Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Similar documents
ICF-1280I Series Quick Installation Guide

The I-2532 CAN to Fiber Converter

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

PROFIBUS HUB REPEATER

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

CM /100/1000BASE-T

I-2533CS series User Manual

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

SFP 4.25G 850nm Multi mode Optical Transceiver

WIRELESS MODBUS GATEWAY WGW410

Document # Rev. C October, GEMINI EXPRESS MULTIPLEXER User s Guide

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

Universal RS232/CMOS to RS422/RS485 Converter

SFP CWDM 1.25G nm Single mode Optical Transceiver

Miniature Synchronous Multipoint Modems

SFP+ 16G 1310nm Single mode Optical Transceiver

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

Contents subject to revision without prior notice.

BO05C13610 SFP 1.25G 1310nm 10KM RoHS Compliant Optical Transceiver

Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

3-FIBMB2 Fiber Optic Interface Module Installation Sheet

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Applicable for the following PLC UV Head Controller model: PLC R

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Since 1987 Developed, Created and Made in Spain NDR6 OPTIC DATA TRANSCEIVER

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

TPP3XGDS0x000E2G 850nm SFP+ Transceiver

CP485-4 User s Manual

SFP CWDM 1G 120km LC datasheet A-GEAR World Wide Manufacturing Product Specification

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

[ tima-datasheet-en v11.1 ]

QUINT-PS AC/24DC/40

4 Channel Contact Closure DIN Fiber Link System

Modicon Quantum 140 NRP /01 Fiber Converter Modules User Guide

QUINT-PS/ 3AC/24DC/10

EX-SFP-1GE-LX-A 1000Base-LX SFP Module 1310nm, 10Km, SMF, LC RoHS6

WARNING Improper operation may result in serious personal injury CAUTION

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

SISNet Distance Extenders

The Price Performance Leader in 100% Compatible Optical Transceivers GBIC-GE-S40K Part Number: GBIC-GE-S40K PRODUCT FEATURES APPLICATIONS

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

HEC-30/35LTA-33TDAA Rev A

RuggedNet GPoE+/Si Unmanaged 4 and 8-Port PoE/PoE+ Switch. User Manual. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949)

GLC-LH-SMD-SO SFP, 1G, 10km, Single Mode, 1310nm, with DOM

LTF8506 SFP+ AOC 10G Ethernet SFP+ Active Optical Cable

10Gb/s DWDM Single-mode SFP+ Transceiver

HEC-45LTN-45PFAS Rev A

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

PRODUCT SPECIFICATION

HEC-35LTA-XXTSAA Rev A

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

Typical Efficiency (2)

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

GLC-SX-MMD-SO SFP, 1G, 550m, Multi Mode, 850nm, with DOM

GC9838-LR - INTELLIGENT HYBRID PLC-RF DIN RAIL MODEM

10/100BASE-TX to 100BASE-FX. Fast Ethernet Media Converter. Quick Installation Guide

CompoNet Gateway Unit for CC-Link

SWT 3000 Teleprotection technical data siemens.com

SFP 1G 150km CWDM (1470~1610) Transceiver datasheet A-GEAR World Wide Manufacturing Product Specification 1. Featur es 2.

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

1550nm 40km SFP+ Transceivers

1.25Gb/s 160km DWDM SFP Transceiver (OP340GD-D ) Hot Pluggable, Duplex LC, 100GHz, DWDM DFB & APD, Single-mode, DDM

SFP+ 10G Transceiver M10GB-SFP-BIDI10

Cisco Smart SFP Network Interface Device

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

1550nm 40km SFP+ Transceiver

z488xx RF Switches/Multiplexers PXI

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

RuggedNet GPoE+/Mi Managed 4 and 8-Port PoE/PoE+ Switch. Quick Start Guide. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949)

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V)

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

4.25Gbps SFP Transceiver

MINI-PS AC/24DC/1.3

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

1300nm Fast Ethernet Transceiverin1x9SC Duplex Package

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

AA E6-A AA E6-A. Features. Up to 1.25Gb/s Data Links. Hot-Pluggable. Duplex LC connector. Up to 10km on 9/125μm SMF

HEC-40LTN-XXPSCA Rev A

FEATURES. Static Current (ma) Baud rate (bps) TD321D485H-E 321RHE k TD521D485H-E 521RHE k

