Arc Flash Analysis Training

Similar documents
SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

SECTION SHORT CIRCUIT, COMPONENT PROTECTION, FLASH HAZARD AND SELECTIVE COORDINATION STUDY

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

ADDENDUM NO. 2 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

Electrical Arc Hazards

SECTION POWER SYSTEMS STUDIES

Education & Training

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

Arc Flash Analysis and Documentation SOP

2017 ELECTRICAL SAFETY SERVICES. Arc Flash Electrical Maintenance Lockout/Tagout And More

First Draft Language

2015 NFPA 70E. SESHA 2015 ARIZONA MINI CONFERENCE December 10, 2015 Intel Corporation

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor.

3Ø Short-Circuit Calculations

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

Short Circuit Current Calculations

Tower Grounding Training For Telecommunications Networks

A Guide to Establish an Arc Flash Safety Program for Electric Utilities

Electrical PIP ELEGL03 Guidelines for Power Systems Analysis

MV Power Cable Testing Training

NFPA-70E. Electrical Safety in the Workplace. Standard for Edition

Arc Flash Mitigation An Overview. Gus Nasrallah, P.E. Electroswitch May 30, 2013

Arc Flash and NFPA 70E

Arc Flash Study Principles & Procedures for below 15 kv AC Systems. Xuan Wu, Dennis Hoffman, Ronald Wellman, and Manish Thakur

TABLE OF CONTENT

2018 Consultant s Handbook Division 26 Electrical ARC Flash Hazard Analysis

Paul Dobrowsky Innovative Technology Services

Cause, Effect & Mitigation Strategies

Electrical Overcurrent Studies

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Steve Kovach District Sales Engineer

STANDARDIZING ARC FLASH PPE LABELS

Arc Flash Calculation Methods

Design Approaches for Hospital Distribution Systems With Considerations for Future Expansion, Operator Safety, and Cost

Electrical Measurement Safety. Sponsored By:

Note: The let-through of the protective device must be equal to or less than the short-circuit current rating of the component being protected.

ELECTRICAL EQUIPMENT. Inspection. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

2014 NEC Changes Part 1

How to maximize reliability using an alternative distribution system for critical loads

Bruce L. Graves /01/$ IEEE. IEEE Industry Applications Magazine PhotoDisc, Inc.

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Webinar: An Effective Arc Flash Safety Program

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

{40C54206-A3BA D8-8D8CF }

Upgrading Your Electrical Distribution System To Resistance Grounding

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

ARC FLASH HAZARD ANALYSIS AND MITIGATION

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

FACILITY RATINGS METHOD TABLE OF CONTENTS

Effective System Grounding

1

Selective Coordination for Emergency and Legally-Required Standby Power Distribution Systems

THREE PHASE PAD MOUNTED DISTRIBUTION TRANSFORMER ARC FLASH TESTING JUNE 23, 2009 FERRAZ SHAWMUT HIGH POWER LABORATORY NEWBURYPORT, MA

SWITCHING SAFETY & RELIABILITY CONFERENCE

Industrial Electrician Level 3

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

SECTION PANELBOARDS

Electrical Safety Policy Health and Safety FCX-HS03 Release 07/2018 Version 1

Electrical Severity Measurement Tool Revision 4

Key factors to maintaining arc flash safety

Field Instruction Switching Activities. Purpose. Scope. Objective. Safety

Electrical Switchgear & Power Transformer Testing. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

2 Grounding of power supply system neutral

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

DESIGN STANDARD DS 29

PRODUCTIVELY SAFER LOCK-OUT TAG-OUT PROCEDURE

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Grounding for Power Quality

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

Electrical testing safety Part 1: Preparing for absence of voltage testing

COMMON SOURCES OF ARC FLASH HAZARD IN INDUSTRIAL POWER SYSTEMS

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

ELECTRIC TRANSMISSION (ET) Guideline G0104

REDUCING ARC FLASH HAZARD BY REMOTE SWITCHING

APPLYING LOW-VOLTAGE CIRCUIT BREAKERS TO LIMIT ARC FLASH ENERGY

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

TN, TT & IT Earthing Arrangements

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Cutler-Hammer January 1999

T e l N o : F a x N o : E m a i l : a i s h c m c - m e. c o m w w w. c m c - m e.

