Magnetic, Incremental - Length Measuring System. Only functional with an ELGO MB R magnetic tape!

Similar documents
Magnetic Length Measuring System

FMAX SERIES. Installation manual. Guided Magnetic Absolute Linear Encoder. FMAX-000-E Doku Art. Nr

PMIS3 POSIMAG Magnetic Scale Position Sensor

Magnetic Linear Measuring System. MS01 Technical manual

BDD-UM 3023 Digital Display

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

LMA10 absolute magnetic encoder system

Technical Documentation

PU202 Level converter & encoder signal generator without potential separation

Operating Manual. GV210 Encoder distributor, cross switcher and splitter for incremental encoder signals. Product Features:

IF30. User's manual. Description. Table of contents IF30

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Operating instructions Fail-safe delay timer AZS About this document. Content

POSIROT. PMIS4, PMIR5 Magnetic incremental encoder. Magnetic wheels for rotative applications PMIS4, PMIR5

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Technical data sheet. 1. Manufacturer. 2. Product description. 3. Application areas. 4. Features. 5. Technical data

300 ma max. 2 mm ,8 mm. ±1 mm. ±1 Digit. A, A, B, B / signal Z, Z (optional) / status signal ERR (optional) Zinc die casting IP67

ULTRASONIC. Ultrasonic Distance- and Proximity Sensors. UFA-1500 Series. Key features:

Operating instructions Electronic level sensor LK / / 2008

More Precision. mainsensor // Magneto-inductive displacement sensors

Synergy RJ45 LCS 6 Category 6 data outlets

ECM3 EARTH CONTINUITY RELAY

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Installation and Operational Instructions for ROBA -switch Type 017._00.2

SCHMIDT. VibroSens 401. Operating Instructions

Original operating instructions Fail-safe inductive sensor GG507S

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Magnetic Inductive Flow Sensor induq

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

FLUXGATE COMPASS. Product reference : USER GUIDE. and INSTALLATION GUIDE. nke Sailing competition

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

BML-S1F_-A/Q _-M _-_0-KA Magnetic Linear Encoder System. User's Guide. Magnetic Linear Encoder System BML-S1F_-A/Q _-M _-_0-KA

PMIS2 POSIMAG Magnetoresistive Position Sensor with Incremental Output

Installation and Operating Instructions for Phase Demodulator Type _.2

TURCK Capacitive Sensors - Principles of Operation

Process/Mini. English IMPORTANT NOTE. Installation and Operation Manual. General Purpose Light Curtain with 30 mm resolution

special stepper motor

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

Torque Sensor Series 3000 and Series 4000

SI251 SinCos interpolator for encoders and measuring systems with SinCos output

Distance-setting Photoelectric Sensor

LVDT. Inductive Position Transducer. SLX-series. designed for pharmaceutical, medical and food industry. content: Key-Features:

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

30XR-A Professional Digital Multimeter Users Manual

EMS THOMAS WÜNSCHE. CANwatch. CAN Physical Layer Analyser. User Manual. Documentation for CANwatch version 1.2. Documentation date: November 2004.

Magnetic sensor MSK5000 Incremental, digital interface, resolution 1 μm, scaling factor

LVDT. Inductive Position Transducer. SL Series. Key-Features:

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

XT Technical Documentation. The magnetostrictive level sensor. Edition: Version: 1 Article no.:

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

Magnetic sensor MSK320 Incremental, digital interface, resolution 12.5 μm, scaling factor 64 1

User s Manual For CT Model IMB

Installation and Operational Instructions for ROBA -switch Type 017._00.2

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Series 7000 Torque Sensor for PTO-shafts

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Telemetrie-Messtechnik Schnorrenberg

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

Installation Instructions RF-identification system Read/write head ANT513

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

INSTALLATION & OPERATING INSTRUCTIONS

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

Screens INTRODUCTION OPERATION. Quadrature Counting

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

NUMERIK JENA. LIA Series. Exposed Linear Encoder with Signal Control

Strain gauge amplifier

Junction Box JB6101- (000) Installation and Operation. Manual DV Issue 1 June 2012

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Motor spindle Operating Instructions. Ref

NUMERIK JENA LIK 21 LIK 22 LIK 23. Exposed Linear Encoders compact model range

Projected Capacitive Touchscreen DUS series Product Specification. Document No. DEC-S0041A

