Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Similar documents
Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PFE and CM-PFE.2

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relay CM-PVE

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relays

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22

Three-phase monitoring relay CM-PBE

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays Product group picture

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relay

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Table of contents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-MFS.21

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-SDD.22

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-TGD.22

Three-phase monitoring relay

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-D 12/2.1

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

CP-E range Benefits and advantages

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

CP-T range Product group picture

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Control module CP-A CM

Thermistor motor protection relays

Primary switch mode power supplies Product group picture

CP-T range Benefits and advantages

Power supply CP-E 24/0.75

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Control module CP-A CM

Pluggable interface relays CR-U Universal relays

Power supply CP-E 24/2.5

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Power supply CP-D 24/1.3

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Analog signal converters CC range

Thermistor motor protection relays

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Electronic timer CT-SDE

Signal converters Index

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

CM-IWM.11 Insulation monitoring relay

Electronic measuring and monitoring relays CM-range

XUA1 - AC Voltage and phase balance relay

Transcription:

Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage as well as phase unbalance. The device can be used for mains with a frequency of 45-440 Hz and is available with two different terminal versions. You can choose between the proven screw connection technology (double-chamber cage connection terminals) and the completely tool-free Easy Connect Technology (push-in terminals). 2CDC 251 065 V0011 Characteristics Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance TRMS measuring principle Automatic phase sequence correction configurable Interrupted neutral monitoring Monitoring of single-phase mains Can be used for mains with a frequency of 45 to 440 Hz Threshold values for over- and undervoltage as well as phase unbalance are adjustable as absolute values Tripping delay T v can be adjusted or switched off by means of a logarithmic scale (0 s; 0,1-30 s) ON-delayed or OFF-delayed tripping delay selectable Powered by the measuring circuit Precise adjustment by front-face operating controls Screw connection technology or Easy Connect Technology available Housing material for highest fire protection classification UL 94 V-0 Tool-free mounting on DIN rail as well as demounting 1 x 2 or 2 x 1 c/o (SPDT) contacts configurable 22.5 mm (0.89 in) width 3 LEDs for the indication of operational states

Order data Three-phase monitoring relays Type Rated control supply voltage = measuring voltage Connection technology Order code CM-MPS.23P 3 x 180-280 V AC Push-in terminals 1SVR740885R4300 CM-MPS.23S Screw terminals 1SVR730885R4300 Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SVR430029R0100 MAR.12 Marker label for devices with DIP switches 1SVR730006R0000 COV.11 Sealable transparent cover 1SVR730005R0100 2 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Connection technology Maintenance free Easy Connect Technology with push-in terminals Type designation CM-xxS.yyP Approved screw connection technology with double-chamber cage connection terminals Type designation CM-xxS.yyS 2CDC 253 026 F0011 2CDC 253 025 F0011 Push-in terminals Tool-free connection of rigid and flexible wires with wire end ferrule Easy connection of flexible wires without wire end ferrule by opening the terminals No retightening necessary One operation lever for opening both connection terminals For triggering the lever and disconnecting of wires you can use the same tool (Screwdriver according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in)) Constant spring force on terminal point independent of the applied wire type, wire size or ambient conditions (e. g. vibrations or temperature changes) Opening for testing the electrical contacting Gas-tight Double-chamber cage connection terminals Terminal spaces for different wire sizes One screw for opening and closing of both cages Pozidrive screws for pan- or crosshead screwdrivers according to DIN ISO 2380-1 Form A 0.8 x 4 mm (0.0315 x 0.157 in), DIN ISO 8764-1 PZ1 ø 4.5 mm (0.177 in) Both the Easy Connect Technology with push-in terminals and screw connection technology with double-chamber cage connection terminals have the same connection geometry as well as terminal position. Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-3

