WP640 Imaging Colorimeter. Backlit Graphics Panel Analysis

Similar documents
DEFINING A SPARKLE MEASUREMENT STANDARD FOR QUALITY CONTROL OF ANTI-GLARE DISPLAYS Presented By Matt Scholz April 3, 2018

Imaging Photometer and Colorimeter

MEASURING HEAD-UP DISPLAYS FROM 2D TO AR: SYSTEM BENEFITS & DEMONSTRATION Presented By Matt Scholz November 28, 2018

A High-Speed Imaging Colorimeter LumiCol 1900 for Display Measurements

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

IMPROVING AUTOMOTIVE INSPECTION WITH LIGHT & COLOR MEASUREMENT SYSTEMS

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

operating manual iliad for Windows & Mac OS X software application rc81

Be aware that there is no universal notation for the various quantities.

Novel Approach for LED Luminous Intensity Measurement

Color Measurement with the LSS-100P

APPLICATIONS OF HIGH RESOLUTION MEASUREMENT

Measurement of Visual Resolution of Display Screens

Active Stereo Vision. COMP 4102A Winter 2014 Gerhard Roth Version 1

REPLICATING HUMAN VISION FOR ACCURATE TESTING OF AR/VR DISPLAYS Presented By Eric Eisenberg February 22, 2018

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

How to Properly Select a Laser Power or Energy Sensor

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

WHITE PAPER. Methods for Measuring Flat Panel Display Defects and Mura as Correlated to Human Visual Perception

WHITE PAPER. Guide to CCD-Based Imaging Colorimeters

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

iq-led Software V2.1

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

Quick Start Overview. Related Information. In addition, the sensor includes integrated Help.

AgilEye Manual Version 2.0 February 28, 2007

Coherent Laser Measurement and Control Beam Diagnostics

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

ACDC56-41QBWA/D-F01 Surface Mount Display

Single Photon Interference Katelynn Sharma and Garrett West University of Rochester, Institute of Optics, 275 Hutchison Rd. Rochester, NY 14627

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

In-Vivo Imaging: IVIS Lumina XR. William R. Anderson IVIS Product Specialist

APTF1616SEEZGQBDC. 1.6 x 1.6 mm Full-Color Surface Mount LED DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS ATTENTION SELECTION GUIDE

ONE OF THE MOST IMPORTANT SETTINGS ON YOUR CAMERA!

FPD IN-LINE SPECTRAL TESTING SOLUTION

LIGHT READING - VCSEL TESTING

ULS24 Frequently Asked Questions

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

ivu Plus Quick Start Guide P/N rev. A -- 10/8/2010

APHCM2012SURCK-F x 1.25 mm SMD CHIP LED LAMP

Cvision 2. António J. R. Neves João Paulo Silva Cunha. Bernardo Cunha. IEETA / Universidade de Aveiro

Chameleon Spectroradiometer

specification display & lighting hera spectrometer

MRI Grid. The MRI Grid is a tool in MRI Cell Image Analyzer, that can be used to associate measurements with labeled positions on a board.

Information & Instructions

4.5.1 Mirroring Gain/Offset Registers GPIO CMV Snapshot Control... 14

LED Lighting Flux and Color Measurement System (LFC)

Highest Resolution: 5400 dpi (optical) Finest Image Quality due to employing sophisticated Grain Dissolver Comfortability: Digital ICE Manual Focus

Use of Photogrammetry for Sensor Location and Orientation

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

GlassSpection User Guide

WHITE PAPER. Methods for Measuring Display Defects and Mura as Correlated to Human Visual Perception

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Basler. Line Scan Cameras

APHF1608SEEQBDZGKC. 1.6 x 0.8 mm Full-Color Surface Mount LED

Image acquisition. In both cases, the digital sensing element is one of the following: Line array Area array. Single sensor

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Technical Note How to Compensate Lateral Chromatic Aberration

