I N T E R N A T I O N A L R E S I D E N T I A L CO D E

Similar documents
I N T E R N A T I O N A L R E S I D E N T I A L CO D E

IN T E R N A T I O N A L

Visual Interpretation Of The NTERNATIONAL ESIDENTIAL *** WITH NYS RESIDENTIAL CODE REQUIREMENTS AS NOTED. ~p..nuf:' >- ISMA~

STAIR BUILDING CODE 2009 International Residential Code. Visual Interpretation of the

External Timber Stairs

WALKS AND SIDEWALKS REQUIREMENTS:

COPYRIGHTED MATERIAL. Chapter 1. Stairs

Code Compliance Research Report CCRR-0155

E100-09/10, Part I , (IFC [B] , )

When is a Building Permit Required? Deck Details: What Must be Submitted with a Building Permit Application?

PATHWAY 3G MODULAR ACCESS SYSTEM

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

Deck Evaluation Checklist

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

Chapter 4. Accessible Routes

Compliance with this acceptable construction practice satisfies Performance Requirement P2.5.2 for balustrades or other barriers.

The maximum back wall height is eight-feet three-inches (8 3 ), including truss, and is allowed only in the rear half of the booth space.

404 Doors, Doorways, and Gates

Spiral Stairs Endeman s Ironcraft Ltd PH/FAX:

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

ATI Evaluation Service A Division of Architectural Testing Certification Services

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

APPLICATION FOR A BUILDING PERMIT

2018 StairCraft Awards

DECK PERMIT APPLICATION PACKET

BRACKET FIX SYSTEM FITTING INSTRUCTIONS

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

2018 StairCraft Awards

Article 4.0 Measurements and Exceptions

How to Enhance Safety for the Long Escalator

Typical Deck Details

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

UNIT 6 Finish Carpentry

Rake Pass Through CR-KW Rake Down CR-310D-36. Rake Up CR-310U-36 2 x /32. Rake Pass Through CR Rake Down CR-KW310D-36

Architrave: The molded from or ornament surrounding a window, door or other rectangular opening.

Typical Deck Details

Maryland Building Officials Association Typical Deck Details

What is stairs? steps.

MEETING CALLED TO ORDER at 1:40 p.m. by Chair Kenneth Winters. ROLL CALL Members Present: (4) K. Winters, S. Callan, R. Hart and A.

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

ATI Evaluation Service A Division of Architectural Testing Certification Services

Typical Deck Details

ph fax

Perennial Wood Decking Installation Guide

Deck Design Guide. One and Two Family Residential Dwellings

Multi-Stage ASSEMBLY INSTRUCTIONS ST-8100 SERIES. 125 TAYLOR PARKWAY ARCHBOLD, OH PHONE: (419) FAX: (419)

STAIRSERVICE.COM. Stair system design and selection catalog. A step ahead, a step above 1 (800) Fax (408)

COMPOSITE RAILING INSTALLATION

Vertical Offset Base and Safety Rail System Installation Instructions

B E S P O K E S T A I R C A S E S

City of Virginia Beach, Virginia Typical Deck Details

Wood. collections. Hampton. Carolina. Colonial. Craftsman Box Newels

GLOSSARY OF STAIR PARTS TERMS

A Step-by-Step How To Guide

OSBRE LTD. 92 Green Lane, Thornhill, Ont. L3T 6K9 Tel: Fax:

2015 Feeney (8/15) # D. Aluminum Railing Systems

Build Outdoor Stairs. Stair Building Terms There are five basic design elements you'll need to consider when planning outdoor stairs:

PAINT & MISC. Notes. Table of Contents. Front Handrail Posts Front Handrails Closet Shelving Exterior Deck...

Columns and Railings ALUMINUM & VINYL AFCO-RAIL STRUCTURE STYLE

ASSEMBLY INSTRUCTIONS TF Tent Flooring System. 125 Taylor Parkway Archbold, Ohio Phone: (419) Fax: (419)

Columns and Railings ALUMINUM & VINYL AFCO-RAIL STRUCTURE STYLE

2018 StairCraft Awards

FILE UPDATE IRON STAIR RAILING EBOOK

2018 StairCraft Awards. Entry 06. Best Balustrade. Entry Criteria

Aluminum Railing Installation. Glass Railing Spindle Railings Intimacy Railings and Panels

installation care & maintenance instructions moistureshield.com limited lifetime warranty

