C400-NMTM-1M Product Classification Brand Product Series Product Type CNT-400 CNT Jumper with interface types N Male and TNC Male, 1m CNT CNT-400 Braided cable assembly General Specifications Body Style, Connector A Straight Body Style, Connector B Straight Interface, Connector A N Male Interface, Connector B TNC Male Length 1.000 m 3.281 ft Nominal Size 0.400 in Specification Sheet Revision Level A Jumper Assembly Sample Label Return Loss/VSWR Frequency Band VSWR Return Loss (db) 700 2000 MHz 1.22 20.00 700 3000 MHz 1.29 18.00 page 1 of 14 most current information. Revised: November 10, 2017
C400-NMTM-1M Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant by Exemption China RoHS SJ/T 11364-2006 Above Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system Included Products 400PTM-C TNC Male for CNT-400 braided cable CNT-400 CNT-400, CNT 50 Ohm Braided Coaxial Cable, variable, black PE jacket 400APNM-C Type N Male for CNT-400 braided cable CNT-400-SFR CNT-400-SFR, C CNT 50 Ohm Braided Coaxial Cable, black non-halogenated, fire retardant polyolefin jacket, B2ca S1a d0 a1 Compliant page 2 of 14 most current information. Revised: November 10, 2017
400PTM-C TNC Male for CNT-400 braided cable OBSOLETE This product was discontinued on: February 25, 2015 Replaced By 400BPTM-C TNC Male for CNT-400 braided cable Product Classification Brand Product Type General Specifications Interface Body Style Electrical Specifications Operating Frequency Band Cable Impedance Connector Impedance RF Operating Voltage, maximum (vrms) dc Test Voltage Outer Contact Resistance, maximum Inner Contact Resistance, maximum Insulation Resistance, minimum Average Power Peak Power, maximum Insertion Loss, typical CNT Braided cable connector TNC Male Straight 0 6000 MHz 50 ohm 50 ohm 500.00 V 1500 V 0.40 mohm 1.50 mohm 5000 MOhm 580.0 W @ 900 MHz 5.00 kw 0.05 db page 3 of 14
400PTM-C Outline Drawing Mechanical Specifications Outer Contact Attachment Method Clamp Outer Contact Plating Trimetal Inner Contact Plating Gold Inner Contact Attachment Method Captivated Interface Durability 500 cycles Interface Durability Method IEC 61169-17:17 Connector Retention Tensile Force 330 N 74 lbf Connector Retention Torque 0.56 N-m 0.41 ft lb Coupling Nut Proof Torque 1.70 N-m 1.25 ft lb Coupling Nut Proof Torque Method IEC 61169-17:9.3.6 Coupling Nut Retention Force 445.00 N 100.04 lbf Coupling Nut Retention Force Method IEC 61169-17:9.3.11 Dimensions Nominal Size Diameter Length Weight 0.405 in 20.00 mm 0.79 in 44.95 mm 1.77 in 44.22 g 0.10 lb page 4 of 14
400PTM-C Width 20.00 mm 0.79 in Environmental Specifications Operating Temperature Storage Temperature Immersion Depth Immersion Test Mating Immersion Test Method Regulatory Compliance/Certifications * Footnotes -40 C to +85 C (-40 F to +185 F) -65 C to +125 C (-85 F to +257 F) 1 m Mated IEC 60529:2001, IP68 Mechanical Shock Test Method IEC 60068-2-27 Climatic Sequence Test Method IEC 60068-1 Damp Heat Steady State Test Method IEC 60068-2-3 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 C 68 F Average Power, Ambient Temperature 40 C 104 F Average Power, Inner Conductor Temperature 100 C 212 F Return Loss/VSWR Frequency Band VSWR Return Loss (db) 0 3000 MHz 1.05 33.00 3000 6000 MHz 1.17 22.00 Agency ISO 9001:2008 Classification Designed, manufactured and/or distributed under this quality management system Immersion Depth Insertion Loss, typical Immersion at specified depth for 24 hours 0.05v freq (GHz) (not applicable for elliptical waveguide) page 5 of 14
