International Journal of Research Available at

Similar documents
Harmonic Mitigation in AC DC Converters for Induction Motor Drives by Vector Controlled

THE rapid development of power electronics in recent

Introduction to Rectifiers and their Performance Parameters

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Harmonics Elimination Using Shunt Active Filter

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

IMPLEMENTATION OF PERFORMANCE ANALYSIS OF 18-PULSE AC-DC CONVERTER FED SWITCHED RELUCTANCE MOTOR DRIVES TO ROBOTICS

ISSN Vol.03,Issue.07, August-2015, Pages:

Power quality improvement of self- excited induction generator using Multipulse AC-DC converters - A comparison

Power Quality Improvement using a 28-pulse AC-DC Converter for SMPS

Improvement of Power Quality by Using 28-Pulse AC-DC Converter

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

Effective Harmonic Mitigation with Active Filters

16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER, VARIATION OF HARMONICS AND RIPPLE WITH PULSE NUMBER Pulse Number

A 24-Pulse AC DC Converter Employing a Pulse Doubling Technique for Vector-Controlled Induction Motor Drives

Literature Review for Shunt Active Power Filters

Volume I Issue VI 2012 September-2012 ISSN

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Improving Passive Filter Compensation Performance With Active Techniques

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

CHAPTER 4 HARMONICS AND POWER FACTOR

COMPARATIVE ANALYSIS OF MULTIPULSE AC-DC CONVERTERS IN VCIMD

NPTEL

ISSN: [Vakula * et al., 7(8): August, 2018] Impact Factor: 5.164

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

New 24-Pulse Diode Rectifier Systems for Utility Interface of High-Power AC Motor Drives

COMPARISON OF POWER QUALITY SOLUTIONS USING ACTIVE AND PASSIVE RECTIFICATION FOR MORE ELECTRIC AIRCRAFT

Power Quality Analysis in Power System with Non Linear Load

Closed Loop Control of Multipulse Rectifier Using Novel Modulation Techniques

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Economical Solutions to Meet Harmonic Distortion Limits[4]

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

CHAPTER 1 INTRODUCTION

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Harmonics White Paper

7/15/2002 PP.AFD.08 1 of 28

An Active Interphase Transformer for 12-Pulse Rectifier System to Get the Performance Like 24- Pulse Rectifier System

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

Design and Simulation of Passive Filter

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

New Pulse Multiplication Technique Based on Six-Pulse Thyristor Converters for High-Power Applications

Power Control Scheme of D-Statcom

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

VARIABLE FREQUENCY DRIVE

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Study and analysis of THD and content of Harmonics in Three Phase PWM Inverter with Filters.

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Harmonic Distortion and Variable Frequency Drives

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

p. 1 p. 6 p. 22 p. 46 p. 58

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Power Factor & Harmonics

High Power Factor Bridgeless SEPIC Rectifier for Drive Applications

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Power Quality Improvement in Conventional Electronic Load Controller. for an Isolated Power Generation

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

Electromagnetic Harmonic Filters Technical Guide

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Power Quality Improvement in Induction Motor Drive using 24-Pulse AC-DC Converter Employing Pulse Multiplication Technique

Vienna Rectifier Fed BLDC Motor

IMPACT OF VARIABLE FREQUENCY DRIVES ON ELECTRICAL SYSTEM

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

AC Drives and Soft Starter Application Guide

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

Figure 1 Typical Inverter Block Diagram

Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation

Power Quality enhancement of a distribution line with DSTATCOM

SHUNT ACTIVE POWER FILTER

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Power Quality Analysis: A Study on Off-Line UPS Based System

A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection

Type of loads Active load torque: - Passive load torque :-

VIENNA RECTIFIER FED BLDC MOTOR

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

REDUCTION OF ZERO SEQUENCE VOLTAGE USING MULTILEVEL INVERTER FED OPEN-END WINDING INDUCTION MOTOR DRIVE

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC

Analysis of Harmonic Distortion in Non-linear Loads

SRI VIDYA COLLEGE OF ENGG AND TECH

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Transcription:

Multipulse Ac Dc Converters With Reduced Magntetics Feeding Vector Controlled Induction Motor Drives For Improving The Power Quality At The Point of Common Coupling M. Akhila 1 Dr.Samalla Krishna 2 Mr.S.Srikanth 3 1 M. Tech Student Deptt of of Electrical & Electronics Engg. Tudi Ram Reddy Institute of Technology&Sciences, Hydearabad.akhilareddy226@gmail.com 2 Professors, & Principal. Tudi Ram Reddy Institute of Technology&Sciences, Hydearabad. Krishna.oume@gmail.com 3 Assistant Professor, Department of Electrical & Electronics Engg. Tudi Ram Reddy Institute of Technology & Sciences, Hydearabad. Ssrikanth674@gmail.com ABSTRACT The main aim of project is auto transformerbased multipulse ac dc converters with reduced magnetics feeding vector controlled induction motor drives for improving the power quality at the point of common coupling. The proposed 12-pulse ac dc converter-based harmonic mitigator consists of an autotransformer along with a passive shunt filter tuned for 11th harmonic frequency. This results in the elimination of 5th, 7th, and 11th harmonic currents. Similarly, the proposed 18-pulse ac dc converter based harmonic mitigator eliminates the 5th, 7th, 11th, 13th, and 17thharmonic currents, thereby improving the power quality at ac mains. The simulation results carried out on the developed of autotransformers-based ac dc converters. Index terms: Auto transformer based multipulse ac dc converter, induction motor, Power quality, Passive shunt filter 1.INTRODUCTION In order to prevent the harmonics from affecting the utility lines negatively, an Standard 519 has been reissued in 1992 giving clear limits for voltage and current distortions. Several methods based on the principle of increasing the number of rectification pulses in ac-dc converters have been reported in the literature. The conventional wye-delta transformer based 12-pulse rectifier ion scheme is one such example. But the kv A rating of the transformer is 1.03 PO, where PO is the active power drawn by the converter. To reduce the transformer rating, autotransformer based multipulse ac-dc converters of reduced rating have been reported in the literature. For applications where the demand for harmonic current reduction is more stringent, an 18- pulse ac-dc converter is generally preferred. This converter is more economical than the 24-pulse ac-dc converter, while being more effective than the 12-pulse ac-dc converter. Autotransformer based 18-pulse ac-dc converters have been reported in for reducing the THD of ac mains current. However, the dc-link voltage is higher, making the scheme non applicable for retrofit applications. Hammond has proposed a new topology, but the transformer design is very complex to the transformer design. Paice has reported a new topology for 18-pulse converters. But the THD of ac mains current with this topology is around 8% at full load. Kamath et.al. Have also reported an 18-pulse converter, but THD of ac mains current is high even at full load (6.9%) and as load decreases the THD increases further (13.1%THD at 50% load). In Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1214

