Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

Similar documents
Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

IMPORTANT NOTICE WARRANTY WILL BE HONORED ONLY IF THE JAMBS HAVE BEEN INSTALLED IN ACCORDANCE WITH THESE INSTALLATION INSTRUCTIONS

Table of Contents F Series Frames

Parveneer Positive Pressure Fire Rated Frames Double rabbet with T stop for 20 minutes

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

FIB-R-MAX STANDARD SINGLE DOOR

TECHNICAL DATA SHEET STANDARD STEEL FRAMES SPECIFICATIONS MESKER STANDARD STEEL FRAMES

MH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

C-Series & S-Series Classic Frame with Transom (Single or Pair)

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

SPLIT FRAME INSTALLATION INSTRUCTIONS

Versatrim Side-Snap Frame

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Chapter 9. Windows and Exterior Doors

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Windload Post 9100/9600/9900 Installation Instructions

INSTALLATION INSTRUCTIONS

Thermally Broken Framing and Door Installation

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

Heavy Wall Applied Stop Tube Frame and Door Installation

Chapter 9. Windows and Exterior Doors

Chapter 18. Interior Doors

WINDLOAD POST WayneMark 8000, 8100 INSTALLATION INSTRUCTIONS

DCI Hollow Metal Technical Data

1 PREPARE HEADER AND ROUGH OPENING

DOOR COMPONENTS, INC Technical Data

Seamed Edge Doors 1000 Series

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

LATCHBOLT FILLER PLATE ASA FILLER PLATE A. SINGLE DOOR B. DOUBLE DOOR WITH MULLION C. DOUBLE DOOR WITHOUT MULLION END COVER MOUNTING BRACKET

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Make every component count.

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

INSTALLATION INSTRUCTIONS

Victory Fire Door Inspections

Model GT 2300 ICU Manual Swing Door Unequal Panels - Smoke Rated

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

Security Inspections are offered at no charge to Bunker Hill, Piney Point, and Hunters Creek residents.

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

STC 46 3-Sided Paired Frame (Double Rabbet Only)

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Murphy Door DIY Flush-Mount Bookshelf & Hardware Installation Manual

WOOD OUT SWING AWNING, CASEMENT, & HOPPER WINDOW

A & F Wood Products, Inc 5665 Sterling Drive Howell, Michigan Phone: Fax: Toll Free:

Dura-Lock Roof System

4-lite Patio Door. Installation Instructions

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION BULLET- RESISTANT DOORS

Chapter 22 - Cabinets & Vanities

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

INSTALLATION INSTRUCTIONS

Cabinetry Installation

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

Privacy Wall Glass Selections - Polished Edge Slider Door

Extra Wide Heavy Duty Plastic Lockers Series Locker Installation Instructions

Chapter 20. Exterior Finish Work

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

STC 42 3-Sided Single Frame (Double Rabbet Only)

Installation Instructions For Heavy Duty (FAS Models) and Median (FAM Models) Air Conditioners

Oxford Stalls Installation Instructions

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

Solid Core Wood Door / Steel Frame Packages

Installation Instruction

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Stainless Steel Continuous Hinges

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS

THIS PAGE INTENTIONALLY LEFT BLANK

PART #MSP-DCCST Flat Panel Tilt Mount

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

Installation Instructions

Frameless Inline Door With Return QCI5263

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

ICU TRACKLESS SLIDING DOOR

Installation Instructions. Oakmont Folding Doors

Two Panel Frameless Bypass Door

REVIEW ALL INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING INSTALLATION

INTERIOR ALUMINUM DOORS AND FRAMES

ROCKWELL. Two Panel Door. Half X Door. Double X Door. Z Combination Door

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

2300 BI-FOLD INSTALLATION GUIDE

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

Sliding Glass Door Assembly and Installation Guide

Transcription:

Installation Instructions 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC 7-2-1997 & UL-10C Door Requirements: Consult the door manufacturer to make sure that the doors are qualified for the type of hardware to be installed. Wall Requirements: Rated wood, steal framing or masonry wall. Minimum thickness: 4.625 inches Framing: 2 x 4 nominal dimension lumber or 2 ½ x 0.019 (25 gauge) minimum Steel framing. Rough opening size for 90-minute frames: (3 + 1) wider than net opening width for door (1 ½ + ½) higher than net opening height for door Note: 1. Dimensions are based on those to webs of buck framing members. 2. For masonry, a 2 x 3 nominal dimension lumber buck frame shell is to be attached to masonry with 3/8 expansion masonry anchors, spaced 26 on centers maximum. Rough Opening Preparation: See Drawings A 2 wide by 12 long by 0.036 (20 gauge) steel plate shall be supplied with the frame. This plate is for supplementary anchoring of strike plates, along the header or jamb leg of the frame. Plates shall be approximately centered at the strike elevation with approximately 1 lap over the web of the buck framing on the side of the wall that the strike is to be installed. Secure each plate to the buck framing with three suitable fasteners about 5 apart. Use 3/4 long, #8 pan head framing screws for steel buck framing. Use 1 long type S or W drywall screws for wood buck framing. Alternatively, 3 penny box nails may be used through predrilled holes in the steel plate for wood buck framing. 45 and 60- Minute Fire-Rated Frame Design Limitations: Minimum jamb depth: 4.625 Minimum rabbet for door: 1-7/8 Minimum stop height: 5/8 Minimum stop soffit: 1 Maximum sizes: (inches) For Swinging Doors Net Opening Overall Width Height Width Height Singles 48 108 50 109 Pairs 96 109 98 109 Page 1 of 5