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

KEYS TO COMPLIANCE ASSEMBLY AND MERCANTILE OCCUPANCIES ACCESSIBLE TOILET COMPARTMENTS. Figure 16 Handrail cross section {505.7}

Bedroom Window Egress

GUIDELINES FOR MEASURING BUILDING HEIGHT

House Design Tutorial

Info Sheet PowerSTAIRS Software

Staircase and Handrail Parts

ASSEMBLY INSTRUCTIONS

Drawing a Living Room and Family Room Floorplan

2013 Feeney (2/14) # B. Aluminum Railing Systems

Figure 1. RAILING INSTALLATION The following instructions describe the installation of three types of railing sections: Line, Stair, and Angled

PLAN SUBMITTAL REQUIREMENTS

2010 Collection. Architectural wainscoting that make a lasting Impression. Innovative designs & quality craftsmanship

2010 Collection. Architectural wainscoting that make a lasting Impression. Innovative designs & quality craftsmanship

C A R I B B E A N E X A M I N A T I O N S C O U N C I L REPORT ON CANDIDATES WORK IN THE SECONDARY EDUCATION CERTIFICATE EXAMINATION MAY/JUNE 2010

Introduction. to Wall Bracing

TO WHOM IT MAY CONCERN:

ROOFING City of Grand Rapids Building Safety Division

INSTALLATION GUIDE Timber Stairs

House Design Tutorial

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

SMALL PROJECTS & IMPROVEMENTS: DOG RUNS, PATIO ENCLOSURES & FENCES, EXTERIOR IMPROVEMENTS (Abbreviated Design Review Application)

Chapter 33: Lofts (Or Second Floors)

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

SUREWOOD ~ LNL. How to build a staircase like a pro. Post-To-Post Staircase System. Identify Your Type of Post-to-Post Staircase: Landing Newel Post

4. Components and Stairs

House Design Tutorial

SANTA MONICA BOULEVARD BEVERLY HILLS OWNER: 9908 SANTA MONICA BLVD., LLC SAN VICENTE BLVD. SUITE 550

Stairs. Whether the stair you need is simple or complex, free-standing or fully supported by walls, our staircases will definitely be eye-catching.

Slope Floor. Measurement Methods

Design Technology Architectural Design 2 The second in a sequence of courses that prepares individuals with knowledge of residential architectural

2018 Technical Drawing Specifications Resource A guide to support VCE Visual Communication Design Study Design

CITY OF PINE CITY SMALL WIRELESS FACILITY DESIGN GUIDELINES

602.4, TABLE 602.4, , , , , , , , , TABLE

Transcription:

Visual Interpretation Of The I N T E R N A T I O N A L R E S I D E N T I A L CO D E 2004 FLORIDA RESIDENTIAL STAIR BUILDING CODE (with 2005 amendments) Portions of this document reproduce sections from the 2003 International Residential Code, International Code Council, Falls Church, Virginia. Reproduced with permission. All rights reserved.

The Stairway Manufacturers Association publishes visual interpretations of Building Codes to be accurate pictorial descriptive material void of editorial comment to aid in the understanding of the written text. We provide this document as a learning tool to aid designers, builders, homeowners, building officials, stair builders, and others in the shelter industry to accurately and consistently interpret the building code related to stairways. The SMA has participated in the model code development process since 1988. We support the International Code Council s development process through our membership and are recognized and respected for our responsible efforts at code reform and interpretation in addition to our trade and industry experience that we bring to the table. This experience and reputation is an asset to our continued efforts to provide safe stairways and reduce stairway accidents while allowing freedom of design, and aesthetic properties of preference. In addition to our experience in the code development process we use the commentaries published by the International Code Council as a resource for each visual interpretation. The SMA wishes to thank the ICC for their permission to print portions of the IRC and in full recognition of our responsibility to educate and inform we invite your feedback and comments. This document is provided electronically at no cost to those who wish to print it in whole from www.stairways.org. It is not to be copied or used in part or in any other publication. Printed copies are available to SMA members for the cost of shipping. If you find this document to be of significant value, then you will find it equally beneficial to associate with a member of the Stairway Manufacturer s Association (SMA). The members of the SMA have taken on the task of influencing the development of responsible and functional building codes. They are the very individuals effectively communicating consistent interpretation of each stair code. A resulting product of their effort is this Visual Interpretation. SMA members know their craft of Stair Design and Construction and they know Building Codes. You are encouraged to contact a member of the SMA before you begin your next stairway project. The Stair Industry Dedicated to Safety & Quality If your work is related to stairs and you can prescribe to the ethics and quality standards of the SMA you may qualify for membership. To learn more about the SMA go to www.stairways.org, or contact us at sma@stairways.org.

