Application for Assessment of a full quality assurance system regarding Measuring Instruments in accordance with MID

Similar documents
(Non-legislative acts) DECISIONS

DNVGL-CP-0338 Edition October 2015

Type Approval JANUARY The electronic pdf version of this document found through is the officially binding version

GENERAL DESCRIPTION OF THE CMC SERVICES

The New Legislative Framework Revision of the NAWI-D and the MI-D

Guide on the General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments

Assemblies according to the Pressure Equipment Directive - a consideration provided by the PED-AdCo Group 1 -

Annex to application for conformity assessment of Heat meters in accordance with MID

Measuring Instruments Directive 2014/32/EU Thermal Energy Meters Corresponding Tables OIML R 75:2002

1 SERVICE DESCRIPTION

WELMEC European cooperation in legal metrology

Machinery Directive 2006/42/EC

DNVGL-CG-0214 Edition September 2016

Recast de la législation européenne et impact sur l organisation hospitalière

MISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration

AGREEMENT on UnifiedPrinciples and Rules of Technical Regulation in the Republic of Belarus, Republic of Kazakhstan and the Russian Federation

Co-ordination of the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD Conference on CPR

CHECKLIST FOR DESIGNATING AUTHORITIES DESIGNATION OF NOTIFIED LABORATORY. 1. General Requirement Complies Comments

EU- T y p e E x a m i n a t i o n C e r t i f i c a t e

Taximeters common application Directive 2014/32/EU, annexes I & IX (MI-007)

EU- T y p e E x a m i n a t i o n C e r t i f i c a t e

UNION COUNTY VOCATIONAL-TECHNICAL SCHOOLS West Hall Addition Project Raritan Road, Scotch Plains, NJ

Recommended code of good practice for the interpretation of Directive 2006/42/EC on machinery concerning air handling units Second Edition

NOTIFIED BODY EU-TYPE EXAMINATION CERTIFICATE

Fiscal 2007 Environmental Technology Verification Pilot Program Implementation Guidelines

NOTIFIED BODY EU-TYPE EXAMINATION CERTIFICATE

Operator s Manual. PP016 Passive Probe

Joint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.

CAMD Transition Sub Group FAQ IVDR Transitional provisions

EU-TYPE EXAMINATION CERTIFICATE

UCCS University Hall Fire Sprinkler System Upgrade March 1, 2011 RTA SECTION SUBMITTAL PROCEDURES PART 1 - GENERAL

ETSI EN V1.1.1 ( )

Unofficial Translation

CEPT MARKING AND THE R&TTE DIRECTIVE. Lisbon, June 2000

SECTION SUBMITTAL PROCEDURES

NOTIFIED BODY EU-TYPE EXAMINATION CERTIFICATE

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Position Paper.

Committee on the Internal Market and Consumer Protection

SECTION SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

COMMISSION IMPLEMENTING DECISION

Safety of Toys Implementing Regulation

THIRD SCHEDULE Form of Application For A Revised Disability Access Certificate Article 20E(2)

ETSI EN V1.1.2 ( ) Harmonized European Standard

Office for Nuclear Regulation

UK Broadband Ltd Spectrum Access Licence Licence Number: Rev: 4: 11 January 2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

In practice, the question is frequently raised of what legislation applies to clamping devices that are intended to be used on machines.

1. The Office of Communications (Ofcom) grants this wireless telegraphy licence ( the Licence ) to

EE Limited - Public Wireless Network Licence Company Registration no First Issued: 26/03/93 - Licence Number: Rev: 20-10/01/17

Electrical Procedure No E032. Procedure No: ELE 032

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

GSM R Notes on certification

- EMC Directive 2014/30/EU. Véronique Beauvois, Ir Copyright 2018 Véronique Beauvois, ULg

SECTION SUBMITTAL PROCEDURES

SECTION SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES

ETSI EN V1.5.1 ( ) Harmonized European Standard (Telecommunications series)

Connecting Systems for Cable Repair (Cable Splices)

SECTION SUBMITTAL PROCEDURES

MUSEUM SERVICE ACT I. BASIC PROVISIONS

WELMEC European cooperation in legal metrology

त न ब. BUREAU OF INDIAN STANDARDS Hallmarking Department, BIS. Subject: Draft BIS Hallmarking Regulations for comments

DNV GL approval of service supplier scheme

The Recast RoHS Directive 2011/65/EU

WG food contact materials

SEI Certification Program Manual

Having regard to the Treaty on the Functioning of the European Union, and in particular Article 16 thereof,

ETSI EN V1.3.1 ( )

Section Meetings Section Material and Equipment. None Required

Official Journal of the European Union

Technical Documentation for CE Marking

DIVISION 1 GENERAL REQUIREMENTS SECTION SUBMITTAL PROCEDURES

A. Action Submittals: Written and graphic information that requires Engineer's responsive action.

JEFFERSON LAB TECHNICAL ENGINEERING & DEVELOPMENT FACILITY (TEDF ONE) Newport News, Virginia

ETSI EN V1.1.1 ( )

THE INTERNATIONAL COSPAS-SARSAT PROGRAMME AGREEMENT

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

Designated Institutes participating in the CIPM MRA

Brad Luke. Director Peddle Thorp Auckland

Category: ELECTRICITY Requirement: EL-ENG Page: 1 of 13. Document(s): S-E-01, S-E-04 Issue Date: Effective Date:

Answer: Qualification statement should be provided with the bid.

