Installation instructions for the Apex and Volt Electric Locksets

Similar documents
Installation Instructions for Trilock Omni BB Twin Pull Handle Version - Suits 35mm to 45mm door thickness

Installing Your Electronic Deadbolt

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Installers guide Deadbolt 02.

Door Hardware Installation Instructions. For Assistance Call:

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Hardware Installation. Do this first:

CL4500 Installation Instructions

Entry Mortise Handleset

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Tools Required. * When installing on a fire door, please see instructions below. *

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Installation Instructions

PMR ELECTRONIC LOCK USER GUIDE

DHAR Test Assessment No. DHAR a.1 Page 1 of 3. The Fire Resistance Performance of E+ Doorsets with nominated variation to the Door lockset

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

Installation Instructions ENGLISH

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Entry Mortise Lock Set Lever to Lever

Before fitting door, check opening size and squareness of timber frame. The door is made smaller to give correct clearance within the frame.

Security Products & Services...That Never Sleep. Sur-Lock. I/O 2000L Family of Exit Control Alarm Locks. Installation Instructions

Installation Instructions II-2/4/5K-0608

Preference Collection and Treatment Console INSTALLATION GUIDE

Tilting Flat Panel Wall Mount Installation Guide

Passage Mortise Lock Set Lever to Lever

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Preference Collection 5543 Central Console INSTALLATION GUIDE

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Preference Collection 5531 Accessory Console I NSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Installation Instructions. Oakmont Folding Doors

Desk/Wall-Mount Rack

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number:

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Assembly Instructions for Model: MF110

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

INSTALLATION INSTRUCTIONS

Bathroom Installation Guide

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Installation Instructions

Installation Instructions For The 8850FL Series Mortise eboss

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

Pet Door Panel Installation Manual

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Assembly Instructions

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

INSTALLATION SUGGESTIONS LEVEL APPLICATION LIMITED WARRANTY

How to Install Custom Real Wood and Faux Wood Blinds

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Keypad Lock Retrofit Kit for Follett REF Undercounter Refrigerator P/N

INSTALLATION INSTRUCTIONS

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

NOVA-EXT Versatile Projector Mount Model: NOVA-EXT

P USHbutton 500 series

SINCE 1922 P UBLICATION N O

Preference Slimline 5536 Utility Console

INSTALLATION INSTRUCTIONS

SERIES. Installation Instructions

13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME

Installing flat panels on the MPL15 wall mount

Installation and Assembly: Full Service Video Wall Mount

1 Door Wall Unit ASSEMBLY GUIDE. Page 1 of 7 14/04/2009 Revision 3. WARNING: Contains small parts, keep out of reach of children.

6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME SPIRIT/LASER LEVEL TO LEVEL THE UNIT

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

4S, 5S, 5A, 6S, 6A, 8S, 9S, 10S, 10A, 26S, 29S, 35S, 35A, 36S,

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

RESIDENTIAL MOTORIZED STORAGE UNIT

INSTALLATION INSTRUCTION

compile system INSTALLATION GUIDE Updated January 2019

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

ArchiTech by Networx

INSTALLATION INSTRUCTIONS

Rim-Lock Door Set Installation Instructions

OWNER'S MANUAL. Please Do Not Return This Product To The Store!

KNEEWALL APPLICATION

TOOLS REQUIRED: HARDWARE INCLUDED: 13MM FLAT WRENCH FOR LEVELING THE STRUCTURE RATCHET WITH 5MM HEX BIT FOR CORNER SCREWS ON TOP TRAVERSE BEAMS

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

Locking Pet Door GPA Product Manual

Congratulations! You are now on your way to enriching your life with!

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

ApexDesk Assembly Guide

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Please Do Not Return This Product To The Store!

