Development, Trials and Testing of a Two Componet Rapid Set Cement Grouting System

Similar documents
A New Technique to Determine the Load Transfer Capacity of Resin Anchored Bolts

Sample Size and Sample Strength Effects on Testing the Performance of Cable Bolts

Double Shear Testing of Bolts

Strength Properties of Fibre Glass Dowels Used for Strata Reinforcement in Coal Mines

Grouting. Recommendations for cementitious grout for NC-Bolt and Pc-Bolt. Rev. 04/18

Evaluating methods of underground short encapsulation pull testing in Australian coal mines

FiReP GRP Bolts. Bolting systems for mining and tunnelling. Solutions from Materials Technology

HIGHER PERFORMANCE IN ROCK-BOLTING TECHNOLOGY BY USE OF IMMEDIATE-BEARING GROUTED BOLTS

Factors Affecting Pre-Tension and Load Carrying Capacity in Rockbolts - A Review of Fastener Design

Hilti HIT-HY 200 with HIT-Z

Module 10 : Improvement of rock mass responses. Content

DEVELOPMENT OF NEW TESTING PROCEDURE FOR THE ENCAPSULATED ROOF BOLT INSTALLATION IN COAL MINES ASSESSMENT OF RESIN PERFORMANCE FOR IMPROVED

2015 BBUGS Suppliers Day Jennmar Queensland Presentation A Review of Cable Support Systems from Jennmar

Modelling of Rebar and Cable Bolt Behaviour in Tension/Shear

The Evolution of Pre-driven Recovery Roadways at Crinum Mine

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

Rock and bolt properties and load transfer mechanism in ground reinforcement

HILMA Quick Tool Change for Forging Applications

Roof Bolting Guidelines in. South African Collieries

SEA SELF DRILLING, THREADED, HOLLOW BAR / GROUT-ABLE SOIL NAILS / ANCHORS

Injection moulding BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF POLYMER ENGINEERING

A new approach in determining the load transfer mechanism in fully grouted bolts

Umbrella Inserts and Stubby Screens

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

INVESTIGATION INTO THE EXTENT AND MECHANISMS OF GLOVING AND UN-MIXED RESIN IN FULLY ENCAPSULATED ROOF BOLTS

HACETTEPE UNIVERSITY MINING ENGINEERIN DEPARTMENT

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

SOFRASAR TUNNEL PRODUCTS CONNECTING ALL COMPONENTS

Moment Resisting Connections for Load Bearing Walls

A. Extent of structural precast concrete work is shown on drawings and in schedules.

UNIVERSITY OF THESSALY

PWM. Design, Installation, and Operation. (Pulse Width Modulation Zone Controller)

DESIGN OF MACHINE MEMBERS-I

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

MEASURING, UNDERSTANDING, AND IMPROVING THE PERFORMANCE OF FULLY GROUTED RESIN BOLTS IN UNDERGROUND COAL MINES

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Hours / 100 Marks Seat No.

Appendix B Drilling Methods

Index Terms: Lathe waste concrete; Shear and bending; Shear strength; Stirrups; Simply supported beams.

A new sistem for harbour restoring: The Under Water Anchoring tecnology.

REMA FLAT BLADE CONTACT CONNECTORS SR50 SR175 SR350

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

NZQA registered unit standard version 3 Page 1 of 6

Self-compacting premix

Special Provision No. 904S14 October OPSS 904, January 1995, Construction Specification for Concrete Structures, is amended as follows:

Construction. Sika Grouting Systems. Properties of Grout. Grouting Considerations

Vacuum Casting in the Loughborough Design School

Product features and advantages

FOAMED BITUMEN STABILISATION PROJECT WARWICK, QLD

Experimental Study on Pile Groups Settlement and Efficiency in Cohesionless Soil

Innovative laboratory equipment. Preliminary testing to determine the mix quality.

Early Days of Rock Mechanics and Strata Control

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes

4.0 MECHANICAL TESTS. 4.2 Structural tests of cedar shingles

SEISMIC BEHAVIOR OF BEAM-TO-COLUMN DOWEL CONNECTIONS: NUMERICAL ANALYSIS VS EXPERIMENTAL TEST

Zero Point Clamping System. ZERO lock BALL lock

Problem-free economical and safe use of bulk materials

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

Bolt Tensioner. Axial Bolt Tensioning using High-Pressure Hydraulic. SSV and HM Axial bolt tensioning without torquing!

