Similar documents
TRC ELECTRONICS, INC

LPS TRC ELECTRONICS, INC

DRC-100 series. 100W Single Output with Battery Charger (UPS Function) File Name:DRC-100-SPEC Sicherheit ID

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

LPS. DRC-60 SERIES 60 Watt Battery Charger Power Supply Measures: 3.94 x 3.54 x 1.57 (866) MEAN WELL

R S P series

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

Power Supply PSU05-045

DRC-40 series LPS. 40W Single Output with Battery Charger (UPS Function) File Name:DRC-40-SPEC Sicherheit ID

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

50W Single Output Switching Power Supply

800W Single Output Power Supply

MODEL CLG CLG CLG CLG CLG CLG CLG V 18 ~ 24V 20V 15 ~ 20V

PSU s e r i es

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable

60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W

24V 40A 0 ~ 40A 960W. 150mVp-p 20 ~ 26.4V 83% 85% 88% 88% 90%

2000W Front End Power Supply

80W Single Output Switching Power Supply

Features : 15V 50A 0 ~ 50A. 750W 150mVp-p. 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.

IP65 IP mVp-p. 150mVp-p 17 ~ 22V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable 5 ~ 10A 3 ~ 6A 1.0% 2.5 ~ 5A 1.

E E E E E E E E E E E E IP65 IP67

IP65 IP mVp-p 13.5 ~ 17V. 150mVp-p 17 ~ 22V 22 ~ 27V 4.65 ~ 9.3A 1.0% 3.9 ~ 7.8A 1.0%

E E E E E E E E E E E E E E E

E E E E E E E E E E E E E IP65 IP67. 24V 30V 36V 42V 4.8A 4A 3.2A 2.65A 2.28A 96W 96W 96W 95.4W 95.76W 96W 150mVp-p 22 ~ 27V.

E E E E E E E E E E E E E E

HLG-185H-12 HLG-185H-15 HLG-185H-20 HLG-185H-24 HLG-185H-30 HLG-185H-36 HLG-185H-42 HLG-185H-48 36V 18 ~ 36V 13A 11.5A 9.3A 7.8A 6.2A 5.2A 4.4A 3.

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

IP64 HLN-40H-12 HLN-40H-15 HLN-40H-20 HLN-40H-24 HLN-40H-30 HLN-40H-36 HLN-40H-42 HLN-40H-48 HLN-40H-54 12V 20V 12 ~ 20V

HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

PF 0.96/230VAC PF 0.96/115VAC at full load and rated output voltage PF 0.9 at 60 ~ 100% load INPUT EFFICIENCY (Typ.)

IP64 36V 21.6 ~ 36V 4A 3A 2.5A 2A 1.7A 1.45A 1.3A 24V 14.4 ~ 24V 30V 18 ~ 30V. 60W 60W 60W 60W 61.2W 60.9W 62.4W 150mVp-p 17 ~ 22V.

2000W Front End Power Supply

RCP DC VOLTAGE 48V RATED CURRENT 42A CURRENT RANGE 0 ~ 100A 0 ~ 80A 0 ~ 42A RATED POWER. 2016W RIPPLE & NOISE (max.) Note.2 150mVp-p.

HLG HLG HLG HLG HLG HLG HLG HLG HLG

Features : 36V. Can be adjusted by internal potentiometer A type only 6 ~ 10A 4.0 ~ 6.7A 3 ~ 5A ±2.0% ±0.5%

42V 21 ~ 42V 4.8A 4A 3.2A 2.65A 2.28A 30V 15 ~ 30V. 200mVp-p 27 ~ 33V. Can be adjusted by internal potential meter or through output cable

E E E E E E E E E E E IP65 IP67 HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 12V

HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V

SELV. 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed

24V 14.4 ~ 24V 20V 12 ~ 20V. 48V 28.8 ~ 48V 3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.96A 0.84A 39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W 40.

IP65 IP67 264W 285W 300W W 321W 320.4W 321.3W 321.6W

240W Single Output Switching Power Supply SELV

10000W Single Output Power Supply. Features. Applications. Description. Model Encoding RST

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT

36V 21.6 ~ 36V 5A 5A 4A 3.4A 2.7A 2.3A 1.95A 1.7A 24V 14.4 ~ 24V 20V 12 ~ 20V. 60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 150mVp-p.

H L G -150H s er i es

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

SPECIFICATIONS. Input Output Approvals

300W Railway Single Output DC-DC Converter

HLN-40H SERIES 40 Watt LED Power Supply Measures: 6.34 x 2.42 x 1.38

Features : IP65 IP67 SELV

Specifications 2016-V AC-DC Switching Mode Power Supply NK-200 Series, 200W

E E E E E E E E E E E IP65 IP67

HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54 36V 21.6 ~ 36V 5A 5A 4A 3.4A 2.7A 2.3A 1.95A 1.

185W Single Output Switching Power Supply IP65 IP67

HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42 HLG-240H-48 12V 36V 18 ~ 36V 16A 15A 12A 10A 8A 6.7A 5.

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

SYNRAD PS DC Power Supply (Meanwell RSP )

IP65 IP67 42V 5A 4.8A 4A 3.2A 2.65A 2.28A 2A. 150mVp-p. 200mVp-p 27 ~ 33V 22 ~ 27V. Can be adjusted by internal potentiometer or through output cable

RCP-1600 series. 1600W Rack Mountable Front End Rectifier. File Name:RCP-1600-SPEC Sicherheit ID

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 3000W MEAN WELL RSP-3000 Series

IP65 IP mVp-p 13.5 ~ 17V

IP65 IP67. 54V CONSTANT CURRENT REGION Note.4 10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V RATED CURRENT RATED POWER

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

IP65 IP67. ±5% 0.5Vp-p. 750ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load

24V 30V 60W 60W 60W 60W 61.2W 60.9W 62.4W 62.1W

60W Single Output Switching Power Supply

Features : IP65 IP67 SELV

RSP-3000 series. 3000W Power Supply with Single Output. File Name:RSP-3000-SPEC Sicherheit ID

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Power Supply for LEDs 320 Watt 15 Volt, Waterproof, Single Output

DRP-3200 series. 3200W Rack Mountable Front End Rectifier. File Name:DRP-3200-SPEC Sicherheit ID

RSP-2400 series. 2400W Power Supply with Single Output. File Name:RSP-2400-SPEC Sicherheit ID

RSD-30 series. 30W Reliable Railway DC-DC Converter. (reinforced isolation) File Name:RSD-30-SPEC

IP65 IP67. Can be adjusted by internal potentiometer A type only. 500ms, 80ms / 347VAC / 480VAC at 95% load 180 ~ 528VAC 254VDC ~ 747VDC 47 ~ 63Hz

TRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 2400W MEAN WELL RSP-2400 Series

IP65 IP67 HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 12V 15V 20V 24V 30V 36V 42V 48V

24V 30V 90% 90% 90.5% 90.5% COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC

HLG-60H-15 HLG-60H-20 HLG-60H-24 HLG-60H-30 HLG-60H-36 HLG-60H-42 HLG-60H-48 HLG-60H-54 DC VOLTAGE CONSTANT CURRENT REGION Note.