Functions Operating controls 1 Adjustment of the threshold value >U for overvoltage 2 Adjustment of the threshold value <U for undervoltage 3 Indication of operational states R/T: yellow LED Relay status / timing 1 2 F1: red LED Fault message F2: red LED Fault message 4 Adjustment of the threshold value Asym. for phase unbalance 2CDC 251 065 V0011 3 4 5 5 Adjustment of the tripping delay T v 6 DIP switches (see DIP switch functions) 6 Application The three-phase monitoring relay CM-MPS.23 is designed for use in three-phase mains for monitoring the phase parameters phase sequence, phase failure, over- and undervoltage as well as phase unbalance. The device can be used for mains with a frequency of 45-440 Hz. The CM-MPS.23 provides an adjustable tripping delay and works according to the closed-circuit principle. Operating mode The unit is adjusted with front-face operating controls. The selection of ON- A or OFF- B delay, phase sequence monitoring activated k or phase sequence monitoring deactivated l, 2 x 1 c/o i or 1 x 2 c/o j (SPDT) contacts as well as automatic phase sequence correction activated m or automatic phase sequence correction deactivated n is made with DIP switches. Potentiometers, with direct reading scale, allow the adjustment of the threshold values for overvoltage (>U), undervoltage (<U), phase unbalance (Asym %) and the tripping delay T v. The tripping delay T v is adjustable over a range of instantaneous to a 30 s delay. Timing is displayed by a flashing yellow LED labelled R/T. For monitoring single-phase mains, all three external conductors (L1, L2, L3) have to be jumpered and connected as one single conductor. Phase sequence monitoring has to be deactivated and the threshold value for phase unbalance has to be set to the maximum (25 %). 4 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Adjustment potentiometer Threshold values By means of three separate potentiometers with direct reading scales, the threshold values for over- and undervoltage as well as for phase unbalance can be adjusted within the measuring range. Measuring range for overvoltage Measuring range for undervoltage Measuring range for phase unbalance 3 x 240-280 V AC 3 x 180-220 V AC 2-25 % of average of phase voltages Tripping delay T v The tripping delay T v can be adjusted within a range of 0.1 to 30 s by means of a potentiometer with logarithmic scale. By turning to the left stop, the tripping delay can be switched off. Indication of operational states LEDs, status information and fault messages Operational state R/T: LED yellow F1: LED red F2: LED red Control supply voltage applied, output relay energized V - - Tripping delay T v active W - - Phase failure - V W Phase sequence - W alternating Overvoltage - V - Undervoltage - - V Phase unbalance - V V Interruption of the neutral - V W Adjustment error 1) W W W 1) Possible misadjustments of the front-face operating controls: Overlapping of the threshold values: The threshold value for overvoltage is set to a smaller value than the threshold value for undervoltage. DIP switch 3 = OFF and DIP switch 4 = ON: Automatic phase sequence correction is activated and selected operating mode is 1 x 2 c/o (SPDT) contacts DIP switch 2 and 4 = ON: Phase sequence detection is deactivated and the automatic phase sequence correction is actived. Function descriptions / diagrams Interrupted neutral monitoring The interruption of the neutral in the main to be monitored is detected by means of phase unbalance evaluation. If the star point is displaced by asymmetrical load in the three-phase main, an interrupted neutral will be detected. Determined by the system, in case of unloaded neutral, i.e. symmetrical load between all three phases, it may happen that an interruption of the neutral will not be detected. 2CDC 252 021 F0011 Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-5