GRIP & GRAB ADHESIVE

Prying of a Large Span Base Plate Undergoing a Moment Load Applied by a Round Pier

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

PURE 150-PRO EPOXY ADHESIVE ANCHOR

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Glued laminated timber beams repair.

Umbrella Inserts and Stubby Screens

RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA, SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA, 2016 Volume 24, Number 39

Steel Plate in Oil Rig Blowout Preventer Valves

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

CHAPTER 5: MOULDING PROCESS

ANALYSIS OF PILE-RAFT FOUNDATIONS NON- RESTED AND DIRECTLY RESTED ON SOIL

CONCEPTUAL DESIGN OF A FRETTING FATIGUE TESTING DEVICE

ANCHORING TECHNOLOGY - GROUT VS INJECTION

Repair Manual MWS45A-MWS50A-MWS55A MW32A-MWS36A-MWS40A. Ref Rev.D General Pump is a member of the Interpump Group

2001 HSC Engineering Studies Marking Guidelines

PRODUCTION TOOLING FOR POLYMER COMPONENTS VIA THE DTM RAPIDSTEEL PROCESS

PLEASE SPEND 5 MINUTES READING THESE INSTRUCTIONS BEFORE USING YOUR NEW RIVET TOOL. TRUST US, IT WILL SAVE YOU TIME AND INCONVENIENCE IN THE LONG RUN.

Assembly instructions

Wear Analysis and Optimization on Impregnated Diamond Bits in Vibration Assisted Rotary

PRESSURE DISTRIBUTION AND SURFACE QUALITY DURING FORMING OF THERMOPLASTIC COMPOSITES WITH A COLLECTION OF RUBBER PARTICLES AS MOULD HALF

DOT N LINE EQUIPMENT

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

State-of-the-art Report On FULL-DEPTH PRECAST CONCRETE BRIDGE DECK PANELS (SOA )

Forming and assembling pipework systems

Slip and yield resistance of friction type of high strength bolted connections with over-sized holes

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Early warning of longwall roof cavities using LVA software

LAPPING FOR MIRROR-LIKE FINISH ON CYLINDRICAL INNER AND END SURFACES USING THE LATHE WITH LINEAR MOTOR

Not including the type of fabric used (clear pvc or shade mesh), there are three main types of side screen.

Forming and Assembling Pipework Systems F/508/4663

SEMPEO SQA Unit Code FP2C 04 Installing aircraft mechanical fasteners

Self contained servo drive CLDP Technical data sheet

+ + CFA Guidance Note: Powder Actuated Fixing Systems. Ensuring best fixings practice. Contents. 1.

NOVEL CONCEPT OF THREE-DIMENSIONAL (3D) THICK COMPOSITE STRUCTURE FROM PITCH BASED CARBON FIBRE FOR MACHINE TOOL APPLICATIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Connection and performance of two-way CLT plates

ENGINEERED RUBBER COMPONENT MANUFACTURING

Transcription:

University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2018 Development, Trials and Testing of a Two Componet Rapid Set Cement Grouting System Tom Meikle Minova Australia Robert Hawker Minova Australia Colin Grubb Minova Australia Stephen Tadolini Minova Australia Peter Mills Minova Australia Publication Details Tom Meikle, Robert Hawker, Colin Grubb, Stephen Tadolini and Peter Mills, Development, Trials and Testing of a Two Componet Rapid Set Cement Grouting System, Proceedings of the 18th Coal Operators' Conference, Mining Engineering, University of Wollongong, 353-362. Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: research-pubs@uow.edu.au