Hinges: Strikes: Size and spacing to be in accordance with Table 2-4.3.1 of NFPA 80 1999, mortise type only. Continuous and invisible type 45/60-min. rated hinges are also acceptable. Per Templates for labeled latch sets, (including cylindrical, mortise or unit type), rim exit device, vertical rod fire exit devices, flush bolts and/or dead bolts. Wood Doors Maiman Company Supplied Parts: 1. Steel screw sleeves for strikes. Qty. 2 @ 6 cut 2 from 1 after jamb is installed. 2. #10 x 2 ½ drywall screws for strike attachment use for 4-7/8 and exit device strike. Qty. 4 3. #10 x 2 ½ drywall screw 1 for EVERY hinge to wall attachment. Qty. 8 4. 2 x 12 x 20 Ga. steel plate for latch or flushbolt strike. Qty. 1 5. #8 x 2 ½ drywall screws for head to leg attachment. Qty. 4 6. #8 x 2 ½" drywall screws for 2 ¾ strike or flushbolt strike attachment. Qty. 2 90-Minute Frame Installation: See Drawings Remove the frame from the carton and become familiar with the components by checking each component with the shipping list. Obtain any hardware item not supplied with your purchase (but required by these instructions) at your local door/frame hardware or building materials dealer. In the event your 45 or 60-minute frame was supplied without casing trim, you may install any wood, plastic or metal casing trim obtained from your local dealer. In the event your 45 or 60-minute frame was supplied without the required screws, they may be obtained from your local hardware dealer. To reduce soiling and staining of the frame finish and for ease of installation, it is recommended that all holes for fasteners through the frame and stop be predrilled before the fastener is inserted. Use 5/32 drill bits for #10 and 3/32 for #8 screws. Pilot holes from 65-70% of the fastener shank diameter are best. If needed, up to ¾ may be sawed from the bottom of each jamb to fit the rough opening. Use caution to make sure that this does not require trimming the bottom of the door. Some doors may not be trimmed at the bottom. Align the header section to the top of each jamb section. Drive two 2 ½ long, #8 screws through predrilled holes at each end of the header to the top of each jamb. Orient, position, align and square the assembled frame within the rough opening in the wall. See drawings. Position shims at about 2 from the top and bottom to fill the opening between the hinge jamb and wall buck framing. Drive a 2 ½ long, #8 dry wall screw immediately above or below each set of shims behind the stop of the frame. Do not completely tighten these screws until you are sure the shims have been adjusted to have the head within the width of the rough opening and with the hinge jamb in plumb. Insert shims under top and bottom hinges and install the door to the frame at these locations only. Close the door to check and adjust for alignment of the door from the frame stops and for 1/8 maximum clearance for wood doors or 3/16 maximum clearance for steel doors from the header and both jambs. In the case of door pairs, both doors should be similarly installed to adjust for 1/8 clearance for wood doors or 3/16 clearance for steel doors between the meeting edges and for 1/8 maximum offset along the meeting edges. When alignment is satisfactory, insert shims under the remaining hinge locations and install hinges. Place shims under each #8 frame attachment screw location, maximum 24 on center, between buck framing along both jamb and header section. Drive and tighten 2 ½ long, #8 dry wall screws under the stop through head and jambs into the buck framing, adjoining each set of shims. Recheck clearances and readjust if necessary. If stops were supplied loose, they should be attached with 1 ½ long finishing nails or 1 ½ long trim head screws, 12 on center, through the predrilled holes at this time. Preposition the stops on the frame to allow for any required labeled gasketing with the doors in the closed position. For flushbolt or latchset strikes, cut to length and insert steel screw sleeves through the 7/16 diameter predrilled holes in the frame to span the distance between the strike and buck framing or the 2 x 12 x 20 gauge steel plate previously installed to the buck framing. Install the strikes with #10 2 ½ long screws through the steel sleeves. 2 of 8