Phase sequence and phase failure monitoring Applying control supply voltage begins the fixed start-up delay T s. When T s is complete and all phases are present with correct voltage, the output relays energize and the yellow LED R/T is on. Phase sequence monitoring: If phase sequence monitoring is activated (DIP switch 2 = OFF), the output relays de-energize as soon as a phase sequence error occurs. The fault is displayed by alternated flashing of the LEDs F1 and F2. The output relays re-energize automatically as soon as the phase sequence is correct again. If phase sequence monitoring is deactivated (DIP switch 2 = ON), a phase sequence error will not cause tripping of the relays. The output relays do not change state and the LEDs F1 and F2 don t flash. Phase failure monitoring: The output relays de-energize instantaneously if a phase failure occurs. The fault is indicated by lightning of LED F1 and flashing of LED F2. The output relays re-energize automatically as soon as the voltage returns to the tolerance range. L1, L2, L3 Measured value T s L1, L2, L3 L1, L3, L2 L1, L2, L3 L1, L2 L1, L2, L3 L1 L1, L2, L3 L3 L2, L3 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms 2CDC 252 094 F0207 6 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Over- and undervoltage monitoring 1 x 2 c/o (SPDT) contacts j Applying control supply voltage begins the fixed start-up delay T s. When T s is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize and the yellow LED R/T is on. Type of tripping delay = ON-delay A If the voltage to be monitored exceeds or falls below the set threshold value, the output relays de-energize after the set tripping delay T v is complete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %. The LED R/T is on. L1, L2, L3 > U > U - 5 % Measured value < U + 5 % < U 15-18 15-16 25-28 25-26 Ts Tv <Tv Tv F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms T v = adjustable tripping delay 2CDC 252 090 F0207 Type of tripping delay = OFF-delay B If the voltage to be monitored exceeds or falls below the set threshold value, the output relays de-energize instantaneously and the LED R/T turns off. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, the output relays reenergize automatically after the set tripping delay T v is complete. The LED R/T flashes during timing and turns steady when timing is complete. L1, L2, L3 > U > U - 5 % Measured value < U + 5 % < U Ts Tv <Tv <Tv 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms T v = adjustable tripping delay 2CDC 252 091 F0207 Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-7

Over- and undervoltage monitoring 2 x 1 c/o (SPDT) contacts i Applying control supply voltage begins the fixed start-up delay T s. When T s is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize. The yellow LED R/T is on as long as at least one output relay is energized. Type of tripping delay = ON-delay A If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes after the set tripping delay T v is complete.the LED R/T flashes during timing. The corresponding output relay re-energizes automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %. L1, L2, L3 > U > U - 5 % Measured value < U + 5 % < U 15-18 15-16 25-28 25-26 Ts Tv <Tv Tv F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms T v = adjustable tripping delay 2CDC 252 006 F0207 Type of tripping delay = OFF-delay B If the voltage to be monitored exceeds or falls below the set threshold value, output relay R1 (overvoltage) or output relay R2 (undervoltage) de-energizes instantaneously. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 5 %, the corresponding output relay re-energizes automatically after the set tripping delay T v is complete. The LED R/T flashes during timing. L1, L2, L3 > U > U - 5 % Measured value < U + 5 % < U Ts Tv <Tv <Tv 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms T v = adjustable tripping delay 2CDC 252 007 F0207 8 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Phase unbalance monitoring Applying control supply voltage begins the fixed start-up delay T s. When T s is complete and all phases are present with correct voltage and with correct phase sequence, the output relays energize and the yellow LED R/T is on. Type of tripping delay = ON-delay A If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays de-energize after the set tripping delay T v is complete. The LED R/T flashes during timing and turns off as soon as the output relays de-energize. The output relays re-energize automatically as soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 20 %. The LED R/T is on. L1, L2, L3 Unbalance Unbalance - Hysteresis Measured value Unbalance + Hysteresis Unbalance 15-18 15-16 25-28 25-26 L3 L1, L2, L3 L1, L2 Ts Tv <Tv Tv F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms T v = adjustable tripping delay 2CDC 252 092 F0207 Type of tripping delay = OFF-delay B If the voltage to be monitored exceeds or falls below the set phase unbalance threshold value, the output relays deenergize instantaneously and the LED R/T turns off. As soon as the voltage returns to the tolerance range, taking into account a fixed hysteresis of 20 %, the output relays reenergize automatically after the set tripping delay T v is complete. The LED R/T flashes during timing and turns steady when timing is complete. L1, L2, L3 Unbalance Unbalance - Hysteresis Measured value Unbalance + Hysteresis Unbalance Ts L3 L1, L2, L3 L1, L2 Tv <Tv <Tv 2CDC 252 093 F0207 15-18 15-16 25-28 25-26 F1: red LED F2: red LED R/T: yellow LED T s = start-up delay fixed 200 ms T v = adjustable tripping delay 2CDC 252 093 F0207 Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-9