LV/MV/HV CIRCUIT BREAKERS (SWITCH GEAR) DESIGN, INSPECTION, MAINTENANCE, REPAIR & TROUBLESHOOTING

Table of Contents. Introduction... 1

Canadian Technology Accreditation Criteria (CTAC) ELECTRICAL ENGINEERING TECHNOLOGY - TECHNOLOGIST Technology Accreditation Canada (TAC)

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

EDS FAULT LEVELS

Embedded Generation Connection Application Form

CONTENTS. 1. Introduction Generating Stations 9 40

LOCKOUT / TAGOUT PROGRAM

Distribution System Development & Preliminary Studies

The Importance of the Neutral-Grounding Resistor. Presented by: Jeff Glenney, P.Eng. and Don Selkirk, E.I.T.

Power Systems Modelling and Fault Analysis

Utility Interconnection and System Protection

Specialists in HV and MV test and diagnostics. Testing in Substations

Transcription:

Arc Flash Analysis Training Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq An arc flash analysis study is usually performed through the collection of data from existing electrical equipment and systems, followed by the proper calculation of arc flash hazards and requirements by an experienced electrical engineer. This can be done using either the manual method using IEEE 1584 calculations or using popular arc flash study/short circuit study analysis software. An effective arc flash analysis training program should provide electrical engineers with the knowledge and understanding of how to perform such an analysis/study. Performing arc flash hazard analysis study on an electrical distribution system is cruicial to understanding the potential arc flash hazard of electrical equipment. An arc flash analysis study is not a one-time event, but rather it is just a snapshot of the electrical system at one specific point in time. Any changes to the electrical system can potentially affect the accuracy of the arc flash analysis. But once arc flash analysis study in place, it must be maintained if it is to remain effective. Updating the Arc Flash Anaysis Study program maintenance involves two critical elements:

the study itself and electrical worker safety training. Section 130.5 of NFPA 70E Standard for Electrical Safety in the Workplace specifies that arc flash hazard analysis shall be updated whenever there is a major modification or renovation to the electrical system (e.g., changing a feed or adding large motors). Even in the absence of such changes, NFPA 70E still mandates reviewing the arc flash study a maximum of every five years to account for the many little changes that can have a big impact on study results. Retraining in NFPA 70E/CSA Z462 Like as in the case of the arc flash analysis study, proper training of qualified electrical workers in NFPA 70E/CSA Z462 is not a one time event. Workers leave; new ones are added; people simply forget what they have learned. NFPA 70E section 110.2(D)(3) specifies additional as-needed worker training under certain conditions, but it also mandates retraining all qualified workers at an interval not to exceed three years. Some companies have adopted a yearly retraining policy, due to the importance of the NFPA 70E electrical safety concepts. Arc flash analysis training educates electrical professionals about the existence, nature, causes and methods to prevent electrical hazards. Arc flash is a serious hazard with potentially devastating potential injury. Our arc flash analysis training course includes information on arc flash awareness, standards and codes, understanding of arc flash quantities, selection and use of appropriate PPE, reading and following warning signs and labels, methods to reduce risk while working on live exposed parts, arc flash hazard assessment and documentation. This is done to ensure electrical worker safety and meeting the challenges of the arc flash safety requirements can be a difficult task. From arc flash analysis and labeling to personal protective equipment and training. Who Needs Arc Flash Analysis Training? Most commercial, institutional, and industrial electrical systems have arc flash hazards. In the United States, OSHA requires that those systems be individually analyzed and, if hazards

exist, labeled to identify the arc flash boundary, the incident energy at the working distance, and the required personal protective equipment (PPE). Our Arc Flash Analysis Training course teaches arc flash analysis in the following areas: Arc flash hazard analysis Arc flash hazard labeling plan Site review / compliance assessment Mitigation services Single-line diagrams Short circuit and coordination studies Preventative maintenance Electrical safety program review / development Arc Flash Training Personal protective equipment plan Documentation Arc flash hazard analysis Arc Flash Hazard Analysis Canadian Standards Association (CSA) Z462 guidelines require facility owners to perform an arc flash hazard analysis prior to allowing a worker or contractor to perform a task on energized equipment. The arc flash analysis identifies the presence and location of potential hazards and provides recommendations for personal protective equipment (PPE), boundaries for limited, restricted and prohibited approaches, recommendations for flash protection and safe work practices. The Electricity Forum recommends that arc flash calculations be completed in conjunction with short circuit study calculations and protective device coordination to achieve the most accurate arc flash hazard results. Short circuit and coordination studies verify protective devices and arc hazard ratings, calculate momentary interrupting and relay currents,

establish settings for all types of protective devices and coordinate your entire power distribution system to minimize downtime. COURSE OBJECTIVES Learn about arc flash hazards, standards, safety and calculations. This course is designed to educate participants about all aspects of arc flash studies. LEARNING OBJECTIVES Upon completion of this course, the student will learn how to: Develop A Realistic Risk Assessment, Ensuring Proper Personnel Safety And Increased Compliance By Workers Eliminate Hours Of Engineering Time And Prevent Costly Mistakes Assure Electrical System Reliability Provide Documentation And Labeling For Your Arc Flash Hazard Safety Program Avoid Unnecessary Costs From Over Specification Of Gear, Providing Higher Potential Worker Productivity Savings Thousands Of Dollars On An Annual Basis! Understand Short Circuit Study Fundamentals Understand Arc Flash Study Fundamentals Comply With Standards For Limits Of Approach Produce Arc Flash Labeling Perform Arc Flash Approach Boundary Calculations And More!

