SA-027HQ 365-Day Annual Timer

Similar documents
MANUAL. PT Series 365 Day Annual Timer. Tel:

SD-996C-NUQ. Universal Door Strike. Manual

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment

VPD (Video/Power/Data) Combiners

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

ProScale. Compact LCD Readout. Installation & Operation

ProScale Compact LCD Readout. Operation. Firmware version C 2.xxx and higher

LIGHTING CONTROL PANEL

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

V22 Thermostat N515/R00( )

Series 3000 Model R-107A

Firmware Version d & higher Installation & Operation

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

Megacode Receiver. Multi-Frequency Four Channel Receiver 10:05:12 STD MON OFF OFF OFF OFF. Doc # _00 Part # Released 15/05/14

Digital Electronic Thermostat With RF

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

BATTERY SENSOR. User Manual. Manual Version: BMS

Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions

To Purchase This Item, Visit BMI Gaming

AURATON 2020 AURATON 2020 TX RX Plus

Firmware Version d & higher Installation & Operation

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

EL71 - Single Channel & EL72 - Two Channel Electronic Time Controls General Instructions

Operator s Manual for Your Wireless Leash Guidance Trainer Series

Using the USB Output Port to Charge a Device

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

Sentry Digital Timers

MODEL 8080PR3 Released on 11th Mar 2013

SSR-150xxx-40VL-12P-xC-xxxCS

12B/18 MultiMeter Instruction Sheet

User s Guide Instructions for Installation and Operation

INSTALLATION INSTRUCTIONS

BOOMERANG PAGING SYSTEM (RCL T800) Manual

EVT-AH16-VT2Q. 1U Rack-Mount 16-Channel Active Balun Hub. Manual

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

Indoor Contact Input Photosensor

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

User s Guide Instructions for Installation and Operation

Quick Start Guide. PFD Six Meal Feeder. Please read this entire guide before beginning. For the full Product Manual, visit petsafe.com.

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

SYSTEM OPERATING CONTROLS

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

INSTALLATION INSTRUCTIONS

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

User Manual OFF ON IN OUT ALARM RESET AURATON RTH software ver. F0F

Taurus CP-300 Single Pump

TR1000 IRRIGATION MANUAL

Digi-Fence. User Manual (all models) For All Models with Digital Readout Firmware version d & Higher

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

AMANO. Electronic Calculating Time Recorder. Setup and Operations Manual

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

INSTALLATION AND SETUP GUIDE

Keychain Radio Remote Control System

RUSH G1 MECHANICAL KEYBOARD PRODUCT MANUAL V.14

Talk & Listen Systems

Digi-Fence. User Manual for: Digi-Fence (all models) Digital Readout Firmware version d & Higher

S-Series Digital Thermostat

User Instructions For TopTronic RS-10

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

JAMP-630HC14-ULP. Installation and Operation Instructions. ROKKER XXRP 630w Amplifier Kit For Harley Ultra/Ultra Ltd.

LPU-2127 User Manual

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Installation Instructions

WIRELESS BLUETOOTH AUDIO TO ANY CAR RADIO MAKE THE CONNECTION

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

TARGETuner Antenna Management System for Screwdriver Antennas

UR200SI / UR200WE ENGLISH

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

T-L 810-T TRANSMITTER GUIDE

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

PTT- Z or PTT-U PUSH-TO-TALK Specification

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

AMP SELECTOR Owner s Manual

PA Watt Compact Two Zone Amplifier to Drive up to 60 Paging Speakers. 60 Watt / 2 Zone Power Amplifier. Features. Applications.

LogiTALKER OWNER S MANUAL. Voice Keyer. Idiom Press. PO Box 1015, Merlin, OR USA

Digi-Stop. User Manual for: Digi-Stop. Digital Readout Firmware version d & Higher

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

V-9927A DIGITAL MULTI-TONE GENERATOR

f i r e - p a r t s. c o m

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

CDT. Service and Installation Manual. Manual Revision Oct 2014

Transcription:

SA-027HQ 365-Day Annual Timer Manual Two N.O. or N.C. Form C relays, 10A@14VDC Each relay can be programmed for 50 events, for a total of 100 individual programmable events 10 Programmable holidays The 100 programmable events can be set weekly, daily, or hourly, over the course of an entire year Password protection can be turned ON or OFF One egress input per relay (2 total)

