Solar Mounting Solutions. Series 100 Residential Roof Mount System Installation Manual. snapnrack.com Listed PV Mounting System

Similar documents
PV Mounting System 2703 SERIES 100 UL ROOF MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 100 UL ROOF MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

SolarMount (E)volution

BLACK WIDOW COMPOSITE

ROOF MOUNT. *Class A* Fire Rated INSTALLATION MANUAL

AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS

Patented Rail-Free Mounting System for Composition/Asphalt Shingle Roofs

ROOF MOUNT. *Class A* Fire Rated INSTALLATION MANUAL

UPDATED REV.5 BLACK WIDOW. Detailed installation manual. Patent pending P/N: BW-S, BW-B, BW-F.

INSTALLATION GUIDE FRAME MICRORAIL PUB2017JUL18

Dura-Lock Roof System

orientation Conergy SunTop Instructions for professional installation

May 14, Installation Manual

ATLANTIS RAIL Contact Information

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

Series 100 Roof Mount

Quick Hook SS & LS Standard and Low Height Hooks for Side Mount Rails

YUKON PATIO COVER INSTALLATION INSTRUCTIONS

SunPower Installation Manual

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue

1 of 9 SITE PLAN modules at 325W kw. Sample GAMECHANGE SOLAR. Sample. Sample AERIAL VIEW. Array Information. Design Information.

CSS Central Mount System

SolarWedge. Installation Manual Date Modified: 9/17/07 WARNING SAFETY. Tool List

EZ Tile Hook System. SunModo PV Rack Mount System UL2703 Compliant

Quick Hook SB & LB Standard and Low Height Hooks for Bottom Mount Rails

Installation Manual Flat Track Series

SILVERBACK INSTALLATION MANUAL

PV MOUNTING SYSTEM INSTALLATION MANUAL

Assembly Instructions 10 X 10 Aluminum Frame Building

Rayport G Eco Dealer Kit

SRIS-001 Arista Mounting System Instruction Sheet Solar Rooftop Support Ballasted

TREX PERGOLA INSTALLATION INSTRUCTIONS

Pickup Box Utility Rack Package Installation (Instruction ID: )

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Roof Mount Ground Mount Specialised Clamps Spares Application Notes

Connect Transit Shelter

Horizontal Cable Systems

Oxford Stalls Installation Instructions

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Flush Mount. SunEarth Flush Mount Installation Manual. SunEarth Flush Mount. Asphalt Shingle Roofing

POWER PEAK TM ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation. Version 1, Rev D P/N

Assembly Instructions for model: VMPR1

INSTALLATION INSTRUCTIONS for the JOMY RETRACTABLE LADDER. If there are any questions, please call (800)

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

INSTALLATION INSTRUCTIONS

Assembly Instructions 10 X 10 Aluminum Roof Support

3,500/4,500lb. Vertical Cable Feighner Lift

installation guide 1 GUIDE#: pwb-assault-004

Installation Instructions

INSTALLATION INSTRUCTIONS

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Installing flat panels on the MPL15 wall mount

Installation Guidelines

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

installation guide 1 GUIDE#: pwb-assault-001

Horizontal Cable Systems

Pow-R-Feed Systems Service Manual

Ekoroof LiteTile Dimensions

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

Installation Guidelines

Installation Instructions

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

The following instructions will guide you through the installation of your new vinyl railing.

FOR PROFESSIONAL GARAGE DOOR INSTALLERS

STYLE BAR & TONNEAU COVER INSTALLATION

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

U.S. Rack, Inc Falcon Drive, Madera, CA APR17 INSTALLATION AND USE INSTRUCTIONS for SIDE-MOUNT LADDER RACK

Installation Instructions - Model V4JSD 1

INSTALLATION MANUAL PBL-UMP

Roof Rack Installation Instructions

PREPARATION & TOOL CHECK LIST

1. TOOLS + MATERIALS REQUIRED

Installation Manual XRL Solar Rail System

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

PARTS INCLUDED IN FIXED STAIR CABLE RAIL KIT:

Installation Instructions

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

Mounting system for sloped composite shingle roofs with solar panels in portrait orientation

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Installation Instructions for. Before You Begin TOOLS REQUIRED

JEEP JK ( 5 DOOR ) SLIMLINE II - FULL TRAY EXTREME RACK KIT

INSTALLATION INSTRUCTIONS

THE ROGUE TM FUNSLIDE TM

ATLANTIS RAIL HandiSwage Installation Instructions ATLANTIS RAIL Contact Information Atlantis Rail Systems November, 2013

Tuff-Rib Install Guide

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

PREPARATION & TOOL CHECKLIST

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Side and rear window, assembly overview

Assembly Instructions

MobileTrak5 Installation Instructions

HONDA RIDGELINE (KIT #601) Installation Instructions (to be used in addition to owners manual)

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Rayport G Eco Ballasted

Vinyl Gazebo Instructions

Transcription:

Solar Mounting Solutions Series 100 Residential Roof Mount System Installation Manual 2703 Listed PV Mounting System

An Intro to SnapNrack Series 100 SnapNrack Series 100 PV Mounting System offers a low profile, visually appealing, photovoltaic (PV) module installation system. This innovative system simplifies the process of installing solar PV modules, shortens installation times, and lowers installation costs. SnapNrack systems, when installed in accordance with this manual, will be structurally adequate for the specific installation site and will meet the local and International Building Code. Systems will also be bonded to ground, under SnapNrack s UL 2703 Listing. The SnapNrack installation system is a set of engineered components that can be assembled into a wide variety of solar mounting structures. It is designed to be installed by qualified solar installation technicians. With SnapNrack you will be able to solve virtually any PV module mounting challenge.

Table of Contents Step 1: Project Plans Certification Details......................................... 1 Component Details......................................... 3 Pre-Installation Requirements...................................... 7 Step 2: Roof Attachment L Foot Mounts........................................... 11 Standoff Mounts.............................................. 13 Standoff Mount Options................................. 15 Universal Tile Hook.............................................. 19 Flat Tile Hook.............................................. 23 Hanger Bolt.............................................. 26 Metal Roof Base.............................................. 28 Corrugated Straddle Block.................................. 30 Tilt Mount.............................................. 32 Seam Clamp...................................... 36 Step 3: Rail Installation Installing and Leveling Rails.................................................. 39 Step 4: Module Installation Module Installation................................. 43 Rail Finishing................................. 47 Step 5: Select Any Racking Accessories Array Edge Screen.............................................. 49 Wire Management.............................................. 51 MLPE Installation.............................................. 54 Grounding Specifications.............................................. 57 List of Approved Modules.............................................. 62 Mechanical Loading Specifications..................................... 65 List of Approved Modules.............................................. 68

Certification Details SnapNrack Series 100 system has been evaluated by Underwriters Laboratories (UL) and Listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. Grounding/Bonding The Series 100 system has been designed in compliance with UL Standard 2703 Section 9.1 Exception, which permits accessible components that are not part of the fault current ground path to not be electrically bonded to the mounting system. The UL Listing covers bonding for a load rating up to 45 psf. For more details on the integrated grounding functionality see the Grounding Specifications section. This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. See the Grounding Specifications for the list of modules tested with the Series 100 system for integrated grounding. Ground Lug has been evaluated to both UL 467 and UL 2703 Listing requirements. Series 100 has been listed with the following Enphase microinverter models for grounding/bonding: M215, M250 and C250. The Enphase microinverters are certified to be mounted to SnapNrack rail with the MLPE Attachment or to the module frame with the Enphase Frame Mount. When installing the Enphase microinverters per the specifications in the MLPE Installation section of this manual, the total roof-mounted PV system is bonded (modules, racking and microinverters) and grounded through the Enphase ground circuit when the Enphase units are properly grounded through to the service entrance. Therefore, no ground lugs or equipment grounding conductor (EGC) are required on the SnapNrack systems. Series 100 has been Listed with the following SolarEdge optimizer models for grounding/bonding: P300 and P350. The SolarEdge optimizers are certified to be mounted to SnapNrack rail with the MLPE Attachment or to the module frame with the SolarEdge Power Optimizer Frame-Mounted Module Add-On. When installing the SolarEdge optimizers per the specifications in the MLPE Installation section of this manual, the total roof-mounted PV system is bonded to the optimizer backing plate (modules, racking and optimizers) and grounded through the ground lugs installed on the SnapNrack rail. Therefore, it is not necessary to run an EGC to each SolarEdge optimizer. The mounting system Bonding Listing is only valid when installed with a Non-Separately Derived PV system. The PV system is required to have a direct electrical connection to another source, such as connecting to the grid via a grid interactive inverter. SnapNrack recommends that bare copper never come into contact with aluminum. Mechanical Loading The Series 100 system is Listed for mechanical loading for different load ratings depending on the mounting configuration and PV module installed. For more details on the mechanical loading details see the Mechanical Loading Specifications section. SnapNrack engineered systems should only be used with SnapNrack components and hardware. Any application outside of those specified in this Installation Manual and the Structural Engineering Report may void the warranty and structural certification could become invalid. The following components have only been evaluated for mechanical loading: Comp L Foot (92 Deg) with L Foot Base, All Purpose L Foot (90 Deg) with L Foot Base, Universal Tile Hook, Flat Tile Hook, 10in Standoff with 1-Hole Base*, 10in Standoff with 4-Hole Base* *All standoff lengths are approved when installed on these bases. If the module clamps have been engaged and need to be loosened and reengaged, SnapNrack recommends moving the module frame 3mm to engage the bonding pin in a new location if required by the AHJ. The UL Listing covers mechanical load ratings for the various span lengths, module orientations and positive, negative, and side load ratings. These values can be found in the Mechanical Loading Specifications. SnapNrack recommends a periodic re-inspection of the completed installation for loose components, loose fasteners, and any corrosion, such that if found, the affected components are to be immediately replaced. 1

Certification Details Fire The Series 100 system has been evaluated for a Class A System Fire Classification for a Steep-Sloped Roof using Type 1 and Type 2 modules. In order to maintain the System Classification, modules must be mounted in the portrait orientation and clamped to the mounting rails between 0 and 12 inches from the top and bottom edges of the module. The Series 100 System has been evaluated for a Class A System Fire Classification for a Low-Sloped Roof using Type 1 and Type 2 modules. In order to maintain the System Classification, modules are clamped to the mounting rails between 0 and 16.3 inches from the top and bottom edges of the module. Because the system was tested at 5 inches above the test roof fixture Series 100 can be installed without any height restrictions and will maintain the Class A System Fire Classification. See Rail Installation Section for potential module-specific height restrictions due to module temperature. 2

Component Details Structural Components ML ML ML Composition Roof Attachment Roof attachment kit for composition shingle roofs including L foot, base, flashing, and hardware Standoff Roof Attachment Roof attachment kit for all roof types including standoff shaft, base, and hardware Universal Tile Roof Attachment Roof attachment kit for any tile roofs including tile hook, base, and hardware ML ML Flat Tile Roof Attachment Roof attachment kit for flat tile roofs including tile hook and hardware Hanger Bolt Roof Attachment Roof attachment kit for all roof types including hanger bolt clamp and hardware Metal Roof Base Attachment Roof attachment kit for flat metal roofs including metal roof base, L foot, and hardware ML, G/B Corrugated Roof Block Attachment Roof attachment for sinusoidal corrugated metal roofs including roof block, L foot, and hardware Seam Clamp Roof Attachment Roof attachment for standing seam metal roofs including seam clamp, L foot, and hardware 3 Standard Rail Rail for Series 100 roof mount racking system UL Listing Legend: ML Evaluated for Mechanical Loading G/B Evaluated for Grounding/Bonding

Component Details Structural Components ML, G/B ML, G/B ML, G/B Standard Rail Splice Rail splice component including base, insert, and hardware Mid Clamp Top-down module mid clamp including clamp and hardware Adjustable End Clamp Top-down module end clamp including clamp and hardware ML Universal End Clamp Bottom-mount module end clamp including clamp and hardware Wire Management/Grounding Components G/B Trunk Cable Clamp Wire Clamp (Trunk Cable Clamp shown) Wire Clip MLPE Attachment Kit Rail attachment for module level power electronics like microinverters and optimizers 4 UL Listing Legend: ML Evaluated for Mechanical Loading G/B Evaluated for Grounding/Bonding

Component Details Wire Management/Grounding Components G/B G/B SnapNrack Ground Lug Ilsco Lay-In Lug GBL-4DBT Aesthetic Components Array Edge Screen Array edge screen kit including mesh edge screen and clips Standard Rail End Cap Rubber end cap for Standard Rail UL Listing Legend: 5 ML Evaluated for Mechanical Loading G/B Evaluated for Grounding/Bonding

Component Details Hardware Torque Specifications Hardware Description Grounding Electrode Conductor to SnapNrack Ground Lug (6-12 AWG Solid Copper) Torque Specification 16 ft-lbs (192 in-lbs) Ilsco Lay-in Lug GBL-4DBT to Rail 5 ft-lbs (60 in-lbs) Grounding Electrode Conductor to Ilsco Lay-in Lug GBL-4DBT (10-14 AWG Solid Copper) Grounding Electrode Conductor to Ilsco Lay-in Lug GBL-4DBT (8 AWG Stranded Copper) Grounding Electrode Conductor to Ilsco Lay-in Lug GBL-4DBT (4-6 AWG Stranded Copper) Adjustable End Clamp, Mid Clamp, Universal End Clamp, Corrugated Roof Block, Hanger Bolt Clamp, Tilt Mount Clamps, Standoff Clamp, Rail Splice, S Tile Roof Hook to S Tile Roof Hook Base, Flat Tile Hook Adjustable End Clamp to Module, Standoff Clamp, Rail Splice (Black Fasteners) 1.67 ft-lbs (20 in-lbs) 1.04 ft-lbs (25 in-lbs) 1.46 ft-lbs (35 in-lbs) 10-16 ft-lbs (120-192 in-lbs) 8-10 ft-lbs (96-120 in-lbs) Standard Base Seam Clamp, Wide Base Seam Clamp 16.7 ft-lbs (200 in-lbs) SolarEdge Frame Mounted Bracket to Module Frame 7 ft-lbs (84 in-lbs) MLPE Attachment Kit (Rail Mounted Bracket to Rail) 10 ft-lbs (120 in-lbs) Enphase Frame Mounted Bracket to Module Frame 13 ft-lbs (156 in-lbs) 6

Pre-Installation Requirements Site Survey Measure the roof surfaces and develop an accurate drawing, including any obstacles such as chimneys and roof vents. If plans are available, check to make sure that the plans match the final structure. Identify any roof access areas or keep-out areas as required by the local AHJ (i.e. fire lanes). Identify any construction issues that may complicate the process of locating roof framing members from the roof surface. If you find structural problems such as termite damage or cracked roof framing members that may compromise the structure s integrity, consult a structural engineer. 52'-0" 22'-4" 40'-0" Y-AXIS X-AXIS 28'-0" 11'-2" 7

Pre-Installation Requirements Design Guidance 1) Layout the modules in the available roof area. Adjacent modules in the same row are spaced 1/2 apart. Adjustable End Clamps require an additional 1.5 of rail extending past module frame, while Universal End Clamps require no extra rail. When installing multiple rows of modules, a minimum spacing gap of 1/8 should be used between rows. 2) Draw the roof framing member location on the layout to identify where roof attachments can be installed. 3) Determine site conditions for calculating the engineering values, confirm site conditions and code versions comply with local AHJ requirements. 4) Reference site conditions and system specifications in Series 100 Structural Engineering Report to determine maximum attachment spacing and cantilever values. 5) Draw roof attachment locations on layout based on maximum attachment spacing and cantilever values. 6) Confirm design complies with UL 2703 Listing for Mechanical Loading. For more details on the mechanical loading details see the Mechanical Loading Specifications section. 7) To simplify the design process and automatically generate a bill of materials for the mounting system, use the Series 100 Configuration Tool located on the SnapNrack website. Always refer to Approved Module Lists in Installation Manuals to ensure installation complies with UL 2703 Listing. 8) Mark distance from array edge to identifiable roof feature in x and y axes. 9) Insert SnapNrack installation details in to design set specific to the project requirements. 3'-0" 3'-0" 26'-4" 16'-6" 19'-9" 8

Pre-Installation Requirements Design Note: Series 100 allows for multiple mounting configurations. Modules can be mounted in portrait (long side of module perpendicular to ridge) or landscape (long side of module parallel to ridge) orientations. In addition, modules can also be short side-mounted (module clamps on short side) or long side-mounted (module clamps on long side). Long-side mounting is recommended for maximum material efficiency. Most residential structures utilize roof framing members that run in-slope with the roof, so a portrait orientation with long-side mounting is typically the most efficient use of materials. PORTRAIT, LONG-SIDE MOUNTING LANDSCAPE, SHORT-SIDE MOUNTING LANDSCAPE, LONG-SIDE MOUNTING PORTRAIT, SHORT-SIDE MOUNTING Safety Guidance Always wear appropriate OSHA approved safety equipment when at active construction site Appropriate fall protection or prevention gear should be used. Always use extreme caution when near the edge of a roof Use appropriate ladder safety equipment when accessing the roof from ground level Safety equipment should be checked periodically for wear and quality issues Always wear proper eye protection 9

Pre-Installation Requirements System Layout 1) Transfer the array layout to the roof using a roof marking crayon to mark the inside and outside corners of the array. 2) Locate the estimated roof framing member positions and mark them in the array area with a roof marking crayon. 3) Transfer rail locations using a chalk line. 4) Mark roof attachment locations on the roof, noting that attachments will be located at intersections of rails and roof framing members. Layout rails such that module frames do not overhang mounting rails more than specified by module manufacturer, more than 30% of total module length, or more than required by the Class A Fire Certification (see Certification Details section). Layout Note: Ensure final roof attachment locations do not exceed the maximum attachment spacing and cantilever specified in the design. Y-AXIS X-AXIS 10

L Foot Mounts Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket Materials Included - L Foot Flashing Kit (1) SnapNrack L Foot Base (1) SnapNrack L Foot Flashing (1) SnapNrack Composition L Foot (1) 5/16-18 SS Flange Hex Nut (1) 5/16-18 X 1-1/4 SS Flange Bolt (1) SnapNrack Channel Nut Other Materials Required (1) 5/16 Lag Screw (1) 5/16 Washer Dimensioned L Foot Dimensioned L Foot Assembly Application Note: Install on composition shingle roofs. 11

L Foot Mounts INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, drill a pilot hole through the roofing material into the roof framing member. Ensure the lag screws will be installed in a solid portion of the roof framing member. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 2) Apply roofing sealant to the bottom of the base and directly onto the lag screw to ensure a water tight seal. 3) Attach the L Foot Base with a 5/16 lag screw, drive lag screw for minimum 2.5 embedment into the roof framing member. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench to prevent L Foot Base from rotating. 4) Pry up shingles with a breaker bar and install flashing underneath shingle course above installed base, position flashing so base stud extends through hole in bottom edge of flashing. Ensure flashing extends minimum (2) courses above base, and does not overhang bottom edge of shingle course. 5) Place the L Foot on the base stud over the flashing and tighten the flange nut over the L Foot, torque to 10 16 ft-lbs. The L Foot can be attached in any orientation. 6) If necessary, adjust the vertical face of the L Foot with the live hinge feature and adjust angle of L Foot so that the vertical face is perpendicular to the roof surface. Apply a horseshoe of sealant under flashing to direct water away from penetration. 12

Standoff Mounts Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket Materials Included - Standoff Kit (1) SnapNrack Standoff Base, 1-Hole (1) SnapNrack Standoff Shaft (1) SnapNrack Rubber Rain Collar (1) SnapNrack Standoff Clamp (1) 5/16 SS Split Lock Washer (1) 5/16-18 X 2 SS HCS Bolt (1) SnapNrack Channel Nut Other Materials Required (1) 5/16 Lag Screw (1) 5/16 Washer Conical Flashing (Not Shown) Dimensioned Standoff Shaft Dimensioned Standoff Assembly Application Note: Install on concrete or clay tile roofs. 13

Standoff Mounts INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, remove roof tile where the roof attachment will be installed and drill a pilot hole through the roofing material into the roof framing member. Ensure the lag screws will be installed in a solid portion of the roof framing member. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 2) Apply roofing sealant and attach the base with a 5/16 lag screw, drive lag screw for minimum 2.5 embedment into the roof framing member. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench to prevent 1-Hole Base from rotating. 3) Set the flashing by sliding the flashing underneath the row of tiles directly above the installed base, with the hole in the flashing directly above the base stud. 4) Attach the standoff shaft by sliding it through the hole in the flashing and tighten it onto the base stud with channel locks. As an alternative, the post may be installed prior to the flashing if there is adequate clearance for the flashing to be slid over the post and under the tile simultaneously. 5) Cut the tile to fit around the flashing, replace the tile, then attach the standoff clamp by first sliding the rubber rain collar over the standoff shaft then the standoff clamp with bolt, washer and channel nut. 14

Standoff Mount Options Materials Included Standoff Kit (Steel Structural Member) (1) SnapNrack Standoff Base, 1-Hole (1) SnapNrack Standoff Shaft (1) SnapNrack Rubber Rain Collar (1) SnapNrack Standoff Clamp (1) 5/16 SS Split Lock Washer (1) 5/16-18 X 2 SS HCS Bolt (1) SnapNrack Channel Nut Other Materials Required Standoff Base, 1-Hole (1) 1/4 Self-drilling Screw (1) Conical Flashing Application Note: Install on roofs with steel structural member configurations. 15

Standoff Mount Options Materials Included 4-Hole Standoff Kit (1) SnapNrack Standoff Base, 4-Hole (1) SnapNrack Standoff Shaft (1) SnapNrack Rubber Rain Collar (1) SnapNrack Standoff Clamp (1) 5/16 SS Split Lock Washer (1) 5/16-18 X 2 SS HCS Bolt (1) SnapNrack Channel Nut Other Materials Required Standoff Base, 4-Hole (2-4) 1/4 Wood Screws (1) Conical Flashing Application Note: Install on roofs with composite wood I-joists, unless fastening to top flange is prohibited by I-joist manufacturer. 16

Standoff Mount Options Materials Included HD Standoff Kit (1) SnapNrack HD Standoff Base, 6-Hole (1) SnapNrack HD Standoff Shaft (1) SnapNrack Rubber Rain Collar (1) SnapNrack Standoff Clamp (1) 5/16 SS Split Lock Washer (1) 5/16-18 X 2 SS HCS Bolt (1) SnapNrack Channel Nut Other Materials Required HD Standoff Base, 6-Hole (2) 5/16 Lag Screw (minimum) (1) Conical Flashing Application Note: 17 Install on foam or other built-up roofs.

Standoff Mount Options INSTALLATION INSTRUCTIONS Steel Structural Member Installation 1) Follow the instruction exactly as the SnapNrack Standoff Mounts, substituting the 1/4 self-drilling screw for the 5/16 lag screw. 4-Hole Base Installation 1) Follow the instruction exactly as the SnapNrack Standoff Mounts, substituting the 1-Hole Base for the 4-Hole Base and 1/4 wood screws (with 1.25 minimum embedment) for the 5/16 lag screw. HD Base Installation 1) Remove the foam roofing above the roof framing member to be installed on. 2) Attach the base with (2) 5/16 lag screws minimum in center holes, or (4) 5/16 lag screws in corner holes. Drive lag screws for minimum 2.5 embedment into the roof framing member. 3) Attach the standoff shaft by tightening it onto the base with channel locks. 4) Replace the foam roofing or roofing membrane that was removed. 5) Set the flashing by sliding the cone flashing over the exposed standoff and heat weld the rubber membrane around the flashing for a water tight seal. 6) Attach the standoff clamp by first sliding the rubber rain collar over the standoff shaft then the standoff clamp with bolt, washer and channel nut. 18

Universal Tile Hook Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket Flat Pry Bar Materials Included - Universal Tile Hook (1) SnapNrack Universal Tile Hook Base (1) SnapNrack Universal Tile Hook Arm (2) 5/16-18 X 1-1/4 SS Flange Bolt (2) SnapNrack Channel Nut Other Materials Required (Not Shown) (2) 5/16 Lag Screw (2) 5/16 Washer Flexible Flashing (when required for deck-level flashing) Note: Tile Roof Hooks are limited to areas with design wind speeds of 120 mph or less. Roof attachment spacing with Tile Roof Hooks is limited to 6 ft (maximum). 7.25 8.80 8.00 Dimensioned Universal Tile Hook Assembly Application Note: Install on flat, W and S style concrete tile roofs. 19

Universal Tile Hook INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, remove roof tile where the roof attachment will be installed and drill two pilot holes through the roofing material into the roof framing member. Align the base over the roof framing member so the hook can enter at the valley of a tile and not extend beyond the edge of the base. 2) Apply roofing sealant and attach the base with (2) 5/16 lag screws, drive lag screws for minimum 2.5 embedment into the roof framing member. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench. 3) Insert the top end of the arm into the groove at the top of the base and slide the arm to position it over the valley of the tile below, then lower the arm down. Ensure the lag screws will be installed in a solid portion of the roof framing member. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 4) Work the channel nut into the lower groove of the base as you lower the arm, without removing the channel nut. 5) Once hook arm position is set, tighten the bolt in the channel nut and ensure the arm fully seats to the base. 6) If deck-level flashing is required, integrate roof felt or a flexible flashing with the existing underlayment and over the Tile Hook. 20 7) Replace the roof tiles and install SnapNrack Standard Rail directly to the available channel nut on the hook arm.

Universal Tile Hook Optional Deck-Level Flashing INSTALLATION INSTRUCTIONS 1) Prepare the underlayment surface for adhesion. Best Practice: The surface should be dry, clean and free of any dirt, dust or foreign matter that may prevent adhesion. Clean the surface around the Tile Hook with a brush of medium-stiff bristles. If necessary, prime the surface with compatible spray or paint primer. 2) Peel off the backings from two 4 x8 strips of flexible flashing. 3) Apply the strips along the side edges of the synthetic underlayment flashing with 2 laps at the top and side edges. 4) Apply the synthetic underlayment flashing centered over the tile hook and abutted to the lower row of tile. Removal of an additional tile may be necessary. 5) Press and smooth out any creases or air bubbles with a roller to maximize contact of the adhesive to 100% of the flashing and decklevel surface. 6) Peel off the backing from a 4 x19 strip of flexible flashing. 7) Apply the strip along the top edge of the flashing with 2 laps at the top and side edges, then roll out any creases or air bubbles between the strip, the flashing, and the decklevel surface. 21 8) Peel off the backing and apply the second 4 x19 strip of flexible flashing along the top edge of the first strip with a 2 lap at the top edge, then roll out any creases between the strip and the decklevel surface.

Universal Tile Hook Optional Deck-Level Flashing INSTALLATION INSTRUCTIONS SnapNrack recommends testing underlayment surfaces for adhesion. If adhesion is found to be marginal, then an adhesive primer is recommended to ensure optimal adhesion. See instructions below: 1) Ensure surface is dry, clean, and free of anything that may prevent adhesion 2) Shake can of adhesive before use 3) Apply a uniform coat of adhesive to surface being treated 4) Allow surface to dry for 2 minutes (no more than 10 minutes) before applying flashing 5) Never cover wet adhesive SnapNrack recommends using Protecto Wrap Protecto Seal 45 waterproofing membrane, or equivalent, as the flexible flashing and lap material. 22

Flat Tile Hook Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket Flat Pry Bar Materials Included - Universal Tile Hook (1) SnapNrack Flat Tile Hook (1) 5/16-18 X 1-1/4 SS Flange Bolt (1) SnapNrack Channel Nut Other Materials Required (Not Shown) (2) 5/16 Lag Screw (2) 5/16 Washer Flexible Flashing (when required for deck-level flashing) Note: Tile Roof Hooks are limited to areas with design wind speeds of 120 mph or less. 8.78 Roof attachment spacing with Tile Roof Hooks is limited to 6 ft (maximum). 6.19 1.25 Dimensioned Flat Tile Hook Assembly Application Note: Install on flat concrete tile roofs. 23

Flat Tile Hook INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, remove roof tile where the roof attachment will be installed and drill two pilot holes through the roofing material into the roof framing member. Ensure the lag screws will be installed in a solid portion of the roof framing member. 2) Apply roofing sealant and attach the base with (2) 5/16 lag screws, drive lag screws for minimum 2.5 embedment into the roof framing member. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench. 3) If deck-level flashing is required, integrate roof felt or a flexible flashing with the existing underlayment and over the Tile Hook. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 4) Replace the roof tiles and install SnapNrack Standard Rail directly to the available channel nut on the hook arm. 24

Flat Tile Hook Optional Deck-Level Flashing INSTALLATION INSTRUCTIONS 1) Prepare the underlayment surface for adhesion. Best Practice: The surface should be dry, clean and free of any dirt, dust or foreign matter that may prevent adhesion. Clean the surface around the Tile Hook with a brush of medium-stiff bristles. If necessary, prime the surface with compatible spray or paint primer. 2) Peel off the backing from a 9 square of flexible flashing. 3) Apply flexible flashing centered laterally over tile hook and abutted to the tile hook arm. Ensure tape adheres to the corners between the edges of the Tile Hook and the underlayment as well as over the lag screw heads and tile hook surface. 4) Press and smooth out any creases or air bubbles with a roller to maximize contact of the flashing adhesive to 100% of the surface and Tile Hook. 5) Peel off the backing from a 4 by 13 strip of flexible flashing. 6) Apply the strip with 2 laps at the top and side edges of the square flashing. Roll out any creases or air bubbles between the strip, the flashing and the underlayment surface. SnapNrack recommends testing underlayment surfaces for adhesion. If adhesion is found to be marginal, then a primer is recommended to ensure optimal adhesion. See instructions below: 1) Ensure surface is dry, clean, and free of anything that may prevent adhesion 2) Shake can of adhesive before use 3) Apply a uniform coat of adhesive to surface being treated 4) Allow surface to dry for 2 minutes (no more than 10 minutes) before applying flashing 5) Never cover wet adhesive SnapNrack recommends using Protecto Wrap Protecto Seal 45 waterproofing membrane, or equivalent, as the flexible flashing and lap material. 25

Hanger Bolt Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Threaded Bit Adapter Torque Wrench Socket Wrench 1/2 Socket Materials Included - Hanger Bolt Kit (2) SnapNrack Hanger Bolt Clamp (1) 5/16 SS Split Lock Washer (1) 5/16-18 X 1-1/2 SS HCS Bolt (1) SnapNrack Channel Nut Other Materials Required (1) 3/8 Stainless Steel Hanger Bolt Dimensioned Hanger Bolt Clamp Dimensioned Hanger Bolt Clamp Assembly Application Note: Install on roofs where practical flashing solutions are not available, such as sinusoidal style corrugated roofs. 26 Grounding and bonding of mounting system to metal roof panels shall meet local AHJ requirements.

Hanger Bolt INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, drill a pilot hole through the roofing material into the roof framing member. Ensure the lag screws will be installed in a solid portion of the roof framing member. 2) Apply roofing sealant directly onto the pilot hole and the hanger bolt to ensure a water tight seal. 3) Attach the hanger bolt using the threaded bit adapter, drive hanger bolt for minimum 2.5 embedment of lag shank into the roof framing member. Best Practice: If using an impact driver, finish tightening hanger bolt with a hand wrench. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 4) Attach the channel nut of the hanger bolt assembly into side channel of rail. 5) Attach the hanger bolt clamp by setting it around the threaded portion of the hanger bolt to the desired height and tighten to 10-16 ft-lbs. 27

Metal Roof Base Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Torque Wrench Socket Wrench 1/2 Socket Materials Included - Metal Roof Base (1) SnapNrack Metal Roof Base (1) SnapNrack All Purpose L Foot (1) 5/16-18 SS Flange Nut (1) 5/16-18 X 1-1/4 SS Flange Bolt (1) SnapNrack Channel Nut Other Materials Required (1) 5/16 Lag Screw or 1/4 Self-drilling Screw (Not Shown) Dimensioned Metal Roof Base Assembly Application Note: Install on metal roof profiles with flat surface large enough to accommodate 1-5/8 wide base. 28 Grounding and bonding of mounting system to metal roof panels shall meet local AHJ requirements.

Metal Roof Base INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, drill a pilot hole through the roofing material into the roof framing member. Ensure the lag or self-drilling screws will be installed in a solid portion of the roof framing member. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 2) Attach the base with 5/16 lag screw (or 1/4 self-drilling screw), drive lag screw for minimum 2.5 embedment into the roof framing member. Ensure area is free from metal shavings and debris before installing Metal Roof Base. Metal roofs with excessive debris, corrosion, or nonfactory coating should be evaluated for adequate sealing surface. Additional roof sealant not required but can be applied after tightening the Metal Roof Base to roof, if desired. 3) Thread Metal Roof Base cap onto Metal Roof Base bottom, ensuring cap is fully seated to base. Take care to ensure the base does not twist when cap is tightened. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench. SNAPNRACK STANDARD RAIL 4) Attach L Foot to stud in Metal Roof Base cap. Best Practice: Finish tightening hardware with a hand wrench to prevent L Foot from rotating. 5/16-18 STAINLESS FLANGE NUT TORQUE 10-16 FT-LBS SNAPNRACK L-FOOT SNAPNRACK METAL ROOF BASE CAP 1/4-20 TEK OR EQUIVALENT SELF DRILLING FASTENER. TORQUE TO MANUFACTURER SPECIFICATIONS S, TYPICAL SNAPNRACK METAL ROOF BASE BOTTOM 29 METAL ROOF DECK

Corrugated Straddle Block Required Tools Hammer or Stud Finder Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket Materials Included - Corrugated Straddle Block (1) SnapNrack Corrugated Straddle Block (1) SnapNrack All Purpose L Foot (1) 5/16-18 X 1-1/4 SS Flange Bolt (1) SnapNrack Channel Nut Other Materials Required (1) 5/16 Lag Screw or 1/4 Self-drilling Screw (1) Washer Note: Self-drilling screw for steel roofing members, lag screw for wooden roof framing members. Dimensioned Corrugated Straddle Block Dimensioned Corrugated Straddle Block Assembly Application Note: Install on sinusoidal style corrugated metal roofs. 30 Grounding and bonding of mounting system to metal roof panels shall meet local AHJ requirements.

Corrugated Straddle Block INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, drill a pilot hole through the roofing material into the roof framing member. Ensure the lag or self-drilling screws will be installed in a solid portion of the roof framing member. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant. 2) Apply roofing sealant directly onto the pilot hole and the lag to ensure a water tight seal. 3) Attach the Straddle Block and L Foot with 5/16 lag screw, drive lag screw for minimum 2.5 embedment into the roof framing member. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench to prevent L Foot from rotating. 4) Install SnapNrack standard rail directly onto channel nut and tighten L Foot assembly silver hardware to 10-16 ft-lb. 31

Tilt Mount Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket Materials Included - 5-15 Tilt Kit (2) SnapNrack Standoff Base, 1-Hole (2) SnapNrack Standoff Shaft (2) SnapNrack Standoff Clamp (2) 5/16 SS Split Lock Washer (2) 5/16-18 X 2 SS HCS Bolt (2) 5/16-18 SS Flange Nut (2) 5/16-18 X 1-1/4 SS Flange Bolt (2) SnapNrack All Purpose L Foot (2) SnapNrack Channel Nut (2) SnapNrack Rubber Rain Collar Other Materials Required (Not Shown) (2) 5/16 Lag Screw (2) Washer (2) Conical Flashings Dimensioned Standoff Clamp Dimensioned Standoff Assembly Application Note: Install when additional tilt of solar array is required. 32

Tilt Mount Required Tools Hammer or Stud Finder Roof Marking Crayon Drill with 3/16 Pilot Drill Bit Roof Sealant Torque Wrench Socket Wrench 1/2 Socket SnapNrack High Tilt Tool Materials Included - 10-45 Tilt Kit (2) SnapNrack Standoff Base (2) SnapNrack Standoff Shaft (2) SnapNrack Standoff Clamp (2) 5/16 SS Split Lock Washer (3) 5/16-18 X 1-1/4 SS Flange Bolt (1) 5/16-18 SS Flange Nut (2) 5/16-18 X 2 SS HCS Bolt Other Materials Required (2) SnapNrack All Purpose L Foot (4) SnapNrack Channel Nut (2) Rubber Rain Collar (1) Cut-to-Length Standard Rail (Rear Tilt Leg) (2) 5/16 Lag Screw (Not Shown) (2) 5/16 Washer (Not Shown) (2) Roof Cone Flashings (Not Shown) Dimensioned Standoff Clamp Application Note: Install when additional tilt of solar array is required. Dimensioned Standoff Assembly 33

Tilt Mount INSTALLATION INSTRUCTIONS 1) Using roof attachment locations drawn during system layout, drill a pilot hole through the roofing material into the roof framing member. Ensure the lag or self-drilling screws will be installed in a solid portion of the roof framing member. If the roof framing member is not found then seal the pilot hole immediately with roofing sealant 2) Apply roofing sealant directly onto the pilot hole and the lag to ensure a water tight seal. 3) Attach the base with a 5/16 lag screw, drive lag screw for minimum 2.5 embedment into the roof framing member. Best Practice: If using an impact driver, finish tightening lag screw with a hand wrench to prevent 1-Hole Base from rotating. 4) Attach the standoff shaft and tighten it onto the base stud with channel locks. Set the flashing by sliding it over the standoff and directly applying it to the roof surface, using all necessary sealants and attachment methods for flashing. Slide Rubber Rain Collar over the standoff shaft to cover top of flashing. 5) Slide the standoff clamp and L Foot onto the standoff shaft, adjust it to the desired height, and tighten hardware to 10-16 ft-lbs. 34

Tilt Mount INSTALLATION INSTRUCTIONS 6) For tilts greater than 15 degrees, cut length of rail to use as rear tilt leg and attach to rear standoff using L Feet hardware. 7) Set array tilt and tighten hardware to 10-16 ft-lbs. Best Practice: High Tilt Tool may be constructed to help set array tilt and support the top rail while installing first modules (see below). HIGH TILT TOOL INSTRUCTIONS 1) Construct High Tilt Tool using a length of SnapNrack rail cut to the dimensions of the module(s) being installed, two 4 lengths of Rail Cover with 3/8 holes drilled in the center of each, two channel nuts, and two 5/16 bolts. 2) Assemble bolts and channel nuts in rail covers through the pre-drilled holes with channel nut on flat side of rail cover, then slide or snap channel nuts into top channel of rail. 3) Adjust the rail covers to the correct positions, spaced at the same distance as that between the lower rail and top rail of tilted array. 4) Tighten hardware. Assembled High Tilt Tool 35

Seam Clamp Required Tools Torque Wrench Socket Wrench 1/2 Socket Materials Included - Standard Base Seam Clamp Kit (1) 5/16-18 X 1-1/2 SS HCS Bolt (Black) (1) 5/16 SS Split Lock Washer (1) SnapNrack Seam Clamp Insert (1) SnapNrack Seam Clamp Cam (1) SnapNrack Seam Clamp Standard Base (1) SnapNrack All Purpose L Foot (1) 5/16-18 X 1-1/4 SS Flange Bolt (Not Shown) (1) SnapNrack Channel Nut (Not Shown) Dimensioned Standard Base Seam Clamp Dimensioned Standard Base Seam Clamp Assembly Application Note: Install on standing metal seam roofs. 36 Grounding and bonding of mounting system to metal roof panels shall meet local AHJ requirements.

Seam Clamp Required Tools Torque Wrench Socket Wrench 1/2 Socket Materials Included - Wide Base Seam Clamp Kit (1) 5/16-18 X 1-1/2 SS HCS Bolt (Black) (1) 5/16 SS Split Lock Washer (1) SnapNrack Seam Clamp Insert (1) SnapNrack Seam Clamp Cam (1) SnapNrack Seam Clamp Wide Base (1) SnapNrack All Purpose L Foot (1) 5/16-18 X 1-1/4 SS Flange Bolt (Not Shown) (1) SnapNrack Channel Nut (Not Shown) Dimensioned Wide Base Seam Clamp Dimensioned Wide Base Seam Clamp Assembly Application Note: Install on standing metal seam roofs. 37 Grounding and bonding of mounting system to metal roof panels shall meet local AHJ requirements.

Seam Clamp INSTALLATION INSTRUCTIONS 1) Loosen seam clamp hardware and use roof attachment locations to lay out seam clamps on roof. 2) Attach the seam clamp to the standing metal seam by opening the seam clamp cam and placing the clamp over the top of the standing metal seam. 3) Torque black seam clamp bolt to 200 in-lbs (16.7 ft-lbs). Seam clamps should never be installed using an impact driver. SnapNrack Seam Clamps have been designed to work with a variety of standing seam metal roofs, the most common seam types are: Snap Lock Single Lock Double Lock Design Note: If a specific roof seam is not found on list, contact SnapNrack prior to installation. 38

Installing and Leveling Rails Required Tools Level String Line or Spare Rail Pitch Meter 5/32 Allen Key Torque Wrench Socket Wrench 1/2 Socket Materials Included - Install and Level Rails SnapNrack Standard Rail SnapNrack Standard Rail Splice SnapNrack 1 Standoff Spacer with Set Screw Install on standing metal seam roofs that Pre-Installed the seam clamp SnapNrack fits over. Roof Attachments (L Foot, Standoff, etc.) Standard Rail Profile Rail Splice Profile 39

Installing and Leveling Rails INSTALLATION INSTRUCTIONS 1) Set rails into the attachments by snapping channel nuts into the side channel of the rail. Connect multiple lengths of rail end to end using the SnapNrack rail splice. 2) Level the bottom rail of the array to the roof and tighten attachment points, silver hardware to 10-16 ft-lbs and black hardware to 8-10 ft-lbs. Best Practice: Set attachments in the middle of available leveling range to start. 3) Run a string line or spare rail from the bottom rail to the top rail and set desired pitch of the array by adjusting the top rail, add leveling spacers if needed. 4) Level the top rail by moving the string line down the length of the rail, matching pitch over the entire length of the array. 5) Level the remaining rails to the string line by working out from the middle rail, add leveling spacers if needed. 6) Tighten all racking hardware, silver hardware to 10-16 ft-lbs and black hardware to 8-10 ft-lbs. Note: The minimum standoff height between the modules and roof is as follows: REC Solar, Yingli, and Suniva modules: 4.00 ReneSola modules: 3.93 (100 mm) Trina Solar modules: 4.53 (115 mm) 40

Leveling with Spacers INSTALLATION INSTRUCTIONS Use a single level spacer on no more than 30% of attachment points. Use a double level spacer on no more than 10% of attachment points. L Foot *Up To 3 Leveling Standoff *Up To 3 Leveling 41

SnapNrack Rail Splice INSTALLATION INSTRUCTIONS 1) Align sections of rail so that ends butt up to each other. Leave approximately 1/8 gap between rails to allow for thermal expansion of rail. 2) Set rail splice assembly in to the side channel of rail, making sure the base is seated all the way into the channel and that the splice is centered. Best Practice: Loosening splice bolts will allow for play with the insert and ease installation. 3) Lift up on splice insert to engage the upper lip of rail channel and tighten bolts by hand to secure insert in rails. Best Practice: Push up on bolts or use fingers on both sides of insert to ensure proper engagement. 4) Use a socket wrench to tighten splice bolts, torque silver hardware to 10 16 ft-lbs and black hardware to 8 10 ft-lbs. 42

Module Installation Required Tools Torque Wrench Socket Wrench 1/2 Socket Materials Included - Install Module Clamps Pre-Installed SnapNrack Roof Attachments Pre-Installed SnapNrack Rails SnapNrack Mid Clamp Assemblies Install on standing metal seam roofs that SnapNrack the seam End clamp Clamp fits over. Assemblies PV Modules Mid Clamp Assembly Adjustable End Clamp Assembly (1) 5/16-18 SS HCS Bolt (1) 5/16 SS Split Lock Washer (1) SnapNrack Bonding Mid Clamp Install on standing metal seam roofs that (1) the 5/16-18 seam clamp SnapNrack fits over. Channel Nut (1) 5/16-18 SS HCS Bolt (1) 5/16 SS Split Lock Washer (1) SnapNrack Self Adjusting Top (1) SnapNrack Self Adjusting Bottom Universal End Clamp Assembly (1) 5/16-18 X 1-1/2 SS HCS Bolt (1) 5/16 X 3/4 SS Flat Washer (1) SnapNrack Universal Wedge (1) SnapNrack Universal Wave 43

Module Installation INSTALLATION INSTRUCTIONS SnapNrack Mid Clamp 1) Snap the channel nut into the top channel of the rail. 2) Slide the clamp flush to the module with the top lip of the mid clamp over the top edge of the module frame. Take care to avoid having wires pinched between modules and rails, as this can lead to system failure and be dangerous. 3) Place the next module flush to the other side of the mid clamp. Mid clamps create 1/2 gap between modules. 4) Tighten hardware, torque silver hardware to 10-16 ft-lbs and black hardware to 8-10 ft-lbs. 44

Module Installation INSTALLATION INSTRUCTIONS SnapNrack Adjustable End Clamp 1) Snap the channel nut into the top channel of the rail. Adjustable End Clamps require 1.5 of extra rail to extend past the end of the module frame. 2) Slide the clamp flush to the module with the top lip of the end clamp over the top edge of the module frame. Take care to avoid having wires pinched between modules and rails, as this can lead to system failure and be dangerous. 3) Tighten hardware, torque silver hardware to 10-16 ft-lbs and black hardware to 8-10 ft-lbs. 4) Install rubber end cap to finish. 45

Module Installation INSTALLATION INSTRUCTIONS SnapNrack Universal End Clamp 1) Slide the preassembled Universal End Clamp (UEC) into the end of the rail. 2) Lift the module and slide the clamp far enough under the module to pass the lip of the bottom edge of the module frame. Take care to avoid having wires pinched between modules and rails, as this can lead to system failure and be dangerous. 3) Use the pull tab to hold the UEC taut towards the end of the rail and tighten hardware to 10 16 ft-lbs. UEC hardware must be tightened to 12 ft-lbs when installed with the following Hanwha modules: Q.BASE-GY XXX Q.PRO-GY XXX Q.PLUS-GY XXX Q.PRO BFR-GY XXX Q.PRO BLK-GY XXX Q.PRO-GY/SC XXX Rail can be flush to the module using the UEC Rail Cutting Tool. 4) Install rubber end cap to finish. Modules need to be grounded separately when Universal End Clamps are the only type of clamp attaching a module. 46

Rail Finishing Required Tools Reciprocating Saw or Portable Band Saw Materials Included - Rail Cutting Tool and Rail End Cap (1) SnapNrack Rail Cutting Tool (1) SnapNrack Rail End Cap Dimensioned Rail Cutting Tool Dimensioned Rail End Cap Application Note: Install on standing metal seam roofs that the seam clamp fits over. Use to cut rail flush to module frame when using Universal End Clamps (UEC). 47

Rail Finishing INSTALLATION INSTRUCTIONS 1) Slide the Rail Cutting Tool over the end of the rail and place it so that the upper lip is safely covering the edge of the module. 2) Use the reciprocating saw or band saw to cut off the end of the rail. 3) Remove the Cutting Tool from the rail. 4) Insert SnapNrack Rail End Cap into the cut end of the rail to create a flush finish to the array. Edge of array with end caps in rails 48

Array Edge Screen Required Tools Wire Cutters Pliers Note: Series 100 Edge Screen is NOT UL Listed. Materials Included - Array Edge Screen (1) SnapNrack Array Edge Screen Clip (1) SnapNrack Array Edge Screen Application Note: Install on standing metal seam roofs that the seam clamp fits over. Install to prevent animals from getting under the array and causing problems such as chewing on wires, or prevent leaves and other debris from collecting. Dimensioned Array Edge Screen Assembly Dimensioned Array Edge Screen Clip (8 Clip Shown) 49

Array Edge Screen INSTALLATION INSTRUCTIONS 1) Measure required height of Array Edge Screen to determine which notch the clip will need to be broken off at. Screen designed to extend below bottom edge of clip. 2) Use pliers to break the Array Edge Screen Clip at the appropriate length. 3) Clip the Array Edge Screen Clip to the lip on the underside of the modules around the area that the edge screen will be installed. Recommended spacing of clips is 3-0 on center and within 6 from the corners of the array. 4) Slide the Array Edge Screen into the hooks on the Edge Screen Clips and repeat for all locations around the array. If necessary, trim Array Edge Screen to desired height using wire cutters. Note: Add-A-Lip Box Frame Adapters are available from SnapNrack for modules with frames that do not have a lip on the underside to receive clip. 50

