A Study on Gaze Estimation System using Cross-Channels Electrooculogram Signals

Similar documents
Research Article Gaze Estimation Method Using Analysis of Electrooculogram Signals and Kinect Sensor

An EOG based Human Computer Interface System for Online Control. Carlos A. Vinhais, Fábio A. Santos, Joaquim F. Oliveira

1. INTRODUCTION: 2. EOG: system, handicapped people, wheelchair.

Using Eye Blinking for EOG-Based Robot Control

Design of EOG based Human Machine Interface system

Non Invasive Brain Computer Interface for Movement Control

Design and Experiment of Electrooculogram (EOG) System and Its Application to Control Mobile Robot

Performance Improvement of Contactless Distance Sensors using Neural Network

SMART Wheelchair by using EMG & EOG

Motion Control of a Three Active Wheeled Mobile Robot and Collision-Free Human Following Navigation in Outdoor Environment

Motor Imagery based Brain Computer Interface (BCI) using Artificial Neural Network Classifiers

A New Instrumentation Amplifier Architecture Based on Differential Difference Amplifier for Biological Signal Processing

Towards a Google Glass Based Head Control Communication System for People with Disabilities. James Gips, Muhan Zhang, Deirdre Anderson

RESEARCH AND DEVELOPMENT OF DSP-BASED FACE RECOGNITION SYSTEM FOR ROBOTIC REHABILITATION NURSING BEDS

Journal Title ISSN 5. MIS QUARTERLY BRIEFINGS IN BIOINFORMATICS

Quality Improvement Of Image Processing Using Fuzzy Logic System

Automated Detection of Early Lung Cancer and Tuberculosis Based on X- Ray Image Analysis

Voice based Control Signal Generation for Intelligent Patient Vehicle

Vision Defect Identification System (VDIS) using Knowledge Base and Image Processing Framework

Using Electrooculogram and Electromyogram for powered wheelchair

MOUSE CURSOR CONTROL SYTEM BASED ON SSVEP

International Journal of Computer Sciences and Engineering. Research Paper Volume-5, Issue-12 E-ISSN:

FUZZY AND NEURO-FUZZY MODELLING AND CONTROL OF NONLINEAR SYSTEMS

Target Recognition and Tracking based on Data Fusion of Radar and Infrared Image Sensors

Proceedings of the 6th WSEAS International Conference on Applied Computer Science, Tenerife, Canary Islands, Spain, December 16-18,

Research Article A Segmental Approach with SWT Technique for Denoising the EOG Signal

An Enhanced Biometric System for Personal Authentication

Ultra Low Power Multistandard G m -C Filter for Biomedical Applications

BME 3113, Dept. of BME Lecture on Introduction to Biosignal Processing

PROCESSING ECG SIGNAL WITH KAISER WINDOW- BASED FIR DIGITAL FILTERS

Comparison of Adaptive Neuro-Fuzzy based PSS and SSSC Controllers for Enhancing Power System Oscillation Damping

Fingers Bending Motion Controlled Electrical. Wheelchair by Using Flexible Bending Sensors. with Kalman filter Algorithm

Multi-modality EMG and Visual Based Hands-Free Control of an Intelligent Wheelchair

This list supersedes the one published in the November 2002 issue of CR.

Self-learning Assistive Exoskeleton with Sliding Mode Admittance Control

Non-Invasive Brain-Actuated Control of a Mobile Robot

Classification for Motion Game Based on EEG Sensing

Patter Recognition Applied to Mouse Pointer Controlled by Ocular Movements

Controlling a Robotic Arm by Brainwaves and Eye Movement

Eye Tracking Computer Control-A Review

Review on Eye Movement Controlled Wheelchair

Human Authentication from Brain EEG Signals using Machine Learning

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING

Interaction rule learning with a human partner based on an imitation faculty with a simple visuo-motor mapping

DATA ACQUISITION FOR STOCHASTIC LOCALIZATION OF WIRELESS MOBILE CLIENT IN MULTISTORY BUILDING

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

Intelligent Eddy Current Crack Detection System Design Based on Neuro-Fuzzy Logic

Optic Flow Based Skill Learning for A Humanoid to Trap, Approach to, and Pass a Ball