CNT-400 CNT-400, CNT 50 Ohm Braided Coaxial Cable, variable, black PE jacket Product Classification Brand Product Series Product Type Construction Materials Jacket Color Jacket Material Braid Material Shield Tape Material Dielectric Material Inner Conductor Material Dimensions Cable Weight Diameter Over Dielectric Diameter Over Jacket Diameter Over Tape Inner Conductor OD Nominal Size Outer Conductor OD Electrical Specifications Cable Impedance Capacitance dc Resistance, Inner Conductor dc Resistance, Outer Conductor dc Test Voltage Jacket Spark Test Voltage (rms) CNT CNT-400 Braided coaxial cable Black Non-halogenated PE Tinned copper Aluminum Foam PE Copper-clad aluminum wire 0.10 kg/m 7.240 mm 0.285 in 10.290 mm 0.405 in 7.391 mm 0.291 in 2.7400 mm 0.1079 in 0.400 in 8.080 mm 0.318 in 50 ohm 78.0 pf/m 24.0 pf/ft 4.690 ohms/km 1.430 ohms/kft 5.610 ohms/km 1.710 ohms/kft 2500 V 4000 V page 6 of 14
CNT-400 Maximum Frequency 16.20 GHz Operating Frequency Band 30 6000 MHz Peak Power 16.0 kw Shielding Effectiveness >90 db Velocity 85% Environmental Specifications Installation Temperature -40 C to +85 C (-40 F to +185 F) Operating Temperature -40 C to +85 C (-40 F to +185 F) Storage Temperature -70 C to +85 C (-94 F to +185 F) General Specifications Cable Type Braid Coverage CNT-400 90% braid Mechanical Specifications Bending Moment Flat Plate Crush Strength 0.7 N-m 0.5 ft lb 0.7 kg/mm 40.0 lb/in Minimum Bend Radius, Single Bend 25.40 mm 1.00 in Tensile Strength Electrical Performance 73 kg 160 lb Frequency Attenuation (db/100 m) Attenuation (db/100 ft) 30 MHz 2.49 0.76 50 MHz 3.18 0.97 150 MHz 4.92 1.50 220 MHz 6.23 1.90 450 MHz 8.86 2.70 900 MHz 12.80 3.90 1500 MHz 16.70 5.10 1800 MHz 18.40 5.60 2000 MHz 19.40 5.90 2400 MHz 21.65 6.60 2500 MHz 22.00 6.70 3000 MHz 24.60 7.50 4000 MHz 28.87 8.80 4500 MHz 30.84 9.40 5000 MHz 32.81 10.00 5200 MHz 33.46 10.20 5500 MHz 34.78 10.60 5800 MHz 35.76 10.90 6000 MHz 36.42 11.10 page 7 of 14
CNT-400 Regulatory Compliance/Certifications Agency Classification RoHS 2011/65/EU Compliant China RoHS SJ/T 11364-2006 Below Maximum Concentration Value (MCV) ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system page 8 of 14
400APNM-C Type N Male for CNT-400 braided cable OBSOLETE This product was discontinued on: June 18, 2012 Replaced By 400BPNM-C 400BPNM-C-G Type N Male for CNT-400 braided cable Type N Male for CNT-400 braided cable (Gold Pin) Product Classification Brand Product Type General Specifications Interface Body Style Electrical Specifications Operating Frequency Band Cable Impedance Connector Impedance RF Operating Voltage, maximum (vrms) dc Test Voltage Outer Contact Resistance, maximum Inner Contact Resistance, maximum Insulation Resistance, minimum Peak Power, maximum Insertion Loss, typical CNT Braided cable connector N Male Straight 0 6000 MHz 50 ohm 50 ohm 707.00 V 2500 V 0.25 mohm 1.00 mohm 5000 MOhm 10.00 kw 0.05 db page 9 of 14
400APNM-C Outline Drawing Mechanical Specifications Outer Contact Attachment Method Clamp Outer Contact Plating Trimetal Inner Contact Plating Gold Inner Contact Attachment Method Captivated Interface Durability 500 cycles Interface Durability Method IEC 61169-16:9.5 Connector Retention Tensile Force 330 N 74 lbf Connector Retention Torque 0.56 N-m 0.41 ft lb Coupling Nut Proof Torque 1.70 N-m 1.25 ft lb Coupling Nut Proof Torque Method IEC 61169-16:9.3.6 Coupling Nut Retention Force 450.00 N 101.16 lbf Coupling Nut Retention Force Method IEC 61169-16:9.3.11 Dimensions Nominal Size Diameter Length Weight 0.405 in 20.25 mm 0.80 in 38.22 mm 1.50 in 47.08 g 0.10 lb page 10 of 14