DEVELOPMENT, TRIALS AND TESTING OF A TWO COMPONENT RAPID SET CEMENT GROUTING SYSTEM Tom Meikle 1, Robert Hawker 2, Colin Grubb, Stephen Tadolini, Peter Mills ABSTRACT: In unfavorable strata conditions, it is often necessary to install additional long tendon support as part of a primary support cycle. Although these support systems provide the required additional stability to the roadway, installation does have a significant effect on the rates of development. To overcome the slow cure time of Portland cement type grouts, the use of two component resin systems such as Polyurethanes and Urea Silicates have become favored but concerns over creep properties has led to the development of a new two component grouting medium which displays the properties of traditional cable grouting materials with the rapid reaction times of pumpable resin systems. This paper describes product testing, product application - surface trials, underground trials and full-scale applications of the Tekthix system in a dynamic underground environment. INTRODUCTION Single component cement grouts have been used to anchor long tendon supports for many years. They range from basic high and low slump Portland cement-based slow setting grouts to fast setting single component grouts. However, current cement grouting systems (grout and equipment) have some disadvantages: 1. Low slump grouts require pumps that can pump a thick high viscosity grout, so choice of pump is limited. 2. Pumping distance is limited with current cable bolt grout pumps; operators often tend to add additional water to allow pumping long distance, which adversely impacts the quality and strength of the material. 3. Fast setting grouts tend to cause issues with pump and line blockages due to reduced working life of these single component materials. The industry required a fast setting grout that could be pumped further than current single component grouts, whilst still having high values for UCS, Young s Modulus, Flexural and Adhesive strengths. Any change to current ground control systems, requires intensive testing to take place to ensure that the support system used has not been compromised by any change Tekthix has been developed to meet these requirements. TEKTHIX TWO-COMPONENT CEMENT GROUT Tekthix can best be described in the following terms: A two component cement grout Used for grouting of any long tendon support system Individual components mixed at water: powder (w:p) of 0.35:1 Mixed Part A with Part B in a volume ratio of 1:1 Capable of being pumped in excess of 200 m to point of application Mixed through static mixer at site of application Reacts quickly to form thick paste for top down grouting within seconds of mixing and sets within minutes to provide early load transfer between steel tendon and strata. 1 Business Development Manager, Minova Australia. Email: tom.meikle@minovaint.co 2 Technology Manager. Email: robert.hawker@minovaint.co University of Wollongong, February 2018 353

LABORATORY TESTING The following laboratory tests were carried out on the product: Uniaxial Compressive Strength Flexural Strength Tensile Strength Young s Modulus Creep Testing Adhesive Strength Viscosity of single components Double Embedment Pull Testing Mechanical properties TESTING REGIME The Tekthix individual components were mixed at the corresponding water to powder ratio of 0.34-0.35: 1 at room temperature. Following this the two mixtures were mixed together at a 1:1 ratio by volume and cast into various cubes and cylinder moulds for testing. The samples were left to cure at room temperature for the corresponding period of time then tested using either 500kN compression machine also a Shimadzu 50 kn compression machine. Uniaxial Compressive Strength (UCS) The UCS of Tekthix ranged between 25 MPa at one hour and 75 MPa at 28 days. By comparison, currently used Portland based cement grouts have UCS values in the range of 30 MPa at 24 hours and 70 MPa after 28 days Figure 1 and Figure 2. Figure 1 shows Tekthix UCS at 0.34:1 and 0.35:1 Water/ Solids ratio. Figure 2 shows the comparison of UCS with two other single component grouts from 1 hour to 28 days. Uniaxial Compressive Strength (MPa) 80 70 60 50 40 30 20 10 0 Tekthix UCS 0 5 10 15 20 25 30 Cure time (days) 0.34:1 water/powder ratio 0.35:1 water/powder ratio Figure 1: Tekthix UCS at 0.34:1 and 0.35:1 water /solids ratio University of Wollongong, February 2018 354

Figure 2: Comparison of UCS values of Tekthix with two other single component grouts from 1 hour to 28 days Flexural Strength Figure 3 shows Flexural strength growth at 1hr, 24hrs and 7 days, Figure 4 shows sample being tested in the Shimadzu 50 kn compression machine. The Flexural Strength of Tekthix ranged between 2 MPa at 1 hour and 8 MPa at 7 days. Figure 3: Flexural strength growth at 1hour, 24 hours and 7 days Figure 4: Shimadzu Test Unit Tensile Strength The Tensile Strength of Tekthix ranged between 3.5 MPa at 1 hour and 5.5 MPa at 7 days. Figure 5 shows results for, 1 hour, 1 day and 7 days. Figures 6 and 7 show the testing process using the Shimadzu 50kN compression machine. Figure 5: Tensile strength of Tekthix for 1 hour, 1 days and 7 days University of Wollongong, February 2018 355

