Summation current transformers, type KSU/SUSK

Similar documents
Primary winding current transformer, type WSK

Data Sheet. Summation Current Transformer OMEGA SUMMATION CT : SIGMA SERIES. Page 1 of 5 00 / 1213

Data Sheet. Summation Current Transformer. RISH SUMMATION CT : RISH XMER Sigma. RISH XMER Sigma. Page 1 of 5 00 / 1213

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

Medium-voltage transfomers

Automatic synchronising relay

DATA SHEET. Voltmeters and Ammeters,

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DATA SHEET. Switchboard instruments,

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

W DATA SHEET Current Transformer 40 x 10, A

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Installation and start up instructions. Synchroniser type FAS-115DG uni-line H (UK) Synchronisation of generator to busbar

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

Installation and start up instructions. Synchroniser type FAS-113DG uni-line F (UK) Synchronisation of generator to busbar

RMV-122D, RMV-132D ANSI

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

Measuring current transformers of the W, W series

Installation and start up instructions. Paralleling relay type HAS-111DG uni-line G (UK) Synchronisation of generator to busbar

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

DEIF A/S. User s manual. Read synchroscope type RSQ-3. Precision LED synchronoscope. High immunity to harmonic distortion F (UK)

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

Measuring current transformers of the W AB(P) series

Content. 1. Dimensiong of CT s. 2. Error definitions. 3. General design aspects. 4. Linear cores. Certified acc. to ISO 9001/14001, SN EN 45001

Measuring current transformer for universal measuring devices

TCM-2 Thyristor Control Module DATA SHEET

MODEL AT-10 ANALOG TRANSMITTER

DEIF A/S. Insulation monitor. Type SIM-Q

Function. Adjustment. Extra functions included. Modes. Housing

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

HAWK5000 Operators Manual

Medium Voltage Products. KECA 80 C85 Indoor current sensor

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

Accessories. Accessories

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

Computer-14d - xx - 144a

KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

DEIF A/S. Application Notes. MDR-2 test procedures. Test of current measurement. Test of differential current measurement.

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

Installation and Operating Manual

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

SINEAX U 553 Transducer for AC Voltage

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

ENS31 Automatic Isolation Unit Product Description

RISH Ducer E13 3 channel transducer for AC current and voltage

T-Line, current transformers

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Enhanced Quality with a Touch of Style

Series P. Applications

50-SDMS-01 SPECIFICATIONS FOR

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

XP2-R Power and Reverse Power Relay

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

ENS26 Automatic Isolation Unit Product Description

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors for Cellpack separable connectors

EPSITRON Electronic Circuit Breakers Compact and Precise ECBs for DC Circuits

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Sensor Technology. Applications for medium voltage

PEM353. Universal measuring device

Protection relays and transformers

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

Spec Information. Reactances Per Unit Ohms

Electronic Circuit Protector ESX10-T

MINI-PS AC/24DC/1.3

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection

2C73 Setting Guide. High Impedance Differential Relay. Advanced Protection Devices. relay monitoring systems pty ltd

SLKK 5. Extract from the online catalog. Order No.:

RCTrms Technical Notes

DEIF A/S. Application note. Generators parallel with mains Multi-line 2 version 2. Application description. Power import control. Power export control

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Wind Direction Transmitter - compact - with serial output x0.x00

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Coriolis Massflowmeter

ISOMETER IRDH575. Approvals

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

INSTRUCTION MANUAL FOR VARIABLE PERCENTAGE DIFFERENTIAL RELAY BE1-87G

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

POWER QUALITY REPORT

MINI-PS AC/2X15DC/1

Transcription:

Technical documentation Summation transformers, type KSU/SUSK DEIF /S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921210113E

Data sheet Frequency Nominal Voltage Isolation Class Test Voltage Thermal Continuous Thermal Current Rated Short-Time Thermal Current Rated Dynamic Current Instrument Security Factor 50/60 Hz (16 2/3 to 400 Hz on request) 720 V C 1200 V C for SK 165.5, 205.5 E 3000 V, 1 min, 50 Hz (Nominal Voltage 720 V) 6000 V, 1 min, 50 Hz (Nominal Voltage 1200 V) Icth = 1.0 In Icth = 1.2 In for SK 165.5, 205.5 Ith = 40 In, 1 sec (max. 100 k) for WSK, KSU, SUSK Idyn = 2.5 Ith FS 5 to 15 (see product label for specific value) Operating Temperature -5 C to 50 C Storage Temperature -25 C to 70 C Standard References IEC / DIN EN 61869/1+2 DIN 42600/1+2 2 www.deif.com

www.deif.com 3

Current transformers overview Click on a product name or check mark to jump to information page. Page 5 6 7 8 9 10 11 12 Page nominal KSU 2 KSU 3 SUSK 3 SUSK 4 SUSK 5 SUSK 6 SUSK 7 SUSK 8 nominal 1 3 3 3 3 3 3 3 3 1 2.5 2.5 3 3 3 3 5 10 10 15 15 20 20 25 25 30 30 40 40 50 50 60 60 75 75 80 80 100 100 125 125 150 150 200 200 250 250 300 300 400 400 500 500 600 600 750 750 800 800 1000 1000 1200 1200 1250 1250 1500 1500 1600 1600 1800 1800 2000 2000 2500 2500 3000 3000 3200 3200 4000 4000 5000 5000 6000 6000 7500 7500 conductor in mm Round conductor in mm Transform. width in mm 57 57 65 65 65 65 65 65 * For the transformers above, click-on mountings are available for fitment onto 35mm DIN-rails (DIN 50022). conductor in mm Round conductor in mm Transform. width in mm 4 www.deif.com

Guidance when ordering summation transformers Summation transformers are suitable for the summation of several synchronized alternating s with similar phases but with differing load phase shifts. It is also possible to have the summation of s with varied nominal voltages of similar phase positions. These measurements cannot be used for tariff applications, as the existing voltage differences are recorded as errors. With the counter connection of the main transformer to the summation transformer, it is possible to receive secondary s which are proportional to the differences of the primary input s. The built-in technical know-how enables the summation transformers to add secondary s of varying nominal transmissions from the main transformer. The secondary connections of each main transformer are connected to the allocated primary inputs of the summation transformers. The number of windings of individual partially wound primary circuits of the summation transformer is pro portionally aligned to the ratio of the primary nominal of the corresponding main transformer, and to the sum of the nominal s of all the summation transformers being connected to the main transformer. For the visual display of the, a measuring unit can be used with a measuring range similar to the secondary nominal of the summation transformers. It is irrelevant for the main transformers with similar nominal transmission ratios, to which primary circuit of the summation transformer the connection is made. With main transformers of different nominal transmission ratios, care must be taken to adhere to the assigned connection to the terminals of the summation transformers. Is the flow in the main transformer interrupted, the secondary circuit of the main transformer must neither be short-circuited nor be connected to the summation transformer, or to the main transformer. Summation transformers with unallocated primary circuits must remain open for a later connection to an additional main transformer. The secondary output of the summation transformer is in this instance lower than the secondary nominal of the summation transformer by a quantity equal to the ratio of the primary nominal of this missing main transformer and the sum of all the primary nominal s of the main transformer. The nominal secondary of a main transformer must be equal to the nominal primary of the input allocation of the summation transformer. www.deif.com 5

Guidance when ordering summation transformers Please find below an example for the correct selection of measuring components for summation transformers. Example: ctual situation: 3 transmission ratios 1000 / 5 V 800 / 5 V 600 / 5 V Overall 2400 / 5 V Burden: Looking for: 1 meter 1 power recorder 1 summation transformer and the V power of an individual main transformer Required active performance of the summation transformer: Current meter Performance recorder Measurement conductor loss consumption Po summation ct Interim result 1.5 V 7.0 V 1.5 V 4.0 V 14.0 V The individual transformer must provide it s V share from this 14.0 V corresponding to its ratio to the total transmission. Consideration must also be given to the respective power loss between the main transformer and the summation transformer plus other possible losses. 1. Main transformer 1000 / 5 1000 14.0 = 5.83 V + additional possible losses 2400 2. Main transformer 800 / 5 800 14.0 = 4.67 V + additional possible losses 2400 3. Main transformer 600 / 5 600 14.0 = 3.50 V + additional possible losses 2400 The V values of the main transformers are to be rounded up to the corresponding V values in our charts. The ratio of the primary of a main transformer to the sum of the primary s of all main transformers the ratio must not exceed 1:8. Important indication to the power measuring Too many rising deviation can prevent the measuring transformer acting as a transformer from fulfilling its protective function with regard to the connected measuring units, as in normal operation its functions is well below its saturation limit, and in the event of over s, the saturation limit is reached considerably later and takes the function almost as a protection transformer. If there is too much of a decrease, the measuring transformer, as a result of the continuous excess demands will reach the saturation limit too soon and indirectly function as a switch, rendering a measuring impossible. 6 www.deif.com

Summation transformer KSU 2 Secondary 5 1 2 1+1 2 5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 20 3 3 25 3 3 1 20 3 3 5 7.0 (2.2 4 ) 5 5.0 (2.1 6 ) 7 2.0 (2.8 3 ) 8 7.0 (3.4 2 ) 1 2 7.0 (5.0 0 ) k l K L 9 3.5 (3.6 8 ) 9 0.0 (3.5 4 ) B K C K 2 9.8 (1.1 7 ) 1 9.4 (0.7 6 ) xxx xx xxxxx xxx xxx xxx xxx 5 0.0 (1.9 6 ) 8 0.0 (3.1 5 ) Connection example for different ratios K-L = 1000/5 BK-BL = 800/5 CK-CL = 600/5 0.300-1.100kg (0.66-2.43lbs) : 59041 (x2) www.deif.com 7

Summation transformer KSU 3 Secondary 5 1 3 1+1+1 3 5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 1 5 7.0 (2.2 4 ) 5 5.0 (2.1 6 ) 7 2.0 (2.8 3 ) 8 7.0 (3.4 2 ) 1 2 7.0 (5.0 0 ) k l K L 9 3.5 (3.6 8 ) 9 0.0 (3.5 4 ) B K C K 2 9.8 (1.1 7 ) 1 9.4 (0.7 6 ) xxx xx xxxxx xxx xxx xxx xxx 5 0.0 (1.9 6 ) 8 0.0 (3.1 5 ) Connection example for different ratios K-L = 1000/5 BK-BL = 800/5 CK-CL = 600/5 0.300-0.750kg (0.66-1.65lbs) : 59041 (x2) 8 www.deif.com

Summation transformer SUSK 3 Secondary 5 1 3 1+1+1 3 5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 1 6 5.0 (2.5 5 ) 6 0.0 (2.3 6 ) K I L E L F L 140.0 (5.51) 136.5 (5.37) D L G L H L 5 4.0 (2.1 2 ) xxxxx xx xxxx xxx xxx xxx 9 5.0 (3.7 4 ) 122.0 (4.80) 156.0 (6.14) 0.480-1.130kg (1.06-2.49lbs) : 59041 (x2) : 59042 www.deif.com 9

Summation transformer SUSK 4 Secondary 5 1 4 1+1+1+1 4 5+5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 25 3 3 1 25 3 3 6 5.0 (2.5 5 ) 6 0.0 (2.3 6 ) K I L E L F L 140.0 (5.51) 136.5 (5.37) D L G L H L 5 4.0 (2.1 2 ) xxxxx xx xxxx xxx xxx xxx 9 5.0 (3.7 4 ) 122.0 (4.80) 156.0 (6.14) 0.500-1.210kg (1.10-2.67lbs) : 59041 (x2) : 59042 10 www.deif.com

Summation transformer SUSK 5 Secondary 5 1 5 1+1+1+1+1 5 5+5+5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 1 6 5.0 (2.5 5 ) 6 0.0 (2.3 6 ) K I L E L F L 140.0 (5.51) 136.5 (5.37) D L G L H L 5 4.0 (2.1 2 ) xxxxx xx xxxx xxx xxx xxx 9 5.0 (3.7 4 ) 122.0 (4.80) 156.0 (6.14) 0.500-1.240kg (1.10-2.73lbs) : 59041 (x2) : 59042 www.deif.com 11

Summation transformer SUSK 6 Secondary 5 1 6 1+1+1+1+1+1 6 5+5+5+5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 1 6 5.0 (2.5 5 ) 6 0.0 (2.3 6 ) K I L E L F L 140.0 (5.51) 136.5 (5.37) D L G L H L 5 4.0 (2.1 2 ) xxxxx xx xxxx xxx xxx xxx 9 5.0 (3.7 4 ) 122.0 (4.80) 156.0 (6.14) 0.500-1.250kg (1.10-2.76lbs) : 59041 (x2) : 59042 12 www.deif.com

Summation transformer SUSK 7 Secondary 5 1 7 1+1+1+1+1+1+1 7 5+5+5+5+5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 1 6 5.0 (2.5 5 ) 6 0.0 (2.3 6 ) K I L E L F L 140.0 (5.51) 136.5 (5.37) D L G L H L 5 4.0 (2.1 2 ) xxxxx xx xxxx xxx xxx xxx 9 5.0 (3.7 4 ) 122.0 (4.80) 156.0 (6.14) 0.500-1.200kg (1.10-2.65lbs) : 59041 (x2) : 59042 www.deif.com 13

Summation transformer SUSK 8 Secondary 5 1 8 1+1+1+1+1+1+1+1 8 5+5+5+5+5+5+5+5 ccuracy class ccuracy class V rt.-no. rt.-no. rt.-no. rt.-no. 1 1 6 5.0 (2.5 5 ) 6 0.0 (2.3 6 ) K I L E L F L 140.0 (5.51) 136.5 (5.37) D L G L H L 5 4.0 (2.1 2 ) xxxxx xx xxxx xxx xxx xxx 9 5.0 (3.7 4 ) 122.0 (4.80) 156.0 (6.14) 0.710-1.280kg (1.57-2.82lbs) : 59041 (x2) : 59042 14 www.deif.com

Current transformers ccessories for DCT Test certificate On request, we can provide you with a test certificate for a specific transformer along with the CT. Please inform us when placing your order. On request, we can supply a transparent plastic cover. The cover seals the connections on the CT in a way that leaves the type label visible. Please check availability on each individual data sheet. Excitation curve On request, we can provide you with an excitation curve for a specific transformer along with the CT. Please inform us when placing your order. Optional frequency Frequency range for a standard CT is 50-60Hz. On request, we can provide you with a frequency range from 16 2/3 400Hz. Please inform us when placing your order. Cast resin Cast resin is standard for all CT s with a nominal >4,000. On request, all CT s with a nominal <4,000 can be produced with cast resin. Please inform us when placing your order. The min. and max. weight specification for each type refers to standard versions. The specification is different if cast resin is ordered for CT s <4,000. Mounting Foot angle for screw mounting and busbar mounting screws with isolating protection caps are supplied along with the CT. DIN-rail mounting for tubes, plug-ins and protection transformers is available on request for certain CT types. Please check availability on each individual data sheet. www.deif.com 15