TIP FOR GETTING STARTED

Transcription:

Please refer to G+ Lockset Installation Manual for Instructions on how to use this template Paper size A3. These dimensions are for reference only to ensure that scale is correct. Power transfer unit heights FIT HERE ON DOOR EDGE Latch height Installation Template for Door Face Use for Battery and Electric Locksets LATCH BACKSET 60MM CENTRELINE BACKSET 60MM Installation Template for Door Frame G+ ACCESS SYSTEM Hole drilling sequence as per instructions G+ ACCESS SYSTEM Installation Template for Door Frame Please refer to G+ Lockset Installation Manual for Instructions on how to use this template Paper size A4. These dimensions are for reference only to ensure that scale is correct. Installation Template for Door Face Please refer to G+ Lockset Installation Use for Battery and Electric Locksets Manual for Instructions on how to use this template Paper size A3. These dimensions are for reference only to ensure that scale is correct. Power transfer unit heights FIT HERE ON DOOR EDGE BACKSET 60MM LATCH Latch height CENTRELINE BACKSET 60MM G+ ACCESS SYSTEM Hole drilling sequence as per instructions G+ ACCESS SYSTEM G+ LOCKSET: electric Installation instructions for the Apex and Volt Electric Locksets What s IN your G+ LOCKSET BOX? FOLD HERE FOLD HERE G+ LOCKSET APEX CAUTION FOLD HERE FOLD HERE G+ LOCKSET VOLT CAUTION A SCREW KIT A C B SCREW KIT B D SCREW KIT C SCREW KIT D Power Transfer Unit height G+ LOCKSET ELECTRIC G+ LOCKSET ELECTRIC Lever height 75mm APEX DOOR TEMPLATE OR VOLT DOOR TEMPLATE Strike height 1 X G+ LOCKSET FRAME TEMPLATE: ELECTRIC NOTE: Carefully follow these instructions when installing as the process differs from other Gainsborough products. Do not overtighten screws. Use of power driver is not recommended. Screws to be tightened to a recommended 2.5Nm torque. Fully remove the G+ Lockset prior to painting the door to avoid harming the product s finish.

Task 1 1 NOTE: The door furniture faceplate levers are supplied in a neutral position. These need to be handed before installation. Hold faceplate up to the door making sure that the correct faceplate is used. i.e. outside faceplate to outside door face. (The outside faceplate is the one with the sliding cover). Turn the lever in the required direction until it clicks into place. Do this for both the outside and inside faceplates. If rehanding is required, insert a flat blade screwdriver under handing plate and twist. Rotate lever towards top of the faceplate and remove screwdriver. Continue to rotate lever for 180 until it clicks into place. 2 NOTE: If the Door Frame has previously been prepared, then go straight to Step 4. (i.e. if there are 2 holes in the door frame) Door lever height mark Position and hold the inside G+ Lockset onto the door face to determine the most suitable height of the lock (this height will vary depending on the door style). Carefully make a mark on the door frame at the same height as the door lever. Remove the G+ Lockset. 3 Power transfer unit heights Lever height marking Strike heights 1/2 door thickness 1/2 door thickness Position the template supplied (see packaging) on the door frame so that the lever height centreline aligns with the lever height mark you made in the previous step. Firmly hold the template and mark the 2 Power Transfer Unit heights (top markings) and the 2 Strike heights (bottom markings) on the frame. Remove the template and measure the door thickness. Divide this size in half and measure this size from the jam. (Take note of any weather strips that may be fitted to the door jam). Mark this position on the 2 Power Transfer Unit markings and the 2 Strike markings. (Diagram 3) Drill the 2 top holes diameter 1 inch through the frame. Drill the 2 bottom holes diameter 1 inch by 20mm deep (or through if the frame thickness is near this size). Chisel wood to join the 2 top holes (power transfer unit holes). Chisel wood to join the 2 bottom holes (strike holes).

4 Mark and chisel a recess of 4mm for the Power Transfer Unit faceplate. (So that the Power Transfer Unit faceplate is flush with frame edge face). Use the Power Transfer Unit as a template. Mark and chisel a recess of 1.5mm for the Strike. (So that the Strike is flush with frame edge face). Use the Strike as a template. 4mm recess for Power Transfer Unit faceplate 1.5mm recess for the Strike 5 Power point existing or an electrician to install Cable from In-line Power Unit in door frame cavity In-line Power Unit Connect the In-line Power Unit to the Power Point. If there isn t a power point available, then a qualified electrician must be used to install one. The power point can be located in the ceiling as shown in the diagram above. Other possible locations for the In-line Power Unit could include: Under the floor Behind a panel in the wall. Locate the wire from the In-line Power Unit. This will be in the door frame cavity. Pull the end of the wire out through the top hole in the door frame. 6 In-line Power Unit wire Make sure the connectors are pushed together Connect the Power Transfer Unit to the wire from the In-line Power Unit. Insert the Power Transfer Unit into the door frame. As you do this, carefully guide the excess wire back into the door frame cavity. Fix using 2 black wood screws from KIT D. NOTE: Do not over tighten these screws. Do not use power tools. Power Transfer Unit installed in door frame Power Transfer Unit to In-line Power Unit connector Insert the strike and fix using 2 wood screws from KIT A.

