Operations and Instruction Manual G-Lok Anchorage - Model #????? Portable Concrete and Steel Anchorage Connector ANSI Z359.

Similar documents
Large Diameter Tapcon

Elo Touch Solutions Wallmounting Kit for the 7001L IDS Touchmonitors

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

SECTION 7. SAFETYING

USER S MANUAL. Horizontal inclinometer system Model TES-AN-25H

INFUSIONS and METALWORKS Wings Accent and Acoustical Clouds

METALWORKS Wings Accent and Acoustical Clouds Installation Instructions

Supports up to 100 lbs / 45 kg

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

3 Emergency Breakaway Coupling

Mount to the Wall INSTALLATION MANUAL

RATCHET CABLE CUTTER

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Installation Guide [OPTION B] MODEL # PRM4X8 Patent Pending

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

Tube Facing Tool.

Multi-Set II Drop-In Anchors

Universal Projector Ceiling Mount Model: DPM-45

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Hang-TITE Rod Hanger Screws

ROTARY HAMMER OWNER S MANUAL

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

NX7 SERIES 5-1/2 HANDRAIL

Hollo Set Drop-In Anchors

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

Dual Arm Tilt LCD Mount

HBS-AP ASSEMBLING INSTRUCTIONS

Wall mounting bracket

ELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs)

Umbrella Inserts and Stubby Screens

18000 HDL FOUR POST LIFT LB CAPACITY INSTALLATION AND OWNER'S MANUAL

TO O L K IT. Public Bike Repair

Umbrella Inserts and Stubby Screens

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Option B

METAL BLINDS. Deluxe GETTING STARTED OPTIONAL HARDWARE. A few simple tools are required: STANDARD HARDWARE

LENGTH IDENTIFICATION

southpaw enterprises, inc.

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Installing flat panels on the MPL15 wall mount

FLOOR ANCHOR SYSTEM APPLICATIONS L TRACK APPLICATIONS

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Original Gallery System

CMA-455 Suspended Ceiling-Tile Reinforcing Kit

HP 2 SERIES Integral Driver - Solid State LED

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

ASSEMBLY GUIDE. Mia Narrow Bookcase

Installation and Assembly: Full Service Video Wall Mount

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Option A

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Standard Specifications

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

ROTARY HAMMER OWNER'S MANUAL

7141 & NATIONAL POLE VAULT STANDARDS SPECIFICATIONS

SLIDING DOORS DIRECT ROLLER

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Frequently Asked Questions

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

ALUMINUM AIR TRIM INSTALLATION INTRODUCTION

Pow-R-Feed Systems Service Manual

Page 1. SureMotion Quick-Start Guide: LACPACC_QS 1st Edition - Revision A 03/15/16

e997 Articulating Wall Arm MANUAL IM004-03

Wall mounting bracket

Frequently Asked Questions

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

Louvolite SC32 Series Roller Blind

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

EKX Full-Range Loudspeaker Accessories

M-RAIL Sismet Road, Mississauga, L4W 1V6 TEST REPORT FOR MLEVEL GUARD SYSTEMS

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

MM750 Installation Instructions

ATI Evaluation Service A Division of Architectural Testing Certification Services

2-1/2" 16 gauge Straight Finish Nailer Includes: 2 Allen wrenches & pneumatic tool oil

Letter of Transmittal/Submittal

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

BOTHWELL ALUMINUM PLANK AND DECK SYSTEM USERS MANUAL AND GUIDELINES

Side Winder R o u t e r L i f t.

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

7 X 10 X 6 SHELTER 7 X 16 X 6 SHELTER 12 X 10 X 6 SHELTER 12 X 16 X 6 SHELTER

8" BENCH SHEAR INSTRUCTIONS. Item #20198

ATLANTIS RAIL HandiSwage Installation Instructions ATLANTIS RAIL Contact Information Atlantis Rail Systems November, 2013

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Keep this Operations manual with the Zip Rail at all times. New users are required to read it before installing and using the Zip Rail system.

Installa on Guide: Fence Distributors. YourNextFence.com

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

SECTION 10. SAFETY METHODS FOR TURNBUCKLES

Quick Set Dovetail Jig

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

ET-PKL100S. Installation Instructions. Ceiling Mount Bracket (for Low Ceilings) Model No.

ALLIGATOR All-Purpose Anchors

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

Complete line of Holemaking Products and Accessories

Curium 19H Installation Instructions & Parts List

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

MODEL No: GSS3030G. Model No:...GSS3030G Overall Size (W x D X H*) x 3000 x 2100mm Roof Type:...Gable *Minimum Wall Height

Installation and Assembly: Universal Projector Wall Arm

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Face Mount to Through-the-Post Mount

Transcription:

TM Operations and Instruction Manual G-Lok Anchorage - Model #????? Portable Concrete and Steel Anchorage Connector ANSI Z359.1 5,000 lbs / 22kn Made in the USA 3/4 Fall Protection G-Lok s are to be used in concrete or steel, DO NOT use in wood or any other substrate. This product is used in precast concrete only with a compressive strength of at least 5,000 PSI Main Cable 7x19 Aircraft Cable Ball Shank Stainless Steel Toggle Bar Stainless Steel Hole Plug 6061 T6 aluminum Spring Zinc Coated Stainless Steel Swage Zinc Coated Copper Return Wire 1x19 Aircraft Cable Anchor Loop Polyurethane Use For Fall Protection Only!! Works in 6 Hollowcore or bigger Works from 1-1/2 to 4 thick precast concrete Works from 1/4 to 4 thick steel flange G-Lok s can be placed in: * Horizontal surfaces * Vertical surfaces * Overhead / ceiling surfaces G-Lok Part Description 3/4 G-Lok Tested - ANSI Z359.1 Strength - 5,000 lbs / 22kn Model - RTL #??? Color Coded in Bright Yellow Tubing Anchor Loop Swage Company Logo Spring ANSI Z359.1 Mark Manufactured Date Compliance: ANSI Z359.1 5,000 lbs. Model # / Batch 000 Manufactured 00/00/00 Batch Number Model Number Main Cable US Patent Pending Patent Markings Cap Hole Diameter/Size 1 Activator Cable Made in the USA Hole Diameter/Size 1 Warning Instructions Do Not use in wet or uncured concrete. Use in precast concrete only with a compressive strength of at least 5,000 PSI. Use for fall Hole Plug Warning: All persons using this equipment must read, understand and follow all instructions. Failure to do so may result in serious injury or death. Toggle Bar Ball Shank

Activating the Toggle Bar Set the Toggle Bar in the insertion position ( See Dia. A ) Place your thumb on the Cap of the Activator Cable. Push the unit through the hole while pressing on the Cap. As the unit passes through the hole, the Toggle Bar will flip to the open position. ( Dia. B ) Shows the Toggle Bar open position. Insertion position Open position Thumb on Activator Cap while inserting Thumb pushing on Activator Cap forcing the Toggle Bar into open position Dia. A Dia. B 2