* Notebook is excluded. Features KL-720 contains nine modules, including Electrocardiogram Measurement, E lectromyogram Measurement,

Simulation Analysis of Control System in an Innovative Magnetically-Saturated Controllable Reactor

VEHICLE LICENSE PLATE DETECTION ALGORITHM BASED ON STATISTICAL CHARACTERISTICS IN HSI COLOR MODEL

A Novel Fuzzy Neural Network Based Distance Relaying Scheme

Smart Phone Accelerometer Sensor Based Wireless Robot for Physically Disabled People

ANFIS-PID Controller for Arm Rehabilitation Device

*Notebook is excluded

tsushi Sasaki Fig. Flow diagram of panel structure recognition by specifying peripheral regions of each component in rectangles, and 3 types of detect

Research on Pupil Segmentation and Localization in Micro Operation Hu BinLiang1, a, Chen GuoLiang2, b, Ma Hui2, c

Replacing Fuzzy Systems with Neural Networks

An Electooculogram Based Virtual Instrumentation System

REBO: A LIFE-LIKE UNIVERSAL REMOTE CONTROL

A Finite Impulse Response (FIR) Filtering Technique for Enhancement of Electroencephalographic (EEG) Signal

Vision System for a Robot Guide System

DETECTION AND CLASSIFICATION OF POWER QUALITY DISTURBANCES

3D display is imperfect, the contents stereoscopic video are not compatible, and viewing of the limitations of the environment make people feel

Real Robots Controlled by Brain Signals - A BMI Approach

CONDUCTIVITY sensors are required in many application

Smart Home System for Energy Saving using Genetic- Fuzzy-Neural Networks Approach

Modelling and Simulation of Tactile Sensing System of Fingers for Intelligent Robotic Manipulation Control

Bi-modal human machine interface for controlling an intelligent wheelchair

SELECTIVE NOISE FILTERING OF SPEECH SIGNALS USING AN ADAPTIVE NEURO-FUZZY INFERENCE SYSTEM AS A FREQUENCY PRE-CLASSIFIER

Urban Road Network Extraction from Spaceborne SAR Image

Geometric Neurodynamical Classifiers Applied to Breast Cancer Detection. Tijana T. Ivancevic

Comparison of MLP and RBF neural networks for Prediction of ECG Signals

Physiological signal(bio-signals) Method, Application, Proposal

A Vehicle Detection Algorithm Based on Wireless Magnetic Sensor Networks

Hands-free Operation of a Small Mobile Robot*

A Study on Ocular and Facial Muscle Artifacts in EEG Signals for BCI Applications

Development of Flexible Pneumatic Cylinder with Backdrivability and Its Application

Discrete Wavelet Transform and Support Vector Machines Algorithm for Classification of Fault Types on Transmission Line

Human-Centric Trusted AI for Data-Driven Economy

DEMONSTRATION OF AUTOMATIC WHEELCHAIR CONTROL BY TRACKING EYE MOVEMENT AND USING IR SENSORS

COMPARATIVE STUDY OF PID AND FUZZY CONTROLLER ON EMBEDDED COMPUTER FOR WATER LEVEL CONTROL

Sri Sai Ram Engineering College

Fuzzy-Heuristic Robot Navigation in a Simulated Environment

IDENTIFYING TYPES OF SIMULTANEOUS FAULT IN TRANSMISSION LINE USING DISCRETE WAVELET TRANSFORM AND FUZZY LOGIC ALGORITHM

Path Following and Obstacle Avoidance Fuzzy Controller for Mobile Indoor Robots

AN APPROXIMATION-WEIGHTED DETAIL CONTRAST ENHANCEMENT FILTER FOR LESION DETECTION ON MAMMOGRAMS

I. INTRODUCTION. Keywords Image Contrast Enhancement; Fuzzy logic; Fuzzy Hyperbolic Threshold; Intelligent Techniques.

Training of EEG Signal Intensification for BCI System. Haesung Jeong*, Hyungi Jeong*, Kong Borasy*, Kyu-Sung Kim***, Sangmin Lee**, Jangwoo Kwon*

DC Motor Speed Control: A Case between PID Controller and Fuzzy Logic Controller

A DUAL FUZZY LOGIC CONTROL METHOD FOR DIRECT TORQUE CONTROL OF AN INDUCTION MOTOR

Differentiation of Malignant and Benign Masses on Mammograms Using Radial Local Ternary Pattern

Simulation of Synchronous Machine in Stability Study for Power System: Garri Station as a Case Study

Citation Nagasaki University ( 長崎大学 ), 博士 ( 工学 )

FAULT DETECTION AND DIAGNOSIS OF HIGH SPEED SWITCHING DEVICES IN POWER INVERTER

Classification of EEG Signal using Correlation Coefficient among Channels as Features Extraction Method

Research on 3-D measurement system based on handheld microscope

Design and development of a Virtual Instrument for Bio-signal Acquisition and Processing using LabVIEW

Implementation of Human-Machine Interface via Measurement and Treatment of Bio-Potential

Integrated Digital System for Yarn Surface Quality Evaluation using Computer Vision and Artificial Intelligence

Transcription:

, March 12-14, 2014, Hong Kong A Study on Gaze Estimation System using Cross-Channels Electrooculogram Signals Mingmin Yan, Hiroki Tamura, and Koichi Tanno Abstract The aim of this study is to present electrooculogram signals that can be used as a human computer interface efficiently. Establishing an efficient alternative channel for communication without overt speech and hand movements is important for increasing the quality of life for patients suffering from Amyotrophic Lateral Sclerosis or other illnesses that prevent correct limb and facial muscular responses. In this paper, we introduce gaze estimation system of 24 Angles using cross-channels electrooculogram signals. This system records electrooculogram signals when the patients focused on each direct. All these recorded signals could be analyzed using the fuzzy mathematical model will be set up. From simulation results, the 24 pattern of eyeball movements is recognized under an accuracy of 87% in our system. Index Terms Cross-Channels, Electrooculogram Signal, Gaze estimation, Fuzzy mathematical model E I. INTRODUCTION lectrooculography is a technique for measuring the corneo-retinal standing potential that exists between the front and the back of the human eye. And the resulting signal is called the electrooculogram (abbr. EOG). EOG can be modeled by a dipole [1], and these systems can be used in medical systems. There are several EOG-based Human-Computer Interface studies in literature. A wheelchair controlled with the eye movements is developed for the disabled and elderly people. The eyes movement signals and sensor signals are combined, and both direction and acceleration are controlled [2]. Because the EOG signals are slightly different for the each subject, a dynamical threshold algorithm is developed [3]. In order to classify the difference of each eye movements, an initial threshold is set due to the individual difference, and the initial threshold is distributed in a dynamic range. Threshold value needs to be renewed for adjusting irregular changes. According to this threshold, the output signal is converting into the binary systems, and actual functionality could be realized by applications designed for each uses. The EOG, the Electroencephalogram (abbr. EEG) and the Electromyogram (abbr. EMG) signals are classified in real time, and movable robots are controlled by using an artificial neural network classifier [4], [5]. However, In-depth studies evoked that slow changing baseline drift is difficult to Manuscript received January 8, 2014; revised February. 2, 2014. M. Y. Author is with the Interdisciplinary Graduate School of Agriculture and Engineering, University of Miyazaki, Miyazaki, Japan (corresponding author to provide phone: +818039961661; e-mail: nc11006@student.miyazaki-u.ac.jp). H. T. Author is with Department of Electrical and Electronic Engineering, University of Miyazaki, Miyazaki, Japan. K. Y. Author is with Department of Electrical and Electronic Engineering, University of Miyazaki, Miyazaki, Japan. estimate in continuous EOG signals, and this drift is only appeared in direct current (abbr. DC) signals caused in the circuit. To overcome this issue, our system was proposed using alternating current (abbr. AC) of EOG to reduce baseline drift by segmentation of the signal [6-7]. In previous studies, the positions of the electrodes were always set as plus-channels same with direction of the eye movements. The horizontal channel was in charge of horizontal EOG signals and the vertical channel was in charge of vertical EOG signals. In this paper, we propose novel EOG system using cross-channel electrodes. This method is able to put the electrodes in place far from the eyeballs. In addition, this paper confirms that the cross-channel EOG signals have a similar performance to the conventional method. Using this system, EOG signals can be recorded when the patients focus on each direct. All these recorded 24 pattern signals could be analyzed by using fuzzy mathematics method. Gaze estimation can be recognized using EOG signals follow this method. II. THE MEASUREMENT SYSTEM USING EOG SIGNALS AND ITS USE ON MOUSE CURSOR CONTROL SYSTEM A. Cross-Channels As shown in Fig.1 (left), previous researchers used plus-channels for recording the EOG signals, the horizontal signals were recorded by Channel 1, and the vertical signals were recorded by Channel 2 [6-7]. In this paper, in order to improve the accuracy of the EOG signals, a new cross-channels method was proposed as shown in Fig.1 (right). The horizontal signals and the vertical signals could be recorded by both channels on the same time. It would be much easier to analysis the data using double signals. B. The EOG Device In this subsection, EOG measurement system design is proposed [6-7]. Fig.2 shows the formal scheme for the acquisition and analysis of the EOG signal for the control organization and flow of information through the system. Our proposal system is based on the five features, 1) Amplifier, 2) Low pass filter for channel 1 and 2, 3) High pass filter for channel 1 and 2, 4) A/D-convertor, and 5) mouse cursor control system. It consists of five electrodes, an A/D-convertor, a personal computer, and a monitor (shown Fig.2). In order to effectively filter functions, channel 3 (and channel 4) is used two amplifiers.

, March 12-14, 2014, Hong Kong Fig. 1. The Cross-Channels method of EOG (right figure) Fig. 4. The EOG signals recording samples in CH 1, 2,3 and 4 (Left) Fig. 2. The measurement system of EOG C. The EOG Signals Recording After signal amplitude(1000 times) and considering noise reduction measures in designing of the biopotential data acquisition system, four kinds of eyes movements (Right, Left, Up, and Down) can be recognized accurately. Our EOG system performance is well and the electronic noise reduction is also successful. But because the eyes of person are in form of oval, the horizontal EOG signals are strong than the vertical EOG signals. The Fig.3, Fig.4 and Fig.5 and Fig.6 showed that 4 eyes movements are clearly different (right, left, up and down). Moreover, channel 1(CH1) and 2(CH2) have the DC level signals, so that the change of the EOG by the eyes movements can be recorded continuously and the continuous control for mouse cursor becomes possible. Channel 3(CH3) and channel 4(CH4) are the AC level signals of the EOG. Therefore, CH3 and CH4 are strongly reacted while eyes moving only. Fig. 5. The EOG signals recording samples in CH 1, 2,3 and 4 (Up) Fig. 6. The EOG signals recording samples in CH 1, 2,3 and 4 (Down) Fig. 3. The EOG signals recording samples in CH 1, 2,3 and 4 (Right) Because the EOG signals changed in all 4 eyes movements, in order to understand the devison of these 4 eyes movements further, we imported 2 different methods, CH1+CH2 for the vertical signals and CH1-CH2 for the horizontal signals. We asked the experimenter to move his eyeballs follow the sequence as Center Right Center Left Center Up

, March 12-14, 2014, Hong Kong Center Down - Center, and the results of these two new method are shown in Fig.7. This Fig.7 shows that our system has the similar EOG signals of the conventional method. B. The results of Experiments of M.Y The average degree of each angle in the experiments is shown in Fig.9 and Fig.10. And the result of another subject of the experiments is shown in the next subsection. Fig. 9. The results of the experiments (M.Y) (10 groups DC signals) Fig. 7. The EOG signals recording samples in CH1+CH2(Up side) and CH1-CH2(Down side). III. OFFLINE EXPERIMENTS AND RESULTS In order to record the EOG signals when the patients focused on each direct, we use the screen shown in Fig.8. The size of the monitor is 23 inches. The distance between the eyes of subject and the monitor is 50cm. the subjects of the experiments are three 20th healthy males (M.Y, K.G and K.M) who agreed to join in this experiment unforced. A. Offline Experiments method By using the screen shown in Fig. 8, we record the EOG signals when the patient focus its eyeballs right ahead. Then we ask the subject focus its eyeballs on the two crossing-points which were set on the left/right 30 degree position from right ahead, and record both DC and AC amplitude changes in CH1, CH2, CH3 and CH4. With the same method, we also record the amplitude changes when the patient focus its eyeballs on the left/right 30, 45, 60, 75 degree position for up (u), middle (m) and down (d) from right ahead. All these data (24 angles) are considered as one group. We continue the experiments until recording ten groups data and re-initialize the system by 1 group. We have 6 groups of the teacher data and 4 groups of test data. IV. Fig. 10. The results of the experiments (M.Y) (10 groups AC signals) MATHEMATICAL MODELING OF THE RESULTS OF OFFLINE EXPERIMENTS In order to get the rules for the gaze estimation judgment, we tried fuzzy mathematics methods, and the results of offline experiments were used as database. A. Fuzzy mathematics analysis All the DC and AC amplitude changes for each angle could be considered as fuzzy sets, in addition, we also used CH1+CH2 and CH1-CH2 as two fuzzy sets and its membership function is as below: (1) (i=1 to 24; j=ch1, CH2, CH3, CH4, CH1+CH2 and CH1-CH2) is the average value and σ is standard deviation. And the membership function for each angle is as below: (2) Fig. 8. The screen for EOG signals recording(24 angles) If we choose the first six groups data as the teacher data, we

, March 12-14, 2014, Hong Kong can get the teacher database using the average and the standard deviation. Use (1) and (2) to compute the membership Aij. For example, the first data of group 7 is (CH1: -1.0423; CH2:-10.0326; CH3: 1.4263; CH4: 18.9037). A 11 =1-[(-1.0423+0.9902)/0.1088] 2 =0.7703 A 12 =1-[(-10.0326+10.7927)/1.5032] 2 =0.7443 A 13 = A 14 = A 16 =0 A 15 =1-[(0.3840-0.2750)/0.1545] 2 =0.5026 A 1 = A 11 +A 12 +A 13 +A 14 +A 15 +A 16= 2.0172 We can also compute from A 2 to A 24 using the same method. Follow the maximum membership principle, we can know the first data of group 7 belong to set 1, and the predicted degree is -75(up). And the comparison between real degree and predicted degree of all three subjects are shown in Fig. 11, Fig.12 and Fig.13. The average correct rate of M.Y is 85.4%( 82/96), the average correct rate of K.G is 88.5%( 85/96), the average correct rate of K.M is 87.5%( 84/96) and the average correct rate of all three subjects is 87.1%. In addition, we compared the fuzzy mathematical method using 6 inputs and 4 inputs (CH1, CH2, CH3 and CH4). From other simulation results, 6 inputs method was about 2% better than 4 inputs method. In one step further, we also built the Fuzzy models for 8 angles (left/right 30,45,60,75 degrees) as shown in Fig.14 and 6 angles (left, right, left-up, left-down, right-up and right-down) as shown in Fig.15. The correct rate of M.Y is 97.9% for 8 angles (94/96), 96.9 % for 6 angles (93/96), the correct rate of K.G is 99.0% for 8 angles (95/96), 97.9% for 6 angles (94/96), and the correct rate of K.M is 97.9% for 8 angles (94/96), 97.9% for 6 angles (94/96). The average correct rate of all three subjects is 98.3% for 8 angles, 97.5% for 6 angles. Fig. 14. The screen for EOG signals recording (8 angles) Fig. 11. Correct and misjudge rate between real degree and predicted degree (M.Y) Fig. 15. The screen for EOG signals recording (6 angles) Fig. 12. Correct and misjudge rate between real degree and predicted degree (K.G) Fig. 13. Correct and misjudge rate between real degree and predicted degree (K.M) V. CONCLUSIONS AND DISCUSSIONS In this study, we introduced the EOG device which is used in the mouse cursor control system for amyotrophic lateral sclerosis patients successfully. In order to improve the precision accuracy of our system, we want to realize gaze estimation using EOG Signals. So we record both DC and AC amplitude changes of EOG signals when the people focus its eyeballs on 24 different positions from right ahead. With those data, we use mathematical modeling method, the fuzzy mathematics method. From the analysis results, we know that with numbers of database, the fuzzy mathematics method gets a good result. All the eyeballs movements can be recognized under an accuracy of 87.1%, and the patients also need move their eyeballs about 15 degree from one input button to the adjoining one in our system. So this accuracy is good enough for our system. Further, we compared our proposed method and the adaptive neuro fuzzy inference system (abbr. ANFIS) [8]. The