SECTION R311.5 STAIRWAYS R311.5.1 Width. Stairways shall not be less than 36 inches (914 mm) in clear width at all points above the permitted handrail height and below the required headroom height. PHOTO 1. Handrails shall not project more than 4.5 inches (114 mm) on either side of the stairway PHOTO 2 and the minimum clear width of the stairway at and below the handrail height, including treads and landings, shall not be less than 31.5 inches (787 mm) where a handrail is installed on one side and 27 inches (698 mm) where handrails are provided on both sides PHOTO 3. 4-1/2 MAXIMUM HANDRAIL PROJECTION Exception: The width of spiral stairways shall be in accordance with Section R311.5.8. See PHOTO 35 on page 12. PHOTO 2 36 CLEAR WIDTH TWO HANDRAILS- 27 ONE HANDRAIL- 31-1/2 PHOTO 1 PHOTO 3 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 3

R311.5.2 Headroom. The minimum headroom in all parts of the stairway shall not be less than 6 feet, 8 inches (2036 mm) measured vertically from the sloped plane adjoining the tread nosing PHOTO 4 or from the floor surface of the landing or platform. PHOTO 5. HEADROOM 6-8 HEADROOM 6-8 PHOTO 5 R311.5.3 Stair treads and risers. PHOTO 4 R311.5.3.1 Riser height. The maximum riser height shall be 73 4 inches (196 mm). The riser shall be measured vertically between leading edges of the adjacent treads. PHOTO 6. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3 8 inch (9.5 mm). PHOTO 7. R311.5.3.2 Tread depth. The minimum tread depth, exclusive of nosing, shall be not less than 9 inches (254 mm). PHOTO 8. Treads and risers of stairs shall be permitted to be so proportioned that the sum of two risers and a tread, exclusive of nosing, is not less than 24 inches nor more than 25 inches. DRAWING 9. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread s leading edge. PHOTO 8. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3 8 inch (9.5 mm). PHOTO 10. Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 4

MAXIMUM RISE 7-3/4 THE SUM OF TWO RISERS AND A TREAD IS NOT LESS THAN 24 INCHES NOR MORE THAN 25 INCHES. R + R + T = SUM T 10 T 10 R 7-3/4 R 7 PHOTO 6 7-3/4 + 7-3/4 + 10 = 25-1/2 25-1/2 EXCEEDS LIMITS 7 + 7 + 10 = 24 24 IS WITHIN LIMITS GREATEST RISE 7-3/4 SMALLEST RISE 7-3/8 = 3/8 DRAWING 9 7-3/8 7-5/8 SAMPLE STAIR IS WITHIN ACCEPTABLE CODE LIMITS 7-5/8 10-1/8 GREATEST TREAD DEPTH 10-3/8 SMALLEST TREAD DEPTH 10 = 3/8 10-3/8 10 SAMPLE STAIR IS WITHIN ACCEPTABLE CODE LIMITS 7-5/8 10 PHOTO 7 7-3/4 10 DEPTH 9 PHOTO 10 PHOTO 8 Winder treads shall have a minimum tread depth of 10 inches (254 mm) measured as above at a point 12 inches (305 mm) from the side where the treads are narrower. DRAWING 11. Winder treads shall have a minimum tread depth of 6 inches (152 mm) at any point. DRAWING 12. Within any flight of stairs, the greatest winder tread depth at the 12 inch (305 mm) walk line shall not exceed the smallest by more than 3 8 inches (9.5 mm). Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 5

10 10 12 10 WIDTH AT WALKLINE WALKLINE INSIDE WIDTH 6 DRAWING 11 12 DRAWING 12 12 WINDER - A tread with non-parallel edges (as defined in Chapter 2 - IRC, IBC). ALTERNATE WINDER TREAD DESIGNS Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 6