External brake resistor AX2090-BW5x

Distance-setting Photoelectric Sensor

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Analogue Demo Multimeter ADM

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

MONORAIL AMS. Integrated Linear Distance Measuring System

Digital Electronic Thermostat With RF

Heiland electronic GmbH TD / TD1 / TD2. B&W-Densitometers. USERS MANUAL Version 5

LENORD. +BAUER... automates motion. GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter

INA 703 MAgNetIc field coil

Visit us at

ULTRASONIC. Ultrasonic Distance and Proximity Sensors. UFA-1500 Series. Key features:

Original operating instructions Fail-safe inductive sensor GM705S

Functions module / Gateways Application Description Product Page KNX-GW-DMX-xxx DMX Gateway. KNX-GW-DMX Product Group 1

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

V6 V10 V35 V45 V218-S V221-S

Proximity Sensor Terminology

SUNRISE UPGRADE KIT for LAI "SkillTester"

PROXIMITY SENSOR TERMINOLOGY

Directional valves Electrically operated Series 563, 565, 567. Brochure

Transcription:

GMIX1A Series Magnetic, Incremental - Length Measuring System 5 different adjustable resolutions between 0.1 and 0.01 mm s (at 4 edge triggering) repeat accuracy +/- 1 increment 5V-TTL or 10...30 V Push/Pull outputs selectable Only functional with an ELGO MB20-50-10-1-R magnetic tape! GMIX1A-standard-E_05-04 Doku Art. Nr. 799000015

Contents: 1. Introduction 3 2. Adjustments 3 2.2 Adjustment of output levels 4 2.3 Speed monitoring VMAX 4 2.4 Adjustment of VMAX act-direction 4 2.5 Setup of resolution 4 3. Signal LED s 4 3.1 Flashing sequences of status LED s 5 4. Speed monitoring (VMAX - output) 5 5. Safety 6 5.1 Interference suppressions 6 5.2 Place of installation: 6 6. Connections 7 7. The Magnetic Tape MB20-50-10-1-R 7 8. Dimensions 9 9. Affection tolerances of sensor 9 10. Technical specifications 10 11. Type designation GMIX1A 11 12. Liability exclusion / Guarantee 12 2

1. Introduction The GMIX1A is an incremental measuring system, which is used for the measurement of lengths and distances. The translator is accommodated in a separate box, in which the spent square-wave pulses are signaled by LED s. A further LED serves for the announcement of the operating status. Different adjustments can be done with the internal 6 pin DIL-switch: Output levels (TTL- Line driver or 24 VDC push/pull) The configuration of speed monitoring VMAX The resolution of the measuring system 2. Adjustments In order to be able to change the adjustments, the cover of the evaluation box must be removed before. Loosen for this the 4 cross-notched screws on the top side and then remove the cover. With the 6 pin DIL-switch the settings can be done. DIL-switch for adjustments 3

2.2 Adjustment of output levels DIL-switch OFF ON 1 TTL- Line driver 24 V push/pull 2.3 Speed monitoring VMAX DIL-switch OFF ON 2 deactivated activated 2.4 Adjustment of VMAX act-direction DIL-switch OFF ON 3 (see page 5/ chapter 4.) with positive counting direction with negative counting direction positive negative 2.5 Setup of resolution Resolution (in mm s) DIL-switch 0,1 0,05 0,025 0,02 0,01 4 ON OFF ON ON OFF 5 ON ON OFF OFF OFF 6 ON ON ON OFF OFF With appropriate indication in the order (see last side "Type designation ) the desired configuration will be made by factory. 3. Signal LED s The LEDs at the translator box signals as follows: green Status = Diverse flashing sequences (system status) red red A B red 0 = On if signal output of channel A = On if signal output of channel B = On if signal output of channel Z With very slow frequencies the red LED's shines not statically, but flashes. 4

3.1 Flashing sequences of status LED s On the basis of following representation the flashing sequences of status LED are assigned to the different operating conditions: 4. Speed monitoring (VMAX - output) VMAX activated (DIL-switch 2 = ON ): The output VMAX (on supply potential) switches off the voltage (wire break security) if the operating speed of 25 m/min is exceeded, according to the adjusted act-direction (see 2.4 on page 4). This will signaled by the status LED with the associated flashing sequence (see above). After a time of 60 seconds the output VMAX will be reset. Signaling of exceeding the speed limit over the status LED is only deactivated after putting a procedure distance back by 200 mm in positive or negative counting direction. VMAX deactivated (DIL-switch 2 = OFF ): The exit VMAX is permanently on the supply potential. The monitoring of the operating speed is not active. 5