, March 12-14, 2014, Hong Kong ANFIS model had 92.7% accuracy of 24 patterns classification with the results of M.Y, but 71% accuracy with the results of K.G and K.M. The ANFIS is better than our proposed method in some cases and worse in some cases either. However, the ANFIS model is need a lot of parameter (224 parameters) and the parameter tuning algorithm. A new optimization algorithm must be created in order to improve the performance of ANFIS in all cases. In addition, we compared our proposed method, the original electrode position method and the ANFIS model in the horizontal angle of 8 patterns. Our proposed method is about 98.3%. The original electrode position method is about 100% [9]. In the horizontal angle of 8 patterns, two methods were almost same. However, our proposed method has the merit of the electrodes position and the general-purpose properties. In the future work, dynamic database are going to be imported into this system, so the accuracy will be improved into the higher level. And we also want to try this method in online experiments. Multiple-Valued Logic 2013, May 21-24, 2013, Toyama, Japan, pp.18-22. ACKNOWLEDGMENT This research has been support by Miyazaki Prefectural Industrial Support Foundation (R&D) and Grant-Aid for Young Scientists(B)( 23700668) KAKEN. REFERENCES [1] S. Venkataramanan, P. Prabhat, S. R. Choudhury, H. B. Nemade, and J. S. Sahambi, Biomedical instrumentation based on Electrooculogram (EOG) signal processing and application to a hospital alarm system, in Proceedings of the 2nd IEEE International Conference on Intelligent Sensing and Information Processing (ICISIP 05), Chennai, India, January 2005, pp. 535 540,. [2] R. Barae, L. Boquete, and M.Mazo, System for assitedmobility using eye movements based on electrooculography, IEEE Transaction on Neural Systems and Rehabilitation Engineering, vol. 10, no. 4, 2002, pp. 209 218. [3] Z. Lv, X. Wu, M. Li, and C. Zhang, Implementation of the EOG-based human computer interface system, in Proceedings of the 2nd International Conference on Bioinformatics and Biomedical Engineering (ICBBE 08), Shanghai, China, May 2008, pp. 2188 2191. [4] C. K. Young and M. Sasaki, Mobile robot control by neural network EOG gesture recognition, in Proceedings of the 8th International Conference on Neural Information Processing, vol.1, 2001, pp. 322 328. [5] T. Manabe, H. Tamura, K. Tanno, The Control Experiments of the Electric Wheelchair using s-emg of Facial Muscles, Proceedings of Forum on Information Technology 2009 (FIT2009),CD-ROM, 2009. (Japanese), pp. K-008 [6] H. Tamura, M. Miyashita, K. Tanno, Y. Fuse Mouse cursor control system using electrooculogram signals, Proceedings of World Automation Congress 2010, IFMIP 239, CDROM, 2011, pp.1-6. [7] H. Tamura, M. Yan, M. Miyashita, T. Manabe, K. Tanno, and Y. Fuse Development of Mouse Cursor Control System using DC and AC Elements of Electrooculogram Signals and its Applications," International Journal of Intelligent Computing in Medical Sciences & Image Processing, Vol 5.No1, 2013, pp.3-15. [8] H. Tamura,K. Tanno,H. Tanaka, C. Kuramitz, Z. Tang, Recurrent Type ANFIS Using Local Search Technique for Time Series Prediction, Proceedings CDROM, 2008 IEEE Asia Pacific Conference on Circuits and Systems, Nov 30 - Dec 3, 2009, Macao, China, pp. 380-383, [9] M. Yan, H. Tamura, K. Tanno, Gaze Estimation Using Electrooculogram Signals and Its Mathematical Modeling, Proceedings CDROM, IEEE 43rd International Symposium on