South African Distribution Code

(Text with EEA relevance)

IAB Europe Guidance THE DEFINITION OF PERSONAL DATA. IAB Europe GDPR Implementation Working Group WHITE PAPER

ETSI EN V1.2.1 ( ) Harmonized European Standard

ETSI EN V1.3.1 ( )

A. Action Submittals: Written and graphic information that requires Architect's responsive action.

835 Gil Harbin Industrial Blvd Valdosta, GA 31601

SHARED TENANT SERVICE (STS) ARRANGEMENTS

Contents EUROPEAN UNION AGENCY FOR RAILWAYS. Accompanying Report Practical arrangements for safety certification ERA-REC-126/ACR V 1.

INTERNATIONAL STANDARD

COMMISSION DELEGATED DIRECTIVE../ /EU. of XXX

MEDICAL DEVICES : Guidance document

DNVGL-CP-0212 Edition March 2016

25 July 2017 Without prejudice [PROVISIONS IN RELATION TO TRADE IN GOODS ALREADY INCLUDED IN THE EU TEXT PROPOSAL FOR THE TRADE IN GOODS CHAPTER]

Agnieszka Żywicka* 1

TITLE OF THE CD (English): Revision: OIML B 10-1 and B 10-2 Framework for a Mutual Acceptance Arrangement on OIML Type Evaluations

Part 7: Thermography

COMMISSION REGULATION (EU) No /.. of XXX

1. The Office of Communications (Ofcom) grants this wireless telegraphy licence ( the Licence ) to

Transcription:

Application for Assessment of a full quality assurance system regarding Measuring Instruments in accordance with MID Company (applicant): hereby applies to RISE Research Institutes of Sweden AB, as Notified Body, in accordance with the MID-directive 2014/32/EU (Measuring Instruments Directive) for assessment of a quality system (module) registered below Module Conformity Assessment Module in H H1 The application is regarding New certificate: Revision of certificate No.: Renewal of certificate No. (extension of validity time): Type of instrument: MI-001 Water meters MI-003 Electric meters MI-004 Heat meters MI-005 Measuring systems, other liquids than water MI-008 Material Measures of length MI-006 Automatic weighing instruments MI-007 Taximeters Product (group/family): Model/type/ identification Description, intended use etc. Continue with: Information about the applicant, page 3 Confirmation/signature, page 2 The application shall be accompanied by: For module H and H1: the documentation concerning the quality system, see page 4 for details Specific for module H: See page 5 Specific for module H1: See page 6 The documentation shall be listed in a cover sheet or separate document. We prefer to have the documentation in pdf or similar. Page 1 (6) For RISE notering: Ankom den

The applicant confirms: That no application for conformity assessment of products covered by this application has been sent to any other Notified Body. That the applicant as the certificate holder allows RISE to publish issued certificates, in listings over certified products. That the applicant/manufacturer will keep him-/herself informed about any restrictions of the validity of referred standards and if necessary adjust the product(s) in order to adapt to the changed requirements. That the applicant/manufacturer has taken all relevant requirements stated in Directive 2014/32/EU in consideration. That the requirements for certification, as given in Certification Rules SPCR 302 will be followed. That the notified body (RISE) will, during the validity period of the certificate, be informed about changes of products before carried out (it may be necessary to perform new tests, make a review of accompanying documents or/and revision of the EC certificate/decision) the applicant/manufacturer during the validity period of the certificate will not make any changes of the product, without first contacting RISE. Specific for quality system assessment: That the applicant/manufacturer will fulfil the obligations arising out of the quality system as approved and to maintain it so that it remains adequate and efficient That the applicant/manufacturer shall keep the notified body that has approved the quality system informed of any intended change to the quality system. Place, date Signature of the person representing the company Clarification/name of the person representing the company This application together with relevant documentation refererred to in the application is sent to your contact person at RISE according to the model: first_name.last_name@ri.se and to certifiering@ri.se Regarding which information to appended see the following pages. Page 2 (6)

Information about the applicant Manufacturer (in accordance with the definition in MID article 4 (8) Company name: Full postal address: Authorised representative (in accordance with the definition in MID article 4 (9) Invoice address (if other than above) Visiting address: Org./VAT No.: Phone company: E-mail company: Internet (www): Contact person: Phone contact person: E-mail contact person: Manufacturing places: Information about the manufacturer (if other than applicant): Company name: Full postal address: Visiting address: Org./VAT No.: Phone company: E-mail company: Internet (www): Contact person: Phone contact person: E-mail contact person: Other information Page 3 (6)

For assessment of the quality system, the application shall be accompanied by : the documentation concerning the quality system: The quality system shall ensure compliance of the measuring instruments with the requirements of this Directive that apply to them. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic and orderly manner in the form of written policies, procedures and instructions. This quality system documentation shall permit a consistent interpretation of the quality programmes, plans, manuals and records. It shall, in particular, contain an adequate description of: (a) the quality objectives and the organisational structure, responsibilities and powers of the management with regard to design and product quality; (b) the technical design specifications, including standards, that will be applied and, where the relevant harmonised standards, and/or normative documents will not be applied in full, the means that will be used to ensure that the essential requirements of this Directive that apply to the measuring instruments will be met applying other relevant technical specifications; (c) the design control and design verification techniques, processes and systematic actions that will be used when designing the measuring instruments pertaining to the instrument category covered; (d) the corresponding manufacturing, quality control and quality assurance techniques, processes and systematic actions that will be used; (e) the examinations and tests that will be carried out before, during and after manufacture, and the frequency with which they will be carried out; (f) the quality records, such as inspection reports and test data, calibration data, qualification reports on the personnel concerned; (g) the means of monitoring the achievement of the required design and product quality and the effective operation of the quality system. (This text is an modified extract from Directive 2014/32/EU) Page 4 (6)

Specific for module H: the technical documentation, for one model of each category of measuring instruments intended to be manufactured. The documentation shall make it possible to assess the instrument s conformity with the relevant requirements, and shall include an adequate analysis and assessment of the risk(s). The technical documentation shall specify the applicable requirements and cover, as far as relevant for the assessment, the design, manufacture and operation of the instrument Contents of technical documentation as stated in Article 18 of Directive 2014/32/EU. The technical documentation shall, wherever applicable, contain at least the following elements: (a) a general description of the measuring instrument; (b) conceptual design and manufacturing drawings and plans of components, sub-assemblies, circuits, etc. (c) manufacturing procedures to ensure consistent production; (d) if applicable, a description of the electronic devices with drawings, diagrams, flow diagrams of the logic and general software information explaining their characteristics and operation; (e) descriptions and explanations necessary for the understanding of the information referred to in points (b), (c) and (d), including the operation of the measuring instrument; (f) a list of the harmonised standards and/or normative documents referred to in Article 14, applied in full or in part, the references of which have been published in the Official Journal of the European Union; (h) results of design calculations, examinations, etc.; (i) the appropriate test results, where necessary, to demonstrate that the type and/or the measuring instruments comply with the following: the requirements of this Directive under declared rated operating conditions and under specified environmental disturbances, the durability specifications for gas-, water-, thermal energy-meters as well as for liquids other than water; (j) the EU-type examination certificates or EU design examination certificates in respect of measuring instruments containing parts identical to those in the design. Reference RISE note Page 5 (6)

Specific for module H1: all relevant information for the instrument category envisaged the technical documentation, for one model of each category of measuring instruments intended to be manufactured. the supporting evidence for the adequacy of the technical design. This supporting evidence shall mention any documents that have been used, in particular where the relevant harmonised standards and/or normative documents have not been applied in full, and shall include, where necessary, the results of tests carried out in accordance with other relevant technical specifications, by the appropriate laboratory of the manufacturer, or by another testing laboratory on his behalf and under his responsibility. Contents of technical documentation as stated in Article 18 of Directive 2014/32/EU. The technical documentation shall, wherever applicable, contain at least the following elements: (a) a general description of the measuring instrument; (b) conceptual design and manufacturing drawings and plans of components, sub-assemblies, circuits, etc. (c) manufacturing procedures to ensure consistent production; (d) if applicable, a description of the electronic devices with drawings, diagrams, flow diagrams of the logic and general software information explaining their characteristics and operation; (e) descriptions and explanations necessary for the understanding of the information referred to in points (b), (c) and (d), including the operation of the measuring instrument; (f) a list of the harmonised standards and/or normative documents referred to in Article 14, applied in full or in part, the references of which have been published in the Official Journal of the European Union; (h) results of design calculations, examinations, etc.; (i) the appropriate test results, where necessary, to demonstrate that the type and/or the measuring instruments comply with the following: the requirements of this Directive under declared rated operating conditions and under specified environmental disturbances, the durability specifications for gas-, water-, thermal energy-meters as well as for liquids other than water; (j) the EU-type examination certificates or EU design examination certificates in respect of measuring instruments containing parts identical to those in the design. Reference RISE note Page 6 (6)