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

RST-5000 series. 5000W Power Supply with Single Output. File Name:RST-5000-SPEC Sicherheit ID

Waterproof Power Supply for LEDs 240 Watt 24 Volt, Single Output with PFC

IP65 IP67 6.2A. Can be adjusted by internal potentiometer A type only

3000W Single Output Power Supply

RSP-1500 series. 1500W Single Output Power Supply

IP65 IP67. Can be adjusted by internal potentiometer A type only

150W Single Output Switching Power Supply IP65 IP67

HLG-150H SERIES 150 Watt LED Power Supply

HVG-65 SERIES 65 Watt LED Power Supply Measures: 7.44 x 4.42 x 1.45

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

ELG-100 series. 100W Single Output Switching Power Supply IP67 IP65. File Name:ELG-100-SPEC

120W Single Output Switching Power Supply IP65 IP67

RCP-2000 series. 2000W Rack Mountable Front End Rectifier. File Name:RCP-2000-SPEC Sicherheit ID

OWA-60U series IP67. 60W Single Output Moistureproof Adaptor. File Name:OWA-60U-SPEC

RSP-1000 series. 1000W Power Supply with Single Output. File Name:RSP-1000-SPEC Sicherheit ID

RST series W Power Supply with Single Output. File Name:RST SPEC Sicherheit ID

Transcription:

www.tier1automation.com

DIN Rail Power Supplies www.tier1automation.com Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality products with superior service. This is the Altech Commitment! In response to a growing market for high power regulated Power Supplies, Altech introduced the new Din Rail mountable power supply line. They are reliable, cost effective, space economical and easy to install and maintain. They are able to handle any industrial process requirement. In addition, you do not need to oversize them; they are designed to work on % load capacity. The universal input, power factor correction and many approvals proves that Altech Power Supplies will function worldwide on a wide variety of applications. Wide operation temperature range, high efficiency and many protections make Altech Power supplies your best choice. Our well trained technical experts welcome the opportunity to answer your technical questions and provide solutions to your automation and control needs. Give us a call or visit www.altechcorp.com. Quality Commitment

DIN Rail Power Supplies Selection Guide 4-5 PSC Compact Class Series Compact Design and Lightweight Class, UL 1310 Recognized Brown-out protection 10W to 480W rated power Universal single phase input 6-35 PSA Flex Series (1 Phase) Flex power, solid metal housing UL 508 listed 10W to 600W rated power High efficiency with Boost Power Single phase input 36-47 PSB Flex Series ( & 3 Phase) Flex power, solid metal housing UL 508 listed 10W to 600W rated power High efficiency with Boost Power Two and Three phase input 48-57 PS-S Slim line Series Slim Line Design, plastic housing UL 508 listed contact 10W to W rated power Universal single phase input 58-71 PS Low Profile Series Low profile Design, plastic housing UL 60950-1 Recognized Isolation Class II 10W to W rated power Universal single phase input 7-85 PS Industrial Series Robust Metal housing UL 508 listed Built in active PFC function 75W to 960W rated power Single and three phase universal input 86-111 PS-C and W Series Narrow design, small metal housing UL 508 listed 150% pick load capacity 10W to 480W rated power Single and two phase wide input 11-133 CBI DC UPS System Fully automated battery care module Three charging modes 1, 4, 36 and 48V DC single outputs 110-30-77 / 30-0-500VAC input System start from battery function 134-155 CB Battery Chargers Intelligent battery chargers Suitable for most common battery types Adjustable charging current VDC and 4VDC single output 110-0-77 VAC input 155-189 Accessories Redundancy diode module UPS controller module Battery holders and enclosures Ultra capacitor modules 1-199 FAQ Index Terms & Conditions 3

PS Low Profile PS-S Slimine PSA & PSB Flex PSC Class Compact SINGLE PHASE SINGLE PHASE TWO (THREE) PHASE SINGLE PHASE Cat. No. PSC-10xx PSC-0xx PSC-xx PSC-60xx PSC-96xx PSC-151xx PSC-41xx PSC-481xx PSC-RM0 PSA-10xx PSA-180xx PSA-360xx PSA-600xx PSB-10xx PSB-180xx PSB-360xx PSB-600xx PS-S10xx PS-S0xx PS-Sxx PS-S60xx PS-Sxx PS-15xx PS-30xx PS-45xx PS-60xx PS-xx Selection Guide Choose your product from a wide range of features and options, suitable for almost all applications. Rated Current VDC 5 1 15 4 48 0.84A 0.67A 0.4A 1.7A 1.4A 1A 3.4A.7A 1.7A 0.85A 4A 5A.5A 1.5A 7.5A 6.4A 4A A 6.3A 3.A 10A 5A 0A 10A 0A 5A 7.5A 14A 5A 5A 7.5A 14A 5A A 0.84A 0.67A 0.4A 3A 1.67A 1.34A 1 6A 3.33A 1.7A 0.83A 10A 5A.5A 1.5A 7.5A 4A A.4A 1.5A 1A 0.63A 3A A A 1.5A 5A 3.5A.8A A 6.5A 4.5A 4A.5A 7.5A 6.5A 4.A Universal Input Switch Select Input Parallel Option UL 508 Listed UL 60950-1 Rec. UL 1310 Rec. EN 60950-1 NEC Class Compliant Short Circuit Overload Over Voltage Over Temperature CB 4

Selection Guide Choose your product from a wide range of features and options, suitable for almost all applications. PS Industrial SINGLE PHASE THREE PHASE Cat. No. PS-75xx PS-10xx PSH-10xx PSP-xx PSP-480xx PSP-480Sxx PST-xx PST-480xx PST-960xx VDC PST-960Pxx Output Voltage 5 1 15 4 48 6.3A 3.A 1.6A 10A 5A.5A 5A.5A 10A 5A 0A 10A 0A 10A 10A 5A 0A 10A A 0A A 0A Universal Input Switch Select Input Parallel Option UL 508 Listed UL 60950-1 Rec. UL 1310 Rec. EN 60950-1 NEC Class Compliant Short Circuit Overload Over Voltage Over Temperature CB Compact Housing SINGLE PHASE WIDE VOLTAGE PS-C10xx PS-Cxx PSH-C480xx PSP-C480Pxx PSW-10xx PSW-xx PSW-480Pxx 10A 5A.5A 10A 5A 0A 10A 0A 10A 10A 5A.5A 10A 5A 0 10 CBI1xx 3-5A DC-UPS CBI4xx CBI48xx CBI80 xx 3-0A 5-10A 1V/15A 4V/10A 36V/7A 48V/5A MULTI-VOLTAGE MULTI-VOLTAGE Battery Charger CB1xx 3-35A CB4xx 3-0A CB145A 6 A 5 A Acces. PS-RDN 1-8V PS-UPS 1-8V Three Phase Input Selected items, see data sheet 0V INPUT ONLY Special order item / not UL approved. Wide Range Input signal 5

Compact Single Phase Power Supply (PSC) ALTECH s Compact DIN rail switching power supply, PSC Series designed for the fast growing demand of DIN rail applications. These 10W to 480W models are enclosed with fully isolated plastic or metal case to prevent users from hazardous shock. The design complies with the compact requirements that the precious space on the industrial rail can be preserved effectively. Featuring up to 94% of efficiency, this series is cooled only by free air convection up to 70 C that significantly increase the reliability and lifetime of the power supply. Another important feature of PSC Series is its low power consumption (<0.75W) This unique characteristic can significantly expand the application of PSC series beyond just heavy industrial field, but can also be implied to dotcom or IT applications that require green power to save the energy and to obey the anticipated government laws in the near future! Short circuit protection, overload protection, over voltage protection, and the signal for monitoring the status of power supply are standard functions for the PSC Series. Typical applications include factory automation, process control, electro-mechanical industry, dotcom and IT. Input voltage range: AC inrush current (max): Cold start: DC adjustment range: Overload protection: Over-voltage protection: Other protection: Setup, rise, time (max): Withstand voltage: Working temperature: Safety standards: EMC standards: Military Standard Vibration On/Off 85-64V AC; 10-370V DC 0A at 115V AC; A at 30V AC ±10% rated output voltage 105% rated output power 115%-150% rated output voltage Brown out protection 500ms, 30ms/30V AC 0ms, 30ms/115V AC, at full load I/P-O/P: 3KV AC, I/P-FG:1.5KV AC, O/P-FG:0.5KV AC -0 to +70 C (-4 to +158 F), refer to output de-rating curve UL508 listed, UL1310 recognized, TUV approved EN60950-1 compliant EN550 class B EN60-4-,3,4,5,6,8,11 ENV5004; EN5504; EN60-6-1; EN6104-3; Light Industry Level criteria A MIL-HDBK-17F withstands G test Built in remote ON/OFF function (metal case only) 6

Compact Single Phase Power Supply (PSC) Features: Universal AC input/full range Protections: Short circuit / Overload / Overvoltage Cooling by free air convection DIN rail mountable UL1310 NEC class / LPS compliant (1V,4V,48V only) No load power consumption <0.75W LED indicator for power on % full load burn-in test relay contact 3 year warranty Multiple output connector for easy wiring on PS-S, PS-S60 and PS-S models 35mm DIN Rail Mounting Robust plastic housing DC on LED signal Adjustable DC output voltage Easy to understand layout panel CE Compliance UL508 Listed UL1310 Recognized Universal Input Compact for maximized panel space Multiple output connector for easy wiring 35mm DIN Rail Mounting Adjustable DC output voltage DC on LED signal Easy to understand layout panel CE Compliance Metal housing Universal Input Compact for maximized panel space 7

Compact Single Phase Power Supply (PSC) E361935 E0541 10W Single Output Industrial DIN Rail Power Supply Cat. No. Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-101 1V DC 0.84A ±1% mvp-p 81% PSC-1015 15V DC 0.67A ±1% mvp-p 81% PSC-104 4V DC 0.4A ±1% 10 mvp-p 81% 0W Single Output Industrial DIN Rail Power Supply Cat. No. Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-01 1V DC 1.7A ±1% mvp-p 83% PSC-015 15V DC 1.4A ±1% mvp-p 85% PSC-04 4V DC 1A ±1% 10 mvp-p 86% W Single Output Industrial DIN Rail Power Supply Cat. No. Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-1 1V DC 3.4A ±1% mvp-p 84% PSC-15 15V DC.7A ±1% mvp-p 84% PSC-4 4V DC 1.7A ±1% 10 mvp-p 84% PSC-48 48V DC 0.85A ±1% 180 mvp-p 85% 60W Single Output Industrial DIN Rail Power Supply Cat. No. Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-601 1V DC 5A ±1% mvp-p 86% PSC-6015 15V DC 4A ±1% mvp-p 87% PSC-604 4V DC.5A ±1% 10 mvp-p 87% PSC-6048 48V DC 1.5A ±1% 180 mvp-p 88% 96W Single Output Industrial DIN Rail Power Supply Cat. No. Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-961* 1V DC 7.5A ±1% 180 mvp-p 87% PSC-9615* 15V DC 6.4A ±1% 180 mvp-p 87% PSC-964 4V DC 4A ±1% 180 mvp-p 88% PSC-9648 48V DC A ±1% 50 mvp-p 87% *Not included in UL file E361915 8

SPECIFICATIONS PSC-10 Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB) Series 1 FG 4 DC +V AC/N 5 DC -V 3 AC/L 6 SIGNAL 99 3 PSC-0 Series Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB) 1 FG 4 DC +V AC/N 5 DC -V 3 AC/L 6 SIGNAL 99 3 PSC- Series Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB) 1 FG 1/ DC +V AC/N 3/4 DC -V 3 AC/L 5/6 Relay Contact 99 PSC-60 Series Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB) 1 FG 1/ DC +V AC/N 3/4 DC -V 3 AC/L 5/6 Relay Contact 99 PSC-96 Series 99 55 Terminal Pin. No Assign. (TB1) Terminal Pin. No Assign. (TB) 1 FG 1/ DC +V AC/N 3/4 DC -V 3 AC/L 5/6 Relay Contact 9

PSC-10 Series E361935 E0541 Features: Universal AC input (88-64V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True signal output All wiring 105 C long life electrolytic capacitors High operation temperature up to 70 C Withstands G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class Power unit / LPS pass UL508 (Industrial control equipment) listed INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-101 PSC-1015 PSC-104 DC VOLTAGE 1V 15V 4V RATED CURRENT 0.84A 0.67A 0.4A CURRENT RANGE 0~0.84A 0~0.67A 0~0.4A RATED POWER 10.08W 10.05W 10.08W RIPPLE & NOISE (max) mvp-p mvp-p 10mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE 10.8~13.V 13.5~16.5V 1.6~6.4V VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% SETUP, RISE TIME < 800ms, < ms/30v AC at full load HOLD UP TIME (Typ.) > 3ms / 30V AC; > 16ms / 115V AC at full load VOLTAGE RANGE 88V~64VAC; 14V~370VDC Derating may be needed under low input voltages. Please check the derating curve for more details. FREQUENCY RANGE 47~63Hz EFFICIENCY (Typ.) 81% 81% 81% AC CURRENT (Typ.) 0.3A/115VAC; 0.17A/30VAC INRUSH CURRENT (Typ.) 15A / 115V AC; 30A / 30V AC LEAKAGE CURRENT < 1mA/ 30VAC OVERLOAD PROTECTION OVERVOLTAGE PROTECTION > 10% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. 115%~150% rated output voltage Protection type: Latch-off mode. OVER TEMPERATURE PROTECTION Power supply shut down at 70 C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -0 ~ +70 C (Refer to output load derating curve) 0 ~ % RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% / C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:006+A11, UL1310 NEC class compliant WITHSTAND VOLTAGE I/P-O/P: 3KVAC (44DC) I/P-FG: 1.5KVAC (11DC) 1 minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: M Ohms/500VDC EMI CONDUCTION & RADIATION EN550:006+A1:007 Class B HARMONIC CURRENT EN60-3-:006 Class A, EN60-3-3:008 EMS IMMUNITY EN6104-3:000, EN5504:1998+A1:001+A:003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Signal Open collector. Max: ma MTBF 56.7K hrs MIL-HDBK-17K DIMENSION 3xx99 mm (WxHxD) PACKING 0.13Kg/48 pcs. / 7.44Kg CONNECTION I/P 3 poles, O/P: 3 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 30V AC input, rated load and 5 C of ambient temperature. 10

PSC-10 Series Mechanical Specification Unit : mm / inch 3 99 Terminal Pin. No Assign. (TB1) 1 FG AC/N 3 AC/L Terminal Pin. No Assign. (TB) 4 DC +V 5 DC -V 6 SIGNAL 5 5 Application of Active Signal (a)5v signal (b)led (c)relay R 5.1V Model 1V 15V R R Model 1V 15V R Relay RL Model 1V 15V R V- 4V V- 4V V- 4V Block Diagram I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P DETECTION O.L.P. CONTROL O.V.P. Derating Curve Load V.S Temp. Load V.S I/P Voltage Ta=5 C 80 60 80 70 60 50 0-0 0 10 0 30 50 60 70 85 110 10 64VAC Ambient Temperature ( C) Input Voltage(VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 11

PSC-0 Series E361935 E0541 Features: Universal AC input (88-64V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True signal output All wiring 105 C long life electrolytic capacitors High operation temperature up to 70 C Withstands G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class Power unit / LPS pass UL508 (Industrial control equipment) listed INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-01 PSC-015 PSC-04 DC VOLTAGE 1V 15V 4V RATED CURRENT 1.7A 1.4A 1A CURRENT RANGE 0~1.7A 0~1.4A 0~1A RATED POWER 0.4W 1W 4W RIPPLE & NOISE (max) mvp-p mvp-p 10mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE 10.8~13.V 13.5~16.5V 1.6~6.4V VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% SETUP, RISE TIME < 800ms, < ms/30v AC at full load HOLD UP TIME (Typ.) > 3ms / 30V AC; > 16ms / 115V AC at full load VOLTAGE RANGE 88V~64VAC; 14V~370VDC Derating may be needed under low input voltages. Please check the derating curve for more details. FREQUENCY RANGE 47~63Hz EFFICIENCY (Typ.) 83% 85% 86% AC CURRENT (Typ.) 0.45A/115VAC; 0.3A/30VAC INRUSH CURRENT (Typ.) 0A / 115V AC; A / 30V AC LEAKAGE CURRENT < 1mA/ 30VAC OVERLOAD PROTECTION OVERVOLTAGE PROTECTION > 105% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. 115%~150% rated output voltage Protection type: Latch-off mode. OVER TEMPERATURE PROTECTION Power supply shut down at 70 C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -0 ~ +70 C (Refer to output load derating curve) 0 ~ % RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% / C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:006+A11, UL1310 NEC class compliant WITHSTAND VOLTAGE I/P-O/P: 44DC I/P-FG: 11DC 1 minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: M Ohms/500VDC EMI CONDUCTION & RADIATION EN550:006+A1:007 Class B HARMONIC CURRENT EN60-3-:006 Class A, EN60-3-3:008 EMS IMMUNITY EN6104-3:000, EN5504:1998+A1:001+A:003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Signal Open collector. Max: ma MTBF 10.4K HRS MIL-HDBK-17 (5 C) 131.3K HRS MIL-HDBK-17 (5 C) 15.9K HRS MIL-HDBK-17 (5 C) DIMENSION 3xx99 mm (WxHxD) PACKING 0.14Kg/48 pcs./7.9kg CONNECTION I/P 3 poles, O/P: 3 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 30V AC input, rated load and 5 C of ambient temperature. 1

PSC-0 Series Mechanical Specification Unit : mm / inch 3 99 Terminal Pin. No Assign. (TB1) 1 FG AC/N 3 AC/L Terminal Pin. No Assign. (TB) 4 DC +V 5 DC -V 6 SIGNAL 5 5 Application of Active Signal (a)5v signal (b)led (c)relay R 5.1V Model R 1V 1.5K 15V K R Model R 1V.4K 15V 3K Relay RL Model R 1V 700 15V 700 V- 4V 3.9K V- 4V 4.7K V- 4V 1.K Block Diagram I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P DETECTION O.L.P. CONTROL O.V.P. Derating Curve Load V.S Temp. Load V.S I/P Voltage Ta=5 C 80 60 80 70 60 50 0-0 0 10 0 30 50 60 70 85 110 10 64VAC Ambient Temperature ( C) Input Voltage(VAC)60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 13

PSC- Series E361935 E0541 Features: Universal AC input (88-64V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True signal output All wiring 105 C long life electrolytic capacitors High operation temperature up to 70 C Withstands G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class Power unit / LPS pass UL508 (Industrial control equipment) listed INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-1 PSC-15 PSC-4 PSC-48 DC VOLTAGE 1V 15V 4V 48V RATED CURRENT 3.4A.7A 1.7A 0.85A CURRENT RANGE 0 ~ 3.4A 0 ~.7A 0 ~ 1.7A 0 ~ 0.85A RATED POWER.8W.5W.8W.8W RIPPLE & NOISE (max) mvp-p mvp-p 10mVp-p 180mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE 10.8 ~ 13.V 13.5 ~ 16.5V 1.6 ~ 6.4V 43. ~ 5.8V VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% SETUP, RISE TIME < 800ms, < 50ms / 30VAC at full load HOLD UP TIME (Typ.) > 3ms / 30VAC; >16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 64VAC; 14 ~ 370VDC Derating may be needed under low input voltages. Please check the derating curve for more details. FREQUENCY RANGE EFFICIENCY (Typ.) 47~63Hz 84% 84% 84% 85% AC CURRENT (Typ.) 0.8 A / 115VAC; 0.4A / 30VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC; 60A / 30VAC LEAKAGE CURRENT < 1mA/ 30VAC OVERLOAD PROTECTION OVERVOLTAGE PROTECTION > 105% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. 115% ~ 150% rated output voltage Protection type: latch-off mode OVER TEMPERATURE PROTECTION Power supply shut down at 70 C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -0 ~ +70 C (Refer to output load derating curve) 0 ~ % RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% / C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:006+A11, UL1310 NEC class compliant WITHSTAND VOLTAGE I/P-O/P: 44DC I/P-FG: 11DC 1 minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: M Ohms/500VDC EMI CONDUCTION & RADIATION EN550: 006 Class B HARMONIC CURRENT EN60-3-: 006 Class A, EN60-3-3: 1995+A1: 001+A: 005 EMS IMMUNITY EN6104-3:000, EN5504:1998+A1:001+A:003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Signal Relay contact (30VDC / 1A, 10VAC / 1A) MTBF 947.K hrs MIL-HDBK-17K DIMENSION xx99 mm (WxHxD) PACKING 0.8Kg/7 pcs./8.76kg CONNECTION I/P 3 poles, O/P: 6 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 30V AC input, rated load and 5 C of ambient temperature. 14

PSC- Series Mechanical Specification Unit : mm / inch 99 Terminal Pin. No Assign. (TB1) Pin No. Assignment 1 FG 3 AC/N AC/L Terminal Pin. No Assign. (TB) 1, DC +V 3,4 DC -V 5,6 RELAY CONTACT N L Block Diagram I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. DETECTION O.L.P. CONTROL O.V.P. Relay Contact Contact Close Contact Open Contact Ratings (max.) When the output voltage reaches the adjusted output voltage When the output voltage drop below % rated output voltage 30V / 1A resistive load Derating Curve Load V.S Temp. Load V.S I/P Voltage Ta=5 C 80 60 80 70 60 50 0-0 0 10 0 30 50 60 70 85 110 10 64VAC Ambient Temperature ( C) Input Voltage(VAC)60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 15

PSC-60 Series E361935 E0541 Features: Universal AC input (88-64V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True signal output All wiring 105 C long life electrolytic capacitors High operation temperature up to 70 C Withstands G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class Power unit / LPS pass UL508 (Industrial control equipment) listed INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-601 PSC-6015 PSC-604 PSC-6048 DC VOLTAGE 1V 15V 4V 48V RATED CURRENT 5A 4A.5A 1.5A CURRENT RANGE 0 ~ 5A 0 ~ 4A 0 ~.5A 0 ~ 1.5A RATED POWER 60W 60W 60W 60W RIPPLE & NOISE (max) mvp-p mvp-p 10mVp-p 180mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE 10.8 ~ 13.V 13.5 ~ 16.5V 1.6 ~ 6.4V 43. ~ 5.8V VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% SETUP, RISE TIME < 800ms, < 50ms / 30VAC at full load Length of set up time is measured at sold first start. Turning ON/OFF the power supply may lead to increase of the set up time. HOLD UP TIME (Typ.) > 3ms / 30VAC; >16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 64VAC; 14 ~ 370VDC Derating may apply in low input voltage. Please check the derating curve for more details. FREQUENCY RANGE 47~63Hz EFFICIENCY (Typ.) 86% 87% 87% 88% AC CURRENT (Typ.) 1.3 A / 115VAC; 0.6A / 30VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC; 60A / 30VAC LEAKAGE CURRENT <1mA / 30VAC OVER LOAD PROTECTION > 10% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode OVER TEMPERATURE PROTECTION Power supply shut down at 70 C constant current limiting / output voltage goes to 0; re-power on to recover WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -0 ~ +70 C (Refer to output load derating curve) 0 ~ % RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% / C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:006+A11, UL1310 NEC class compliant WITHSTAND VOLTAGE I/P-O/P: 44DC, I/P-FG: 11DC 1 minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: M Ohms/500VDC EMI CONDUCTION & RADIATION EN550: 006 Class B HARMONIC CURRENT EN60-3-: 006 Class A, EN60-3-3: 1995+A1: 001+A: 005 EMS IMMUNITY EN6104-3: 000, EN5504: 1998+A1:001+A: 003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Signal Relay contact (4VDC / 1A, 10VAC / 1A) MTBF 944.6K HRS MIL-HDBK-17F DIMENSION xx99 mm (WxHxD) PACKING 0.3kg; 7pcs / 9.3kg CONNECTION I/P: 3 poles, O/P: 6 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 30V AC input, rated load and 5 C of ambient temperature. 16

PSC-60 Series Mechanical Specification Unit : mm / inch 99 Terminal Pin. No Assign. (TB1) Pin No. Assignment 1 FG 3 AC/N AC/L Terminal Pin. No Assign. (TB) 1, DC +V 3,4 DC -V 5,6 RELAY CONTACT N L Block Diagram I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. DETECTION O.L.P. CONTROL O.V.P. Relay Contact Contact Close Contact Open Contact Ratings (max.) When the output voltage reaches the adjusted output voltage When the output voltage drop below % rated output voltage 30V / 1A resistive load Derating Curve Load V.S Temp. Load V.S I/P Voltage Ta=5 C 80 60 80 70 60 50 0-0 0 10 0 30 50 60 70 85 110 10 64VAC Ambient Temperature ( C) Input Voltage(VAC)60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 17

PSC-96 Series E361935 E0541 Features: Universal AC input (88-64V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True signal output All wiring 105 C long life electrolytic capacitors High operation temperature up to 70 C Withstands G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class Power unit / LPS pass UL508 (Industrial control equipment) listed INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-961* PSC-9615* PSC-964 PSC-9648 DC VOLTAGE 1V 15V 4V 48V RATED CURRENT 7.5A 6.4A 4A A CURRENT RANGE 0 ~ 7.5A 0 ~ 6.4A 0 ~ 4A 0 ~ A RATED POWER W 96W 96W 96W RIPPLE & NOISE (max) 180mVp-p 180mVp-p 180mVp-p 50mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE 10.8 ~ 13.V 13.5 ~ 16.5V 1.6 ~ 6.4V 43. ~ 5.8V VOLTAGE TOLERANCE ±1.0% ±1.0% ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±.0% ±.0% ±.0% ±.0% SETUP, RISE TIME < 800ms, < ms / 30VAC at full load HOLD UP TIME (Typ.) > 3ms / 30VAC; >16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 64VAC; 14 ~ 370VDC Derating may apply in low input voltage. Please check the derating curve for more details. FREQUENCY RANGE 47Hz~63Hz POWER FACTOR (Typ.) < 0.9 / 30VAC; < 0.98 / 115VAC at full load EFFICIENCY (Typ.) 87% 87% 88% 87% AC CURRENT (Typ.) 1.1 A / 115VAC; 0.55A / 30VAC INRUSH CURRENT (Typ.) COLD START 30A / 115VAC; 60A / 30VAC LEAKAGE CURRENT <1mA / 30VAC OVER LOAD PROTECTION OVER VOLTAGE PROTECTION OVER TEMPERATURE PROTECTION WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION > 10% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. 115% ~ 150% rated output voltage Protection type: latch-off mode C ± 10 C (RTH) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover -0 ~ +70 C (Refer to output load derating curve) 0 ~ % RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% / C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1:006+A11, UL1310 NEC class compliant WITHSTAND VOLTAGE I/P-O/P: 44DC I/P-FG: 11DC 1 minute ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: M Ohms/500VDC EMI CONDUCTION & RADIATION EN550:006 Class B HARMONIC CURRENT EN60-3-:006 Class A, EN60-3-3: 1995+A1: 001+A: 005 EMS IMMUNITY EN6104-3:000, EN5504:1998+A1:001+A:003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. Signal Relay contact (4VDC / 1A, 10VAC / 1A) MTBF 10.4K Hrs MIL-HDBK-17F DIMENSION 55xx99 mm (WxHxD) PACKING 0.4Kg/4 pcs. / 10.8Kg CONNECTION l/p 3 poles, 0/P: 6 poles screw DIN terminal COOLING Free air convection All parameters NOT specially mentioned are measured at 30V AC input, rated load and 5 C of ambient temperature. *Not included in UL E361935 18

PSC-96 Series Mechanical Specification Unit : mm / inch 55 99 Terminal Pin. No Assign. (TB1) 1 FG AC/N 3 AC/L Terminal Pin. No Assign. (TB) 1, DC +V 3,4 DC -V 5,6 RELAY CONTACT Block Diagram I/P EMI FILTER & RECTIFIERS PFC POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. O.L.P. O.V.P. O.L.P. DETECTION PWM&PFC CONTROL O.V.P. Relay Contact O.T.P. Contact Close Contact Open Contact Ratings (max.) When the output voltage reaches the adjusted output voltage When the output voltage drop below % rated output voltage 30V / 1A resistive load Derating Curve Load V.S Temp. Load V.S I/P Voltage Ta=5 C 80 60 80 70 60 50 0-0 0 10 0 30 50 60 70 85 110 10 64VAC Ambient Temperature ( C) Input Voltage(VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 19

Compact Single Phase Power Supply (PSC) E0541 Features: Universal AC input (88-64V AC) Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability % full load burn-in test Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in Relay contact Built-in Remote ON / OFF function 3 years warranty UL 508 150W DIN Rail Power Supply Cat. No. Phases Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-1514 1 4V DC 6.3A ±1% mvp-p 87% PSC-15148 1 48V DC 3.A ±1% 480 mvp-p 87% W DIN Rail Power Supply Cat. No. Phases Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-414 1 4V DC 10A ±1% 150 mvp-p 91% PSC-4148 1 48V DC 5A ±1% 300 mvp-p 9% 480W DIN Rail Power Supply Cat. No. Phases Output Tol. Ripple & Efficiency NOTES V DC A % Noise PSC-4814 1 4V DC 0A ±1% mvp-p 93% PSC-48148 1 48V DC 10A ±1% 480 mvp-p 94% 0A DIN Rail Redundancy Module Cat. No. Phases Output Input NOTES V DC A VDC A PSC-RM0 1 4V DC 0A 4VDC x0a 0

SPECIFICATIONS PSC-151 Series 15 55.5 Terminal (TB1) Pin NO. 1 3 Assignment FG AC/L AC/N Terminal (TB) Pin NO. Assignment 1 DC+ DC- 3 INH+ 4 INH- 5,6 Relay Contact Universal Input: Connection Input: Connection Output: Size (WxHxD): Packaging: Switch No. Assignment SW NO. SW1 SW Assignment PEAK LOAD SETTING REMOTE ON/OFF SETTING PSC-41 Series Terminal (TB1) Pin NO. 1 3 Assignment FG AC/L AC/N Terminal (TB) Pin NO. Assignment 1 DC+ DC- 3 INH+ 4 INH- 5,6 Relay Contact Switch No. Assignment SW NO. SW1 SW Assignment PEAK LOAD SETTING REMOTE ON/OFF SETTING 15 118 66 Universal Input: Connection Input: Connection Output: Size (WxHxD): Packaging: PSC-481 Series Terminal (TB1) Pin NO. 1 3 Assignment FG AC/L AC/N Terminal (TB) Pin NO. Assignment 1-3 DC+ 4-6 DC- 7 8 9,10 INH+ INH- Signal Switch No. Assignment SW NO. SW1 SW Assignment PEAK LOAD SETTING REMOTE ON/OFF SETTING 15 13 86 Universal Input: Connection Input: Connection Output: Size (WxHxD): Packaging: PSC-RM0 Terminal Pin. No Assignment (TB1) 1 3,4 5 6 Vout+ Vout- Vin- Vin B+ Vin A+ Terminal Pin. No Assignment (TB) 1 3 4 Alarm B1 Alarm B Alarm A1 Alarm A 15 55.5 Input: Connection Input: Connection Output: Size (WxHxD): Packaging: 1

PSC-151 Series E0541 Features: Universal AC input (88-64V AC) Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability % full load burn-in test Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in Relay contact Built-in Remote ON / OFF function 3 years warranty UL 508 INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-1514 PSC-15148 DC VOLTAGE 4V 48V RATED CURRENT 6.3A 3.A CURRENT RANGE 0~6.3A 0~3.A RATED POWER 150W 150W PEAK CURRENT 9.45A 4.8A PEAK POWER 5W (3sec.) 3 seconds or 0% duty cycle max. and the average output power should not exceed the rate power. RIPPLE & NOISE (max) mvp-p 480mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE -% ~ +8% -% ~ +8% VOLTAGE TOLERANCE ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±0.5% ±0.5% LOAD REGULATION ±1.0% ±1.0% SETUP, RISE TIME 700ms, 30ms / 30VAC / 115VAC at full load HOLD UP TIME (Typ.) 16ms / 30VAC; 16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 64VAC; 14 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR(Typ.) 0.9 / 30VAC; 0.98 / 115VAC at full load EFFICIENCY (Typ.) 87% 87% AC CURRENT (Typ.).0A / 115VAC; 1.0A / 30VAC INRUSH CURRENT (Typ.) 33A / 115VAC; 65A / 30VAC LEAKAGE CURRENT <1mA/ VAC OVERLOAD PROTECTION 105% ~ 150% rated output power for 3 sec and then shutdown in O/P with auto-recovery. 150% or greater rated power or short circuit is constant current limiting. If O/P drops to % output then it auto-recover 5 times; if fault condition is not removed during auto recovery, the system will shut down and needs to be restarted to recover. OVER VOLTAGE 9 ~ 33V 56 ~ 65V Protection type: Latch-off mode, repower on to recover. OVER TEMPERATURE 95 ±5 C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -10 ~ +70 C (Refer to derating curve) Installation clearance: mm from top, 0mm from bottom, 5mm from the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 0 ~ 95% RH non-condensing - ~ +85 C, 10 ~ 95% RH ±0.03% / C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL 508 / TUV EN 60950-1 WITHSTAND VOLTAGE I/P-O/P: 44VDC, I/P-FG: 11VDC, O/P-FG: 707VDC, O/P-: 707VDC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: >M Ohms / 500VDC / 5 C / 70% RH EMI CONDUCTION & RADIATION EN550 (CISPR) Class B HARMONIC CURRENT EN60-3-, -3 EMS IMMUNITY Compliance to EN60-4-,3,4,5,6,8,11; ENV5004; EN5504; EN60-6-; (EN5008-); EN6104-3; heavy industry level; criteria A, MEET SEMI F47 The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. RELAY. CONTACT RATINGS (max) 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load MTBF 6.7K HRS (MIL-HDBK-17F) DIMENSION 55.5x15.x99.8 mm (WxHxD) PACKING 0.7kg; 1pcs / 1.8kg COOLING Free air convection All parameters NOT specially mentioned are measured at 30VAC input, rated load and 5 C of ambient temperature.

PSC-151 Series Mechanical Specification Unit : mm / inch Terminal (TB1) Pin NO. 1 3 Assignment FG AC/L AC/N Terminal (TB) Pin NO. Assignment 1 DC+ DC- 3 INH+ 4 INH- 5,6 Relay Contact TB 55.5 1 3 4 5 6 Relay Contact 99.8 Switch No. Assignment SW NO. SW1 SW Assignment PEAK LOAD SETTING REMOTE ON/OFF SETTING +V ADJ. + DC ON ON OFF SW1 SW 15. 1 TB1 3 Block Diagram I/P EMI FILTER & RECTIFIERS PFC POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. FG O.L.P. O.L.P. O.L.P. AC DETECTION PWM & PFC CONTROL DETECTION MICRO O.V.P. O.T.P. Relay C REMOTE CONTROL INH+ INH- Relay Contact PEAK LOAD CONTROL Contact Close Contact Open Contact Ratings(max.) When the output voltage reaches the adjusted output voltage. When the output voltage drop below 45% rated output voltage. 30V/1A resistive load Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 3

PSC-151 Series E0541 Peak Load SW1 ON (Mode1) Default setting I I-peak I-normal T-normal T-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy -stage battery charger. 0 T Peak Load SW OFF (Mode) I I-peak T-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T T-normal (Sec.) 4 0 18 16 14 1 10 8 6 4 0 10% 0% 30% % 50% 60% 70% 80% % CURVE A T-peak (Sec.) 0 18 16 14 1 10 8 6 4 0 I-normal 110% 115% 10% 15% 130% 135% 1% 145% 150% I-peak CURVE B 4

PSC-151 Series Remote ON/OFF The PSU can be turned ON/OFF by using the "Remote Control" function. SW 1 3 4 5 6 External Power Source I = 6 ~ 0mA SW OFF OFF ON ON INH+(3 PIN)/ INH-(4 PIN) SW ON (>.5V) SW OFF (<0.8V) SW ON (>.5V) SW OFF (<0.8V) Output Status ENABLE DISABLE DISABLE ENABLE (Default Setting) TB + +V ADJ. DC ON Relay Contact ON OFF SW1 SW Derating Curve 150 11.5 60 For typ. 3sec Continuous -10 0 10 0 30 50 60 70 (Vertical) Ambient Temperature ( C) AC=30 / 115VAC Output derating VS input Voltage 80 70 60 50 88 110 135 30 64VAC Input Voltage (V) 60Hz Ta=5 C 5

PSC-41 Series E0541 Features: Universal AC input (88-64V AC) High efficiency 9% and low power dissipation Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability % full load burn-in test Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in Relay contact Built-in Remote ON / OFF function 3 years warranty UL 508 INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-414 PSC-4148 DC VOLTAGE 4V 48V RATED CURRENT 10A 5A CURRENT RANGE 0~10A 0~5A RATED POWER W W PEAK CURRENT 15A 7.5A PEAK POWER 360W (3sec.) Two selectable peak load modes 3 seconds or 0% duty cycle Max. The average output power should not exceed the rate power. RIPPLE & NOISE (max) 150mVp-p 300mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE -% ~ +8% -% ~ +8% VOLTAGE TOLERANCE ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±0.5% ±0.5% LOAD REGULATION ±1.0% ±1.0% SETUP, RISE TIME 700ms, 30ms / 30VAC / 115VAC at full load HOLD UP TIME (Typ.) 0ms / 30VAC; 0ms / 115VAC at full load VOLTAGE RANGE 88 ~ 64VAC; 14 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.96 / 30VAC; 0.96 / 115VAC at full load EFFICIENCY (Typ.) 91% 9% AC CURRENT (Typ.).6A / 115VAC; 1.3A / 30VAC INRUSH CURRENT (Typ.) 33A / 115VAC; 65A / 30VAC LEAKAGE CURRENT <1mA/ VAC OVERLOAD 105% ~ 150% rated output power for 3 sec and then shutdown in O/P with auto-recovery. 150% or greater rated power or short circuit is constant current limiting. If O/P drops to % output then it auto-recover 5 times; if fault condition is not removed during auto recovery, the system will shut down and needs to be restarted to recover. OVER VOLTAGE 8 ~ 33V 56 ~ 65V Protection type: Shut down O/P voltage with auto-recovery OVER TEMPERATURE 95 ±5 C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -5 ~ +70 C (Refer to output load derating curve) Installation clearances: mm on top, 0mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 0 ~ 95% RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL508, TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P: 44VDC I/P-FG11VDC O/P-F/G: 707VDC O/P-: 707VDC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: > M Ohms / 500VDC / 5 C / 70% RH EMI CONDUCTION & RADIATION EN550:006 Class B HARMONIC CURRENT EN60-3-: 006 Class A, ENG0-3-3: 1995 +A1: 001+A: 005 EMS IMMUNITY EN6104-3: 000, EN5504: 1998+A1: 001+A: 003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. RELAY CONTACT RATINGS (max) MTBF DIMENSION PACKING COOLING 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load 57K HRS (MIL-HDBK-17F) 65.8x15.x117.7 mm (WxHxD) 0.9kg; 1pcs / 1.8kg Free air convection All parameters NOT specially mentioned are measured at 30VAC input, rated load and 5 C of ambient temperature. 6

PSC-41 Series Mechanical Specification Unit : mm / inch Terminal (TB1) Pin NO. 1 3 Assignment FG AC/L AC/N Terminal (TB) Pin NO. Assignment 1 DC+ DC- 3 INH+ 4 INH- 5,6 Relay Contact 65.80 1 3 4 5 6 TB 117.7 65.8 117.7 Relay Contact Switch No. Assignment SW NO. SW1 SW Assignment PEAK LOAD SETTING REMOTE ON/OFF SETTING +V ADJ. + DC ON ON OFF SW1 SW 15. 1 3 TB1 Block Diagram I/P EMI FILTER & RECTIFIERS ACTIVE INRUSH CURRENT LIMITING PFC POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. FG O.L.P. O.L.P. AC DETECTION PFC CONTROL PWM POWER CONTROL DETECTION MICRO O.V.P. O.T.P. Relay Contact REMOTE CONTROL INH+ INH- PEAK LOAD CONTROL Relay Contact Contact Close When the output voltage reaches the adjusted output voltage. Contact Open When the output voltage drop below 45% rated output voltage. Contact Ratings(max.) 30V/1A resistive load Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 7

PSC-41 Series E0541 Peak Load SW1 ON (Mode1) Default setting I I-peak I-normal T-normal T-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy -stage battery charger. 0 T Peak Load SW OFF (Mode) I I-peak T-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T T-normal (Sec.) 4 0 18 16 14 1 10 8 6 4 0 10% 0% 30% % 50% 60% 70% 80% % CURVE A T-peak (Sec.) 0 18 16 14 1 10 8 6 4 0 I-normal 110% 115% 10% 15% 130% 135% 1% 145% 150% I-peak CURVE B 8

PSC-41 Series Remote ON/OFF The PSU can be turned ON/OFF by using the "Remote Control" function. TB SW 1 3 4 5 6 External Power Source I = 6 ~ 0mA SW OFF OFF ON ON INH+(3 PIN)/ INH-(4 PIN) SW ON (>.5V) SW OFF (<0.8V) SW ON (>.5V) SW OFF (<0.8V) Output Status ENABLE DISABLE DISABLE ENABLE (Default Setting) + +V ADJ. DC ON ON OFF SW1 SW Derating Curve 150 11.5 60 For typ. 3sec Continuous -10 0 10 0 30 50 60 70 (Vertical) Ambient Temperature ( C) AC=30 / 115VAC Output derating VS input Voltage 80 70 60 50 88 110 135 30 64VAC Input Voltage(V)60Hz Ta=5 C 9