WHO SHOULD ATTEND This Arc Flash Analysis Training Course is intended for electrical engineers, plant supervisors, electrical maintenance professionals and electricians who are involved with industrial, commercial and institutional electric power distribution systems: Plant, facility, and corporate electrical engineers dealing with one or more company distribution systems, and consulting and utility engineers dealing with clients systems. Consultants, architectengineers will also find this course very beneficial. STUDENTS RECEIVE FREE 100-Page Digital Electrical Safety Handbook (Value $20) $100 Coupon Toward Any Future Electricity Forum Event (Restrictions Apply) 1.4 Continuing Education Unit (CEU) Credits FREE Magazine Subscription (Value $25.00) Course Materials In Paper Format

COURSE OUTLINE COURSE CONTENT POWER SYSTEM FUNDAMENTALS Power System Fundamentals Balanced Three-Phase Loads Unbalanced Three-Phase Loads Power distribution systems Effects of frequency Single-phase power loads Three-phase balanced and unbalanced power loads Short Circuit Theory, Terminology and Studies Fault Current Sources and Characteristics Power System Configurations Typical System configurations Design considerations Radial systems, loop systems, selective systems POWER SYSTEM SUBSTATION CONFIGURATIONS Functions of a substation Design considerations Radial, loop, and selective systems Introduction Why do the calculation? When to do the calculation? ELECTRICAL FAULTS Definitions and Terminology Arcing Faults vs. Bolted Faults

Causes Effect of Current on Overcurrent Device Clearing Time Current Limiting Effects on Personnel and Equipment NFPA 70e/CSA Z462 and ELECTRICAL SAFETY PROGRAMS Safe Approach Distances Qualified vs. Unqualified Workers Work on or Near Energized Electrical Equipment Energized Electrical Work Permit Safe Work Practices and Procedures Calculation Methodology Step 1: Construct the System Model and Collect Equipment Parameters Step 2: Calculate Equipment Short Circuit Impedances Network Feeders Synchronous Generators and Motors Transformers Cables Asynchronous Motors Fault Limiting Reactors Static Converters Other Equipment Step 3: Referring Impedances Step 4: Determine Thévenin Equivalent Circuit at the Fault Location Step 5: Calculate Balanced Three-Phase Short Circuit Currents Initial Short Circuit Current Peak Short Circuit Current Symmetrical Breaking Current DC Short Circuit Component Step 6: Calculate Single-Phase to Earth Short Circuit Currents Worked Examples

Step 1: Construct the System Model and Collect Equipment Parameters Step 2: Calculate Equipment Short Circuit Impedances Step 3: Referring Impedances Step 4: Determine Thévenin Equivalent Circuit at the Fault Location Step 5: Calculate Balanced Three-Phase Short Circuit Currents Initial Short Circuit Current Peak Short Circuit Current Computer Software DAY TWO MODELING AN ELECTRICAL SYSTEM IN PER-UNIT Modeling methods Data collection and modeling Per-unit impedance calculations Complex impedance diagrams SHORT CIRCUIT STUDIES Purposes of fault calculations Effects of short circuits Fault current sources Machine reactance modeling Fault current characteristics Types of faults/magnitudes Fault calculation procedures PROTECTIVE COORDINATION Typical Device Curves and Settings Transformer Protection

Feeder Protection Motor/Generator Protection Type 2 Coordination Fault Let-Through Approved Series Combinations LOW VOLTAGE EQUIPMENT RATINGS AND SELECTION CRITERIA Low voltage fuses Molded case circuit breakers Busway and conductors SWITCHGEAR RATINGS AND SELECTION CRITERIA Low voltage power circuit breakers Power fuses Load interrupters Medium voltage power circuit breakers Equipment Ratings and Asymmetrical Factors Analysis of a Computerized Fault Study COURSE TIMETABLE Both days: Start: 8:00 a.m. Coffee Break: 10:00 a.m. Lunch: 12:00 noon Restart: 1:15 p.m. Finish: 4:30 p.m.

Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq