ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

Similar documents
1. SUMMARY 2. SPECIFICATION 3. WIRING. 3.3 Power Input Voltage Selection. 3.1 A to C: Sensing Input. 3.2 B to C: Power Input

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

ADVR-16. Hybrid Universal Analog Digital Voltage Regulator Operation Manual. Self Excited 16 Amp Analog / Digital Voltage Regulator

Using the VR448 in place of the Marathon DVR 2000

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

EA05A. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator 5 Amp AVR For General Generators

Generator AutomaticVoltageRegulator OperationManual

EA06 (220V) Generator Automatic Voltage Regulator Operation Manual

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

R180. AVRs. Installation and maintenance

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES

ADVR-2100M. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 R150. AVRs. Installation and maintenance

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

Current Draw (Circuit breakers and fuses blow. Burning smell or smoke)

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

R448 & R448 V50 A.V.R.

Exercise 1: The DC Ammeter

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Trouble Shooting MagnaPLUS / Mariner / Harsh Duty

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

SPECIFICATION, CONTROLS AND ACCESSORIES

MTC-2 highlight features: ACU highlight features: Contents. MTC-2 and ACU User Manual V5.1

R1 Q2 Q1 F2 F1 N A1 A2 FUSE V AC S UF OE SL UF OE R150 A.V.R. R150. Installation and maintenance

Operation and Maintenance Manual

V S UF OPEN IN 60Hz OE UF SL R120 V N1 U N F1 F2 A.V.R. R120. Installation and maintenance

M40FA640A/A - Mark I. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators. (Issued: 04.

R / 8000 RAPIDE FAST RAPIDE 3 PAHASES SENSING SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000 LSA 46 / 47

ENGINE GOVERNING SYSTEMS LSM200 SERIES LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

M16FA655A - Mark V. User Manual SIN.NT Automatic Voltage Regulator for Three-phase Synchronous Generators

ELECTRONIC REGULATOR FOR OPEN LOOP

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. REQUEST A QUOTE

DynaDrive INFORMATION MANUAL SDFP(S)

MTC-2 highlight features: ACU highlight features: Contents. MTC-2 and ACU User Manual V4.0

The Vibrator Power Supply

R450 T DETECT. 3 PH 3 PH. SENSING 7000 / 8000 RAPIDE FAST RAPIDE VOLTAGE 80V ~ 320V SHUNT / AREP SERIES PMG NORMAL NORMAL NORMAL NORMAL 5000 / 6000

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

GX 600 SERIES (AUTOMATIC VOLTAGE REGULATOR)

Rev.8 03/08 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2008 NUWAVE TECHNOLOGIES, INC.

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2547 UNIVERSAL AMPLIFIER MODULE

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide

INTEGRATED CIRCUITS. AN120 An overview of switched-mode power supplies Dec

DLVP A OPERATOR S MANUAL

GX 340 SERIES (AUTOMATIC VOLTAGE REGULATOR)

R438 A.V.R. R438. Installation and maintenance X2 Z1 X1 Z2 E+ E- 0V REQUEST A QUOTE

MTC-2 highlight features: ACU for Flakpanzer Gepard highlight features: Contents. MTC-2 and ACU User Manual V4.2 (Flakpanzer Gepard Version)

15P0161B1 - DCREG for Applications to Electromagnets - SW Rev. D3.09 R.03 - Updated 01/04/04

MP MHz, 700mA, Fixed-Frequency Step-Up Driver for up to 10 White LEDS

MODEL KBWD-15 Pulse Width Modulated (PWM)

AD-8100 & AD-8200 Servo Amplifiers

MODEL 421 Over/Under Motor Load Monitor

Industrial motor controller for brushed DC motors 24 VDC

6.9 Jump frequency - Avoiding frequency resonance

Industrial motor controller for brushed DC motors 12 VDC

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

Four Channel Inductive Loop Detector

Single Phase Soft Starters

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

RS2012 Low Power OFF-Line SMPS Primary Switcher

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

CR6853. Novel Low Cost Green-Power PWM Controller With Low EMI Technique

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2844 PID CONTROLLER WITH FEED FORWARD COMPENSATION

Cover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features

EVC600C User Manual EVC600C SERIES. EVC600C User Manual. Date Version Note. Version. Page 1 of 6. Ver 1.