HEC-70LCN-350TDAF Rev B

PDL Base. Radio Modem User's Guide. Revision 0.2 (preliminary) May 1999 Copyright 1999 Pacific Crest Corporation Document M00522

JBUS/MODBUS communication card

Modbus communication module for TCX2: AEX-MOD

CONV232/422 SERIAL DATA CONVERTER

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

2.5Gbps SFP Transceiver

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

SFP+ BIDI Series JB1270-SFP-LC.S20

Transcription:

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Hardware Installation Guide First Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802012800011

Introduction The ICF-1280I series PROFIBUS-to-fiber converters are based on the PROFIBUS DP standard, and are compliant with EN 50170. The converters are mainly used to extend the transmission distance of PROFIBUS devices over optical fiber, and provide redundant transmission. More specifically the ICF-1280I series converts PROFIBUS signals between copper and fiber wires, and extends PROFIBUS transmission up to 4 km (for multi-mode models) or up to 45 km (for single-mode models). In addition, the ICF-1280I series converters have dual fiber ports that can be used to form a ring topology for redundant transmission, and avoid package lost when a fiber path is broken. The ICF-1280I converter also provides 2 kv isolation protection for the PROFIBUS system and dual power inputs to ensure uninterrupted operation. The ICF-1280I series converters are uniquely designed with Remote Fiber Diagnosis that eliminates the need for a fiber optic sensor by using DIP switch adjustments instead. Remote Fiber Diagnosis can detect fiber connections for the overall topology from any individual converter, and determine which side (Tx or Rx) is causing the problem for the converter. Why Convert PROFIBUS to Fiber? Optical fiber communication not only extends the communication distance, but also provides the following advantages: Immunity to electrostatic interference: Fiber is immune to electromagnetic interference and radio frequency interference. It provides a clean communication path and is immune to cross-talk. Insulation: Optical fiber is an insulator interface; the glass fiber eliminates the need for using electric currents as the communication medium. Security: Fiber cannot be tapped by conventional electric means and is very difficult to tap into optically while radio and satellite communication signals can be captured easily for decoding. High reliability and low maintenance: Fiber wires are immune to adverse temperature and moisture conditions. As a result, they do not corrode or lose signals, and are not affected by short circuits, power surges, or static electricity. Auto/Manual Baudrate Settings The ICF-1280I series converters simply convert the signal back and forth between PROFIBUS and fiber at baudrates between 9.6 Kbps to 12 Mbps. Engineers do not need to know the baudrate of the connected PROFIBUS device; the ICF-1280I series converters can automatically detect the baudrate of the PROFIBUS device and apply this baudrate directly. This is an extremely convenient feature. If necessary, baudrates can be set to a fixed value via DIP switches to shorten the baudrate detection period when the system initializes. PROFIBUS Fail Safe Electrical noise may be generated when a PROFIBUS device malfunctions or the serial interface fails, resulting in bus failure. Traditional media converters transmit noise signals through the fiber wire to the other converter. This not only disrupts data communication between the two buses, but will also bring communication across the entire system to a - 2 -

halt. When this occurs, the engineers will not be able to easily locate the failed device because the entire PROFIBUS network is down. To avoid this situation, the ICF-1280I series converter has a mechanism to detect and recognize noise signals. If the bus fails on one side, the noise signal will not propagate through the ICF-1280I converter and affect additional bus segments. In addition, the ICF-1280I converter will also trigger an alarm to provide the location of the failure to the field engineer. Fiber Link Monitoring The ICF-1280I series converter provides a fiber link monitoring function to detect the communication errors on both sides of the fiber connection. When a communication error occurs, a red LED status indicator (P1, P2, or Fault LED) will turn on and the relay alarm will activate. If a fiber abnormality occurs on a remote fiber segment, the Fault LED will flash. Engineers can then use the Fiber Diagnosis function for troubleshooting. Reverse Power Protection The Reverse Power Protection feature protects against accidentally connecting the power cables to the wrong terminal. The converter is designed to detect automatically which power wire is positive and which is negative, and then adjust the power supply accordingly. Remote Fiber Diagnosis Optical fiber cables are often deployed for long distance communication and a fiber optic inspection pen is used by engineers to ensure proper communication quality of the fiber cable. The ICF-1280I series converters eliminate the need for a fiber optic inspection pen by providing a Remote Fiber Diagnosis function that uses DIP switch adjustments. There are two major functions provided by Remote Fiber Diagnosis: (1) determining which side (Tx or Rx) is causing the problem on the converter; (2) examining the fiber connections for the overall topology from any individual converter. Fiber cable abnormalities can be automatically detected and identified by the LED indicator even if it is not adjacent to the converter. Remote Fiber Diagnosis facilitates fiber cable deployment and management, and also significantly shortens troubleshooting time by examining fiber connections for the overall topology from any individual converter. - 3 -