Figure 6: Axial tensile testing of sample Figure 7: Post-test split sample Young s Modulus Figure 8 shows Young s Modulus after 1hr, 24hrs and 7 days. Young s Modulus values ranged from 3000 MPa after 1 hour to 4600 MPa after 7 days, by comparison, two component Urea Silicate grouts or Polyurethanes have Young s Modulus values below 1000 MPa. Figure 8: Young s Modulus of Elasticity of Tekthix grout at various curing times/ages Creep (BS7861) Samples of dimension 12.5 mm x 12.5 mm x 50 mm where subjected to constant load of 5 kn and the change in strain was measured between 30 seconds and 15 minutes. BS7861 calls for strain % of less than 0.12% to comply. Figure 9 shows percentage creep. University of Wollongong, February 2018 356

Figure 9: Rheological /Creep characteristic of Tekthix grout Adhesive Strength To evaluate bond strength of Tekthix in comparison to Geoflex Urea Silicate Resin, two sandstone blocks of dimensions 50 mm x 50 mm x 100 mm were bonded together with a bond width of 3 mm to 5 mm and left to cure for two hours. Figure 1 shows the average grout UCS after one hour of casting. The bonded blocks were then subjected to a flexural strength test and bond strength calculated. Table 1: Average Stress N/mm 2 Time after casting Tekthix Urea Silicate 1 hour 3.17 N/mm 2 1.64 N/mm 2 Component Viscosity As the viscosity of both components increases with time, it was important to understand individual pot life of both components. It was evident that if either component was left standing after initial mixing, that the viscosity would slowly increase to such an extent that it would have an effect on the pumpability of that component which could lead to pumping difficulties. The low viscosity of the individual Tekthix components enable pumping distances in excess of 200 m, by comparison to standard Portland cement grouts have a limitation of approximately 30 m with current pumps. Figure 10 shows rate of increase in Viscosity at 25 o C with product standing and mixing. Double Embedment Pull Testing (DEPT) This test was carried out using an Instron Hydraulic Universal Testing Machine. The objective of this test was to compare the load transfer performance of Tekthix and a common Industry used single component Portland cement grout, Stratabinder HS (SBHS) Tekthix testing was carried out after 4-5 hours, single component grout after 24 hours. Grout details The Tekthix grout used in the 320 mm steel tube sections was tested at 4 hours and gave a UCS of 35MPa. The Stratabinder HS grout used in the comparison 320 mm tube sections was mixed at 0.4:1 water to powder ratio, which when tested at 24 hrs gave a UCS of 20MPa. Laboratory testing overview The main aim of the laboratory testing was to determine the mechanical properties of Tekthix compared to current Portland cement single component grouts. In all aspects, Tekthix proved to have higher UCS, Adhesive Strength. Comparison of results achieved using the Double Embedment Pull Test (DEPT) test method has shown that Tekthix grout at 4-5 hours cure University of Wollongong, February 2018 357

time) achieved double the peak loads over Stratabinder HS at 24 hours cure time when either the Secura HGC or Megabolt MW9 cable are used. Figure 10: Tekthix A and B Viscosity changes at 25 o C, with respect to product standing and mixing The results also showed that load stiffness between 50-150 KN is 40% higher on average for Tekthix (37 KN/mm) over Stratabinder HS (26 KN/mm) at the tested cure times. Total work energy to 100 mm displacement is also as expected over 40% higher on average for the six tests for Tekthix (25 kj) over Stratabinder HS (10 kj). These results clearly indicate the higher load support benefits for Tekthix at an early age over Portland cement type grouts such as Stratabinder HS even with 24 hours curing (cure) period. Figure 11 shows Cable set up for DEPT, Figures 12 and 13 show cable after DEPT Testing and Figures 14 and 15 show results of DEPT on both the Secura and MW9 Cables using Tekthix. Figure 11: Pull testing set up University of Wollongong, February 2018 358

Figure 12: Post-test pulled out cable Figure 13: Close-up view of pulled out cable Figure 14: Load- displacement of Secura Cable bolt using different grouts. Figure 15: Load displacement of MW9 cable bolts with different grouts. University of Wollongong, February 2018 359