R311.5.3.3 Profile. The radius of curvature at the leading edge of the tread shall be no greater than 9 / 16 inch (14.3 mm). PHOTO 13. Every tread less than 10 inches wide shall have a nosing or effective projection of approximately 1 inch over the level immediately below the tread. PHOTO 14. Beveling of nosing shall not exceed 1 2 inch (12.7 mm). PHOTO 15. Risers shall be vertical or sloped from the underside of the leading edge of the tread above at an angle not more than 30 (0.51 rad) degrees from the vertical. PHOTO 16. Open risers are permitted, provided that the opening between treads does not permit the passage of a 4-inch diameter (102 mm) sphere. PHOTO 17. Exceptions: 1. A nosing is not required where the tread depth is a minimum of 11 inches (279 mm). 2. The opening between adjacent treads is not limited on stairs with a total rise of 30 inches (762 mm) or less. PHOTO 17. PHOTO 16 30 SLOPE OF RISER MAY NOT EXCEED 30 PHOTO 13 RADIUS OF CURVATURE CANNOT EXCEED 9/16 MODIFIED TO RESTRICT PASSAGE OF A 4 SPHERE IF TOTAL RISE IS LESS THAN 30, 4 SPHERE RULE DOES NOT APPLY IF TREAD IS LESS THAN 10 (see PHOTO 9), EFFECTIVE NOSING PROJECTION IS APPROXIMATELY 1 INCH. NOTE: SEE EXCEPTION 1 ABOVE PHOTO 14 PHOTO 17 1/2 MAXIMUM BEVEL PHOTO 15 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 7

R311.5.4 Landings for Stairways. There shall be a floor or landing at the top and bottom of each stairway. Exception: A door at the top of a stair shall be permitted to open directly at a stair provided the door does not swing over the stair. A flight of stairs shall not have a vertical rise greater than 12 feet (3658 mm) between floor levels or landings. The width of each landing shall not be less than the stairway served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. DRAWING 18. DOWN STAIR WIDTH=A 36 DRAWING 18 DIRECTION OF TRAVEL 36 R311.5.5 Stairway walking surface. The walking surface of treads and landings of stairways shall be sloped no steeper than one unit vertical in 48 inches horizontal (2-percent slope). PHOTO 19. UP LANDING WIDTH=A OR MORE LANDING WIDTH=B OR MORE STAIR WIDTH=B NOT MORE THAN 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (2% SLOPE) 2% 2% R311.5.6 Handrails. *(see note page 13) Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. DRAWING 20. R311.5.6.1 Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). PHOTO 21. Exception: When fittings are used to provide transition between flights, transition from handrail to guardrail, or used at the start of a stair, the handrail height at the fitting, shall be permitted to exceed the maximum height. DRAWING 22. RAKE RAIL HEIGHT MIN. = 34 MAX. = 38 PHOTO 21 FLIGHT 2 Wall on left side of lower flight removed for clarity. DRAWING 20 38 MAX. HT. FLIGHT 1 FITTINGS USED TO PROVIDE TRANSITION SHALL BE PERMITTED TO EXCEED THE MAXIMUM HEIGHT. 34 MAXIMUM SLOPE 10 TREAD DEPTH + 1-1/4 NOSING =.2344 PHOTO 19 DRAWING 22 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 8

R311.5.6.2 Continuity. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top nosing edge of the flight to a point directly above the lowest nosing edge of the flight. DRAWING and PHOTO 23. Handrail ends shall be returned PHOTO 24 or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than 11 2 inches (38 mm) between the wall and the handrails. PHOTO 25. Exceptions: 1. Handrails shall be permitted to be interrupted by a newel post at the turn and at the top of the flight. PHOTO 26. 2. The use of a volute, turnout, starting easing or newel shall be allowed over the lowest tread. PHOTO 27. HANDRAIL MAY BE INTERRUPTED BY A NEWEL FLIGHT 2 HANDRAIL MUST BE CONTINUOUS PHOTO 26 FLIGHT 1 DRAWING 23 HANDRAIL ENDS SHALL BE RETURNED PHOTO 23 VOLUTES, TURNOUTS AND STARTING EASINGS ARE ALLOWED OVER THE LOWEST TREAD STARTING EASING 1-1/2 PHOTO 24 HANDRAIL CLEARANCE TURNOUT PHOTO 25 VOLUTE STARTING NEWEL PHOTO 27 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 9

R311.5.6.3 Handrail grip size. All required handrails shall be of one of the following types or provide equivalent graspability. DRAWING 28. Profiles other than Type I and Type II may be determined to provide equivalent graspability. 1. Type I. Handrails with a circular cross section shall have an outside diameter of at least 11 4 inches (32 mm) and not greater than 2 inches (51 mm). PHOTO 29. If the handrail is not circular it shall have a perimeter dimension of at least 4 inches (102 mm) and not greater than 61 4 inches (160 mm) with a maximum cross section of dimension of 21 4 inches (57 mm). PHOTO 30. CIRCULAR DIAMETER 1-1/4 MAXIMUM 2 1-3/4 PHOTO 29 NON-CIRCULAR MAX 2-1/4 METAL MAX 2-1/4 3-1/4 3-5/8 PHOTO 30 PERIMETER 4 MAXIMUM 6-1/4 DRAWING 28 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 10