General Instructions and Care Important Warnings!! This product is to be used by qualified fall protection personnel only. It is to be anchored in accordance with manufacturer s requirements. All persons using this equipment must read and understand all instructions. Failure to do so may result in serious injury or death. If a fall occurs, the G-Lok must be disposed of according to the manufacturer instructions. Users should be familiar with regulations governing this equipment. All individuals who use this product must be correctly instructed before using this device. Use only compatible connectors with any G-Lok. Refer to separate instructions supplied with your connecting device. This product is designed for use in thin wall or hollow core precast concrete and steel flanges. Keep unit free of grout, grease, oils, dirt or other contaminates. This could effect the performance of the unit. When using a G-Lok make sure the Toggle Bar is activated in the open position ( See page 2 ). Inspection: Make sure unit is straight and operates smoothly. Make sure cable is not kinked, frayed or damaged. Make sure metal components are not damaged. Make sure toggle bar opens freely. Make sure the hole plug slides freely along main cable. Make sure the label is affixed to unit. When reusing a previously drilled hole, always inspect the hole carefully. Storage and Cleaning: After each use clean with compressed air. Store in clean dry environment. Store in secure area at the end of each work day. Do not pile objects unto or step on the unit. Keep unit free of grout, grease, oils and dirt or other contaminates. Never lend your unit to other workers. Disposal: Dispose of unit after any fall has occurred. Dispose of unit if cable becomes kinked or bent. Proper disposal requires the units main cable to be cut. Follow all manufacturer s instructions. Use only compatible connectors. Always inspect your units prior to use. Use the proper method of coupling to anchorage. Remove unit from service if a fall has occurred. Patch all holes with concrete when job is complete. For use by Single User only. Pregnant women and minors must not use this product. Designed safe working load is 400 LBS (149.3 kg). Do not exceed this weight. 3

Instructions For Use In Concrete Use For Fall Protection Only!! Drill a 3/4 diameter hole. Drill hole in the center of core hollow. Never drill hole closer than 6 to any edge or corner. Always inspect a previously drilled hole for deformation. Drill another proper hole if needed. Inspect the unit for damage each time you use it. If damage has occurred, dispose of unit. Make sure the Toggle Bar is activated in the open position. The Hole Plug must be seated in the concrete hole. Never rely on a unit placed by unqualified workers. Remove your unit at the end of each day. Do not use this product in uncured/wet concrete. The precast concrete must have a compressive strength of at least 5,000 PSI and the core wall must be 1-1/2 thick. ( See Dia. On next page ) Do not drill a hole closer then 6 from any corner or edge. Drill a straight 3/4 diameter hole all the way through the core center utilizing a rotary hammer drill and industrial grade SDS bit. Only use industrial grade rotary hammer drills and drill bits. DO NOT USE masonry drill bits. SEE DIAGRAMS ON NEXT PAGE!! 4

Placement in Concrete Unit in insertion position. Unit inserted. Push the unit downwards until the Spring fully compresses. pushing on Activator Cap will force the Toggle Bar into open Position. Removal Only when the unit is activated in the open position is it safe for load bearing. Grab the Hole Plug with one hand while pushing downward on the Anchor Loop with the other hand. Once the Hole Plug fully compresses the Spring the unit will be in the insertion position and ready to pull out. The Toggle Bar must be in this parallel position when inserting and removing the unit. 5

Instructions For Use In Steel Use For Fall Protection Only!! Drill a 3/4 diameter hole. Drill hole in the center of core hollow. Drill center of hole at least 1-1/2 from any edge or corner. Always inspect a previously drilled hole, make sure the hole is round and a true 3/4 diameter hole. Inspect the unit for damage each time you use it. If damage has occurred, dispose of unit. Make sure the Toggle Bar is activated in the open position. The Hole Plug must be seated in the steel hole. Never rely on a unit placed by unqualified workers. Never leave a unit inserted in a hole overnight. This product is to be used by qualified fall protection personnel only. It is to be anchored in accordance with manufacturer s requirements. The steel flange must be at least 1/4 thick and you must drill the center of the hole at least 1-1/2 from any edge or corner. It is important that you drill your G-Lok hole to the manufacturer s required diameter. All holes must be drilled to a 3/4 diameter. Do not use holes larger than 3/4 or holes that are not round in shape. NEVER USE A BENT DRILL BIT!! SEE DIAGRAMS ON NEXT PAGE!! 6

Placement in Steel Unit in insertion position. The center of the hole must be drilled at least 1-1/2 from any edge. Push the unit downward until the Spring fully compresses. Pushing on Activator Cap will force the Toggle Bar into open position. Only when the unit is activated in the open position is it safe for load bearing. See page 5 for removal techniques. 7

Address Here 8