Surface strikes used for rim exit devices and vertical rod fire exit devices are sometimes installed to the jamb leg or header. These strikes require that 7/16 diameter holes be predrilled through both the stop and frame. Steel screw sleeves and 2 ½ long, #10 or 2 ½ long #8 screws are used to install surface strikes to the jamb header. Dead bolt strikes (mortise type) and closer surface brackets for closer arms do not require the 7/16 diameter holes or the steel screw sleeves. It is recommended that holes for the screws be predrilled. If mounted to the header, screws should extend through the stop and penetrate the frame by ½ minimum. If mounted to the face of the frame, a 16 gauge steel mounting plate may be cut up to 2 high by the width of the bracket or closer body and surface attached to the face of the frame with not less than two, #8, ¾ long screws through predrilled holes in the plate. The closer or closer arm bracket may then be screw attached to the mounting plate, using self-tapping screws provided with the closer. Check and adjust hardware to make sure door(s) are self-closing and self-latching. Break or saw off any shims that extend beyond the frame or wall on each side of the assembly. Fill the area between sets of shims, 45 or 60-minute frame and buck framing on each side of the wall with any setting type calk to a minimum depth of 1 or fill the entire area with rock wool. See Drawings. For installation in masonry, extend the calking or rock wool over the buck framing to bridge the 45 or 60-minute frame to the masonry. See Drawings. After the compound has hardened, install the casing trim on each side of the wall to the buck framing or to the 45 or 60-minute jamb. Use 1 ½ long trim head screws or 1 ½ long finishing nails, 24 on center, for installation of casing trim to wood or steel buck framing or the 90 minute frame. If desired, the screw and nail heads may be covered using a veneer color matched caulking or putty stick. If the frame has a natural wood veneer it may be stained and finished. CONGRATULATIONS! You may now enjoy the safety and appearance of your new 45 or 60-minute firerated frame from The Maiman Company. 3 of 8

HEADER HEAD STOP #8 x 2 1/2 DRYWALL SCREW 4 FURNISHED HEAD AND JAMB LEG ASSEMBLY DETAIL HEAD STOP IS FURNISHED @ FULL HEADER LENGTH FOR FIELD FITTING JAMB LEG JAMB LEG STOP 4 of 8

2.5" x 25GA WALL BOARD CASING TRIM SETTING TYPE JOINT COMPOUND OR ROCK WOOL CONTINOUS BETWEEN SHIMS EXAMPLE INSTALLATION DETAIL WOOD VENEER FIRE PROOF MATERIAL WOOD OR VENEERED COMPOSITE STOP DEPENDING ON SPECIES 2 1/2" LONG #8 24" ON CENTER 1 #10 x 2.5" BLACK DRYWALL SCREW TO REPLACE 1 STANDARD HINGE SCREW AT EACH HINGE LOCATION STEEL HINGE PER NFPA 80 5 of 8

2.5" x 25GA WALL BOARD CASING TRIM SETTING TYPE JOINT COMPOUND OR ROCK WOOL CONTINOUS BETWEEN SHIMS WOOD VENEER STRIKE EXAMPLE INSTALLATION DETAIL FIRE PROOF MATERIAL WOOD OR VENEERED COMPOSITE STOP DEPENDING ON SPECIES 2 1/2" LONG #8 24" ON CENTER 2" x 12" x 20 GA. STEEL PLATE 2 #10 OR #8 x 2 1/2" BLACK TO REPLACE BOTH STANDARD STRIKE SCREWS STEEL SCREW SLEEVES 6 of 8

26" O.C. MAX EXPANSION MASONARY ANCHORS 1.5 x 2.5 WOOD STUD OR 2.5 x 25 GA WALL BOARD SETTING TYPE JOINT COMPOUND OR ROCK WOOL CONTINOUS BETWEEN SHIMS MASONARY WOOD STUD EXAMPLE INSTALLATION DETAIL WOOD VENEER FIRE PROOF MATERIAL WOOD OR VENEERED COMPOSITE STOP DEPENDING ON SPECIES 2 1/2" LONG #8 24" ON CENTER 1 #10 x 2.5" BLACK DRYWALL SCREW TO REPLACE 1 STANDARD HINGE SCREW AT EACH HINGE LOCATION STEEL HINGE PER NFPA 80 CASING TRIM 7 of 8

1.5 x 2.5 WOOD STUD 26" O.C. MAX EXPANSION MASONARY ANCHORS 1.5 x 2.5 WOOD STUD OR 2.5 x 25 GA WALL BOARD CASING TRIM SETTING TYPE JOINT COMPOUND OR ROCK WOOL CONTINOUS BETWEEN SHIMS MASONARY WOOD STUD STRIKE EXAMPLE INSTALLATION DETAIL WOOD VENEER FIRE PROOF MATERIAL WOOD OR VENEERED COMPOSITE STOP DEPENDING ON SPECIES 2 1/2" LONG #8 24" ON CENTER 2" x 12" x 20 GA. STEEL PLATE 2 #10 OR #8 x 2 1/2" BLACK TO REPLACE BOTH STANDARD STRIKE SCREWS STEEL SCREW SLEEVES 8 of 8