2. Type II. Handrails with a perimeter greater than 61 4 inches (160mm) shall provide a graspable finger recess area on both sides of the profile. PHOTO 31. The finger recess shall begin within a distance of 3 4 inch (19 mm) measured vertically from the tallest portion of the profile and achieve a depth of at least 5/16 inch (8mm) within 7 8 inch (22mm) below the widest portion of the profile. PHOTO 32. This required depth shall continue for at least 3 8 inch (10mm) to a level that is not less than 13 4 inches (45 mm) below the tallest portion of the profile. PHOTO 33. The minimum width of the handrail above the recess shall be 11 4 inches (32 mm) to a maximum of 23 4 inches (70 mm). PHOTO 34. Edges shall have a minimum radius of 0.01 inches (0.25 mm). PHOTO 34. PERIMETER GREATER THAN 6-1/4 FINGER RECESS AREA BOTH SIDES } PHOTO 31 WITHIN 3/4 FINGER RECESS BEGINS WITHIN 7/8 OF WIDEST PORTION ACHIEVE 5/16 DEPTH PHOTO 32 } TALLEST PORTION TALLEST PORTION ACHIEVE 5/16 DEPTH CONTINUED FOR AT LEAST 3/8 PHOTO 33 EDGE RADIUS 0.01 PHOTO 34 1-3/4 TO A LEVEL NOT LESS THAN 1-3/4 WIDTH ABOVE RECESS 1-1/4 MAXIMUM 2-3/4 R311.5.7 Illumination. All stairs shall be provided with illumination in accordance with Section R303.6. Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 11

R311.5.8 Special stairways. Circular stairways, spiral stairways, winders and bulkhead enclosure stairways shall comply with all requirements of Section R311.5 except as specified below. R311.5.8.1 Spiral Stairs. Spiral stairways are permitted, provided the minimum width shall be 26 inches (660 mm) with each tread having a 71 2 inch (190 mm) minimum tread depth at 12 inches from the narrower edge. All treads shall be identical, and the rise shall be no more than 91 2 inches (241 mm). A minimum headroom of 6 feet, 6 inches (1982 mm) shall be provided. Handrails shall be provided on one side. PHOTO 35. DOWN COUNTER CLOCKWISE 26 MIN. 7-1/2 MIN. TREAD WIDTH 12 R311.5.8.2 Bulkhead enclosure stairways. Stairways serving bulkhead enclosures, not part of the required building egress, providing access from the outside grade level to the basement shall be exempt from the requirements of Sections R311.4.3 and R311.5 where the maximum height from the basement finished floor level to grade adjacent to the stairway does not exceed 8 feet (2438 mm), and the grade level opening to the stairway is covered by a bulkhead enclosure with hinged doors or other approved means. R311.5.8.3 Circular Stairways. Circular stair may have a minimum tread depth of 9 inches with 1 inch (25.4 mm) of nosing, and the smaller radius may be less than twice the width of the stairway. DRAWING 36. SECTION R312 GUARDS R312.1 Guards required. *(see note page 13) Porches, balconies or raised floor surfaces located more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 36 inches (914 mm) in height. Open sides of stairs with a total rise of more than 30 inches (762 mm) above the floor or grade below shall have guards not less than 34 inches (864 mm) in height measured vertically from the nosing of the treads. PHOTO 37. Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is located more than 30 inches (762 mm) above the floor or grade below. HEADROOM 6-6 GUARD 34 BALCONY GUARD 36 9-1/2 MAXIMUM RISE IF TOTAL RISE IS OVER 30... PHOTO 35 PHOTO 37 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 12