400APNM-C Width 20.25 mm 0.80 in Environmental Specifications Operating Temperature Storage Temperature Immersion Depth Immersion Test Mating Immersion Test Method Regulatory Compliance/Certifications * Footnotes -40 C to +85 C (-40 F to +185 F) -65 C to +125 C (-85 F to +257 F) 1 m Mated IEC 60529:2001, IP68 Mechanical Shock Test Method IEC 60068-2-27 Climatic Sequence Test Method IEC 60068-1 Damp Heat Steady State Test Method IEC 60068-2-3 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 C 68 F Average Power, Ambient Temperature 40 C 104 F Average Power, Inner Conductor Temperature 100 C 212 F Return Loss/VSWR Frequency Band VSWR Return Loss (db) 0 3000 MHz 1.05 33.00 3000 6000 MHz 1.17 22.00 Agency ISO 9001:2008 Classification Designed, manufactured and/or distributed under this quality management system Immersion Depth Insertion Loss, typical Immersion at specified depth for 24 hours 0.05v freq (GHz) (not applicable for elliptical waveguide) page 11 of 14
CNT-400-SFR CNT-400-SFR, C CNT 50 Ohm Braided Coaxial Cable, black nonhalogenated, fire retardant polyolefin jacket, B2ca S1a d0 a1 Compliant Product Classification Brand Product Series Product Type CNT CNT-400 Braided coaxial cable Standards And Qualifications EN50575 CPR Cable EuroClass B2ca s1a d0 a1 Construction Materials Jacket Color Jacket Material Braid Material Shield Tape Material Dielectric Material Inner Conductor Material Dimensions Cable Weight Diameter Over Dielectric Diameter Over Jacket Diameter Over Tape Inner Conductor OD Nominal Size Outer Conductor OD Electrical Specifications Cable Impedance Capacitance dc Resistance, Inner Conductor Black Non-halogenated, fire retardant polyolefin Tinned copper Aluminum Foam PE Copper-clad aluminum wire 0.10 kg/m 7.240 mm 0.285 in 10.290 mm 0.405 in 7.391 mm 0.291 in 2.7400 mm 0.1079 in 0.400 in 8.080 mm 0.318 in 50 ohm 78.0 pf/m 24.0 pf/ft 4.490 ohms/km 1.370 ohms/kft page 12 of 14 most current information. Revised: October 5, 2018
CNT-400-SFR dc Resistance, Outer Conductor 5.610 ohms/km 1.710 ohms/kft dc Test Voltage 2500 V Jacket Spark Test Voltage (rms) 4000 V Maximum Frequency 16.20 GHz Operating Frequency Band 30 6000 MHz Peak Power 16.0 kw Shielding Effectiveness >90 db Velocity 85% Environmental Specifications Installation Temperature -40 C to +60 C (-40 F to +140 F) Operating Temperature -40 C to +60 C (-40 F to +140 F) Storage Temperature -40 C to +60 C (-40 F to +140 F) General Specifications Cable Type Braid Coverage CNT-400 90% braid Mechanical Specifications Bending Moment Flat Plate Crush Strength 0.7 N-m 0.5 ft lb 0.7 kg/mm 40.0 lb/in Minimum Bend Radius, Single Bend 25.40 mm 1.00 in Smoke Index Test Method IEC 61034 Tensile Strength 73 kg 160 lb Toxicity Index Test Method IEC 60754-2 Electrical Performance Frequency Attenuation (db/100 m) Attenuation (db/100 ft) 30 MHz 2.49 0.76 50 MHz 3.18 0.97 150 MHz 4.92 1.50 220 MHz 6.23 1.90 450 MHz 8.86 2.70 900 MHz 12.80 3.90 1500 MHz 16.70 5.10 1800 MHz 18.40 5.60 2000 MHz 19.40 5.90 2400 MHz 21.65 6.60 2500 MHz 22.00 6.70 3000 MHz 24.60 7.50 4000 MHz 28.87 8.80 4500 MHz 30.84 9.40 page 13 of 14 most current information. Revised: October 5, 2018
CNT-400-SFR 5000 MHz 32.81 10.00 5200 MHz 33.46 10.20 5500 MHz 34.78 10.60 5800 MHz 35.76 10.90 6000 MHz 36.42 11.10 Regulatory Compliance/Certifications Agency RoHS 2011/65/EU China RoHS SJ/T 11364-2006 ISO 9001:2008 CENELEC Classification Compliant Below Maximum Concentration Value (MCV) Designed, manufactured and/or distributed under this quality management system page 14 of 14 most current information. Revised: October 5, 2018