5. Safety Attention! To ensure a perfect function of GMIX1A the following installation guidelines must be strictly observed and followed. Otherwise the guarantee expires and ELGO Electric GmbH takes no liability and guarantee for malfunctions or damages caused e.g. by incorrect installed wires or other external sources of error or interference, which are exactly explained below. Please read the instructions carefully before putting the controller into operation. As well the company ELGO Electric GmbH is not responsible for possible machine and/or personal injuries, which can result from incorrect material at the measuring system and follow-up electronics. The machine manufacturer is obligated to accomplish safety-relevant measures The type-label on the translator box serves for the exact identification of the measuring system. There is about the exact type designation (see chapter 10. on page 10), the delivery date and the manufacturing number. These datas are also helpfully at service calls and other contacts with ELGO company. 5.1 Interference suppressions The screen of the signal cables should be connected only on one side with follow-up circuits. The signal output cable is to be laid in principle separately from load current lines and a distance from at least 0.5 m to inductive and capacitive interference sources like contactors, relays, engines, switch power packs, clocked automatic controllers etc. must be kept. If disturbances should arise despite adherence to all points described above, must be proceeded as follows: Attach from RC elements over contactor coils of AC contactors (e.g. 0,1 µf / 100 Ω). Attach recovery diodes over DC inductances. Attach from RC elements over the individual engine phases and over the brake (in the terminal box of the engine). 5.2 Place of installation: Principle install GMIX1A separately from load current lines. A distance from at least 0.5 m to inductive and capacitive interference sources like contactors, relays, engines, switch power packs, clocked automatic controllers etc. must be kept. Lay the GMIX1-cable separately from load current lines and keep distance to interference sources. When assembling in the proximity of foreign magnets a minimum distance from 100 mm is necessary to the magnetic tape. 6

6. Connections The 9 pin D-SUB connector is assigned as follows: Pin Function 1 A 2 A 3 0 V - GND 4 B 5 B 6 VMAX 7 Z (Index pulse) 8 10...30 VDC 9 0 V - GND Erläuterung: A, B, Z = normal tracks A und B = inverted tracks VMAX see page 5 chapter 4. 7. The Magnetic Tape MB20-50-10-1-R The ELGO magnetic tape consists of three components: Sensor side C A B 1.8mm Mounting side 10mm L Deliverable Lengths 0.5 32 m, other length on request A The magnetized, highly flexible rubber tape, connected on the bottom with: B A magnetized, flexible steel tape. This steel tape protects the rubber tape from mechanical damages and is at the same time a magnetic short circuit. This increases significantly the functional security under extreme magnetic influences. A and B are already factory-bonded (by ELGO). C To keep the flexibility for transport and installation, the third part, also a steel tape (magnetic permeable), is delivered separately. It serves for mechanical protection of the rubber tape and must be stuck on the magnetic rubber tape after installation. 7

7.1 Processing hint for the sticking of magnetic tapes Materials to stick: The provided sticky tapes stick well on clean, dry and plain surfaces. Typical solvent for cleaning surfaces are a 50/50 mixed isopropyl-alcohol / water mixture or heptane. (Important: Please observe carefully the caution hints of the producer when using the solvent.) The surfaces of materials as copper, brass etc. should be sealed to avoid an oxidation. Proof: The stability of the adhesion is directly depending on the contact, which the adhesive develops to the stick together surfaces. A high proof results in a good surface contact. Sticking temperature: The optimal sticking temperature is between + 21 C and 38 C. Avoid colder sticking surfaces than + 10 C, because in this case the adhesive becomes to hard and perhaps a sufficient immediate adhesion is hardly to achieve. After proper sticking the stability of the connection is ensured also when the temperature is below zero. The final tackiness of a sticking is from experience reached after approximately 72 hours (at + 21 C). Magnetic rubber tape Steel tape Important! To avoid tensions in the tape, it should be stored racked or unrolled with the magnetic rubber tape to the outside. Sensor side Covering band (to protect the magnetic tape not necessary for measurement). Magnetic tape consisted of magnetized synthetic tape (above) and steel tape (below) Installation area (machine base etc.) Resistance to chemicals of the magnetic tape Chemicals, showing no or only a small effect: -formic acid -glycerol 93 C -linseed oil -soy beans oil -cotton seed oil -N-hexane -lactic acid -formaldehyde 40% -isooctane -petroleum Chemicals, showing small to medium effect: -acetone -gasoline -acetic acid 30% -Olein acid -acetylene -steam -acetic acid, pure acetic acid -sea water -ammonia -acetic acid 20% -isopropyl ether -stearic acid 70 C anhydrous -kerosene Chemicals, showing strong effect: -benzene -nitric acid 70% -turpentine -toluene -lacquer solvent -nitric acid, red, vitriolic -carbon tetrachloride -trichloroethane -nitrobenzene -hydrochloric acid 37%, 93 C -tetrahydrofuran -xylene 8