Automatic phase sequence correction This function can be selected only if phase sequence monitoring is activated k (DIP switch 2 = ON) and operating mode 2 x 1 c/o (SPDT) contact j is selected (DIP switch 3 = OFF). Applying control supply voltage begins the fixed start-up delay T s1. When T s1 is complete and all phases are present with correct voltage, output relay R1 energizes. Output relay R2 energizes when the fixed start-up delay T s2 is complete and all phases are present with correct phase sequence. Output relay R2 remains de-energized if the phase sequence is incorrect. If the voltage to be monitored exceeds or falls below the set threshold values for phase unbalance, over- or undervoltage or if a phase failure occurs, output relay R1 de-energizes and the LEDs F1 and F2 indicate the fault. Output relay R2 is responsive only to a false phase sequence. In conjunction with a reversing contactor combination, this enables an automatic correction of the rotation direction. See circuit diagrams. L1, L2, L3 Measured value L1, L2, L3 L1, L2 L1, L2, L3 L1, L3, L2 T s1 L3 T s1 15-18 15-16 25-28 25-26 F1: red LED T s2 T s2 F2: red LED R/T: yellow LED T s1 = start-up delay of R1 fixed 250 ms T s2 = start-up delay of R2 fixed 200 ms 2CDC 252 085 F0107 L1 L2 L3 L1 L2 L3 1 3 5 -F1 2 4 6 K1 15 18 16 1 -K2 2 3 4 5 6 1 -K3 2 3 4 5 6 N K1 25 K1 28 26 A1 K2 A2 K3 A1 A2 H1 2CDC 253 008 F0014 -F2 1 3 5 2 4 6 W1 V1 U1 97 98 -M1 95 96 M 3 ~ 2CDC 252 087 F0b07 Control circuit diagram (K1 = CM-MPS.23) Power circuit diagram Electrical connection L1 N L1 L2 L2 L3 15 L3 25 L1, L2, L3, N Control supply voltage = measuring voltage 15-16/18 Output contacts - closed-circuit principle 25-26/28 N 16 18 26 28 26 25 28 16 15 18 2CDC 252 036 F0008 Connection diagram CM-MPS.23 10 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

DIP switches Position 4 3 2 1 ON OFF 2CDC 252 041 F0008 1 Timing function ON ON-delayed A: In case of a fault, the de-energizing of the output relays and the respective fault message are suppressed for the adjusted tripping delay T v. OFF OFF-delayed B: In case of a fault, the output relays de-energize instantaneously and a fault message is displayed and stored for the length of the adjusted tripping delay T v. Thereby, also momentary undervoltage conditions are recognized. 2 Phase sequence monitoring ON Phase sequence monitoring deactivated l Phase sequence errors will not cause tripping of the relays. OFF Phase sequence monitoring activated k The output relays de- energize as soon as a phase sequence error occurs. The output relays re- energize automatically as soon as the phase sequence is correct again. 3 Operating principle of the output relays ON 2 x 1 c/o (SPDT) contact i Depending on the configuration of automatic phase sequence correction and on the fault type, the output relays R1 (15-16/18) and R2 (25-26/28) react differently, if operating principle 2 x 1 c/o (SPDT) contact is selected. Automatic phase sequence correction deactivated n: Overvoltage: only 1st c/o (SPDT) contact R1 (15-16/18) switches Undervoltage: only 2nd c/o (SPDT) contact R2 (25-26/28) switches Phase unbalance, phase sequence, phase failure, interrupted neutral: both output relays R1 (15-16/18) and R2 (25-26/28) react synchronously Automatic phase sequence correction activated m: Overvoltage, undervoltage, phase unbalance, phase failure, interrupted neutral: only 1st c/o (SPDT) contact R1 (15-16/18) switches Phase sequence: only 2nd c/o (SPDT) contact R2 (25-26/28) switches Operating principle 2 x 1 c/o (SPDT) contact is mandatory if automatic phase sequence correction is activated. OFF 1 x 2 c/o (SPDT) contacts j If operating principle 1 x 2 c/o (SPDT) contacts is selected, both output relays R1 (15-16/18) and R2 (25-26/28) react synchronously, independent of the fault type. 4 Automatic phase sequence correction ON Phase sequence correction activated m In conjunction with a reversing contactor combination, it is ensured that the correct phase sequence is applied to the input terminals of the load. OFF Phase sequence correction deactivated n No automatic phase sequence correction in case of phase sequence error. Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-11