AC/DC ELECTRICAL SYSTEMS

P. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

Data Sheet. Stepper Motor Drive Boards. Features

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

YB1522 Step-up DC-DC Converter White LED Driver

Back to the Basics Current Transformer (CT) Testing

D I G I T A L V O L T A G E R E G U L A T O R

User s Manual for Integrator Short Pulse ISP16 10JUN2016

PWM regulator for electrolysis cell Η 2

Experiment 6. Electromagnetic Induction and transformers

Special Internal Circuits

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Instruction MI December Magnetic Flow System

Pin # Pin Name Pin Type Description

SCHEMATIC OF GRAYMARK 808 POWERED BREADBOARD

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

USER'S MANUAL DMR-4350

TECHNICAL INFORMATION edition 1.02 FOR TRANSISTOR-FOUR-QUADRANT SERVO-AMPLIFIER SERIES MTR /5-15

Ledex Drive Electronics and Coil Suppressors

Sealed Interface Control: EC20300

The 6LE8 One Tube Broadcaster

Transcription:

ADVR-053 Hybrid Universal Analog Digital Voltage Regulator Operation Manual Self Excited 5 Amp Analog/Digital Voltage Regulator For shunt and auxiliary windings generators With over-excitation and lost of sensing protection

1. SUMMARY The ADVR-53 is an advanced (Hybrid Analog/Digital Voltage Regulator) designed for general-purpose isochronous stand along applications. The ADVR-053 uses an extremely reliable CPU (Central Processing Unit) in its design. This eliminates complex analogue components and circuits that are inherently over sensitive to temperature anomalies, as a result, eliminating voltage instability and drift. In addition, we added over excitation and loss of sensing shutdown protections, with matching, O/E LED indicator lights. Consequently, this ADVR prevents the generator from excitation overload, with its resulting exciter and regulator damage. It is easy to install and flexible for use in both shunt type and generators with auxiliary windings. A high quality substitute that easily takes the place of a large number of AVR models, plus improving the overall performance of the generator. 2. SPECIFICATION Sensing Input Voltage Frequency Power Input Voltage 170 to 520 VAC, 1 phase 2 wire DIP switch selectable 50 / 60 Hz, DIP switch selectable 100 to 300 VAC, 1 phase 2 wire Output Voltage Max. 63 VDC @ 220 VAC input Current Continuous 5A Intermittent 7A for 10 sec Resistance.15 to.100 ohm Voltage Regulation < ± 0.5% ( with 4% engine governing ) Voltage Build-up Residual voltage at AVR terminal > 5 VAC Thermal Drift 0.03% per C change in AVR ambient External Volts Adjustment 7% with 1K ohm 1 watt trimmer EMI Suppression Internal electromagnetic interference filtering Unit Power Dissipation Max. 8 watt Under Frequency Protection (Factory Setting) At 60 Hz- knee point set at 55 Hz At 50 Hz - knee point set at 45 Hz Over Excitation Protection 78 ±5VDC @220VAC 5sec Soft Start Ramp Time 3 sec. Dimensions 107mm L * 75mm W * 48.5mm H 4.25 L x 3 W x 2 H Weight 220g 8oz ± 2% 3. WIRING 3.1 A to C: Sensing Input DIP SW-2 switch ON, voltage sensing range from 170 to 260V (See Fig. 2 & 3) DIP SW-2 is switch OFF, voltage sensing range from 340 to 520V (See Fig. 4) 3.2 B to C: Power Input Power Input terminals from B to either C use 100 to 300VAC shunt or auxiliary windings. 3.3 Power Input Voltage Selection If generator rated voltage is 220VAC (Line to line phase voltage), the power input B, C and sensing input A, C can be joined (See Figure 3) or separately (See Figure 2). 2 ADVR-53

3.4 F+, F Connect generator field wires F+ and F- are the positive and negative excitation output terminals EXT.VR is the connections for the external voltage adjustment. Use a (1KΩ 1W) Rheostat When not in use, keep terminals shorted * Always use high quality connection wire AWG16 or 1.25mm 2 85-degrees C, 600V to connection terminals A, B, C, F+ and F 4. DIP SWITCH SETTINGS 4.1 SW-1 Frequency DIP SW-1 switch ON, for use in 50 Hz DIP SW-1 switch OFF, for use in 60 Hz 4.2 SW-2 Sensing Voltage Selection DIP SW-2 switch ON, input voltage 170 to 260V DIP SW-2 switch OFF input voltage 340 to 520V 4.3 SW-3 Activate Over-Excitation Protection DIP SW-3 switch ON, Over Excitation Protection DISABLED. If over excitation occurs, the O/E LED turns-on, but the ADVR will not shutdown and protect. DIP SW-3 switch OFF. Over Excitation Protection ACTIVATED. If over excitation occurs, the O/E LED turns-on and the ADVR will shutdown excitation. 5. System Protections 5.1 Under Frequency Protection (Roll off) To prevent over excitation, if the generator runs at the wrong speed the ADVR activates the under frequency protection and decreases field excitation Dip switch 1 together with the adjustment, sets the Knee-Point frequency were this activation takes place. This adjustment is already factory preset. When engine frequency falls under the Knee-Point frequency setting, the protection indication LED turn on. However, when the Generator frequency is higher than the Knee-Point frequency the LED turns off. If you are using a standard AVR and you overload the generator or the sensing wires get disconnected (on a auxiliary powered AVR), the excitation voltage rapidly increase, causing severe damage to the AVR or exciter. The ADVR-053 has over excitation protection shutdown that cuts excitation at once. When over excitation protection is activated and the excitation voltage exceeds 78 ±5VDC @220V for over 5 seconds, the AVR immediately shutdown the excitation output, leaving only the residual voltage output and turning on the O/E shutdown LED. To reset, the engine must come to a complete stop for at least 10 seconds and then restarted. If over excitation protection is disabled, the warning LED indication turn on, but the excitation output is not disconnected. 6. ADJUSTMENTS 6.1 VOLT: Voltage Adjustment DIP SW-2 switch ON, input voltage 170 to 260V DIP SW-2 switch OFF input voltage 340 to 520V 6.2 STAB: Stability Adjustment careful adjust the STAB (Stability) adjustment, improves the AVR and generator feedback time to improve voltage stability. 6.3 : Setting the under-frequency knee point DIP SW-1 set on OFF, set for 60Hz operation adjustment range at 60Hz is from 50 to 60Hz (Factory preset @ 55Hz) DIP SW-1 set to ON, set for 50Hz operation adjustment range at 50Hz is from 40 to 50Hz (Factory preset @ 45Hz) 5.2 Over Excitation Protection ADVR-53 3

7. Startup Adjustment 7.1 Voltage Adjustment (VOLT) Set VOLT and STAB full CCW. Start generator and wait until it reaches rated frequency. Slowly adjust VOLT CW to its rated voltage. If you are using an external VR, set it first to its center position before setting volts. 7.2 Stability Adjustment (STAB) If the generator voltage oscillates back and forth, adjust the STAB to steady the output voltage. Over adjustment, CW may give you large voltage swings when changing loads, Use an analog type voltmeter when setting STAB. Connect the voltmeter to terminals F+ and F? and slowly adjust STAB for minimum needle movement when varying load. 7.3 Under Frequency Adjustment () To adjust the setting, select working HZ using DIP SW 1, start the engine and adjust engine speed to either 55Hz or 45Hz slow adjust until the red LED turns ON. Returning the engine speed back to normal turns the LED light off. 8. Flashing When setting up the AVR for the first time, the polarity of the residual magnetism may be reversed or too weak to operate the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than 5 VAC, shut down the engine and continue with the following steps Stop the generator and disconnect the field wires (F+ and F?), apply a DC Voltage (3 to 12VDC) using a car batteries positive to terminal F+ and battery negative to terminal F?, using a current-limiting resistor from 3 to 5 ohms 20 watt. (See Figure 5) Flash for 3 seconds before removing the battery. reconnect the voltage regulator, now voltage build-up should be successful. If the voltage is still less than 5VAC, repeat steps 7.1 and 7.2. If residual voltage is greater than 5VAC, but still unable to build up voltage output, replace with a new voltage regulator. WARNING Excessive field flashing may cause damage to the AVR or the generator exciter coil. Partial list of regulators this model can substitutes. Keep in mind ADVR-053 does not work in paralleling. This list is for reference only. The names of the original equipment Manufactures is only a guide and not meant as a recommendation from any of this manufactures. SE350 Marathon SE100 Marathon SR7 Mecc Alte UVR6 Mecc Alte APR63-5 Basler VR63-4 Basler AVC-63-4 Basler KR4FF Basler SX460 Newage SX440 Newage AS440 Newage E000-24600 Newage E000-24602 Newage E000-24030 Newage VR3.1 Koncar M16FA655A Merelli GRT7-TH4 WEG GRT7-TH4E WEG GRT7-TH5 WEG 230 Leroy Somer (change wires sensing to 220v) (22-192 FG Wilson (change wires sensing to 220v) Disconnect the AVR AC power input terminals and restart the generator, measure the residual voltage. If this voltage is now greater than 5VAC, 4 ADVR-53

9. TROUBLE SHOOTING SYMPTOM No Voltage Output Low Voltage Output Blown Fuse Over Voltage Output Unstable Voltage Output * Use only original replacement fuse CAUSE Engine under speed Low residual voltage B, C, F+, F, Terminal connection not properly connected Defective generator A, C, B, C, Terminal incorrect connection Defective VR or not properly connected Under frequency Incorrect exciter specification AVR Incorrect voltage selected Over excitation current / incorrect wiring A, C, terminals not properly connected or incorrectly connected AVR Incorrect voltage selected STAB Stability incorrectly adjusted CORRECTION refer to generator service manual refer to section 7 Flashing Reference from Figure 2 to Figure 4 refer to generator service manual Reference from Figure 2 to Figure 4 Check connection and VR refer to generator service manual refer to generator service manual refer to section 3 DIP Switch setting Reference from Figure 2 to Figure 4 Reference from Figure 2 to Figure 4 refer to section 3 DIP Switch setting refer to section 5 Adjustment * We can modification or change performance specification or appearance without prior notice. ATTENTION 1. AVR can be mounted directly on the engine, genset, switchgear, control panel, or any position that will not affects operation. For dimension reference, see Fig 1. 2. All voltage readings are to be taken with an average-reading voltmeter -- Meggers and high-potential test equipment must not be used. Use of such equipment could damage the AVR. 10. Demencional Fig. 1 STAB VOLT F- F+ A B C EXT.VR SW Units : mm ADVR-53 5

N (T9) (T8) (T7) G ~ 220V 208v 220v 240v F- F+ A B C EXT.VR SW Fig. 2 STAB VOLT SW-2 ON 170 to 260VAC N (T9) (T7) G ~ 220V 208v 220v 240v F- F+ A B C EXT.VR SW Fig. 3 STAB VOLT SW-2 ON 170 to 260VAC 6 ADVR-53

N (T3) N (T1) ~ G 480v F- F+ A B C EXT.VR SW Fig 4 STAB VOLT SW-2 OFF 340 to 520VAC 20~200 OHM SWITCH DIODE BATT. F- F+ A B C SW Fig 5 STAB VOLT Flashing Circuit EXT.VR ADVR-53 7

N ~ G F- F+ A B C Fig 6 STAB VOLT EXT.VR SW SW-2 OFF 340 to 520VAC N ~ G F- F+ A B C STAB VOLT EXT.VR SW Fig 7 SW-2 ON 208 to 240VAC 8 ADVR-53