8. Dimensions 74 4,5 Translator box 106 106 116 10 28 1,5 Sensor head Bottom X = active sensor area Width = 10 mm 9. Affection tolerances of sensor 1) +/- 3 mm 2) < +/- 5 3) < +/- 5 4) < +/- 1,5 Abstand Gap max. max. 2,0 0,8 mm Magnetband 1.5 mm Magnetic tape 9

10. Technical specifications Sensor Length of sensor cable 3 m Protection class IP 67 Operation temperature: 0... + 50 C Bending radius of sensor cable: min. 60 mm Housing material: Die cast zinc Allowed distance to the magn. tape max. 1.5 mm Magnetic tape Operation temperature: 0... + 50 C Linear expansion coefficient: 16 x 10 6 1/K Bending radius: min. 150 mm Translator box Power supply: Consumption: Output signals: Resolution: 10 30 VDC max. 300 ma selectable TTL- Line driver or 24 VDC push/pull 5 adjustable resolutions (0.01...0.1 mm) at 4 times edge multiplier +/- 1 increment +/- (0.025 + 0,02 x L) L = effective measuring length in m 0... + 50 C Zinc-plated sheet Repeating accuracy: Accuracy at 20 C in mm s: Operation temperature: Housing material: Protection class: IP 40 EMC-Generic standard NS 73/23/EWG EMV 89/336/EWG Output VMAX (Pin 6) Output voltage: Consumption: Other: Power supply voltage (10...30 VDC) 0,7 V max. 200 ma (Ohm's, inductive or capacitive load) Output is durable short circuit proofed and current limited 10

11. Type designation GMIX1A GMIX1A - XXX - XX.X - X - XX Series Magnetic, incremental length measuring system Version 000 = standard 001 = first special version Length of sensor cable in meters Resolution (if pre-setting desired) 1 = 0.1 mm s 2 = 0.05 mm s 3 = 0.025 mm s 4 = 0.02 mm s 5 = 0.01 mm s Power supply / Output levels (if pre-setting desired) 00 = 10-30 V / 10-30 V Push/Pull 01 = 10-30V / TTL- Line driver Magnetic tape (accessories) MB20-50 - 10-1- R- XX.X ELGO Magnetic tape Pole distance 5.0 mm Width 10 mm Number of magnetic tracks 1 = Single track system Tape construction R = Standard Tape length Please indicate the desired Length in XX.X Meters 11

12. Liability exclusion / Guarantee We have checked the contents of this instruction manual carefully, to the best of our knowledge and belief for conformity with the described hardware and software. Nevertheless errors, mistakes or deviations can not be excluded, therefore we do not guarantee complete conformity. Necessary corrections will be included in the subsequent editions. We appreciate your ideas and improvement suggestions very much. Reprint, duplication and translation, even in extracts, are only allowed with a written authorization by the company ELGO Electric GmbH. We constantly strive for improving our products, therefore we keep all rights reserved for any technical modifications without any notice. ELGO Electric does not assume any liability for possible errors or mistakes. The guarantee period is one calendar year from the date of delivery and includes the delivered unit with all components. ELGO Electric GmbH will at its option replace or repair without charge defects at the unit or the included parts, verifiable caused by faulty manufacturing and/or material in spite of proper handling and compliance to the instruction manual. Damages verifiably not caused by ELGO Electric GmbH and due to improper handling are excluded from any guarantee e.g. by applying faulty voltage, diffusion of liquid into the interior of the engine, using force, scratching the surface, chemical influences etc.! Subject to modifications - ELGO Electric GmbH 2004 12