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuit Type Supply circuit = measuring circuit Rated control supply voltage U s = measuring voltage 3 x 180-280 V AC Rated control supply voltage U s tolerance -15...+10 % Rated frequency 50/60/400 Hz Frequency range 45-440 Hz Typical current / power consumption 5 ma / 4 VA (230 V AC) CM-MPS.23 L1, L2, L3, N Measuring circuit L1, L2, L3, N Monitoring functions Phase failure J Phase sequence can be switched off Automatic phase sequence correction configurable Over-/undervoltage J Phase unbalance J Interrupted neutral J Measuring range Overvoltage 3 x 240-280 V AC Undervoltage 3 x 180-220 V AC Phase unbalance 2-25 % of average of phase voltages Thresholds Overvoltage adjustable within measuring range Undervoltage adjustable within measuring range Phase unbalance (switch-off value) adjustable within measuring range Tolerance of the adjusted threshold value 6 % of full-scale value Hysteresis related to Over-/undervoltage fixed 5 % the threshold value Phase unbalance fixed 20 % Rated frequency of the measuring signal 50/60/400 Hz Frequency range of the measuring signal 45-440 Hz Maximum measuring cycle time 100 ms Accuracy within the rated control supply voltage tolerance DU 0.5 % Accuracy within the temperature range DU 0.06 % / C Measuring method True RMS Timing circuit Start-up delay T s and T s2 fixed 200 ms Start-up delay T s1 fixed 250 ms Tripping delay T v ON- or OFF-delay 0 s; 0.1-30 s adjustable Repeat accuracy (constant parameters) < w0.2 % Accuracy within the rated control supply voltage tolerance Dt 0.5 % Accuracy within the temperature range Dt 0.06 % / C User interface Indication of operational states Relay status / timing R/T yellow LED Fault message F1 red LED Fault message F2 red LED Details see table LEDs, status information and fault messages on page 5 and Function descriptions / diagrams on page 5. 12 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Output circuits Kind of output 15-16/18 25-26/28 Operating principle closed-circuit principle 1) Contact material Rated operational voltage U e Minimum switching voltage / Minimum switchting current Maximum switchting voltage / Maximum switching current Rated operational current I e AC-12 (resistive) at 230 V 4 A AC rating (UL 508) Mechanical lifetime AC-15 (inductive) at 230 V DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power at B 300 15-16/18, 25-26/28 relays, 1 x 2 or 2 x 1 (SPDT) contact(s) configurable AgNi alloy, Cd free 250 V 24 V / 10 ma see load limit curves 3 A 4 A 2 A B 300 300 V AC 5 A 3600/360 VA 30 x 10 6 switching cycles Electrical lifetime AC-12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit protection n/c contact n/o contact 6 A fast-acting 10 A fast-acting General data MTBF on request Duty time 100 % Dimensions see Dimensional drawings Weight Screw connection technology Easy Connect Technology (push-in) net weight CM-MPS.23 0.149 kg (0.328 lb) 0.138 kg (0.304 lb) gross weight CM-MPS.23 0.174 kg (0.384 lb) 0.163 kg (0.359 lb) Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units horizontal 10 mm (0.39 in) Material of housing UL 94 V-0 Degree of protection housing IP50 terminals IP20 1) Closed-circuit principle: Output relay(s) de-energize(s) if measured value exceeds or falls below the adjusted threshold value. Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-13