this paper, a novel autotransformer based 18- pulse ac-dc converter (Topology D ), which is suitable for retrofit applications, where presently 6 pulse converter is being used, referred as Topology 'A', have been proposed to feed VCIMD. The proposed ac-dc converter results in elimination of 5th, 7th, 11th and 13th harmonics. A set of tabulated results giving the comparison of the different power quality parameters is presented for a VCIMD fed from an existing 6- pulse ac-dc converter and different 18 pulse acdc converter. Moreover, the effect of load variation on various power quality indices is also studied. To demonstrate the effectiveness of proposed 18- pulse ac-dc converter feeding VCIMD. A laboratory prototype of the proposed autotransformer is designed and the developed and different tests have been carried out to validate the working of the proposed harmonic mitigator. The test results are found to be in close agreement with the simulated results under different operating and loading conditions. 2.HARMONICS The typical definition for a harmonic is a sinusoidal component of a periodic wave or\ quantity having a frequency that is an integral multiple of the fundamental frequency. [1]. Some references refer to clean or pure power as those without any harmonics. But such clean waveforms typically only exist in a laboratory. Harmonics have been around for a long time and will continue to do so. In fact, musicians have been aware of such since the invention of the first string or woodwind instrument. Harmonics (called overtones in music) are responsible for what makes a trumpet sound like a trumpet, and a clarinet like a clarinet. Electrical generators try to produce electric power where the voltage waveform has only one frequency associated with it, the fundamental frequency. In the North America, this frequency is 60 Hz, or cycles per second. In European countries and other parts of the world, this frequency is usually 50 Hz. Aircraft often uses 400 Hz as the fundamental frequency. At 60 Hz, this means that sixty times a second, the voltage waveform increases to a maximum positive value, then decreases to zero, further decreasing to a maximum negative value, and then back to zero. The rate at which these changes occur is the trigometric function called a sine wave, as shown in figure 1. This function occurs in many natural phenomena, such as the speed of a pendulum as it swings back and forth, or the way a string on a voilin vibrates when plucked 3. OPERATING PRINCIPLE OF PROPOSED SYSTEM Variable frequency drives often have strict demands placed on them to mitigate harmonic distortion caused by non-linear loads. Many choices are available to them including line reactors, harmonic traps, 12-pulse rectifiers, 18- pulse rectifiers and low pass filters. Some of these solutions offer guaranteed results and have no adverse effect on the power system, while the performance of others is largely dependent on system conditions. Certain techniques require extensive system analysis to prevent resonance problems and capacitor failures, while others can be applied with virtually no analysis whatsoever. In some cases harmonic mitigation technique decisions were based on a technical misunderstanding, lack of informat ion, theoretical data or on invalid assumptions. This Chapter explains the theory of operation of various passive harmonic mit igation techniques and demonstrates their typical real life performance. It takes the guesswork Out of harmonic filtering by demonstrating the typical Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1215

performance of various harmonic mitigation techniques and offering a quantitative analysis of alternatives for real life VFD Operating conditions. Since power distribution transformers frequently have impedance ratings between 1.5% and 5.75%, one would expect that source. diodes at the in put to the VFD, as shown in Fig The use of AC line reactors is a common and economical means of increasing the source impedance relative to an individual load. Line reactors are connected in series with the six pulse rectifier Fig1. AC line reactors connection at supply side The typical harmonic spectrum data for a six pulse VFD load fed by a power supply with an Effective source reactance of 3%, 5% and 8% looks as follows: These data represent the harmonics measured at the input to the six pulse rectifier and will reduce to lower percentages when measured further upstream, provided there are other linear loads operating on the system. If 20% of the system load is comprised of VFDs with 5% input impedance, and 80% has linear loads, the harmonic current distortion at the VFD input will be 35% THID, but only 7% at the supply transformer secondary. Typically costing less than 3% of the motor drive system, line reactors are the most economical means of reducing harmonics. Practical ratings can achieve 29% to 44% THID at the input to the six pulse Tuned Harmonic Trap Filters: Harmonic Trap Performance: Tuned harmonic filters (traps) involve the series connection of an inductance and capacitance to form a low impedance path for a specific (tuned) harmonic frequency. The filter is connected in parallel (shunt) with the power system to divert the tuned frequency currents away fro m the power source.. Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1216