Wire Management Required Tools Reciprocating Saw or Chop Saw Materials Included - Rail Cover (1) SnapNrack 48 Rail Cover Application Note: Install on standing metal seam roofs that the seam clamp fits over. Install to protect any conductors that are exposed to sunlight that are not approved for use in UV light. Dimensioned 48 Rail Cover Materials Included - Wire Retention Clip SnapNrack Wire Retention Clip Dimensioned Wire Retention Clip Application Note: Install on standing metal seam roofs that the seam clamp fits over. Install as necessary to manage and safely retain conductors within SnapNrack rails. WIRE DIAMETER RANGE (OD):.21" TO.30" Materials Included - Wire Clamp (1) SnapNrack 4-Wire Clamp or Trunk Cable Clamp.80 MAX Application Note: Install on standing metal seam roofs that the seam clamp fits over. Install as necessary to secure cables and conductors running from rail to rail, or transitioning out/in from a rail channel 51 1.75 Dimensioned 4-Wire Clamp Assembly

Wire Management INSTALLATION INSTRUCTIONS SnapNrack 48 Rail Cover 1) Measure the length of the SnapNrack 48 Rail Cover that is needed. 2) Cut the rail cover to length. 3) Place all electrical conductors in the bottom of the rail channel. 4) Snap Rail Cover into place, enclosing all conductors inside of rail channel. SnapNrack Rail Cover is designed to stay in place once installed, use a flat blade screw driver if it needs to be relocated or removed. 52

Wire Management INSTALLATION INSTRUCTIONS SnapNrack Wire Retention Clip 1) Place all electrical conductors in the bottom of the rail channel. 2) Install the Wire Retention Clip by snapping it into place on the rail. SnapNrack 4-Wire or Trunk Cable Clamp 1) Snap Clamp into top or side rail channel. 2) With Wire Clamp loose, place conductors or cables in slots. 3) Tighten Wire Clamp with 1/2 socket, ensure cables and conductors are aligned in the clamp slots. Clamps can be rotated and oriented in any direction. 4) 4-Wire Clamp intended for PV Wire conductors, Trunk Cable Clamp intended for trunk cable. 53

MLPE Installation Required Tools Torque Wrench Socket Wrench 1/2 Socket Materials Included - MLPE Rail Attachment Kit (1) 5/16 X 1-1/2 X 0.125 SS Fender Washer (1) SnapNrack Channel Nut (1) 5/16-18 X 1-1/4 SS Flange Bolt Other Install on standing Materials metal seam Required roofs that the seam clamp fits over. (1) MLPE Unit BOLT-TO-PLATE BONDING 5/16"-18 SS FLANGE BOLT (TORQUE TO 16 FT-LBS) MOUNTING PLATE MIN 1/8" THICK SS FENDER WASHER CHANNEL NUT RAIL SS BONDING PIN Install on standing metal seam roofs Materials Needed that the seam clamp fits over. Enphase Frame Mount Materials Needed SolarEdge Frame Mount Install on standing metal seam roofs that the seam clamp fits over. (1) Enphase Microinverter (1) Enphase Frame Mount (1) SolarEdge Optimizer w/ Frame-Mounted Module Add-On 54

MLPE Installation INSTALLATION INSTRUCTIONS - MLPE RAIL ATTACHMENT 1) Snap the SnapNrack MLPE Rail Attachment Kit channel nut into the desired location on the rail where the microinverter will be installed. 2) Install the microinverter mounting plate onto the bolt of the MLPE Rail Attachment Kit, ensuring that the large fender washer is between the rail and mounting plate. Bolt and washers may need to be removed and then replaced. 3) Tighten hardware, torque silver hardware to 10 ft-lbs. INSTALLATION INSTRUCTIONS - SOLAREDGE FRAME MOUNT 1) Locate the SolarEdge optimizer with Frame-Mounted Module Add- On at a location on the module frame that will not interfere with the SnapNrack rail. 2) Install the optimizer mounting plate onto the module frame and tighten the hardware to 7 ft-lbs. 3) Connect the module leads to the input connectors on the optimizer. Refer to the SolarEdge optimizer Frame-Mounted Module Add-On installation guide for additional instructions. 55

MLPE Installation INSTALLATION INSTRUCTIONS - ENPHASE FRAME MOUNT 1) Locate the Enphase Frame Mount bracket clamp at a location on the module frame that will not interfere with the SnapNrack rail. 2) Slide the microinverter unit onto the bracket clamp, then move it slightly to the left. The microinverter mounting flange should be on the outside of the module frame. 3) Tighten the hardware to 13 ft-lbs 4) Connect the module leads to the microinverter DC connectors. Refer to the Enphase Frame Mount installation guide for additional instructions. 56

Grounding Specifications System Bonding Methods BONDING MID CLAMP ASSEMBLY SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack Standard Rail Splice SS BONDING PIN MODULE FRAME RAIL SS BONDING PIN (4 TOTAL) BONDING SPLICE ASSEMBLY Note: BONDING CHANNEL NUT SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding pins in assembly to properly bond the system (except Universal End Clamps). RAIL Note: SnapNrack rail splices contain an insert with integral bonding pins in assembly to properly bond the system. SnapNrack Ground Lug Assembly 57

Grounding Specifications Ilsco Lay-in Lug Assembly Ground Path Details X M M M X TO EGC X M M M X U M U U U TO EGC U M U U U RAIL RAIL SPLICE MOUNT GROUND LUG M MODULE CLAMP M = MIDCLAMP GROUND PATH EQUIPMENT GROUNDING CONDUCTOR X = X-END CLAMP U = UNIVERSAL END CLAMP 58

Grounding Specifications Ground Path Details - SolarEdge X M M M X TO EGC X M M M X U M U U U TO EGC U M U U U Ground Path Details - Enphase RAIL RAIL SPLICE MOUNT GROUND LUG M MODULE CLAMP M = MIDCLAMP GROUND PATH EQUIPMENT GROUNDING CONDUCTOR SOLAREDGE OPTIMIZER X = X-END CLAMP U = UNIVERSAL END CLAMP X M M M X TO EGC X M M M X U M U U U U M U U U RAIL RAIL SPLICE MOUNT GROUND LUG M MODULE CLAMP M = MIDCLAMP GROUND PATH EQUIPMENT GROUNDING CONDUCTOR ENPHASE MICRO- X = X-END CLAMP U = UNIVERSAL END INVERTER CLAMP 59

Grounding Specifications INSTALLATION INSTRUCTIONS SnapNrack Ground Lug 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug only Listed for use with 6-12 AWG solid copper conductor. 3) Tighten all hardware to a minimum of 16 ft-lbs. 60

Grounding Specifications INSTALLATION INSTRUCTIONS Ilsco Lay-In Lug 1) Drill and deburr a 1/4 hole in the back side of the rail for the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. Torque rail connection to 5 ft-lbs. 2) Place grounding conductor into slot. 3) Tighten set screw per Ilsco s recommendation (see below). Torque set screw to 20 in-lbs for #10-#14 solid and stranded copper, 25 in-lbs for #8 stranded copper, and 35 in-lbs for #4-#6 stranded copper. Note: System has been evaluated to a maximum overcurrent device (OCD) protection level of 20 Amps. Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing. SnapNrack recommends that bare copper never come into contact with aluminum. SnapNrack Ground Lug: torque bolt to 16 ft-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling of a hole in the rail. Hardware connection to rail: 5 ft-lbs. Torque for lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 inlbs, #4-#6 stranded copper- 35 in-lbs. 61