Task 2 7 CAUTION: The door drilling templates are different for the G+ Volt and the G+ Apex style locksets. Please ensure that the correct template is used. The template is clearly marked VOLT or APEX. Fold template where indicated (make sure the correct template is used). Strike Template in middle of Strike Battery Box height marking Latch height marking 1/2 door thickness 1/2 door thickness Position template on door edge with the template on the INSIDE door face. Close the door while holding template to door face. Line up the latch centreline on the template with the MIDDLE of the strike on the door frame. Firmly hold template and mark on door face the hole centre points. Without moving the template, open the door and mark latch height and Battery Box height on door edge. Remove template and measure door thickness. Divide this size in half and mark centre of door on Battery Box height and latch height markings. 8 A Drill 1 inch hole 85mm deep in 3 places on door edge. NOTE: It is important to drill holes squarely. A B C D Chisel wood to join the 2 Battery Box holes. B Drill door face holes in 7 places, drilling from both sides of the door. C Drill pilot holes for larger holes in 3 places (suggested size 3mm), drilling from both side of the door. Enlarge the 3 pilot holes to, drilling from both sides of the door. D Mark and chisel a recess of 4mm for the Battery Box faceplate. (So that Battery Box faceplate is flush with the door edge). Use the Battery Box as a template. Mark and chisel a recess of 4mm for the latch faceplate. (So that the latch faceplate is flush with frame the door edge). Use the latch as a template. 9 Insert the latch making sure that the tapered (bevelled) side of the latch faces towards the door frame when the door is open. Fix using 2 wood screws from KIT A. Insert the Battery Box. The wires exiting the Battery Box should face towards the outside of the door. Wrap the wires over the top of the Battery Box and pass the connector through the top hole on the inside door face. (The wires will now be coming through to the inside). See Step 11. Fix using 2 black wood screws from KIT D. NOTE: Do not over tighten these screws. Do not use power tools.

10 Refer to G+ Lockset user guide before changing these switches. If there is more than 1 G+ Lockset in the house, switch A might need to be changed. Switch A Shift selection Switch B Revert to privacy 11 Insert 4 rechargeable NiMH AAA batteries making sure correct polarity (+ and -) orientation. Assemble the Battery Box transmitter and fix using 2 black wood screws from KIT D. NOTE: Do not over tighten these screws. Do not use power tools. IMPORTANT NOTICE: NiMH batteries MUST be used in this product. Failure to do so could result in severe damage and will void any warranties. Task 3 12 Install 6 posts from KIT B onto the outside faceplate. Tighten posts using pliers.

Task 3 13 NOTE: The mounting plate must first be removed from the inside faceplate. Insert key and turn clockwise. Remove the mounting plate. The key can now be turned back to the vertical position and removed. Turn key clockwise 14 Inside door face The rotor is pre-installed onto the mounting plate. The rotor must be positioned such that one notch faces upwards, and the other notch faces towards to latch side (door opening). Mount and hold the outside faceplate onto the outside door face. Assemble the mounting plate to the outside face plate. Make sure the connector wires pass through the large rectangular hole in the mounting plate and that the spindle engages the outside lever. Rotor Fit 2 mounting screws from KIT B and tighten. NOTE: If KIT B contains 2 length of screws then use the following guide: For doors up to 40mm thick use the 2 short screws. For doors 40mm and over use the 2 long screws. 15 Make sure the connectors are pushed together Insert key into the inside faceplate and turn clockwise. Leave key in this position. Assemble the connector from the Battery Box with the connector on the faceplate. Make sure they are firmly pressed together. NOTE: Do not let go of the faceplate or allow the faceplate to hang from the wires. Turn key clockwise Hold the faceplate flush against the door face making sure that wires from the Battery Box are not trapped. The key can now be turned back to the vertical position and removed. The faceplate is now temporarily secured and will not fall if let go. Fit 4 mounting screws from KIT C and tighten.