Using Remote Fiber Diagnosis: Set DIP switch SW8 to the ON position on any ICF-1280I converter and see the Ready LED status. A flashing green Ready LED indicates that the Fiber Diagnosis has finished. The Fault LED indicates the location of the fiber connection abnormality. The P1 or P2 LED indicates which side (Tx or Rx) is causing the problem. The Fault LED will shine a steady red to indicate an adjacent fiber connection error, or flash red to indicate a non-adjacent fiber connection error. If there are no fiber connection errors in the entire topology, the related LEDs will shine green or remain OFF. If the fiber connection error is adjacent to the converter, the status will also be indicated by the P1 (Port 1) or P2 (Port 2) LEDs. A flashing red light on P1 (or P2) means that the Rx fiber cable connected to this port is broken. Similarly, a solid red light on P1 (or P2) means that the Tx fiber cable in this port is broken. If the fiber connection error is not adjacent to the converter (i.e., the fiber cables connected to this converter are working properly), the Fault LED will flash red. As a result, you should run Remote Fiber Diagnosis on every other (second) converter in the topology to recursively troubleshoot the problem. Further descriptions and troubleshooting can be found in the Troubleshooting table. Redundant Ring The ICF-1280I series converters can connect PROFIBUS devices in a redundant ring topology. Use the DIP switch to configure all the ICF- 1280I converters to Redundant Ring mode. When a PROFIBUS master transmits a signal from one converter to the PROFIBUS slave devices, this signal will travel to all the converters around the ring until it returns to the original converter and terminate. How to form a redundant ring topology: To form a redundant ring topology, connect the Tx Port (Port 1) on the first ICF-1280I converter to the Rx Port (Port 2) on the following converter. Then, connect the Tx Port (Port 2) on the first ICF-1280I converter to the Rx Port (Port 1) on the preceding converter. Similarly, connect the Rx Port (Port 1) on the first ICF-1280I converter to the Tx Port (Port 2) on the following converter. Then, connect the Rx Port (Port 2) on the first ICF-1280I converter to the Tx Port (Port 1) of the preceding converter. - 4 -

Features Redundant Ring mode for fiber communication backup with zero recovery time Remote Fiber Diagnosis Auto baudrate detection and data speeds up to 12 Mbps PROFIBUS bus fail safe Alarm by relay output Provide 2 kv galvanic isolation Power polarity protection Extend PROFIBUS transmission distance: Up to 45 km with single-mode (ICF-1280I-S models) Up to 4 km with multi-mode (ICF-1280I-M models) Point-to-point, linear (bus), star, and redundant ring topologies Dual power input for redundancy Wide operating temperature from -40 to 75 C (for -T models) Package Checklist Before installing the ICF-1280I converter, verify that the package contains the following items: ICF-1280I PROFIBUS-to-fiber converter Hardware installation guide Warranty card NOTE: Please notify your sales representative if any of the above items are missing or damaged. Mounting Dimensions (Unit: mm) ICF-1280I - 5 -

Top View Front View ATTENTION Electrostatic Discharge Warning! To protect the product from damage due to electrostatic discharge, we recommend wearing a grounding device when handling your ICF-1280I series converters. Mounting The aluminum DIN-rail attachment plate should be fixed onto the back panel of the ICF-1280I converter when you take it out of the box. If you need to reattach the DIN-rail attachment plate to the ICF-1280I converter, make sure the stiff metal spring is situated towards the top, as shown in the figures below. STEP 1: Insert the top of the DIN rail into the slot just below the stiff metal spring. STEP 2: The DIN-rail attachment unit will snap into place as shown below. To remove the ICF-1280I series converter from the DIN rail, simply reverse Steps 1 and 2 above. - 6 -

