Effective Harmonic Mitigation with Active Filters

Similar documents
Technical Paper. Harmonic Distortion in Data Centers

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

7/15/2002 PP.AFD.08 1 of 28

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Electromagnetic Harmonic Filters Technical Guide

NJWA - Harmonics and Drives Proper System Design

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

HARMONIC MITIGATIONCASE STUDY

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Low Pass Harmonic Filters

Economical Solutions to Meet Harmonic Distortion Limits[4]

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Drives 101 Lesson 5. Power Input Terminology for a VFD

Active Harmonic Filter (AF3)

Open-Delta Systems Affect Variable Frequency Drives

Reducing Total Harmonic Distortion with Variable Frequency Drives

MIRUS International Inc.

How Harmonics have led to 6 Power Factor Misconceptions

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Harmonics White Paper

VFDs and Harmonics in HVAC Applications

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Harmonic Filters for Single Phase Equipment

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Harmonic Distortion and Variable Frequency Drives

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Prepared By Pierre Archambault, PEng Power Survey International Inc Trans Canada Hwy. St-Laurent, QC H4S 1S4 CANADA

Harmonic Mitigating Transformer - Technical Guide

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Understanding Harmonics

GE Energy. Matrix Harmonic Filter Series D

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Alternator winding pitch and power system design

Understanding Input Harmonics and Techniques to Mitigate Them

Mitigation of Harmonics Produced by Nonlinear Loads in Industrial Power System

International Journal of Research Available at

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

Peteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS. ABB Group December 14, 2011 Slide 1

Harmonic Mitigation Harmonic Data Comparisons

An Active Interphase Transformer for 12-Pulse Rectifier System to Get the Performance Like 24- Pulse Rectifier System

Amps Without HGA. Amps With HGA. Amps Without HSD Time (ms)

Harmonics Elimination Using Shunt Active Filter

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

The increase in the application

22.0 Harmonics in Industrial Power Systems

Power IT LV Active Filters PQFA - PQFL - PQFT

Reliable power onboard and offshore

Harmonic Mitigation in AC DC Converters for Induction Motor Drives by Vector Controlled

APPLICATION GUIDE. Harmonics in HVAC applications

Power Factor & Harmonics

Introduction to Rectifiers and their Performance Parameters

Power Quality Improvement using a 28-pulse AC-DC Converter for SMPS

Harmonics Reduction using 4-Leg Shunt Active Power Filters

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

How adjustable speed drives affect power distribution

LINEATOR. Advanced Universal Harmonic Filter

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive

Harmonics, its Mitigation & Result of Case study of Spinning Mill

ECET Modern Power

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

VARIABLE FREQUENCY DRIVE

Analysis of Harmonic Distortion in Non-linear Loads

ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005

Lecture Note. DC-AC PWM Inverters. Prepared by Dr. Oday A Ahmed Website:

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

Volume I Issue VI 2012 September-2012 ISSN

Alternative Designs to Support Electronic Loads in Extensive UPS Distribution Systems

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS)

The Occurrence of Faults in Permanent Magnet Synchronous Motor Drives and its Effects on the Power Supply Quality

CHAPTER 4 HARMONICS AND POWER FACTOR

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Electromagnetic Harmonic Filters Technical Guide

Lineator-HP High Performance model used where the highest power quality demands must be met

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Matrix Drives Boost Power Quality and Energy Savings

Effects of Harmonic Distortion I

Performance Analysis of Passive Filter for Harmonics Due to Non-Linear Load in Power System

Power Quality Analysis in Power System with Non Linear Load

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

CHAPTER 4 FULL WAVE RECTIFIER. AC DC Conversion

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Reduction Of Harmonics By Using Active Harmonic Filter

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Phoenix DX Clean Power (18 Pulse) AC Drive

Fluke 40/41 Power Harmonics Analysers

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Power Quality enhancement of a distribution line with DSTATCOM

Fundamentals of Power Quality

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

Transcription:

Advancing Power Quality White Paper Effective Harmonic Mitigation with Active Filters Written by: Ian Wallace Variable Speed Drive with no Harmonic Mitigation Industry standard variable speed drives, with 6 pulse diode input rectifiers are the workhorse of industry. They are used primarily for variable speed control of ac induction motors to achieve more efficienct process control and energy savings. Industry standard three phase variable speed drives draw harmonic currents from the three phase voltage source. These harmonics can cause overheating and premature failure of power system equipment such as transformers, cables and circuit breakers. The harmonic currents are at higher frequencies than the 60Hz voltage supply. Units Standalone VFD VFD Power Rating HP 500 Input Current Amps 544 Fundamental 60Hz Current Amps 513 Harmonic Current Amps 181 Input Current Distortion %ithd 35.2% Input Voltage Distortion %vthd 4.03% Table 1: Summary of standalone 500HP VFD AC input A 480V 3 phase power system with a typical 500HP VFD with an internal 3% ac input line reactor is shown in Figure 1. The power system transformer feeding the drive is 2000kVA with 5.75% impedance. This system was simulated to characterize the harmonic input voltage and currents caused by the VFD. At full load and steady state, the input current and voltage to the 500HP VFD is shown in Figure 2. The input current has a 35% current THD, meaning that harmonic currents are 35% of the 60Hz current. This current distortion in turn produces a voltage distortion across the 2000kVA transformer that powers and may adversely affect other loads on the system. The THD of the voltage in Figure 2 is 4%. A frequency spectrum of the voltage and current is shown in Figure 3. The 5th harmonic current (at 300Hz) is the highest individual harmonic at over 30%. Figure 1: Simulation Model Schematic of a power system with a 500HP VFD and front end active filter 1

Figure 2: VFD Input current (35% ithd) and voltage (4% vthd) time domain waveforms for a standalone VFD without active filter Figure 3: VFD Input current and voltage frequency spectrum for a standalone VFD without an active filter 2

Variable Speed Drive with an Active Filter Active filters are highly effective at reducing the harmonic current in the power system to safe levels while allowing the VFD to draw the harmonic currents it needs. The active filter works by measuring the power system current and injecting the necessary harmonic current to cancel the VFD harmonics. As the filter is an active device is can quickly respond to changes in VFD loading and power system voltage, frequency, unbalance and background voltage distortion conditions. This concept of applying an active filter is illustrated in Figure 4. Figure 4: Applying an Active Filter to the electrical power system or input to a VFD Benefits of Active filters to reduce current THD at the input of VFDs are: They can be applied to a whole power system, group of loads or on individual standard 6 pulse VFDs MCC Compatible Can achieve harmonic current reduction to <5% ithd Monitors the bus, injects counter current to cancel out harmonic currents Provides Power Factor Correction if necessary To determine the reduction of harmonic currents achievable with an active filter the 480V 3 phase power system and 500HP VFD were modeled and analyzed, as shown in Figure 5. 3

Variable Speed Drive with an Active Filter (cont.) Figure 5: Simulation Model Schematic of a power system with a 500HP VFD and front end active filter The active filter removes the harmonic currents from the input feed as reflected in the time domain waveforms, shown in Figure 6. The line current and line voltage are near sinusoidal. The current distortion and voltage distortion have been reduced to 3.21% and 0.34% respectively, well under the most stringent IEEE 519 recommended limits. Figure 6 also shows the harmonic current injected by the active filter, which contains higher frequencies than the source 60 Hz. The frequency spectrum of the filtered source current and voltage is in Figure 7, where the peak current component at the 5th harmonic (300Hz) has been reduced to 2.9%. Units Active Filter And VFD VFD Power Rating HP 500 Input Current Amps 496 Fundamental 60Hz Current Amps 495 Harmonic Current Amps 15.9 Input Current Distortion %ithd 3.21% Input Voltage Distortion %vthd.34% Active Filter Injection Current Amps 226 Table 2: Summary of Active Filter and 500HP VFD AC 4

Variable Speed Drive with an Active Filter (cont.) Figure 6: VFD Input current and Active filter injection current, and ac voltage time domain waveforms for a standalone VFD with an active filter Figure 7: VFD Input current and voltage frequency spectrum for a standalone VFD with an active filter 5

Summary An active filter is an effective way to filter the harmonic currents required by VFDs and eliminate the harmonic currents and voltages from the AC source. In the case study presented, the active filter reduced the total RMS currents in the source by almost 10%, while reducing the current distortion from 35% to 3.2% THD. Resultantly, the voltage distortion was reduced from 4% to under 0.5%. Units Standalone VFD Active Filter And VFD VFD Power Rating HP 500 500 Input Current Amps 544 496 Fundamental 60Hz Current Amps 513 495 Harmonic Current Amps 181 15.9 Input Current Distortion %ithd 35.2% 3.21% Input Voltage Distortion %vthd 4.03%.34% Active Filter Injection Current Amps -- 226 On a 480V, 60Hz power system with 2000kVA transformer with 5.75% impedance Table 3: Summary of 500HP VFD with and without an Active Filter W132 N10611 Grant Drive, Germantown, WI 53022 P: 800-824-8282 transcoil.com 6