LeMeniz Infotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry Call: , ,

Similar documents
A Single Stage CCM Zeta Micro inverter for Solar Photovoltaic AC Module. Abstract

Ripple Minimization through Harmonic Elimination in Asymmetric Interleaved Multiphase dc-dc Converters

A Single-Phase Cascaded Multilevel Inverter Based on a New Basic Unit with Reduced Number of Power Switches

LeMeniz Infotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry Call: , ,

A High-Efficiency MOSFET Transformerless Inverter for Nonisolated Microinverter Applications

Sensorless Drive for High-Speed Brushless DC Motor Based on the Virtual Neutral Voltage

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM

Enhancement of Power Quality With Hybrid-Fuzzy Based Active Compensation Scheme for Grid Connected-Hybrid Power Generator

Single Inductor Dual Buck Full-Bridge Inverter

Damping and Harmonic Control of DG Interfacing. Power Converters

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Design of Single Phase Pure Sine Wave Inverter for Photovoltaic Application

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Design of Single-Stage Transformer less Grid Connected Photovoltaic System

CONCLUSIONS AND SUGGESTIONS FOR FUTURE WORK

APF technical features. APF technical principle. About. solution is adaptive for load increasing in power grid

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

DSTATCOM BASED POWER QUALITY IMPROVEMENT OF MICROGRID

IGBT based Multiport Bidirectional DC-DC Converter with Renewable Energy Source

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Grid-Voltage Regulation Controller: IUPQC

Coping Smartly!! with Harmonic Penetration, Propagation and Interaction in the Distribution Network. Dr. Malabika Basu

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

shunt (parallel series

Power Control and Quality Management in DG Grid Interfaced Systems

6. HARDWARE PROTOTYPE AND EXPERIMENTAL RESULTS

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

Photovoltaic System Based Interconnection at Distribution Level With Different Loads

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Control Of Shunt Active Filter Based On Instantaneous Power Theory

THREE PORT DC-DC CONVERTER FOR STANDALONE PHOTOVOLTAIC SYSTEM

POWER ISIPO 29 ISIPO 27

Unified Power Quality conditioner in Grid connected Photovoltaic System

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL

Literature Review for Shunt Active Power Filters

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Application Analysis of Electronic Power Transformer in Photovoltaic Power System

B.Tech Academic Projects EEE (Simulation)

Improvement of Power Quality with Hybrid Renewable Energy Sources Based Four Leg Inverter

CHAPTER 3 MODELLING OF PV SOLAR FARM AS STATCOM

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

Review on Shunt Active Power Filter for Three Phase Four Wire System

Power Quality Improvement in Fourteen Bus System using UPQC

Renewable Energy Source Compensator for Power Quality Issues Using Active Power Filter in Grid

VOLTAGE MULTISTABILITY FOR DISTRIBUTION SYSTEM

International Journal of Modern Trends in Engineering and Research. An Effective Wind Energy System based on Buck-boost Controller

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

Modelling of Five-Level Inverter for Renewable Power Source

MAXIMUM POWER POINT TRACKER FOR SOLAR CHARGE CONTROLLER APPLICATIONS

UPQC with Islanding and Grid Connection for Microgrid Applications

A High Efficiency and High Voltage Gain DC-DC Converter for Renewable Energy Connected to Induction Motor

Simulation Study of PWM Techniques for Voltage Source Converters

Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

Sensors (Transducer) Introduction By Sintayehu Challa

Design of a conditioner for smoothing wind turbine output power

ISSN Vol.03,Issue.07, August-2015, Pages:

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Cascaded Connection of Single-Phase & Three-Phase Multilevel Bridge Type Inverter

Maximum Power Point Tracking Implementation of Z-Source Inverter through Finite Step Model Predictive Control Strategy

ISSN Vol.04,Issue.16, October-2016, Pages:

Voltage Variation Compensation

Modeling and Simulation of a Novel Three-phase Multilevel Inverter with Induction Motor Drive

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Harmonic Stability in Renewable Energy Systems: An Overview

UPQC for Power Quality Improvement in DG Integrated Smart Grid Network: a Review

Control of Power Converters for Distributed Generation

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

Power Quality Improvement using Shunt Passive Filter

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

STUDY OF CIRCULATING CURRENT PHENOMENA IN MULTIPLE PARALLEL INVERTERS OPERATING IN MICROGRID

Shunt Active Power Filter connected to MPPT based photo voltaic Array for PQ enhancement

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Power Quality improvement of a three phase four wire system using UPQC

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

CHAPTER 7 CONCLUSIONS AND FUTURE SCOPE

Upgrading Power Quality of a Distributed Generation Power System

DC Link. Charge Controller/ DC-DC Converter. Gate Driver. Battery Cells. System Controller

Power electronic converters in power systems. SINTEF Energy Research

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

ANALYSIS OF ACTIVE POWER FILTER FOR HARMONIC VOLTAGE RESONANCE SUPPRESSION IN DISTRIBUTION SYSTEM

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Transcription:

Page number 1 A Novel Integrated Power Quality Controller for Microgrid Abstract Introduction: Distributed power generation has been emerged as a promising option to meet the growing customer needs for electric power with an emphasis on reliability and environmentally friendly renewable energy. In this context, in order to maximize the operational efficiency of the distributed energy res (DERs) and take full advantage of distributed power generation, as an effective means of integrating DERs into the traditional power grid, microgrid is presented, which can enhance the local customer power supply reliability and system performance, reduce the impact on large power grid, and minimize the system losses. Microgrid has good environmental and economical benefits and has attracted more and more attentions of power researchers. However, the power quality problem of microgrid is much more serious than that of the traditional grid because of the intermittency and randomness of DERs, the high penetration between conventional grid and microgrid, the diversity of DERs, load, energy conversion unit, storage, and operating state. Microgrid power quality has the following unique features compared with the conventional power grid.

Page number 2 Existing system: This method employs an integrator with reset as its core component to control the pulse width of an ac dc converter so that its current draw is precisely opposite to the reactive and harmonic current draw of the nonlinear loads. In contrast to all previously proposed methods, there is no need to generate a current reference for the control of the converter current, thus no need to sense the ac line voltage, the APF current, and the nonlinear load current. Only one current sensor and one voltage sensor (resister divider) are used to sense the ac main current and the voltage across the dc capacitor. The control method features constant switching frequency operation, minimum reactive and harmonic current generation, and simple analog circuitry. It provides a low cost and high performance solution for power quality control. Steady-state and dynamic analysis is performed that leads to the remedy of the dc offset related to peak current sensing and extension of the stability region. Proposed system: The novel IPQC can be installed in series and parallel in microgrid or point of common coupling (PCC). For simplicity, the IPQC is installed in PCC. The three-phase detailed system configuration of the IPQC with transformer and. Us and Ls represent the voltage and impedance of conventional

Page number 3 power supply, respectively. The passive filters, which have the function of absorbing the harmonics, are shunted in both sides. The primary winding of a transformer is inserted in series between the conventional power utility and the microgrid, whereas the secondary winding is connected with a voltage PWM converter. Ud is the voltage of the dc side of the. The microgrid contains a harmonic load, a photovoltaic cell system, a battery storage system, and a normal load. Block diagram:

5 V DC LeMeniz Infotech Page number 4 Passive filters Load Non linear Load Input DC supply Filter Input 1 12 V DC 3 phase driver circuit BUFFER circuit Filter Input 2 PIC controller circuit

Page number 5 Tools and software used: MPLAB microcontroller programming. ORCAD circuit layout. MATLAB/Simulink Simulation.