Fiber Cable ST-Port Pinouts ST-Port to ST-Port Cable Wiring PROFIBUS Pin Assignment PIN Signal Name 1 N.C. 2 N.C. 3 PROFIBUS D+ 4 RTS 5 Signal common 6 5 V 7 N.C. 8 PROFIBUS D- 9 N.C. Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Slot Time Settings Although ICF-1280I series converters can be connected in different topologies with a large number of units, the total cable length and network topology can give rise to frame delays. A sufficient slot time is required to prevent the PROFIBUS master from timing out. Engineers are recommended to set the PROFIBUS master s slot time according to the following formulas. For linear and star topologies: Slot time = A + B L + 13 N Transmission Speed (kbps) A B 12000 811 120 6000 461 60 3000 261 30 1500 161 15 500 111 5 187.5 71 1.875 93.75 71 0.9375 45.45 411 0.4545 19.2 71 0.192 9.6 71 0.096-7 -

For redundant ring topology: Slot time = A + B L + C N Transmission Speed (kbps) A B C 12000 1651 240 28 6000 951 120 24 3000 551 60 24 1500 351 30 24 500 251 10 24 187.5 171 3.75 24 93.75 171 1.875 24 45.45 851 0.909 24 19.2 171 0.384 24 9.6 171 0.192 24 L: The length of the fiber optic in kilometer. N: The number of converters in the system. A, B, and C: Parameters set according to different baudrates. *To avoid frame conflicts, it is recommended to set the PROFIBUS command retry limit 3, and the slot time < 262128. DIP Switch Settings There are 8 DIP switches on the top panel of the ICF-1280I series converter. All DIP switches except SW5 are set to the factory default OFF position. Transmission Speed (kbps) SW1 SW2 SW3 SW4 Auto (default) OFF OFF OFF OFF 12000 OFF OFF OFF ON 6000 OFF OFF ON OFF 3000 OFF OFF ON ON 1500 OFF ON OFF OFF 500 OFF ON OFF ON 187.5 OFF ON ON OFF 93.75 OFF ON ON ON 45.45 ON OFF OFF OFF 19.2 ON OFF OFF ON 9.6 ON OFF ON OFF Setting ON OFF SW5 Fiber Link Monitor Disable SW8 Remote Fiber Diagnosis* Disable Topology SW6 SW7 Linear, Star (P1/P2 enable) OFF OFF Linear, Star (P1 disable) OFF ON Linear, Star (P2 disable) ON OFF Redundant Ring ON ON In Redundant Ring mode, the Fiber Link Monitor function is activated automatically. - 8 -

*Refer to the Remote Fiber Diagnosis section for instructions. If an ICF-1280I converter is deployed at the beginning or at the end of the topology in Linear mode or Star mode, the unused port should be disabled. In such cases, it is recommended to use an ICF-1180I series converter. Please use the ICF-1180I series with Rev. 1.3, or higher versions, to connect with the ICF-1280I series. LED Indicators There are 7 LED indicators on the front panel of the ICF-1280I series converter. LED Color Description Relay Status Solid Power is on green PWR1/PWR2 Power is off, or power error Off condition exists Open Solid Baud rate is detected, converter green is ready for communication green* Fiber diagnosis is finished Ready Detecting baudrate. red* Slotting time setting error red and green* Off System power is off Fiber port is receiving data /solid green P1/P2 Solid Fiber cable linking to Tx is Open (Fiber) red* abnormal Fiber cable linking to Rx is Open red* abnormal Off Fiber in idle state green PROFIBUS port is communicating Inner transceiver IC defective; PROFIBUS port Data Open communication error; P3 red Insufficient shielding of the bus (PROFIBUS) cable; Echo package timeout Solid red Echo package timeout, Open PROFIBUS UART character error Off PROFIBUS in idle state Fault Solid green red* Solid red* Fiber connections are working normally in Fiber Diagnosis mode Fiber abnormality occurred in another segment Fiber abnormality occurred on this converter If both power inputs experience an outage, the relay will become an open circuit for alarm purposes. *Refer to the following table for troubleshooting. - 9 -