WP154A4SEJ3VBDZGW/CA T-1 3/4 (5mm) Full Color LED Lamp

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

COLORMUNKI DISPLAY & i1display PRO

Locating Molecules Using GSD Technology Project Folders: Organization of Experiment Files...1

GXCapture 8.1 Instruction Manual

How to combine images in Photoshop

Optika ISview. Image acquisition and processing software. Instruction Manual

Solid State Luminance Standards

Whether for quality control, sorting, or

Automated Solutions for SAE Standard HUD Measurement

Kingbright. L-169XID 2 x 3mm Rectangular Solid Lamp DESCRIPTION PACKAGE DIMENSIONS FEATURES APPLICATIONS SELECTION GUIDE

BTS2048-VL-CP-ILED-B-IS-1.0-HL

PICO MASTER 200. UV direct laser writer for maskless lithography

The Science Seeing of process Digital Media. The Science of Digital Media Introduction

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

SPEC NO: DSAB8533 REV NO: V.19A DATE: AUG/16/2014 PAGE: 1 OF 7 APPROVED: WYNEC CHECKED:

Descriptions. The Hyper Red device is based on light emitting diode Ideal for backlight and indicator.

Kingbright. L-3VEGW T-1(3mm) Bi-Color Indicator Lamp DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS SELECTION GUIDE

AAA3528QWDSURKS. 3.5 x 2.8 mm Surface Mount LED Lamp DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS ATTENTION SELECTION GUIDE

ChemiDoc-It Imaging System

Ultimate and Versatile 2D Spectroradiometer is finally released!

COLOR CONTRAST AND LUMINESCENCE SENSORS

APTD1608LCGCK 1.6 x 0.8 mm SMD Chip LED Lamp

Color and perception Christian Miller CS Fall 2011

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

SCD-0017 Firegrab Documentation

Description. Kingbright

WP154A4SUREQBFZGC T-1 3/4 (5mm) Full Color LED Lamp

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

HDR videos acquisition

Zeiss 880 Training Notes Zen 2.3

White Paper High Dynamic Range Imaging

Description. Kingbright

3.2mmx3.6mm FULL-COLOR SURFACE MOUNT LED LAMP. Descriptions. Features. Package Dimensions

LED Tester BTS256-LED

General Imaging System

Kingbright. KAA-3528RGBS-K11-C8-CC 3.5 x 2.8 mm Surface Mount LED Lamp PACKAGE DIMENSIONS

Instructions for the Experiment

Introduction of New Products

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Transcription:

Westboro Photonics 1505 Carling Ave, Suite 301 Ottawa, ON K1V 3L7 Wphotonics.com WP640 Imaging Colorimeter Backlit Graphics Panel Analysis Issued: May 5, 2014

Table of Contents 1.0 WP600 SERIES IMAGING COLORIMETER... 3 2.0 MEASUREMENT METHOD... 4 3.0 RESULTS... 5 3.1 RGB IMAGE... 5 3.2 LUMINANCE PSEUDO COLOR IMAGE... 5 3.3 TABULAR DATA... 5 3.4 DISTRIBUTION OF AOI S IN CIE 1931 SPACE... 7 3.4.1 All AOI s... 7 3.4.2 Symbols... 7 3.4.3 Temerature Dial (Blue)... 8 3.4.4 Temerature Dial (Red)... 8 4.0 ANALYSIS... 9 4.1 THRESHOLDING AND EROSION... 9 4.2 SAMPLE EVALUATIONS... 10 Westboro Photonics Page 2