PSC-481 Series E0541 Features: Universal AC input (88-64V AC) Installed on DIN rail TS-35 / 7.5 or 15 Built-in active PFC function, PF > 0.95 150% peak load capability Protection: SCP, OLP, OVP, OTP Two selectable peak load modes Built-in (Open Collector Signal) Built-in Remote ON / OFF function 3 years warranty UL 508 INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PSC-4814 PSC-48148 DC VOLTAGE 4V 48V RATED CURRENT 0A 10A CURRENT RANGE 0~0A 0~10A RATED POWER 480W 480W PEAK CURRENT 30A 15A PEAK POWER 70W (3sec.) Two selectable peak load modes 3 seconds or 0% duty cycle Max. The average output power should not exceed the rate power. RIPPLE & NOISE (max) mvp-p 480mVp-p Ripple & noise are measured at 0MHz of bandwidth by using a 1 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor. VOLTAGE ADJ. RANGE -5% ~ +5% VOLTAGE TOLERANCE ±1.0% ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. LINE REGULATION ±0.5% ±0.5% LOAD REGULATION ±1.0% ±1.0% SETUP, RISE TIME 800ms, ms / 30VAC / 115VAC at full load HOLD UP TIME (Typ.) 16ms / 30VAC; 16ms / 115VAC at full load VOLTAGE RANGE 88 ~ 64VAC; 14 ~ 373VDC Derating may apply in low input voltage. Please check the derating curve for more details. FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.96 / 30VAC / 115VAC at full load EFFICIENCY (Typ.) 93% 94% AC CURRENT (Typ.) 5.0A / 115VAC;.5A / 30VAC INRUSH CURRENT (Typ.) 33A / 115VAC; 65A / 30VAC LEAKAGE CURRENT < 1mA/ VAC OVERLOAD 105% ~ 150% rated output power for 3 sec and then shutdown in O/P with auto-recovery. 150% or greater rated power or short circuit is constant current limiting. If O/P drops to % output then it auto-recover 5 times; if fault condition is not removed during auto recovery, the system will shut down and needs to be restarted to recover. OVER VOLTAGE 9 ~ 33V 56 ~ 65V Protection type: Latch-off mode. OVER TEMPERATURE 95 ±5 C (TSW: detect on heatsink of power diode) Protection type: Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -0 ~ +70 C (Refer to output load derating curve) Installation clearance: mm from top, 0mm from the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat sorce, 15mm clearance is recomended. 0 ~ 95% RH non-condensing - ~ +85 C; 10 ~ 95% RH ±0.03% C (0 ~ 50 C) 10 ~ 500Hz, G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS UL 508 / EN 60950-1 WITHSTAND VOLTAGE I/P-O/P: 44VDC, I/P-FG: 11VDC, O/P-FG: 707VDC, O/P-: 707VDC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG: >M Ohms / 500VDC / 5 C / 70% RH EMI CONDUCTION & RADIATION EN 550 (CISPR), EN 60-6-3 HARMONIC CURRENT EN60-3-, -3-3 EMS IMMUNITY IEC 60-4-, 3, 4, 5, 6, 8, 11; EN 60-6-1; EN 6104-3 The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. RELAY CONTACT RATINGS (max) DIMENSION PACKING 60VDC / 0.3A, 30VDC / 1A, 30VAC / 0.5A resistive load 86.3x14.8x13.4 mm (WxHxD) 1.45kg; 8pcs / 1kg All parameters NOT specially mentioned are measured at 30VAC input, rated load and 5 C of ambient temperature. 30

PSC-481 Series Mechanical Specification Unit : mm / inch Terminal (TB1) Pin NO. 1 3 Assignment FG AC/L AC/N Terminal (TB) Pin NO. Assignment 1-3 DC+ 4-6 DC- 7 8 9,10 INH+ INH- Singal TB 86.3 1 3 4 5 6 7 8 910 13.4 Switch No. Assignment SW NO. SW1 SW Assignment PEAK LOAD SETTING REMOTE ON/OFF SETTING +V ADJ. + DC ON ON OFF SW1 SW 14.8 TB1 1 3 Block Diagram I/P EMI FILTER & RECTIFIERS ACTIVE inrush CURRENT LIMITING PFC POWER SWITCHING RECTIFIERS & FILTER +V -V O.C.P. FG O.L.P. O.L.P. AC DETECTION PFC CONTROL PWM POWER CONTROL DETECTION MICRO O.V.P. O.T.P. Singal REMOTE CONTROL INH+ INH- PEAK LOAD CONTROL Relay Contact Contact Ratings(max.) CTR : MIN. 50% at IF = 5mA, VCE = 5V Isolation Voltage Between input and output Viso = 3750Vrms Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. 31

PSC-481 Series E0541 Peak Load SW1 ON (Mode1) Default setting I I-peak I-normal T-normal T-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will drop to the constant current limit (I-normal) that is 105% rating power, meanwhile, I- normal and T-normal will be presenting. See curve "A" for the timing back to I-Peak of T-normal and this Mode can use for easy -stage battery charger. 0 T Peak Load SW OFF (Mode) I I-peak T-peak T-peak presents while the unit is working within 110%~150% Rating output power. See curve " B " for the variation in T-peak between output current and holdup time. If T-peak is more than the time setting in curve "B", the output current will be shut down for 3~4 sec, then auto-recovery. 0 3 ~ 4 sec T T-normal (Sec.) 4 0 18 16 14 1 10 8 6 4 0 10% 0% 30% % 50% 60% 70% 80% % CURVE A T-peak (Sec.) 0 18 16 14 1 10 8 6 4 0 I-normal 110% 115% 10% 15% 130% 135% 1% 145% 150% I-peak CURVE B 3

PSC-481 Series Remote ON/OFF The PSU can be turned ON/OFF by using the "Remote Control" function. TB SW 1 3 4 5 6 External Power Source I = 6 ~ 0mA SW OFF OFF ON ON INH+(3 PIN)/ INH-(4 PIN) SW ON (>.5V) SW OFF (<0.8V) SW ON (>.5V) SW OFF (<0.8V) Output Status ENABLE DISABLE DISABLE ENABLE (Default Setting) + +V ADJ. DC ON ON OFF SW1 SW Derating Curve 150 11.5 60 For typ. 3sec Continuous -10 0 10 0 30 50 60 70 (Vertical) Ambient Temperature ( C) AC=30 / 115VAC Output derating VS input Voltage 80 70 60 50 88 110 135 30 64VAC Input Voltage(V)60Hz Ta=5 C 33

PSC-RM0 Specifications Features: Suitable for redundant operation of 4V system Installed on DIN Rail TS35 / 7.5 or 15 Relay contact signal output and LED indicator for input failure alarm Cooling by free air convection 3 year warranty INPUT PROTECTION ENVIRONMENT SAFETY & EMC Cat. No. PS-RDN0 REVERSE VOLTAGE (max.) 30V CURRENT (max.) 0A VOLTAGE DROP 0.5V LED INDICATORS Two green LED s indicating each input is OK or fail INPUT VOLTAGE RANGE NUMBER OF INPUTS INPUT CURRENT (max.) INPUT VOLTAGE ALARM RELAY CONTACT RATING (max.) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION MOUNTING 1 ~ 8V Two 0A per input When input is 0V (±5%) or 30V (±5%) relay contacts 30VDC, 1A -0 ~ +70 C 0 ~ % RH non-condensing - ~ +85 C, 10 ~ 95% RH 10 ~ 500Hz, G 10min./1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068--6 WITHSTAND VOLTAGE Terminal- Chassis: 0.5KVAC, Relay Contacts- Terminal: 0.5KVAC ISOLATION RESISTANCE Terminal- Chassis: M Ohms / 500VDC (5 C; 70% RH) EMI CONDUCTION & RADIATION Compliance to EN550 (CISPR) Class B EMS IMMUNITY Compliance to EN60-4-,3,4,5,6,8; ENV5004; heavy industry level; criteria A, MTBF 996.8Khrs min. MIL-HDBK-17K (5 C) DIMENSION 55.5x15.xmm (WxHxD) PACKING 0.45Kg; 0pcs / 11Kg / 1.9CUFT All parameters NOT specially mentioned are measured at 4V DC input, rated load and 5 C of ambient temperature. Block Diagram Vout+ Vin/Vout- Vin A+ RELAY B RELAY A + + Alarm A 34