TxBlock-USB Transmitter

Similar documents
P5201 Universal Programmable Transmitters with Galvanic Isolation

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Multifunction Intelligent 4-wire Isolated Signal Conditioner

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

High-precision process calibrator Model CED7000

Universal Intelligent 2-wire DIN Rail Transmitters

Temperature Transmitters - Head Mounted

HART Compatible Intelligent 2-wire DIN Rail Transmitters

Uni-Mux XQL Multi-Channel Data Acquisition Module

Universal Intelligent 2-wire DIN Rail Transmitters

Temperature Transmitters - DIN Rail Mounted

OPTITEMP TT 20 Technical Datasheet

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

CALYS 50. Field multifunction calibrator for basic use

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

FC Series Signal Conditioners

CALYS 75. Field documenting multifunction calibrator

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

MODEL: R30US4. Remote I/O R30 Series

Assembly. Front view. Parametrization interface. Power Bus

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES

High Performance Process & Temperature Controllers

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Technical Information itemp TMT180

CALYS 100. Field precision documenting multifunction calibrator

MODEL: W2TS. Mini-MW Series

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

TS05 Input Functional description Output Deviation 0.15 % Electrical isolation Programming of the measuring range via push-button

SHIMADEN DIGITAL INDICATORS

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Universal Intelligent 2-wire In-head Transmitters

S200 I/O System Units

CALYS 150. Advanced documenting multifunction calibrator thermometer

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

CONTA-ELECTRONICS. Converter Units

Excellent low-cost Process & Temperature Controllers

HART Compatible Intelligent 2-wire In-head Transmitters

Temperature transmitter itemp PCP DIN rail TMT 121

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

The Rosemount 848T Wireless Temperature Transmitter

CALYS 150. Advanced documenting multifunction calibrator thermometer

0 2 1 â Ó. itemp HART TMT182. Technical Information

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

SHIMADEN DIGITAL INDICATORS

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Temperature measurement TMD 832 head transmitter

0 2 1 â Ó. itemp HART TMT182. Technical Information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Two-Wire Programmable Transmitter for:

WIRELESS MODBUS GATEWAY WGW410

Industrial Interface The Signal Conditioning People

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

20 General technical data XI/ON

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

FC-33, DC SELECTABLE SIGNAL CONDITIONER

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

RTD/RES. Pot. Output type Min Max Min. span. Current 4 ma 20 ma 4 ma. Burn-out values Max. output value 21.8 ma Min. output value 2.

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

P1-04THM Analog Input

ONE CALIBRATOR ONLY MAIN FEATURES:

Portable Multi-Channel Recorder Model DAS240-BAT

General Specifications

MINI MCR-SL-UI-I-LP-NC

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

Resistance thermometer Model TR31, miniature design

ph or ORP Transmitter

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

itemp HART DIN rail TMT112

Temperature head transmitter itemp PCP TMT 181

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

INSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1

OPTITEMP TT 10 C/R Technical Datasheet

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

SDM3045X Digital Multimeter. DataSheet

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

General Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

for installation into terminal head form B and for installation on DIN rail Output signals : 4 to 20 ma : 4 to 20 ma 0 to 10 V

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Transcription:

Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is linearized and adjusted in fuction of the input sensor type and range configured. Its configuration is accomplished by connecting the transmitter to a PC USB port without the need of any dedicated interface. The configuration does not require that the transmitter be powered. PT100 2-WIRE Note: When the Pt100 2-wire is selected, the terminals 3 and 4 must be interconnected, according to the figure below. The Pt100 wire length should be less than 30 cm to maintain the measurement error within specifications (electrical resistance). MECHANICAL INSTALLATION The TxBlock-USB transmitter is suitable to be installed in heads. Vibrations, moisture and extreme temperatures, electro-magnetic interference, high voltage and other interferences can permanently damage the unit, and could cause error in the measured value. DIMENSIONS: Fig. 2 Transmitter electrical connections (Pt100 2-wire) PT100 3-WIRE Fig. 1 Transmitter dimensions ELECTRICAL INSTALLATION Section of the cable used: 0.14 to 1.5 mm ². Recommended torque in the terminal: 0.8 Nm. RECOMMENDATIONS FOR INSTALLATION Sensor signals conductors must go through the plant system separate from power leads (loop), if possible in grounded conduits. The instruments must be powered from the instrumentation power supply circuit. In control and monitoring applications is essential to consider what can happen when any part of the system fails. It is recommended the use of suppressors in contact coils, solenoids and any inductive load. PT100 4-WIRE Fig. 3 Transmitter electrical connections (Pt100 3-wire) ELECTRICAL CONNECTIONS The figures below show the electrical connections required. The terminals 3, 4, 5 and 6 are dedicated to the sensor connection. LOAD represents the 4-20 ma current measuring device (indicator, controller, recorder, etc.). Fig. 4 Transmitter electrical connections (Pt100 4-wire) NOVUS AUTOMATION 1/5