1.0 WP600 Series Imaging Colorimeter The WP600 series colorimeters are Peltier-cooled and stabilized, providing optimal performance and resolution to characterize backlit graphics panels for color and luminance. Unfiltered Light Beam V λ Filtered Light Beam Filtered Image Lens CCD Unfiltered Scene Z X red X blue Rotating Filterwheel The precise matching of the CIE tristimulus filters ensures accurate luminance and chromaticity measurements. Electronic bracketing in Photometrica ensures that an optimal set of exposures are used to measure each point in a scene, even one requiring a high dynamic range exceeding 100,000:1. Photometrica software is included with the WP600 series imaging colorimeter providing users the most productive software environment for simple or in depth analysis. All acquisition and analysis functions of the software can be efficiently automated using the built-in scripting methods, or with the optional Software Development Kit (SDK). Key Features and Benefits: Up to 9MP resolution available Powerful and highly customizable user interface (custom development available) Thermoelectrically cooled CCD Sensor High sensitivity and stability Wide range of lens options available Smallest footprint available for an imaging colorimeter Automation friendly Software Development Kit available Westboro Photonics Page 3

2.0 Measurement Method Sample Details: Sample No. Description Date Analyzed 1 Automotive Panel October 24, 2013 Hardware configuration and setup: A WP640 (S/N 6400113001, demonstrator) with 50mm lens was mounted to a stage on a manual rail system. The sample was placed on a level stage and the measurement area was aligned using the image preview feature of the Photometrica software. The precise position of the AOI s on the surface of the sample was not tracked or tightly controlled. All measurements were performed in a dark room. Westboro Photonics Page 4

3.0 Results The results below are generated using the character refinement tool in Photometrica. After capture, the software can be configured to automatically locate all graphics within the field of view and report their optical quantities in the AOI summary table. More traditional spot meter measurement can also be performed. 3.1 RGB Image 3.2 Luminance Pseudo Color Image 3.3 Tabular Data All data of interest is summarized in the AOI table. The table layout and content are fully configurable with standard spreadsheet functions built in (sorting, etc.). Any column can include a Pass/Fail scheme where the values are displayed in red if they are out of spec. Custom columns with more complex pass/fail scenarios can also be created (such as color and luminance PF below). Westboro Photonics Page 5

Name Luminance cd/m² x y Dominant Wavelength nm Color PF Luminance PF 1 2.533 0.1962 0.2247 480.6 Fail Fail 2 5.031 0.2063 0.2489 482.6 Pass Pass 3 5.906 0.2063 0.2478 482.5 Pass Pass 4 5.312 0.2065 0.249 482.6 Pass Pass 5 5.084 0.2056 0.2474 482.5 Pass Pass 6 5.485 0.2063 0.2487 482.6 Pass Pass 7 5.352 0.2051 0.2479 482.6 Pass Pass 8 6.131 0.2043 0.2461 482.4 Pass Pass 9 2.548 0.1968 0.2275 480.9 Fail Fail 10 4.658 0.2117 0.2557 483 Pass Fail 11 4.004 0.2128 0.26 483.4 Pass Fail 12 6.332 0.2059 0.2476 482.5 Pass Pass 13 6.462 0.2068 0.2488 482.5 Pass Pass 14 5.746 0.2059 0.2476 482.5 Pass Pass 15 5.19 0.2044 0.2488 482.7 Pass Pass 16 6.673 0.2065 0.2478 482.4 Pass Pass 17 5.273 0.2052 0.2471 482.5 Pass Pass 18 6.604 0.2041 0.2471 482.6 Pass Pass 19 6.61 0.2043 0.2447 482.3 Pass Pass 20 5.879 0.2073 0.2502 482.7 Pass Pass 21 5.032 0.1503 0.05034 462.5 Fail Pass 22 8.167 0.7176 0.2815 639.6 Fail Pass 23 5.059 0.2076 0.253 483 Pass Pass 24 4.785 0.2076 0.2535 483.1 Pass Fail 25 4.893 0.2083 0.2524 482.9 Pass Fail 26 4.674 0.2061 0.2456 482.2 Pass Fail 27 5.461 0.2049 0.2459 482.3 Pass Pass 28 5.445 0.2048 0.2459 482.4 Pass Pass 29 5.416 0.2038 0.2433 482.1 Pass Pass 31 4.62 0.2059 0.2438 482 Pass Fail 32 4.664 0.2044 0.2453 482.3 Pass Fail 33 5.059 0.2041 0.2436 482.2 Pass Pass 34 6.123 0.2064 0.252 483 Pass Pass 35 4.973 0.2078 0.2566 483.4 Pass Fail 36 5.643 0.2071 0.2481 482.4 Pass Pass 37 5.358 0.2065 0.2487 482.6 Pass Pass 38 5.978 0.2072 0.2479 482.4 Pass Pass Westboro Photonics Page 6