9 WALK LINE 12 9 R 36 48 MUST NOT ALLOW PASSAGE OF 4 SPHERE DRAWING 36 CIRCULAR STAIRS MAY HAVE A TREAD DEPTH OF 9 INCHES... THE SMALLER RADIUS MAY BE LESS THAN TWICE THE WIDTH OF THE STAIRWAY. R312.2 Guard opening limitations. Required guards on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches (102 mm) or more in diameter. PHOTO 38. Exception: 1. The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway are permitted to be of such a size that a sphere 6 inches (152 mm) cannot pass through. PHOTO 39. 2. Openings for required guards on the sides of stair treads shall not allow a sphere 43 8 inches (107 mm) to pass through. PHOTO 39. PHOTO 38 MUST NOT ALLOW PASSAGE OF 4-3/8 SPHERE * NOTE: In Dade and Broward counties please seek the guidance of local code officials for HVHZ guard and handrail requirements. MUST NOT ALLOW PASSAGE OF 6 SPHERE PHOTO 39 Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 13

CHAPTER 2 DEFINITIONS R201.3 Terms Defined in other codes. Where terms are not defined in this code such terms shall have meanings ascribed to them as in other code publications of the International Code Council. Note: In order to assure a complete understanding in accordance with above we have listed all the stair related definitions from both the IRC and the IBC (International Building Code). IRC Section R202 Definitions GUARD. A building component or a system of building components located near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to a lower level. HANDRAIL. A horizontal or sloping rail intended for grasping by the hand for guidance or support. WINDER. A tread with nonparallel edges. IBC Section 1002 Definitions ALTERNATING TREAD DEVICE. A device that has a series of steps between 50 and 70 degrees (0.87 and 1.22 rad) from horizontal, usually attached to a center support rail in an alternating manner so that the user does not have both feet on the same level at the same time. GUARD. A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to a lower level. HANDRAIL. A horizontal or sloping rail intended for grasping by the hand for guidance or support. NOSING. The leading edge of treads of stairs and of landings at the top of stairway flights. SCISSOR STAIR. Two interlocking stairways providing two separate paths of egress located within one stairwell enclosure. STAIR. A change in elevation, consisting of one or more risers. STAIRWAY. One or more flights of stairs, either exterior or interior, with the necessary landings and platforms connecting them, to form a continuous and uninterrupted passage from one level to another. STAIRWAY, CIRCULAR. A stairway with steps that result in a sweeping circular or curved pattern, but not spiral. STAIRWAY, EXTERIOR. A stairway that is open on at least one side, except for required structural columns, beams, handrails and guards. The adjoining open areas shall be either yards, courts or public ways. The other sides of the exterior stairway need not be open. STAIRWAY, INTERIOR. A stairway not meeting the definition of an exterior stairway. STAIRWAY, SPIRAL. A stairway with steps that have a central connecting point and the travel path is a corkscrew or spiral. WINDER. A tread with nonparallel edges. Stairway Manufacturers Association Interpretation of Florida 2006 www.stairways.org Page No. 14

NOTES: cut on line and laminate for handy field/desk reference tool FULL SCALE TYPE II RAIL TEST Instructions: Position rail section with widest point of grip at line AB and left edge touching line AC. Keeping horizontal axis of rail parallel to line AB. With the rail in position, it must pass tests 1) thru 5) to meet the R315.2 Type II Handrail Grip Size requirements. If profile is asymmetrical both sides must pass. Reproduction check: solid line measures 2.75 in. Stairway Manufacturers Association www.stairways.org

THE MISSION OF THE SMA IS: To organize the varied elements of the stair industry into a leader in the code change process by actively participating at all levels. To write standards that insure design and installation criteria meet or exceed the minimum standard set forth by the existing code. To participate in design and product testing as to learn more about stair dynamics so that safety and aesthetics can coexist while incidences of stair accidents are reduced. To establish a central source that will disseminate to the membership current and proposed code information impacting all facets of stair building and millwork usage. To protect the rights and interests of both the consumer and the stair industry. The Stairway Manufacturers Association is dedicated to the prospect that safety and aesthetics, with respect to stairs, are not mutually exclusive... The SMA is a broad based industry association founded in 1988. Our members include stair parts manufacturers, stair builders, installers, millwork distributors, dealers and interested building products professionals. We are an industry organization run by industry people. Our primary focus is to represent the millwork industry to the building development groups at the local, country, state and national levels. Because the SMA represents the people who build, install and sell stair parts and stairways in this country, it is our purpose to defend, test, evaluate and promote products and standards that insure safety in conjunction with growth and prosperity of our industry. For more information about the association or becoming a member either write, call or visit our website. The Stairway Manufacturers Association Toll Free: 877-500-5759 Website: www.stairways.org Email: SMA@stairways.org IN SUPPORT OF THE STAIR INDUSTRY! Stairway Manufacturers Association Interpretation of IRC 2003 www.stairways.org