Table of Contents: Introduction... 2 Features... 2 Specifications... 3 Parts List... 3 Overview... 3 Installation... 3 Function Buttons... 3 Relay Options... 4 Programming Key... 4 Programming Notes... 4 Setting Time and Date... 5 Programming Events... 5 Programming Worksheet... 6-7 Programming Holidays...8 Clearing Memory...8 Setting Block Programming and Time Settings.8 Programming Password...9 Using Password Protection...9 Password Reset...9 Programming Menu Flowchart...10 Wiring Diagram...11 Using 2 Relays in Tandem...11 Wireless Operation...12 Warranty...12 Introduction: The ENFORCER SA-027HQ Annual Timer can be programmed to operate two relays 24 hours a day, over the course of an entire year. These relays can be used to control devices in many applications such as security, access control, lighting, and environmental control. The two Form C relays can each be programmed to operate in shunt or momentary mode for up to 50 unique events. Each event can be programmed on a weekly or daily schedule. Block programming allows events to be repeated on consecutive days. 10 Programmable holidays disable the timer for a single day, or for the same day every year. Features: Two N.O. or N.C. Form C relays 10A@14VDC. Each relay can be programmed for 50 events, for a total of 100 individual programmable events. The 100 programmable events can be set weekly, daily, or hourly, over the course of an entire year. Password protection can be turned ON or OFF. One egress input per relay (2 total). Block programming allows events to be repeated on consecutive days. First-person-in function interrupts the normal operation of the annual timer. Event outputs can be programmed disable, ON, OFF, shunt, or momentary (1~99 seconds). 10 Programmable holidays. Can be programmed for password protection. Tandem mode allows both relays to operate simultaneously. EEPROM Memory for safe data protection in case of power failure. Built-in clock backup battery. Built-in backup battery charger for external backup battery use. Compensates for leap years. Can be set for Standard or Daylight Saving Time. Alphanumeric backlit LCD display for easy programming. 2 SECO-LARM U.S.A., Inc.

Specifications: Input voltage 12~24 VDC/VAC Number of relays 2 Relay rating 10A@14VDC Current draw 100mA Number of prog. events 50 for each relay, 100 total Blue LED ON Power is ON OFF Power is OFF Number of prog. holidays 10 Battery charging current 90mA Security code 4-digits, numeric, ON/OFF Overview: SA-027HQ Annual Timer Parts List: 1x 365-Day Timer 1x Manual 2x Screws 2x Back-up battery wires Power LED Set button Enter button LCD display Up button Down button Installation: 1. Find a location for the SA-027HQ where the LCD display is easily seen and the buttons can be pressed. Mark that location. 2. Open the case and connect the wires. 3. Connect a 12/24 VDC/VAC power supply to the power input terminals marked (+) and (-). 4. Connect the battery backup to the backup battery input terminals marked (+) and (-). NOTE: For the best backup battery charging results, the power input should not be lower than 17VDC or 12VAC. 5. Remove the paper battery protector from the onboard clock backup battery. NOTE: The paper protector prevents the battery from being drained during product shipment. If the protector is not removed, the onboard clock backup battery will fail to function. 6. Connect the devices that are being controlled to the outputs of one or two relays. NOTE: If using a DC-powered electric/electromagnetic lock, connect a 1N4004 diode in parallel with the power supply and as close to the lock as possible. This absorbs possible interference and prevents operation of the lock from damaging the timer. Not required for AC-powered locks. 7. Close the case and mount the unit. Function Buttons The SA-027HQ has 4 function buttons that control the programming features. Table 1: Function Buttons SET Enters the main menu, backs out of a submenu ENTER Enters a submenu, accepts the current value above the cursor UP Changes the menu selection or the value above the cursor DOWN Changes the menu selection or the value above the cursor SECO-LARM U.S.A., Inc 3

Relay Options: 1. Press the UP or DOWN button while the main screen is on to show the relay status screen. a. Press and hold the UP button for 3 seconds to toggle relay 1. b. Press and hold the DOWN button for 3 seconds to toggle relay 2. 2. See Table 2 below for different event modes available under Event programming Table 2: Event Modes Disable ON OFF Pulse Programming Key: Programming Notes: Disables the event (factory default) Turns the relay ON Turns the relay OFF Activates the relay for 1~99 secs. BK Block Coding HOL Holiday ON Relay will switch on MO Monday OFF Relay will switch off TU Tuesday DIS Relay will be disabled WE Wednesday PL Relay will pulse for a # of seconds TH Thursday DS Daylight Saving Time* FR Friday ST Standard Time SA Saturday R1 Relay 1 SU Sunday R2 Relay 2 For an explanation of Daylight Saving Time, please see page 8. A convenient feature of the SA-027HQ Annual Timer is the ability to program it before installation. The EEPROM memory stores and protects programming instructions. Programming the SA-027HQ is easier and faster if you know exactly how you want to use the Annual Timer, as well as functions it will perform. 1. Following the programming instructions in order will make installation easier. 2. Determine which relays will operate the devices that are being controlled. 3. Determine if two relays will be used in tandem. 4. Determine if Daylight Saving Time or Standard Time will be used. For a full explanation, see Setting Block Programming and Time Settings on page 8. 5. Using a separate piece of paper, write down the following: a. The days to be block coded. For example: Monday through Friday or Sunday and Monday. b. All the events you want to program, as well as their duration (up to 50 per relay). c. Any holidays you wish to program to override the programmed events (up to 10). 6. Decide whether you will use a password or not, and what the password will be. For password operation, see page 9. 7. To reset the password, see Password Reset on page 9. 4 SECO-LARM U.S.A., Inc.

Setting the Time and Date: 1. To set the time and date, press the SET button on the SA-027HQ until ENTER TO SET TIME" appears on-screen. Press the ENTER button to confirm the programming selection. S E T T I M E 0 1 /01/01 S U 0 1 : 0 1 05/ 01/01 S U 0 1 : 0 1 05/22/01 S U 0 1 : 0 1 05/22/09 S U 0 1 : 0 1 05/22/09 FR 0 1 : 0 1 05/22/09 F R 16: 01 05/22/09 FR 16: 20 2. Press the UP or DOWN button to enter the correct month, date, and year. 3. Press the UP or DOWN button to enter the correct day of the week, hour, and minute. 4. Press the ENTER button to confirm a selection, or press the SET button to go back to the previous selection. NOTE: Time is shown using the 24-hour format. For example, 5:30 AM is shown as 05:30, while 5:30 PM is shown as 17:30. Programming Events: 1. To set events, press the SET button on the SA-027HQ until ENTER TO SET EVNT appears on-screen. Press the ENTER button to confirm the programming selection. S E T E V N T 01 R 1 D I S S U 0 0 : 0 0 0 1 R 1 P L 3 M O 0 7 : 30 2. Press the UP or DOWN button to enter the event number, the relay number and how the relay will operate, and the day and time the event is scheduled. Refer to Programming Key on page 4. 3. Below are some examples of how each event can be programmed: 0 1 R 1 P L 4 5 W E 1 2 : 4 5 2 9 R 2 O N B K 0 7 : 5 5 30 R 2 O F F B K 1 7 : 0 5 5 0 R 1 D I S S U 0 8 : 0 0 Event #1, Relay #1 Pulse 45 secs Wednesday only Occurs at 12:45 Event #29, Relay #2 Relay ON Block programming Occurs at 07:55 Event #30, Relay #2 Relay OFF Block programming Occurs at 17:05 Event #50, Relay #1 No Relay Output Sunday only Occurs at 08:00 SECO-LARM U.S.A., Inc 5

6 SECO-LARM U.S.A., Inc.

SECO-LARM U.S.A., Inc 7

Programming Holidays: 1. To set holidays for suspending normal operation of the timer, press the SET button on the SA-027HQ until ENTER TO SET HOL appears on screen. Press the ENTER button to confirm the programming selection. S E T H O L # 01 H O L 01/01/01 # 0 5 H O L 07/04/09 2. Press the UP and DOWN buttons to enter the holiday number and the date the timer will suspend normal operation. Press the ENTER button to confirm the programming selection. 3. To set a holiday for suspending normal operation of the timer every year, set the year to XX. Note: Please be aware that most holidays occur on different days of the week in different years. For example, if New Year s Day occurs on Sunday, January 1 st, a workplace will be typically closed on Monday, January 2nd. Note this when programming a holiday with the XX option. Clearing the Memory: 1. To clear the memory, press the SET button on the SA-027HQ until ENTER TO CLR MEMO appears on-screen. Press the ENTER button to confirm the programming selection. C L R M E M O C L E A R M E M O R Y? P R E S S U P T O C L E A R 2. Using the function buttons, press the ENTER button to confirm you want to clear the memory. 3. Using the function buttons, press the UP button to clear the memory. Setting Block Programming and Time Settings: 1. To set block events, press the SET button on the SA-027HQ until ENTER TO SET BK appears on screen. S E T BK BK=MO/ S U T I M E = D S B K = M O / FR T I M E = D S 2. Pressing the ENTER button will confirm the programming selection. 3. Using the function buttons, press UP or DOWN to enter in the first day of consecutive days you want an event to repeat, press the ENTER button to confirm the programming selection. 4. Using the function buttons, press UP or DOWN to enter in the last day of consecutive days you want an event to repeat. Press the ENTER button to confirm the programming selection. 5. Using the function buttons, press UP or DOWN to switch between Daylight Saving Time (DS) or Standard Time (ST) format. For more information see the note below. B K = M O / F R T I M E = DS B K = M O / F R T I M E = ST Note: The SA-027HQ follows U.S. Daylight Saving Time (DST) standards. DST begins at 2:00 a.m. local time (add one hour) on the 2 nd Sunday of March and switches back to Standard Time at 2:00 a.m. local time (subtract one hour) on the 1 st Sunday in November. 8 SECO-LARM U.S.A., Inc.