Pt1000 3-wire / Pt100 3-wire and 4-wire: For appropriate cable resistance compensation they should be equal for all legs. Maximum wire resistance is 25 Ω per wire leg. Usage of a 3 or 4 wire with conductors of equal length and gauge is recommended. NTC 2-WIRE CONFIGURATION When the trasmitter is used with the factory setting, no further action is required and the transmitter is ready to be installed. Changes to the configuration are possible through the TxConfig II software or the TxConfig application, provided free of charge. The TxBlock-USB Setup Kit consisting of the TxConfig II software and USB cable can be purchased from the manufacturer or any authorized distributor. The software is continuously updated and new versions can be downloaded at no charge from the manufacturer s website. To install, execute the TxConfigIISetup.exe file and follow the instructions. The setup application is only available for Android smartphones and also can be downloaded for free in the Google Play Store. To configure the device through the application, an On The Go (OTG) adapter is required. The procedure for using this adapter will be explained throughout this manual. Fig. 5 Transmitter electrical connections (NTC 2-wire) THERMOCOUPLES Fig. 8 USB cable connection During the setup, the transmitter is powered by the USB, not requiring an external power supply. The transmitter setup can also be made by connecting it to the loop, using the loop power supply. There is no electrical insulation between the transmitter and the communication port (interface), therefore it is not recommended to configure it with the sensor inlet connected to the process. See Fig. 9. Fig. 6 Transmitter electrical connections (Thermocouple) VOLTAGE (0-50 mv) Fig. 9 USB cable connections Loop powered After these connections, the user must run the TxConfig II software and, if necessary, consult the Help topic to help using the software. For more information on how to connect the TxBlock-USB to the smartphone itself and to configure the device, see chapter SMARTPHONE CONNECTIONS. The USB communication port (interface) of the TxBlock-USB is not electrically insulated from the transmitter s input. Fig. 7 Transmitter electrical connections (0-50 mv) NOVUS AUTOMATION 2/5

SOFTWARE AND APPLICATION CONFIGURATION: Fig. 10 TxConfig II software main screen Sensor Range The values chosen cannot exceed the range of sensor shown in this field. See Table 1 of this manual. Minimum Range Do not set a lower band (span) that the Minimum Range indicated below in this same field. See Table 1 of this manual. 4. Sensor Failure: It establishes the output behavior, when the transmitter indicates a failure: Minimum: Output current goes to < 3.6 ma (down-scale), typically used for refrigeration. Maximum: Output current goes to > 22.0 ma (up-scale), typically used for heating. 5. Zero Correction: It corrects small deviations presented in the transmitter output, for example, when the sensor is replaced. 6. Send Configuration: It applies the new setup. Once sent, the setup will be immediately adopted by the transmitter. 7. Read Configuration: Reads the current setup in the transmitter connected. The screen now presents the current setup that may be changed by the user. FACTORY SETTING: Sensor: Pt100 3-wire, range 0 to 100 C Sensor failure: upscale (maximum). 0 C zero correction. Unit: C; Output: 4-20 ma. Upon purchase order, the user can define a specific setup. SMARTPHONE CONNECTIONS With the help of a specific cable, which allows smartphones to recognize and configure TxBlock-USB when running the TxConfig application, Android smartphones with On the Go (OTG) technology can be directly connected to the device via the Micro-USB. To do this, it is necessary to observe the connection mode of the cable On the Go in the device, as can be seen in Fig. 12: The fields in the screen mean: Fig. 11 TxConfig application main screen 1. General Information: This field shows information that identifying the transmitter. This information should be sent to the manufacturer in an eventual request for technical assistance. 2. Sensor: Select the type of sensor to be used. See Table 1. 3. Measuring Range: Sets de measurement range of the transmitter. Lower Range Limit: equivalent temperature for a current of 4 ma. Upper Range Limit: equivalent temperature for a current of 20 ma. Fig. 12 On the Go connection cable Incorrectly positioning the cable end may cause the device to be unrecognized by the application. NOVUS AUTOMATION 3/5

