, because return loss is a scalar value, we cannot determine the exact impedance even if we knew the exact return loss. Phase information would be required. Our manual use of the bridge provides only scalar information, and is effectively a scalar network analyzer, as opposed to the fancier vector network analyzers, which provide phase information. The absence of phase information in return loss generally makes it pointless to try to determine return loss precisely. With that background, what error can we actually expect? Consider the frequency range 250 KHz to 800 MHz. First, the open/short discrepancy creates some error. Ideally, we would use the bridge output with an open DUT as the reference to calculate return losses for large resistances, and the output with a shorted DUT to calculate return losses for small resistances. But we don t know what resistance we are measuring, so we use the average of the open and short values. That creates a possible error equal to half the open/short difference. In our case, this difference reaches a maximum of 0.8 db, so the error is 0.4 db. It is conceivable that the calculation for reactive devices might involve larger error; we don t have phase information so we can t be precise about that. But our open/short and directivity levels are so well behaved that I would not expect there to be additional error for reactive devices. But let s say the total error from the open/ short discrepancy may equal 0.5 db. Let s increase that to 1 db to allow for error in the measurement of the bridge output. Second, directivity essentially indicates a bogus reflection that is present even when there is no real reflection from the DUT. If the DUT actually produces a reflection, the bogus reflection may add to or subtract from that reflection, depending on phasing. So the bogus reflection may cause us to measure too much or too little reflection. If we assume directivity of 30 db (pretty close for 250 KHz-800 MHz), we can actually calculate the extent of maximum error in our measurement. I won t describe the process here, but Figure 3 illustrates the relationship between our return loss reading and the possible range of values of the actual return loss. 4

Figure 3 Possible actual return loss values for a given return loss reading. For example, a reading of 20 db indicates the true return loss lies above 17 db and below 23 db. Figure 3 shows that we can determine return losses with reasonable accuracy if they are below 20 db. Once the return loss reading rises to 30 db and higher, we can say with confidence that the return loss is at least some minimum value (24 db for a reading of 30 db), but there is no limit to what the maximum might be. That may seem like unacceptable error, but remember that for large return losses we frequently only need to know that the return loss exceeds some threshold, without caring how far it exceeds the threshold. If we get a very large reading, like 60 db, we can be sure the true return loss is at least 30 db but can t pin it down any more precisely; but that may be all the information we need. Remember our 1 db uncertainty resulting from the open/loss discrepancy, combined with error in measurement of the bridge output. For readings above 20 db, that error is dwarfed by the uncertainty created by directivity. For readings near zero, it becomes significant. For very low readings, indicating highly reflective DUTs, there are additional possibilities for error. It is probably good practice to proceed as follows: 1. For readings below 5 db, assume a 1 db error. 5

2. For readings of 5 db to 25 db, use the graph in Figure 3 to estimate the possible error, and add 1 db. 3. For readings above 25 db, use the graph in Figure 3 to estimate the minimum possible return loss, and assume there is no ceiling to how high the true return loss may be. 6

APPENDIX Schematic Note: Brass strip is not needed once mounted in a metal enclosure 7