USES AND APPLICATIONS

Similar documents
USES AND APPLICATIONS

USES AND APPLICATIONS

USES AND APPLICATIONS

USES AND APPLICATIONS

GLASS HEAT TREATMENT MULTIVER GLASS TEMPERED GLASS HEAT-STRENGTHENED GLASS HEAT SOAK TESTED TEMPERED GLASS. DATA SHEET / Quebec. Version 2.

USES AND APPLICATIONS

Technical Information

USES AND APPLICATIONS

High Performance Glass Products for digital signage, digital displays and touch screens

Basically brilliant Vanceva White Collection. High-performance interlayers for laminated glass

Decorative Laminated Architectural Glass

Acid etched float glass

Ph P y h s y i s c i s c s R ev e i v e i w e : R ad a i d a i t a io i n o UV VIBGYOR infra-red

Tempered Glass. Tempered glass. Product introduction

Fading Protection and SageGlass Products

Technical Information

BIRD FRIENDLY ACID-ETCHED GLASS

Architectural coated glass. Product application information BUILD WITH LIGHT. Reference Code: SUNGUARD_Spandrel_TI_EN_0216

Glass in Today s Architecture

DIGITALLY PRINTED GLASS

Introduction Description Capabilities Applications Characteristics Additional Important Information

FUSION GLASS : DIGITAL PRINT LAMINATE

Glass in Today s Architecture

Terminology Annealed glass Glass created by a process that moves it, in a molten form, along a long oven where it is heated and then very slowly coole

Edge Grinding and the Issues Surrounding Fabrication Prior to Heat-Treatment

Whether it be a transparent, translucent or an

FUSION GLASS : KILN FORMED

FUSION GLASS : COLOUR LAMINATE

FUSION GLASS : MESH LAMINATE

1 Tempered Glass. Effect Comparison. 1. The common glass falls into pieces with sharp edges when it's broken.

FUSION GLASS : SURFACE DECORATED

Designing with Glass. Privacy & Translucency

PSP Digital Print Range

The Window Film Company About Us

GLASS. the art of toughness

GLASSILED CAPTURE THE LIGHT

and constantly reviewing its data, SCHOTT assumes no liability or guarantees for the completeness, correctness or up to

Interior Design Materials. Glass & Ceramics. Haval Sami Ali

V. TECHNICAL ANNEXES REGULATIONS

Iv. GLASSES.

Avery Dennison Architectural Window Films

Contact Euroglas GmbH, D Haldensleben Tel.: , Fax:

FOCUS ON SATIN-FINISH GLASS MATELUX

Processing guide for IMAGIN

FOCUS ON ENHANCED SOLAR CONTROL FOR COMFORT STOPSOL

Iv. GLASSES.

Prel-Lam LC-LTI Liquid Crystal Laminated Glass

Recommended Applications for Heat-Treated Glass

Date: Subject: Electromagnetic shielding and low-e glass

Technical Information

Glass Curtain Wall. 1. Point Supported Glass Curtain Wall 2. Exposed-Frame Glass Curtain Wall 3. Hidden-Frame Glass Curtain Wall

GLASS UNITS AND SINGLE GLASS.

Backpainted Glass Technical Manual

GLASS AND GLAZING OPTIONS

Designed for Your Life. Guaranteed. Premium Vinyl Replacement Windows

express yourself in glass by by

PROCESSING GUIDE. Stopsol Classic Stopsol Supersilver Stopsol Silverlight. Stopsol Phoenix (only available in the Russian Federation) Blackpearl

More than 90 different designs available. 2 designs for outdoor decoration only.

Enhancing The Skyline With Quality. Air flotation technology by Tecnoglass TECNOAIR. Record-breaking quality on tempered glass.

Technical Information

Inteligent Glass (STG)

SGG PLANILAQUE EVOLUTION. Lacquered glass installation and use instructions

Pilkington OptiView Protect. Pilkington OptiView. Handling and Processing Guidelines

Glass in every form. HERO Form

- BALUSTRADES - A light elegance for any home or business.

Classification of reaction to fire of glass products Recommendation from Glass for Europe

Relevant standards and guidelines

FLAT GLASS TECHNOLOGY

Description. Applications. GOLDEN FAITH SILVER MIRROR ultra durable coating silver mirror

Saflex PVB Earth Tones

Description. Appliance

ith OKNA s Bay and Bow Windows we are pleased to provide breakthrough products which offer a myriad of options to seamlessly blend with any decor to

Pilkington OptiView Protect. Pilkington OptiView. Handling and Processing Guidelines

ELECTRONIC DISPLAY. "Best in Show" award winner of "SID Display Week 2014"

1 To T u o g u h g e h n e e n d e Gl G a l s a s s / Te T m e p m e p r e e r d e Gl G a l s a s

extend your outdoor lifestyle

Window component characteristics

Handling, Inspecting and Fabricating Pilkington OptiView Anti-Reflective Glass

DAYLIGHT HARVESTING MULTIWALL. Applications:

BLACKOUT 100% BLACKOUT 100% KIBO 8500 INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION COLLECTION

DF-PA Blaze & Chill DF-LAM Blaze & Chill. Product Description

Opalux Designer Window Films

SPECIFICATIONS FOR 3M TM PRESTIGE SUN CONTROL WINDOW FILMS

PROCESSING GUIDE OLTRELUCE

AMIRAN the glass you can t see

Guide Specifications Section

BLACKOUT 100% BLACKOUT 100% KARELLIS INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION COLLECTION

STADIP LITE Weight-saving solution

SOLAR GAIN LOW E COATING DETECTOR

CONTEMPORARY ALUMINUM. Stylish aluminum frames with full-view glass Black anodized aluminum, white laminated privacy glass

Mirror. Mirror Mirror Mirror

TI 009E. Technical Information Assessment of the visual quality of screen printing

Guideline for assessing. quality of enamelled and screenprinted. perfektion in glas. Rev Page 1 of 10

ARCHITECTURAL GLASS CARVART.COM. O3 Pattern 2018 CARVART

CUSTOM VINYL WINDOWS

Product Guide Windows. Transform ordinary spaces with high quality, eye-catching window graphics

FUZION Fused Glass Countertops - Andrew Pearson Design

Series 9000 Vinyl Fixed Window

LUXAR Anti reflective coated glass Handling Procedures for LUXAR

USE AND CARE GUIDE. Rochester Rectangular Dining Table. Product code: UPC code: Vendor Item: SM-K-750T-66

Transcription:

REFLECTIVE GLASS USES AND APPLICATIONS DATA SHEET / Quebec Version 2.0

Type of glass offered by Multiver What is reflective glass? During the manufacturing process, glass manufacturers add certain reflective metallic oxides to the surface of clear or tinted glass, or to the glass composition (pyrolytic method), which helps increase glass reflectance. Glass reflectance allows to reflect a certain proportion of the radiation emitted by various sources. Multiver offers a wide selection of reflective glass products. It is important to specify that glass reflectance is very closely related to the ratio of illumination levels between the two sides of the glass, which is why at night we see inside buildings with reflective glass when a light is on in the exposed room.! *Various low emissivity (low-e) glass products have a reflective quality. For further information, consult the Low Emissivity (Low-E) Glass document. STANDARDS AND CERTIFICATES Multiver meets the following requirements : ASTM C1036 Flat Glass CAN/CGSB-12.3-M91 Flat, Clear Float Glass *Other standards and certificates may apply. 2/11

USES Reflective glass can be used in a number of applications, such as : Glass partitions Windows and curtain walls Spandrel glass Balustrades Skylights Glass floors Door glazing Automotive glass Decorative crafts 3/11

BENEFITS From an esthetic point of view, reflective glass gives buildings a distinguished and/or private look. It helps reduce heat gain, thus reducing air conditioning costs and enhancingoccupants well-being (see solar heat gain coefficient in Table 2 on reflective glass performance data). It reduces ultraviolet radiation inside the building. Extremely versatile, this product can be utilized in commercial, residential and institutional projects. The wide variety of reflective glass allows for a multitude of visual effects. It can be combined with low-e glass to improve thermal resistance (R-value) and overall performance of the insulated unit. Virtually unlimited combinations allow to modify glass performance. Reflective glass can be used in monolithic form as well as in double- or triple-glazed insulated glass units. It can also be sandblasted, silk-screened, shaped, laminated, bevelled and enamelled. Indoors, it can be used for its esthetic appeal and to complement the furniture and decoration. Its acoustic and mechanical performance is similar to that of standard glass of the same thickness and size. When reflective glass is combined in an insulated glass unit with spandrel glass in position 4, the resulting combination can create a reflective effect similar to that of insulated units with reflective glass of a building in daylight. Considering the lower light transmittance associated with reflective glass, interior glare is also reduced while providing privacy from the outside. It can be assembled with integral blinds as well as smart glass, thus providing the ultimate comfort. 4/11

SUPPLIERS OF AVAILABLE REFLECTIVE PRODUCTS Multiver offers a large variety of reflective glass products, most of which are listed below. Products may be added to the list or removed from it, depending on demand. TABLE 1 : Name and thickness of available glass products Stopsol Clear SunGuard Silver 20 Eclipse Advantage Clear Solarcool Azuria * Stopsol Grey Eclipse Advantage Blue-Green Solarcool Graylite Stopsol Bronze Eclipse Advantage EverGreen Solarcool Pacifica * Stopsol Green Eclipse Advantage Arctic Blue Solarcool Solarblue Stopsol Dark Blue Eclipse Advantage Bronze Solarcool Solarbronze Eclipse Advantage Grey Solarcool Solargray * Mirropane TM (transparent mirror) Solarcool Solexia MirroView TM MirroView TM 50/50 * Certain glass products are not kept in stock. A minimum quantity is required for some products. * AGC offers the Supersilver series with tinted glass. These products are slightly more reflective than products from the Stopsol series and are also available from Multiver. * Several other reflective glass products are available. For further information, please contact us. 5/11

PERFORMANCE DATA Below is a comparative table of various possible performance aspects of reflective glass combined or not with low-e glass. We compared a grey (Silver 20) reflective glass with a bronze (Solarcool Solarbronze) and a green-tinted (Solarcool Solexia) reflective glass. By varying the glass composition, you can obtain high-performance products. Performance data were collected using Window 6.3, an independent software by LBNL specially designed to determine the performance of different products PRODUCT CLEAR GLASS - clear - clear SOLARCOOL SOLARBRONZE REFLECTIVE GLASS - Solarcool Solarbronze - clear - Solarcool Solarbronze - Econover Select 63 (surf. 3) SOLARCOOL SOLEXIA REFLECTIVE GLASS - Solarcool Solexia - clear - Solarcool Solexia - Econover Select 63 (surf. 3) SILVER 20 REFLECTIVE GLASS - Silver 20 - clear - Silver 20 - Econover Select 63 (surf. 3) - Silver 20-12.70 mm argon - Econover Select 63 (surf. 3) - 12.70 mm argon - Econover Select 63 (surf. 5) U-VALUE BTU/ HFT 2 - F R-VALUE H-FT 2 - F/BTU TRANSMITTANCE % VISIBLE LIGHT SOLAR TRANSM. UV TDW- ISO VISIBLE LIGHT REFLECTANCE % OUT IN SHA- DING COEF. SOLAR HEAT GAIN COEF. RELATIVE HEAT GAIN BTU/H- FT 2 0.445 2.2 80.1 65.7 71.0 14.9 14.8 0.84 0.73 175.5 0.445 2.2 18.6 21.8 12.6 36.7 19.0 0.36 0.31 77.6 0.254 3.9 17.8 13.7 11.6 36.5 15.6 0.24 0.20 50.2 0.445 2.2 27.0 19.0 18.4 37.3 27.0 0.32 0.28 70.8 0.254 3.9 25.8 13.4 17.0 36.9 23.0 0.23 0.20 48.2 0.359 2.8 18.1 12.5 19.0 31.2 26.7 0.24 0.21 52.6 0.252 4.0 17.3 10.2 16.9 31.1 22.7 0.19 0.16 41.0 0.128 7.8 15.1 7.7 13.8 31.2 22.6 0.15 0.13 31.5

MANUFACTURING SIZE Due to the wide selection of products available as well as the number of suppliers, maximum sizes may vary depending on the suppliers and demand. Minimum sizes may also vary depending on intended uses. That being said, the average maximum size of a glass sheet is approximately 96 inches X 144 inches (2,438 mm X 3,657 mm). Upon request, we can obtain glass sheets of 102 inches X 168 inches (2,590 mm X 4,267 mm). MAINTENANCE Once the reflective glass is installed, it is recommended that all exposed surfaces be cleaned, if needed, in order to preserve the esthetic qualities of the product. Rub gently with a soft cloth, using cold or warm water and non-aggressive chemicals for all glass surfaces. Caution should be exercised when choosing cleaners. Abrasive cleaners must never be used as they can cause damage to the glass surface. Several products are specifically designed to clean glass. Metallic objects should not be used because they could scratch the glass. Cleaners containing solvents must never be used. GLAZING REPLACEMENT To help us identify the insulated unit with reflective glass that needs to be replaced, we strongly recommend that you look at the spacer in the insulated unit. You will then know who was the original manufacturer of the unit as well as its year of manufacture. We also require the project name and location to conduct extensive research. In the case of tempered or heat-strengthened monolithic reflective glass, you should be able to see a laser-engraved logo in one of the corners of the glass, that is, if it is not covered. A date as well as the name of the company that tempered the glass should also be indicated. Multiver Logo - Tempered glass Slight glass colour variations can occur during the manufacturing process and result in a colour different from the original tint, in the event of a replacement. Exposed glass surfaces must be protected during the construction or renovation of the building to minimize the risk of scratches and glass breakage. 7/11