Electrical connection Screw connection technology Easy Connect Technology (Push-in) Connnecting capacity fine strand with(out) wire end ferrule 1 x 0.5-2.5 mm² (1 x 18-14 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) 2 x 0.5-1.5 mm² (2 x 18-16 AWG) rigid 1 x 0.5-4 mm² (1 x 20-12 AWG) 2 x 0.5-2.5 mm² (2 x 20-14 AWG) 2 x 0.5-1.5 mm² (2 x 20-16 AWG) Stripping length 8 mm (0.32 in) Tightening torque 0.6-0.8 Nm (7.08 lb.in) - Environmental data Ambient temperature ranges operation -25...+60 C storage -40...+85 C Damp heat, cyclic (IEC/EN 60068-2-30) 6 x 24 cycle, 55 C, 95 % RH Climatic class 3K3 Vibration, sinusoidal Class 2 Shock Class 2 Isolation data Type Rated insulation input circuit / output circuit 600 V voltage U i output circuit 1 / output circuit 2 300 V Rated impulse withstand voltage U imp input circuit / output circuit 6 kv, 1.2/50 µs output circuit 1 / output circuit 2 4 kv, 1.2/50 µs Basic insulation input circuit / output circuit 600 V Protective separation input circuit / (IEC/EN 61140, EN 50178) output circuit - Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60947-5-1, IEC/EN 60255-27, EN 50178 Low Voltage Directive 2014/35/EU EMC directive 2014/30/EU RoHS directive 2011/65/EU 14 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kv / 2 khz) surge IEC/EN 61000-4-5 Level 4 (2 kv L-N) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) radio-frequency fields harmonics and interharmonics IEC/EN 61000-4-13 Class 3 Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22, Class B EN 55022 high-frequency conducted IEC/CISPR 22, EN 55022 Class B Technical diagrams Load limit curves V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 194 F0205 V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 193 F0205 AC load (resistive) DC load (resistive) F 1.0 0.9 0.8 0.7 0.6 Switching cycles 250 V resistive load 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Derating factor F for inductive AC load 2CDC 252 192 F0205 Switching current [A] 2CDC 252 148 F0206 Contact lifetime Data sheet Multifunctional three-phase monitoring relays CM-MPS.23-15

Dimensions in mm and inches 113.4 4.47 105.9 4.17 22.5 0.89 85.6 3.37 103.7 4.08 2CDC 252 009 F0011 Accessories in mm and inches 22.5 0.89 8 0.32 4.8 0.19 6.5 0.256 62.5 2.461 60 2.362 70 2.756 10 11.5 0.394 0.453 20 0.787 2CDC 252 008 F0010 22.2 0.874 4T22 19.9 0.783 7.85 0.309 2CDC 252 020 F0011 68 2.68 front to back 110.5 4.31 2CDC 252 010 F0011 ADP.01 Adapter for screw mounting MAR.12 Marker label for devices with DIP switches COV.11 Sealable transparent cover Further documentation Document title Document type Document number Electronic relays and controls Catalog 2CDC 110 004 C02xx CM-MPS.23, CM-MPS.43, CM-MPN.52, CM-MPN.62, CM-MPN.72 Instruction manual 1SVC 730 530 M0000 You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Measuring and monitoring relays. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. 16 - Multifunctional three-phase monitoring relays CM-MPS.23 Data sheet

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 112 203 D0201 Rev. C (03.2018) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2018 ABB All rights reserved