Task 4 16 Installing the batteries into the G+ Keys. Remove the battery compartment cover by twisting anti-clockwise and lifting off. Insert two batteries + side up (as per diagram above). Replace the battery compartment cover and twist clockwise to lock. 17 Press these two buttons together Teach mode activation via paper clip Perform the following steps to program G+ Keys to the lockset. 1 The teach button is accessed through the small hole in the face plate of the Battery Box Transmitter (on the door). To place the lockset into teach mode, press and hold the teach button with a paper clip, or similar, until the lockset emits a teach confirmation sound (1 long; 2 short beeps) then release the teach button. This should take approximately 3 seconds. NOTE: You have 10 seconds to perform steps 2 and 3 before teach mode times out and reverts back to any previously taught G+ Keys. 2 On the first G+ Key to be taught, press buttons 4 & 5 (diagram 17). These buttons must be pressed simultaneously until the lockset emits a single beep. 3 Repeat step 2 for each G+ Key to be taught. Each additional G+ Key must be added within the 10 seconds otherwise the lockset will time out and replace any previously taught G+ Keys with the keys taught in this session. 4 Once the last G+ Key has been taught, wait for the lockset to emit the teach mode session finish beeps, (1 long; 1 short; 1 long). NOTE: If no G+ Keys are taught during the teach session, the lockset will revert back to any previously taught G+ Keys. For doors up to 40mm thick use 2 short screws. For doors 40mm and over use 2 long screws.

G+ ACCESS SYSTEM Gainsborough Hardware Industries Limited Hotline 13 14 18 Head Office 31 33 Alfred Street Blackburn, VIC 3130 PO Box 330, Blackburn VIC Telephone 03 9877 1555 Admin & Export Fax +61 (0)3 9894 1599 Email sales@gainsboroughhardware.com.au www.gainsboroughhardware.com.au NSW Suite 1B, 126 Taren Point Rd Taren Point NSW 2229 T 02 9524 4855 F 02 9524 5670 SA 31 Lansdowne Tce Vale Park SA 5081 T 03 9877 1555 F 03 9894 1599 QLD 433 Logan Rd Stones Corner Qld 4120 T 07 3394 8323 F 07 3847 5444 TAS PO Box 330 Blackburn VIC 3130 T 03 9877 1555 F 03 9894 1599 WA 12 Juna Drv Malaga WA 6945 T 08 9209 2511 F 08 9209 2611 NTH QLD Unit 1/ 17 Camuglia St Mt Louisa QLD 4814 T 07 4774 5124 F 07 4774 5292 VIC 31 33 Alfred St Blackburn VIC 3130 T 03 9877 1555 F 03 9894 1599 NZ Unit 5E 269A Mt Smart Rd Penrose Auckland T +64 9 525 6970 F +64 9 525 6982 This document contains general information only and is in no way to be regarded as a complete and comprehensive guide. Gainsborough Hardware Industries Limited ACN 004 792 269 (Gainsborough Hardware) makes no representation about the content and suitability of this information for any purpose. You should exercise your own independent skill and judgement before you rely on this document and obtain appropriate advice relevant to your particular circumstances. The information is provided as is and without express or implied warranty. Gainsborough Hardware disclaims all warranties, including all implied warranties as to merchantability or fitness. In no event shall Gainsborough Hardware be liable for any direct, special, indirect or consequential damages or any damages whatsoever resulting from loss of income or profits, whether in an action of contract, negligence or other tortious action, arising in connection with the use or performance of the information in this document. The availability of products set out in this document is not guaranteed and Gainsborough Hardware reserves the right to alter, amend or delete any part of this document without prior notice. This disclaimer is subject to any contrary legislative provisions. Take care! electricity kills. Switches, power outlets and other fixed wire products must be installed by a licensed electrical contractor or similarly qualified person. EAS1DOC01CL1 DWGAI0023 PV1.3.12