Fig2 Harmonic Trap Performance with 0.25% source impedance 4. VECTOR CONTROL The various control strategies for the control of the inverter-fed induction motor have provided good steady state but poor dynamic response. From the traces of the dynamic responses, the cause of such poor dynamic response is found to be that their air gap flux linkages deviate from their set values. The deviation is not only in magnitude but also in phase. The variations in the flux linkages have to be controlled by the magnitude and frequency of the stator and rotor phase currents and instantaneous phases. The oscillations in the air gap flux linkages result in oscillations in electromagnetic torque and, if left unchecked, reflect as speed oscillations. This is undesirable in many high- performance applications. Air gap flux variations result in large excurs ions of stator currents, requiring large peak converter and inverter ratings to meet the dynamics. An enhancement of peak inverter rating increases cost and reduces the competitive edge of ac drives over dc drives. Separately 5. SIMULATION RESULTS excited dc drives are simple in control because they independently control flux, which when maintained constant contributes to an independent control of torque. This is made possible with separate control of field and armature currents, which in turn control the field flux and the torque independently. Moreover, the dc motor control requires only the control of the field or armature current magnitudes. As with the dc drives, independent control of the flux and torque is possible in ac drives The stator current phasor can be resolved, say, along the rotor flux linkages, and the component along the rotor flux linkages is the field producing current, but this requires the position of the rotor flux linkages at every instant; note that this is dynamic, unlike in the dc machine. If this is available, then the control of ac machines is very similar to that of separately excited dc machines. The requirements of phase, frequency, and magnitude control of the currents and hence of the flux phasor are made possible by inverter control. The control is achieved in field 1) EXISTING SIX PULSE AC-DC-AC PWM CONVERTER Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1217

Fig 3. pulse AC-DC-AC Converter Fig 4. DC Voltage, inverter voltage, load voltage Fig5. THD % of Inverter voltage Fig6.THD of Load Volatge Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1218

2) PROPOSED 12 PULSE AC-DC CONVERTER Fig 7. Proposed 12 Pulse AC-DC converter with harmonic trap Fig 8. voltage and currents of Bus1 and Bus2 Fig 9. THD % of Current CONCLUSION The proposed harmonic mitigator has been observed suitable for retrofit applications with variable frequency induction motor drives operating under varying load condit ions.the performance of the proposed harmonic mitigator fed VCIMD under varying load conditions is found to be satisfactory. The proposed harmonic mitigator has resulted in reduction in rating of the magnetics leading to the saving in overall cost of the drive.the observed performance of the proposed harmonic mitigator has demonstrated the capability of this converter to improve the power quality indices at ac mains in terms of THD of supply current, THD of supply Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1219

voltage, power factor and crest factor. On the dc link side too, there is a remarkable improvement in ripple factor of dc link voltage. REFERENCES 1.P.Vas, Sensorless vector and direct torque control, Oxford Universit Press, 1998. 2. IEEE Guide for harmonic control and reactive compensation of Static Power Converters, IEEE Std. 519-1992. 3. D. A. Paice, Power Electronic Converter Harmonics: Multipulse Methods for Clean Power, New York, IEEE Press 1996. 4. S.Martinius, B.shalimi and P.A.Cahono, "A transformer connection for multipulse rectifier applications," Proc. Int. Conf. Powercon, Oct.2002,vol.22,pp.1021-1024 AUTHOR S PROFILE more than 35 research papers in reputed International Journals. He shared his research experience more than many podiums like conferences, workshops, seminars and symposia. And currently he is working as a professor in TUDI Group of institutions, Hyderabad. He has 12 years of experience in the teaching and research field. His many research articles are cited by scholars and research institutions. MR. S.SRIKANTH is a Post Graduated from the field of Electrical Engineering. He has 3 years of teaching experiences for Graduate and Post Graduate engineering courses. He has published her research work many International Journals and conferences. He guided several engineering students for their academic projects. DR. SAMALLA KRISHNA so far has successfully guided many post graduate students in the fields of Signal and Image Processing, Neural Networks and Pattern Recognition while several other students are being supervised by him in a wide variety of other fields like DSP, Medical Image Processing and Object Recognition in addition to this he supervised many electrical and other disciplinary engineering students.he served as an academic supervisor to more than 300 Bachelor Degree dissertations towards the award of Undergraduate Degree,and He has published M. Akhila, PG Student of Electrical, Tudi Ram Reddy Institute of Technology& Sciences, Telangana, India. She did bachelor degree from Jaya Prakash Narayan Educational Socity, Telangana, India Available online: http://edupediapublications.org/journals/index.php/ijr/ P a g e 1220