PRODUCT APPLICATION SURFACE TRIALS The following surface trials were carried out prior to any grouting trials. Product recirculation through pump The A and B components were mixed at 0.35:1 water to solids ratio and re-circulated through the pump for 4 hours to confirm: Pot life of individual components Separation of product Piston seal wear/damage Product build up inside pistons. Re-circulation results Changes in viscosity caused by recirculating through the pump were no different from those found when mixing the product. There was no sign of the solid components separating from the water Delivery rate through the pistons remained unchanged and on target There was no visible sign of seal wear or damage There was no buildup of material in the piston or around the seals. Maximum pumping distance and optimum hose diameter 150 m of DN20 hose was fitted to the outlets of each component cylinder. The pump was set at 60 cycles per minute (60 upward and 60 downward strokes), which delivered product at a rate of 12 liters/min per side (24 liters per minute combined). Pressure gauges set in line showed zero pressure. A further test was carried out with 250 m of DN20 hose, which showed similar results. Pump stall pressure Pressure gauges and shut off valves were set in line to each cylinder. The pump commenced stroking at 60 cycles per minute and each valve slowly closed. When fully closed, output pressure. Figure was 120 bar. Mixing nozzle configuration The aim of these trials was to determine which mixing attachment both mixed the components correctly and achieved minimal backpressure. After several trials, a nozzle that consisted of DN20 fittings (Figure 16) and a 12 module x 16 mm static mixer (Figure 17) provided the best outcomes. Figure 16: Grout mixing attachment DN20 fittings University of Wollongong, February 2018 360 Figure 17: Grout Static Mixer

Grouting trials To simulate a cable inside a borehole, 6 m x 38 mm hollow cables were inserted into 40 mm conduit to confirm that the system could achieve full encapsulation Figure 18. 50 m of DN20 hoses were installed onto the pump. Once the grout was allowed to set, cables were cut into 2m sections to confirm full encapsulation Figure 19. This process was repeated several times with water temperature ranging from 24 o C to 30 o C. Grouting outcomes The system proved to be capable of pumping Tekthix through 50 m of DN20 hose and achieves full encapsulation each time. Figure 18 shows full encapsulation of 6 m cables. Figure 19 shows cable cross section. Figure 18: Full encapsulation of 6m cables Figure 19: Cable cross section UNDERGROUND TRIALS The first underground trial was carried out at a New South Wales Coal Mine. A series of hollow cables were successfully grouted without any issue. Grouting time ranged from 3 4 minutes. Grout was seen issuing from the telltale hole in the plate confirming full encapsulation had been achieved. Pump strokes were counted to confirm the volume of grout pumped into each cable was equal to or greater than the theoretical volume of annulus and grout tube inside the cable. Figure 20 shows grout lance attachment, Figure 21 shows grout tell tale. Figure 20: Grout lance attachment Figure 21: Grout Tell Tale Having reviewed the results of the initial trail, and additional product testing information provided by Minova, the mine decided to fully implement Tekthix in the widening of the next University of Wollongong, February 2018 361

longwall installation road. The first pass of the installation road at 5.5m wide is followed up by a 2 nd pass of 2.5 m wide, to achieve a total width of approximately 7 m. The second pass consists of cutting to full width for approximately 20 linear meters. In order to provide additional stability to the wide span, a series of fully grouted, 6 m and 8 m long tendon cables are installed. Using standard single component grout, the grout is allowed to set for a minimum period of 24 hours before cutting of the 2 nd pass recommences. With the rapid set time of Tekthix, the wait time was reduced to less than 4 hours. A total of 350 cables were installed and grouted with Tekthix reducing the strip out time substantially. CONCLUSIONS The Mechanical properties of Tekthix two-component grout are equivalent to, or greater than current single component grouts. In addition, Tekthix also offers the additional advantage: Rapid strength gain allowing in cycle bolting and substantial reduction in cycle times, Higher Load Transfer performance than single component grouts, System can be adapted to be used with any support system that uses cement grouts, Pumping distance way in excess of current single component cement grouts. To date, over 1000 cables have been grouted using Tekthix, and at date of publishing, three more large campaigns are planned in both New South Wales and in Queensland coalmines. Further development in the pumping and mixing system is ongoing in order to reduce mixing time of grout and also to explore pumping this type of grout from a surface installation to underground location. ACKNOWLEDGEMENTS The authors would like to acknowledge the effort of the Minova Australia/Asia support teams in the development of this innovative solution. University of Wollongong, February 2018 362