3.4 Distribution of AOI s in CIE 1931 Space 3.4.1 All AOI s 3.4.2 Symbols Color Region Westboro Photonics Page 7

3.4.3 Temerature_Blue Color Region 3.4.4 Temerature_Red Color Region Westboro Photonics Page 8

4.0 Analysis 4.1 Thresholding and Erosion When measuring graphics, it is important to maintain a minimum number of pixels across a stroke to accurately and repeatedly measure a character. Typically, industry standards will recommend between 6-8 pixel stroke width, though 4 is considered the very minimum. Since edge pixels are not always reliable, thresholding and eroding each character is available for best accuracy and repeatability. The method within Photometrica is quite straightforward and can be fully automated on capture using the available scripting tools: 1. Separate the very edge of the graphic from the background by setting a threshold limit for the glyph edge. 2. Exclude the pixels closest to the edges by eroding the glyph area by one or more pixels An example of the difference in the measured region with and without erosion is offered below. NO EROSION 1 PIXEL EROSION Westboro Photonics Page 9

4.2 Highlight Schemes In addition to offering visual pass/fail cues in the AOI and Evaluation tables, Photometrica can overlay a pass/fail highlight scheme directly over the characters for faster assessment. 4.3 Sample Evaluations The Photometrica software interface has extensive computation ability built into the user interface allowing complex evaluations and analysis to be performed without the need to export the data to external software (excel, etc.) for analysis. Custom columns in the AOI table can be generated based on calculations (uniformity, etc.) of variables. Geometric information (area, centroid, etc.) can also be displayed as required. The visibility of standard or customized columns is easily configured in the AOI column editor. An example of some standard AOI columns exported directly from the software has been provided in the preceding sections. These columns allow complex analysis of each individual AOI within the environment. Further evaluation of the entire measurement environment (not just individual AOI s) can be performed using the evaluations window contained within the software. Using this tool, the column data for AOI s can be summarized or evaluated (i.e. mean luminance of all AOI s, etc.). This utility is particularly useful for production applications where a complex pass/fail algorithm for the entire part can be defined and displayed. Mean Luminance 5.36 Luminance STD 1.02 Percent Pass 94.59 Mean Luminance PF 72.97 Overall Pass_Fail Fail Westboro Photonics Page 10

5.0 Automation Using the native scripting tools in the Photometrica Software, a custom capture sequence can be generated. For example, with a single click of a button the system will measure the DUT, automatically identify all distinct characters, evaluate their luminance and chromaticity according to user-defined methods and report a summary of any regions which are outside of the tolerances. Sample automotive panel screenshot after capture without auto-refinement Panel after applying auto refinement to entire field of view. Each character has been identified (dotted lines around perimeter) and Pass/Fail analysis performed. All in less than 1s. Westboro Photonics Page 11

Various pseudo-color overlays allow users to quickly reveal the average luminance and chromaticity of each character. Optional highlight schemes can also be applied to visually display the pass/fail condition of each character. The pass/fail definition is highly configurable and can include any number of parameters (luminance, chromaticity, uniformity, etc.). Panel with optional highlight scheme applied, performed automatically with refinement. When used in this way, the solution does not require time consuming or expensive setup procedures such as programming or precision positioning of the display. The characters are identified and evaluated regardless of orientation and location without a need for fine alignment of spot meters. Standard spot meter evaluations are also available in the software, where required (see below). Westboro Photonics Page 12