USEFUL INFORMATIONS Mirropane TM reflective glass is the perfect product for interrogation rooms as well as observation rooms. The ratio of illumination levels must be of at least 8 ( observed side) to 1 (observing side), and the mirror coating must be on the observed side (consult the Pilkington Mirropane Datasheet document). It is essential to always ensure the compatibility of sealants that are close to or in contact with Multiver products. Failure to comply with this instruction could result in the voiding of the Multiver warranty. Consult our documents on sealant compatibility to avoid potential problems with our products. In general, we recommend putting the reflective surface on position 2 of a doubleglazed insulated glass unit to avoid that the reflective surface deteriorate with time as a result of exposure to the weather (surface 1). The chosen glass thickness and tint as well as its level of reflection, the building s surroundings, the lighting and many other factors significantly influence the appearance of the selected colour. It is recommended to ask that samples be provided (see the Sample Request form) before making your final decision on reflective glass. To prevent thermal stress breakage and increase the safety factor, reflective glass can be heat-strengthened, tempered and/ or laminated. Reflective glass absorbs more heat than standard clear glass, thus increasing the risk of thermal stress breakage. A laser-engraved logo appears at one of the edges of all tempered and heat-strengthened glass products. Caution must however be exercised when tempering reflective glass as tempering causes distortions of the glass, which are far more visible with reflective glass due to its mirror quality. 8/11

ADVICE ON APPLICATIONS WITH LAMINATED GLASS Here are a few options we recommend : FOR ENHANCED ACOUSTIC PERFORMANCE : Reflective glass laminated with an acoustic polyvinyl butyral interlayer, commonly known as Saflex Q series acoustic PVB interlayer (see the Laminated Glass document), and laminated with another type of glass of your choice. Several layers can be laminated, offering virtually endless combination possibilities. TO INCREASE GLASS SAFETY FACTOR AND MECHANICAL STRENGTH : Reflective glass laminated to a PVB Du- Pont TM SentryGlas interlayer, and laminated with another type of glass. PVB SentryGlas is nearly 100 times stiffer and five times stronger than standard PVB. PURPOSE : Tinted balustrades, insulated glass units resistant to impacts, powerful wind gusts, gunfire, explosions, vandalism, falling broken glass, etc. Useful for protecting valuables against theft. Note that other combinations should be considered to meet your specific needs. PURPOSE : Reducing inside and outside noise opposite insulated glass units, glass partitions or even skylights. Glass of your choice Glass of your choice PVB Q Series PVB Sentry Glass Reflective glass Reflective glass 9/11

ADVICE ON APPLICATIONS WITH LAMINATED GLASS Here are a few options we recommend : FOR AN OPAQUE GLAZING OR ORIGINAL COLOURS : Reflective glass laminated to an opaque black or white PVB interlayer and/or a Saflex Vanceva colour PVB interlayer, and laminated with another type of glass of your choice. To discover the impressive range of colours we offer, go to Vanceva s Web site (www.vanceva.com). Once again, numerous combinations are possible. TO COMBINE WITH SELFCLEANING GLASS : Activ TM self-cleaning glass for indoor or outdoor use offered by Multiver laminated to a PVB interlayer and reflective glass. This will provide you with the desired light reflectance while minimizing glass maintenance. Activ TM self-cleaning glass also has recognized antibacterial properties. PURPOSE : For institutional, commercial or residential projects, for indoor and outdoor use, depending on your needs. PURPOSE : There is a whole variety of uses to choose from for both indoor and outdoor glazing designs that are anything but ordinary. Glass of your choice Glass of your choice PVB Vanceva PVB of your choice Reflective glass Activ TM self-cleaning gass 10/11

This document gives a general description of the product. For further information, please contact an authorized supplier of Multiver products. The use of any of the products mentioned here in is the sole responsibility of the users. Multiver assumes no responsibility for the use of its products.