Programming Password: 1. To set the password, press the SET button on the SA-027HQ until ENTER TO SET CODE appears on-screen. Press the ENTER button to confirm the programming selection. S E T C O D E Y E S / N O C H N G Y /N E N T E R O L D C O D E 0000 THE FACTORY DEFAULT PASSWORD IS 0000. 2. Using the UP and DOWN buttons, select YES or NO. Press the ENTER button to confirm the selection. A confirmation screen will appear. Select Y to set the password or N to go back. 3. Using the UP and DOWN buttons, enter in the password you are changing. E N T E R N E W C O D E 7291 N E W C O D E A C C E P T? 4. If the password is correct, use the UP and DOWN buttons to set a new password. 5. After entering the new password, press the ENTER button to accept the new password. Using Password Protection: 1. If the password protection is set, the password must be entered every time programming mode is entered. C O R R E C T 0000 C O R R E C T Password Reset: 1. Disconnect power from the SA-027HQ. If installed, remove the back-up batteries. 2. Within 30 seconds after power is reconnected, press all four function buttons (UP, DOWN, SET, and ENTER) at the same time for approximately 5 seconds. If the buttons are not pressed within 30 seconds, then the SA-027HQ will be unable to reset the password. 3. After the four function buttons are pressed for 5 seconds, PASSWORD RESET will appear for 1 second, followed by NEW PSWD 0000 for 1 second, and then ENTER PASSWORD. R E S E T N E W P S W D 0000 4. The password has now been restored to the factory default setting 0000. 5. Within 1 min. after ENTER PASSWORD is displayed, enter the new password. If no password is entered, the SA-027HQ will exit password programming mode automatically. 6. No other programming changes have been reset, only the password. 7. For added security, it is recommended to change the password immediately. OR E R R O R E N T E R SECO-LARM U.S.A., Inc 9

Programming Menu Flowchart: 01/01/01 S U 0 1 : 0 1 Only if the password is enabled. See Password Operation on page 9. E N T E R S E T T I M E S E T E V N T S E T H O L C L R M E M O S E T BK S E T C O D E 10 SECO-LARM U.S.A., Inc.

Using 2 Relays in Tandem: The SA-027HQ can be configured so that both relays operate at the same time. By setting the jumper to the ON position, the timer will output on both relays whenever an event is programmed for either Relay #1 or Relay #2 (factory default is set to OFF). Tandem Jumper marked JP01: JP01 ON Tandem output ON OFF OFF No tandem output Wiring Diagram: IMPORTANT: When connecting to a backup battery, the input voltage needs to be 17~24VDC or 12~24VAC ONLY. An unregulated 12VDC adapter (ST-1212-U0.5A) is acceptable. 12~24 VAC/VDC Connect to input power Backup battery power input First-person-in #1 Relay output #1 N.O. COM N.C. First-person-in #2 Connect to 12VDC backup battery Connect to N.O. ground switch* Connect to device #1 Connect to N.O. ground switch* Relay output #2 N.O. COM N.C. Connect to device #2 Egress input #1 Egress input #2 Connect to N.O. ground switch * When the optional N.O. switch is activated, the first-person-in function suspends the operation of the SA-027HQ annual timer. If a relay is turned on before the first-person-in feature is activated, the relay will remain on until the first-person-in feature is deactivated. Once deactivated by turning the switch off, the timer will turn on the last programmed function prior to the first-person-in activation. SECO-LARM U.S.A., Inc 11

Sample Application: 12~24 VAC/VDC Power supply Backup battery power input Backup battery First-person-in #1 Relay output #1 N.O. COM N.C. First-person-in #2 Relay output #2 N.O. COM N.C. Egress input #1 Egress input #2 PUSH TO EXIT Gate operator (A gate operator connected to the lock relay output is triggered and opens a gate) Bell Request-to-Exit Plate Wireless receiver 2 Wireless transmitter 1 1 A wireless initiate device, such as the SK-919TD1S-UP, is triggered. 2 A wireless receiver, such as the SK-910RBQ receives the signal. The receiver s common terminal is connected to a positive voltage and the normally closed terminal is connected to the SA-025EQ s initiate input. WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else. NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM. SECO-LARM U.S.A., Inc. 16842 Millikan Avenue, Irvine, CA 92606 Website: www.attf.com PITSW1 MiSA-027HQ_1402.docx Order Part# 763-180% 12 SECO-LARM U.S.A., Inc.