Troubleshooting LED Indicators and Fiber Diagnosis LED Status Description Status/Troubleshooting Ready green Fiber diagnosis finished Check Fault LED; At least one converter is in Fiber Diagnosis mode; Check PROFIBUS master settings; Tx and Rx cables crossed Fault P1/P2 red Detecting baudrate Slot time setting green/red error red No PROFIBUS node; No PROFIBUS signal received; Tx and RX crossed over; Baudrate setting is incorrect. Recalculate the slot time; Set TSDR 11; Set HAS = greatest PROFIBUS node address + 1; Check consistency of operation mode for DIP switch 6/7; Check consistency of Fiber Link Monitor Mode for DIP switch 5 Fiber Use Fiber Diagnosis on another abnormality converter that is not adjacent to occurred in this converter another segment Solid red Fiber abnormality occurred on this converter red Rx fiber cable abnormality Solid red Tx fiber cable abnormality Check P1 and P2 LEDs Check the Rx fiber cable connecting to this port*; Tx and Rx cables crossed over; Partner module is powered OFF or defective Check the fiber cable linking to Tx of this port* P3 OFF PROFIBUS is idle Check the PROFIBUS device connection red PROFIBUS side error RS-485 cable is not terminated or only terminated at one end; Open bus cable; PROFIBUS D+ and D- crossed over; Short circuit on PROFIBUS cable; RS-485 driver is defective; Check slot time setting, baudrate, and operation mode If the abnormality indicated by the LED disappears in Fiber Diagnosis mode, check the consistency of the DIP switch settings on all the converters. If the Tx and Rx cables are both abnormal, the P1/P2 LED will shine red. Check the Rx cable first for troubleshooting. *If the Fault LED, P1 LED, and P2 LED are all lit/flashing red simultaneously, the Tx and Rx cables of P1 and P2 may be crossed over. - 10 -

ATTENTION This is a Class 1 laser/led product. Do not stare into the laser beam. Specifications PROFIBUS Communication PROFIBUS Interface PROFIBUS DP Number of Ports 1 Connector DB9 female Isolation Protection 2 kv Baudrate 9.6 Kbps to 12 Mbps Auto Baudrate Yes Compliant with EN 50170 Fiber Communication Connector type ST Number of Ports 2 Distance Single-mode fiber for 45 km Multi-mode fiber for 4 km Support Cable: Single-mode 8.3/125, 8.7/125, 9/125 or 10/125 μm Multi-mode 50/125, 62.5/125, or 100/140 μm Wavelength ICF-1280I-S: 1310 nm ICF-1280I-M: 820 nm Tx Output ICF-1280I-S: -7 dbm ICF-1280I-M: -14 dbm Rx Sensitivity ICF-1280I-S: -29 dbm ICF-1280I-M: -28 dbm Link Budget ICF-1280I-S: 21 dbm ICF-1280I-M: 14 dbm Transmission Half duplex Signal delay time 6.5 t bit (any input/output) Environmental Operating Temperature Storage Temperature Ambient Relative Humidity Atmospheric pressure 0 to 60 C (32 to 140 F) -40 to 75 C (-40 to 167 F) for T Models -40 to 75 C (-40 to 167 F), 5 to 95% (non-condensing) Up to 2000 m (795 hpa), higher altitudes on demand - 11 -

Power Input Power Voltage Connector Power Line Protection Power Polarity Protection Support over Currents Protection Power Consumption Relay Output Mechanical Dimensions (W H D) Material Gross Weight 12 to 48 VDC Terminal block IEC 6000-4-5 Level 3 (2 kv) Surge Protection Protects against V+/V- reversal 1.1 A Single mode: 165 ma @24 V Multi mode:140 ma @24 V Supports 1 digital output relay to alarm (Normal: close) Current carrying capacity: 2 A@30 VDC 39 115 70 mm Aluminum (1 mm) 225 g Regulatory Approvals Safety UL 508; EN 60950-1 EMC CE; FCC Part 15, sub part B, Class A EMI EN 55022, Class A; EN 55024 EMS EN 61000-4-2 (ESD), Level 2 EN 61000-4-3 (RS), Level 3 EN 61000-4-4 (EFT), Level 4 EN 61000-4-5 (Power Surge), Level 3 EN 61000-4-6 (CS), Level 3 EN 61000-4-8(PFMF), Level 1 Freefall IEC 60068-2-32 MTBF 792,085 hrs Green product RoHS, CRoHS, WEEE Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 - 12 -