CONFIGURING TXBLOCK-USB WITH TXCONFIG APPLICATION FOR ANDROID: Once the connection between the smartphone and the TxBlock- USB is made, the device will send the following message: Fig. 13 USB device connected For the correct operation of the application, the option "Open TxConfig when this USB device is connected?" must be checked and then click the OK button. After that, it will automatically run the TxConfig application, which has already been previously installed on the smartphone, and will display the following message: Fig. 14 Reading device The application will automatically switch to the configuration screen (see Fig. 11), where it will be possible to configure the TxBlock-USB. OPERATION The sensor offset can be changed through the TxConfig II software or the TxConfig app. The USB cable may be connected to the transmitter without causing any measurement errors. See item Zero Correction in the chapter CONFIGURATION of this manual. The uer must choose the most suitable sensor and range to the process. The chosen range must not exceed the maximum range of measurement defined for the sensor and should not be smaller than the minimum range for the same sensor. It is important to note that the transmitter accuracy is based on the maximum range of the sensor used, even when a narrower range is programmed. Example: The Pt100 sensor in the range 0 to 100 C and accuracy of 0.12 %, the maximum error will be 1.02 C (0.12 % de 850 C). The Pt100 sensor in the range 500 to 600 C and accuracy of 0.19 %, the maximum error will be 1.61 C (0.19 % of the 850 C). Note: When measurements are made at the transmitter, see if the Pt100 excitation current required by the calibrator is compatible with the Pt100 excitation current used in the transmitter: 0.8 ma. SPECIFICATIONS Sensor input: User defined. The supported sensors are listed in Table 1, along with their maximum ranges. Thermocouples: Types J, K, R, S, T, N, E and B accoding to IEC 60584 (ITS-90). Impedance >> 1 MΩ Pt100: Type 3-wire, Excitation 0.8 ma, α= 0.00385, according IEC 60751 (ITS-90). For 2-wire sensors, tie terminals 3 and 4 together. Pt1000: Type 3-wire, Excitation 0.65 ma, α= 0.00385, according IEC 60751 (ITS-90). For 2-wire sensors, tie terminals 3 and 4 together. NTC R25 C: 10 kω ±1 %, B25/85 = 3435 Voltage: 0 to 50 mvdc. Impedance >> 1 MΩ Sensor Type Maximum Measurement Range Minimum Measurement Range Voltage 0 to 50 mv 5 mv Thermocouple K -150 to 1370 C 100 C Thermocouple J -100 to 760 C 100 C Thermocouple R -50 to 1760 C 400 C Thermocouple S -50 to 1760 C 400 C Thermocouple T -160 to 400 C 100 C Thermocouple N -270 to 1300 C 100 C Thermocouple E -90 to 720 C 100 C Thermocouple B 500 to 1820 C 400 C Pt100-200 to 650 C 40 C Pt1000-200 to 650 C 40 C NTC -30 to 120 C 40 C Table 1 Sensors accepted by the transmitter Switch-on delay: < 2.5 s. The accuracy is only guaranteed after 15 min. Terms of reference: Ambient: 25 C; voltage: 24 Vdc, load: 250 Ω; settling time: 10 minutes. Temperature Effect: < ±0.16 % / 25 C Response time: Typical 1.6 s. Maximum voltage allowed at input terminals no sensor: 3 V. RTD current: 800 µa. RTD cable resistance effect: 0.005 C / Ω Maximum allowable cable resistance for RTD: 25 Ω. Sensor Type Typical Accuracy Minimun Accuracy Pt100 / Pt1000 (-150 to 400 C) 0.10 % 0.12 % Pt100 / Pt1000 (-200 to 650 C) 0.13 % 0.19 % mv, K, J, T, E, N, R, S, B 0.1 % (*) 0.15 % (*) NTC 0.3 C 0.7 C Table 2 Calibration error, percentage of the full measurement range (*) Add cold junction compensation: < ± 1 C. Power supply influence: 0.006 % / V typical (percentage of the full measure range). Output: 4-20 ma or 20-4 ma current, 2-wired; linear in relation to the temperature measurement by the selected sensor. Output Resolution: 2 µa. Power supply: 10 to 35 Vdc, across the transmitter; Maximum load (RL): RL (max.) = (Vdc 10) / 0.02 [Ω] Where: Vdc= Power supply voltage (10-35 Vdc) Operating Temperature: -40 to 85 C Humidity: 0 to 90 % RH Electromagnetic Compatibility: EN 61326-1:2006 NOVUS AUTOMATION 4/5

No electrical isolation between input and output. Internal protection against polarity inversion. Cold junction compensation for thermocouples. Dimensions: 43.5 mm (diameter) x 20.5 mm (height) Connection Wire Cross Section: 0.14 a 1.5 mm² Screw Tightening: 0.8 Nm Housing: ABS UL94-HB SAFETY INFORMATION Any control system design should take into account that any part of the system has the potential to fail. This device is not a protection or safety device and its alarms are not intended to protect against device failures. Independent safety devices should be always provided if personnel or property are at risk. Device performance and specifications may be affected by its environment and installation. It s user s responsibility to assure proper grounding, shielding, cable routing and electrical noise filtering, in accordance with local regulations, EMC standards and good installation practices. SUPPORT AND MAINTENANCE This device contains no serviceable parts inside. Contact our local distributor in case you need authorized service. WARRANTY Warranty conditions are available on our website www.novusautomation.com/warranty. NOVUS AUTOMATION 5/5